Tomoaki Nishino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tomoaki Nishino has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Keisuke Himoto
National Institute for Land and Infrastructure Management (NILIM), Tsukuba, Japan
6 shared publications Takeyoshi Tanaka
Research Center for Disaster Mitigation of Urban Cultural Heritage Ritsumeikan University 56‐1 Toji‐in Kitamachi Kita Kyoto 603‐8577 Japan
6 shared publicationsAkihiko Hokugo
Prof., Research Center for Urban Safety and Security, Kobe Univ., Ph.D.
5 shared publicationsYugo Imazu
4 shared publicationsHiroaki Notake
Institute of Technology Shimizu Corporation Koto‐ku Tokyo Japan
3 shared publicationsAya Hada
Disaster Prevention Research Institute Kyoto University Uji Kyoto Japan
2 shared publications
Latest Publications
- Open Access
- 22 June 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (11) , 2897-2915
Empirical Model of Post‐Earthquake Restoration Time for Building Components Based on Data From the 2022 Fukushima‐ken Oki Earthquake in Japan
Estimation of the time required for damaged building components to return to their pre‐earthquake conditions through repair is a critical element in assessing the seismic resilience of buildings, and it requires consideration of uncertainty. This study investigated such time distributions using actual time‐to‐restoration data obtained from earthquake‐affected buildings through a questionnaire survey. As a starting point, data for 131 buildings that did not incur severe structural damage and disruptions to lifeline infrastructure from the 2022 Fukushima‐ken Oki earthquake in Japan were analyzed. Hierarchical Bayesian Weibull/mixed‐Weibull regression yielded an empirical model describing the probability of restoration as a function of time for seven building component types, including columns and beams, exterior walls, partition walls, interior doors, ceilings, lighting fixtures, and plumbing. The following conclusions were drawn from the developed model. (1) Building components are clearly divided into those with high and low restoration priorities. (2) High‐priority building components, including plumbing, lighting fixtures, partition walls (in cases of falling), and ceilings (in cases of falling), are restored approximately 75–132 days after an earthquake, with 99% probability. (3) The restoration of low‐priority building components occurs approximately randomly over time. The synthesized time‐to‐restoration distribution, incorporating probabilistic estimates of lifeline infrastructure downtime as initial delays, highlights that both the lifeline infrastructure downtime and subsequent phase duration substantially affect the overall distribution given a ground motion level defined by the Japanese building code. These results provide useful information that supports the resilience‐based seismic design of buildings.
- 22 June 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (11) , 2897-2915
Open AccessEmpirical Model of Post‐Earthquake Restoration Time for Building Components Based on Data From the 2022 Fukushima‐ken Oki Earthquake in Japan
Estimation of the time required for damaged building components to return to their pre‐earthquake conditions through repair is a critical element in assessing the seismic resilience of buildings, and it requires consideration of uncertainty. This study investigated such time distributions using actual time‐to‐restoration data obtained from earthquake‐affected buildings through a questionnaire survey. As a starting point, data for 131 buildings that did not incur severe structural damage and disruptions to lifeline infrastructure from the 2022 Fukushima‐ken Oki earthquake in Japan were analyzed. Hierarchical Bayesian Weibull/mixed‐Weibull regression yielded an empirical model describing the probability of restoration as a function of time for seven building component types, including columns and beams, exterior walls, partition walls, interior doors, ceilings, lighting fixtures, and plumbing. The following conclusions were drawn from the developed model. (1) Building components are clearly divided into those with high and low restoration priorities. (2) High‐priority building components, including plumbing, lighting fixtures, partition walls (in cases of falling), and ceilings (in cases of falling), are restored approximately 75–132 days after an earthquake, with 99% probability. (3) The restoration of low‐priority building components occurs approximately randomly over time. The synthesized time‐to‐restoration distribution, incorporating probabilistic estimates of lifeline infrastructure downtime as initial delays, highlights that both the lifeline infrastructure downtime and subsequent phase duration substantially affect the overall distribution given a ground motion level defined by the Japanese building code. These results provide useful information that supports the resilience‐based seismic design of buildings.
- Open Access
- 19 January 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (5) , 1116-1133
Modeling the Probability of Tsunami Fire Ignition Based on Data From the 2011 Tohoku and 2024 Noto Peninsula Earthquakes, With Recommendations to Reduce Emerging Fire Risk in Tsunami Vertical Evacuation Structures
Recent tsunamigenic earthquakes in Japan have highlighted the emerging fire hazard triggered by tsunami inundation and its impact on tsunami vertical evacuation (TVE) structures. This new type of fire following earthquake, referred to as “tsunami fires,” may be a potential universal hazard that tsunami‐prone countries face; however, it has not been considered in earthquake‐related risk management. As part of initiatives to evolve regional fire‐following‐earthquake risk assessments, this study focuses on modeling the uncertainty of tsunami fire occurrences. An analysis of 92 tsunami fires following the 2011 Tohoku and 2024 Noto Peninsula earthquakes reveals the following. (1) In areas of high tsunami intensity where numerous wooden houses and automobiles are washed away, tsunami fires may mostly start from tsunami debris that is washed away and accumulated by the tsunami or may start while tsunami debris is being transported by the tsunami and then accumulated while burning; conversely, in areas of low tsunami intensity where few wooden houses and automobiles are washed away, tsunami fires may mostly start from electricity‐related sources in tsunami‐inundated buildings and automobiles. (2) The probability of tsunami fire ignition is approximately 2–6 fires on average per 10,000 tsunami‐inundated buildings, depending on the building washout ratio, and varies from approximately 1/3 to 3 times that of the average within one sigma due to unobserved regional differences. Recommendations to prevent losses of life in TVE structures caused by tsunami fires are presented. These findings will help us better understand and prepare for tsunami fires as earthquake‐related cascading hazards.
- 19 January 2026
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 55 (5) , 1116-1133
Open AccessModeling the Probability of Tsunami Fire Ignition Based on Data From the 2011 Tohoku and 2024 Noto Peninsula Earthquakes, With Recommendations to Reduce Emerging Fire Risk in Tsunami Vertical Evacuation Structures
Recent tsunamigenic earthquakes in Japan have highlighted the emerging fire hazard triggered by tsunami inundation and its impact on tsunami vertical evacuation (TVE) structures. This new type of fire following earthquake, referred to as “tsunami fires,” may be a potential universal hazard that tsunami‐prone countries face; however, it has not been considered in earthquake‐related risk management. As part of initiatives to evolve regional fire‐following‐earthquake risk assessments, this study focuses on modeling the uncertainty of tsunami fire occurrences. An analysis of 92 tsunami fires following the 2011 Tohoku and 2024 Noto Peninsula earthquakes reveals the following. (1) In areas of high tsunami intensity where numerous wooden houses and automobiles are washed away, tsunami fires may mostly start from tsunami debris that is washed away and accumulated by the tsunami or may start while tsunami debris is being transported by the tsunami and then accumulated while burning; conversely, in areas of low tsunami intensity where few wooden houses and automobiles are washed away, tsunami fires may mostly start from electricity‐related sources in tsunami‐inundated buildings and automobiles. (2) The probability of tsunami fire ignition is approximately 2–6 fires on average per 10,000 tsunami‐inundated buildings, depending on the building washout ratio, and varies from approximately 1/3 to 3 times that of the average within one sigma due to unobserved regional differences. Recommendations to prevent losses of life in TVE structures caused by tsunami fires are presented. These findings will help us better understand and prepare for tsunami fires as earthquake‐related cascading hazards.
- Open Access
- 15 May 2025
- Published by Wiley in Earthquake Spectra
- Vol. 41 (3) , 1998-2027
Fires following the 2024 Noto Peninsula earthquake: Insights from ignition records, a fire damage survey, and a prospective regional fire risk assessment
Rupture of an active fault across the Noto Peninsula, Japan, generated a moment magnitude 7.5 earthquake on 1 January 2024 causing multiple cascading hazards with significant impacts on communities. This study focuses on the fire‐following‐earthquake aspects of the 2024 Noto Peninsula earthquake. Along with a summary of ignition records collected from municipal fire departments and field observations in several large fire‐affected areas, the fire‐following‐earthquake risk that would have been estimated for the building stock is quantified using a hypothetical earthquake source model developed prior to the earthquake. Using this case study, the effect of future climate change on regional fire‐following‐earthquake risk assessments is also investigated. The 17 fires following the earthquake included both shaking‐induced and tsunami‐induced fires, 3 of which enlarged significantly outside and within the tsunami inundation zone. The two fires within the tsunami inundation zone started from an inundated building and an inundated automobile and spread to 18 tsunami‐inundated buildings in total. The inferred ignition rate for the shaking‐induced fires, mostly from electricity‐related ignition sources, was high relative to recent large earthquakes in Japan. Conventional factors, including delayed fire detection, unavailable fire hydrants resulting from seismic damage to water supply systems, and inaccessible fire cisterns resulting from collapsed buildings, led to a large fire in downtown Wajima that destroyed ~240 buildings. This fire loss corresponded to a 1.9% conditional exceedance probability according to 6000 stochastically synthesized fire‐following‐earthquake scenarios. Typical meteorological year data based on global warming projections allow synthetic future hourly weather parameter values to be linked to long‐term probabilistic fire losses, revealing that the average increases in hourly air temperature and wind velocity and average decreases in hourly relative humidity in future climate change projections can increase fire loss exceedance probabilities. These findings emphasize that further efforts to reduce the risk of fires following earthquakes are essential.
- 15 May 2025
- Published by Wiley in Earthquake Spectra
- Vol. 41 (3) , 1998-2027
Open AccessFires following the 2024 Noto Peninsula earthquake: Insights from ignition records, a fire damage survey, and a prospective regional fire risk assessment
Rupture of an active fault across the Noto Peninsula, Japan, generated a moment magnitude 7.5 earthquake on 1 January 2024 causing multiple cascading hazards with significant impacts on communities. This study focuses on the fire‐following‐earthquake aspects of the 2024 Noto Peninsula earthquake. Along with a summary of ignition records collected from municipal fire departments and field observations in several large fire‐affected areas, the fire‐following‐earthquake risk that would have been estimated for the building stock is quantified using a hypothetical earthquake source model developed prior to the earthquake. Using this case study, the effect of future climate change on regional fire‐following‐earthquake risk assessments is also investigated. The 17 fires following the earthquake included both shaking‐induced and tsunami‐induced fires, 3 of which enlarged significantly outside and within the tsunami inundation zone. The two fires within the tsunami inundation zone started from an inundated building and an inundated automobile and spread to 18 tsunami‐inundated buildings in total. The inferred ignition rate for the shaking‐induced fires, mostly from electricity‐related ignition sources, was high relative to recent large earthquakes in Japan. Conventional factors, including delayed fire detection, unavailable fire hydrants resulting from seismic damage to water supply systems, and inaccessible fire cisterns resulting from collapsed buildings, led to a large fire in downtown Wajima that destroyed ~240 buildings. This fire loss corresponded to a 1.9% conditional exceedance probability according to 6000 stochastically synthesized fire‐following‐earthquake scenarios. Typical meteorological year data based on global warming projections allow synthetic future hourly weather parameter values to be linked to long‐term probabilistic fire losses, revealing that the average increases in hourly air temperature and wind velocity and average decreases in hourly relative humidity in future climate change projections can increase fire loss exceedance probabilities. These findings emphasize that further efforts to reduce the risk of fires following earthquakes are essential.
- Open Access
- 13 March 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 104
Empirical seismic fragility function for fire doors based on inspection data from the 1995 Kobe earthquake and its use in post-earthquake fire risk assessments
- 13 March 2025
- Published by Elsevier in Journal of Building Engineering
- Vol. 104
Open AccessEmpirical seismic fragility function for fire doors based on inspection data from the 1995 Kobe earthquake and its use in post-earthquake fire risk assessments
- Open Access
- 29 May 2024
- Published by Springer Nature in Architecture, Structures and Construction
- Vol. 4 (2-4) , 227-240
Post-earthquake building services downtime distribution: a case study of the 2016 Kumamoto, Japan, earthquake
Seismic damage to building services systems, that is, mechanical, electrical, and plumbing systems in buildings related to energy and indoor environments, affects the functionality of buildings. Assessing post-earthquake functionality is useful for enhancing the seismic resilience of buildings via improved design. Such assessments require a model for predicting the time required to restore building services. This study analyzes the downtime data for 250 instances of damage to building services components caused by the 2016 Kumamoto earthquake in Japan, presumably obtained from buildings with minor or no structural damage. The objectives of this study are (1) to determine the empirical downtime distribution of building services components and (2) to assess the dependence of the downtime on explanatory variables. A survival analysis, which is a statistical technique for analyzing time-to-event data, reveals that (1) the median downtime of building services components was 90 days and, 7 months after the earthquake, the empirical non-restoration probability was approximately 32%, (2) the services type and the building use are explanatory variables having a statistically significant effect on the downtime of building services components, (3) the log-logistic regression model reasonably captures the trend of the restoration of building services components, (4) medical and welfare facilities and hotels restored building services components relatively quickly, and (5) the 7-month restoration probability was observed to be highest for electrical systems, followed by sanitary systems, then heating, ventilation, and air conditioning systems, and finally life safety systems. These results provide useful information to support the resilience-based seismic design of buildings.
- 29 May 2024
- Published by Springer Nature in Architecture, Structures and Construction
- Vol. 4 (2-4) , 227-240
Open AccessPost-earthquake building services downtime distribution: a case study of the 2016 Kumamoto, Japan, earthquake
Seismic damage to building services systems, that is, mechanical, electrical, and plumbing systems in buildings related to energy and indoor environments, affects the functionality of buildings. Assessing post-earthquake functionality is useful for enhancing the seismic resilience of buildings via improved design. Such assessments require a model for predicting the time required to restore building services. This study analyzes the downtime data for 250 instances of damage to building services components caused by the 2016 Kumamoto earthquake in Japan, presumably obtained from buildings with minor or no structural damage. The objectives of this study are (1) to determine the empirical downtime distribution of building services components and (2) to assess the dependence of the downtime on explanatory variables. A survival analysis, which is a statistical technique for analyzing time-to-event data, reveals that (1) the median downtime of building services components was 90 days and, 7 months after the earthquake, the empirical non-restoration probability was approximately 32%, (2) the services type and the building use are explanatory variables having a statistically significant effect on the downtime of building services components, (3) the log-logistic regression model reasonably captures the trend of the restoration of building services components, (4) medical and welfare facilities and hotels restored building services components relatively quickly, and (5) the 7-month restoration probability was observed to be highest for electrical systems, followed by sanitary systems, then heating, ventilation, and air conditioning systems, and finally life safety systems. These results provide useful information to support the resilience-based seismic design of buildings.
- Open Access
- 4 November 2023
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 242
Methodology for probabilistic tsunami-triggered oil spill fire hazard assessment based on Natech cascading disaster modeling
- 4 November 2023
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 242
Open AccessMethodology for probabilistic tsunami-triggered oil spill fire hazard assessment based on Natech cascading disaster modeling
- 12 September 2023
- Published by Seismological Society of America (SSA) in Bulletin of the Seismological Society of America
- Vol. 113 (5) , 1902-1923
Kantō Daikasai: The Great Kantō Fire Following the 1923 Earthquake
The 1923 Great Kantō earthquake is one of the most deadly and destructive natural disasters in history. As the name connotes, fire is less considered in examinations of this event even though fire was responsible for the vast majority of death and destruction. Moreover, destruction of Tokyo by fire following an earthquake was foreseen and foretold as early as 1905, yet no actions were taken to reduce the risk. We therefore focus on fire aspects of the 1 September event with special attention to the capital Tokyo. Shaking intensities varied significantly across central Tokyo, with ∼100 ignitions distributed in all parts of the city occurring within the first hour. These rapidly grew into large fires due to the prevailing flammable wood-framed construction, high winds, and lack of firefighting water caused by breaks in water mains. However, even with adequate water, firefighters would likely still have been overwhelmed given the adverse meteorological conditions. The large fires soon merged into very large conflagrations that created their own localized high winds, further feeding the fires to the extent that fire whirls were created. The worst of these occurred in an area where many people were sheltering, causing 40,000 deaths. Even without this particularly tragic occurrence, the deaths due to fires were still greater than due to building collapse and other causes. Why the prescient warning issued years earlier went unheeded, what the social and political impact of the disaster and its aftermath was, and how fire and seismic risk reduction awareness influenced postdisaster reconstruction, are all questions we address. Although Japan since 1923 has implemented many measures to improve earthquake and postearthquake fire preparedness, the risk of fire following an earthquake remains significant in Japan as well as elsewhere.
- 12 September 2023
- Published by Seismological Society of America (SSA) in Bulletin of the Seismological Society of America
- Vol. 113 (5) , 1902-1923
Kantō Daikasai: The Great Kantō Fire Following the 1923 Earthquake
The 1923 Great Kantō earthquake is one of the most deadly and destructive natural disasters in history. As the name connotes, fire is less considered in examinations of this event even though fire was responsible for the vast majority of death and destruction. Moreover, destruction of Tokyo by fire following an earthquake was foreseen and foretold as early as 1905, yet no actions were taken to reduce the risk. We therefore focus on fire aspects of the 1 September event with special attention to the capital Tokyo. Shaking intensities varied significantly across central Tokyo, with ∼100 ignitions distributed in all parts of the city occurring within the first hour. These rapidly grew into large fires due to the prevailing flammable wood-framed construction, high winds, and lack of firefighting water caused by breaks in water mains. However, even with adequate water, firefighters would likely still have been overwhelmed given the adverse meteorological conditions. The large fires soon merged into very large conflagrations that created their own localized high winds, further feeding the fires to the extent that fire whirls were created. The worst of these occurred in an area where many people were sheltering, causing 40,000 deaths. Even without this particularly tragic occurrence, the deaths due to fires were still greater than due to building collapse and other causes. Why the prescient warning issued years earlier went unheeded, what the social and political impact of the disaster and its aftermath was, and how fire and seismic risk reduction awareness influenced postdisaster reconstruction, are all questions we address. Although Japan since 1923 has implemented many measures to improve earthquake and postearthquake fire preparedness, the risk of fire following an earthquake remains significant in Japan as well as elsewhere.
- Open Access
- 4 January 2023
- Published by Springer Nature in Natural Hazards
- Vol. 116 (3) , 3165-3200
Probabilistic urban cascading multi-hazard risk assessment methodology for ground shaking and post-earthquake fires
A probabilistic methodology is presented for assessing cascading multi-hazard risk for ground shaking and post-earthquake fires at a regional scale. The proposed methodology focuses on direct economic losses to buildings caused by the combined effect of ground shaking and post-earthquake fires and evaluates the exceedance probability of the regional shaking–fire losses in a predefined future time period by comprehensively considering the effects of various uncertain factors on the losses via Monte Carlo simulations. Probabilistic seismic risk assessments are extended by integrating post-earthquake fire models with seismic activity models, ground motion prediction equations, and seismic fragility functions. The fire models include post-earthquake ignition models, a weather model, a physics-based urban fire spread model, and a fire brigade response model. This integrated modeling enables the incorporation of the following uncertain factors with causal relationships into the assessments: earthquake occurrence, ground motion intensity distribution, damage to buildings resulting from ground shaking, post-earthquake ignition occurrence and occupant firefighting, weather condition, fire brigade response time including time to detection, and damage to buildings resulting from post-earthquake urban fire spread. To demonstrate the methodology, a realistic case study is conducted for a historical urban area with closely spaced wooden buildings in Kyoto, Japan, focusing on possible large earthquakes along major active faults. Contrary to conventional single-hazard approaches, the results highlight the impact of multi-hazard consideration on risk assessments. This indicates that the methodology can be a useful tool for more appropriately understanding earthquake risk and promoting risk-informed decision-making in urban communities for risk reduction.
- 4 January 2023
- Published by Springer Nature in Natural Hazards
- Vol. 116 (3) , 3165-3200
Open AccessProbabilistic urban cascading multi-hazard risk assessment methodology for ground shaking and post-earthquake fires
A probabilistic methodology is presented for assessing cascading multi-hazard risk for ground shaking and post-earthquake fires at a regional scale. The proposed methodology focuses on direct economic losses to buildings caused by the combined effect of ground shaking and post-earthquake fires and evaluates the exceedance probability of the regional shaking–fire losses in a predefined future time period by comprehensively considering the effects of various uncertain factors on the losses via Monte Carlo simulations. Probabilistic seismic risk assessments are extended by integrating post-earthquake fire models with seismic activity models, ground motion prediction equations, and seismic fragility functions. The fire models include post-earthquake ignition models, a weather model, a physics-based urban fire spread model, and a fire brigade response model. This integrated modeling enables the incorporation of the following uncertain factors with causal relationships into the assessments: earthquake occurrence, ground motion intensity distribution, damage to buildings resulting from ground shaking, post-earthquake ignition occurrence and occupant firefighting, weather condition, fire brigade response time including time to detection, and damage to buildings resulting from post-earthquake urban fire spread. To demonstrate the methodology, a realistic case study is conducted for a historical urban area with closely spaced wooden buildings in Kyoto, Japan, focusing on possible large earthquakes along major active faults. Contrary to conventional single-hazard approaches, the results highlight the impact of multi-hazard consideration on risk assessments. This indicates that the methodology can be a useful tool for more appropriately understanding earthquake risk and promoting risk-informed decision-making in urban communities for risk reduction.
- Open Access
- 4 July 2022
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 22 (4) , 2123-2142
Investigation of damage to fire protection systems in buildings due to the 2016 Kumamoto earthquake: derivation of damage models for post-earthquake fire risk assessments
Post-earthquake fire safety is an important functional requirement of seismic-resilient buildings and depends on seismic damage to fire protection systems. Probabilistic fire risk assessments are useful in ensuring safety and consider the post-earthquake reliability of fire protection systems. This study therefore investigated damage to fire protection systems due to the 2016 Kumamoto earthquake through a questionnaire survey among hospitals to collect data available for modeling the post-earthquake reliability. Ten types of component of a fire protection system were surveyed: emergency generators, fire detectors, water tanks used for firefighting, fire pumps, sprinkler heads, indoor fire hydrant boxes, fixed glass smoke curtains, fire doors, fire shutters, and fire exit signs. The data show that there was much damage to fire detectors, sprinkler heads, fixed glass smoke curtains, and fire doors. Zero-inflated Poisson regression analysis was conducted to derive statistical damage models that describe the association of building response quantities with the number of instances of damage. Results of a case study using the models show that building shaking exceeding a peak response acceleration of 10 m/s2 may reduce the probability of successful functioning to below 40% for a sprinkler system and to below 90% for a smoke-activated door system.
- 4 July 2022
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 22 (4) , 2123-2142
Open AccessInvestigation of damage to fire protection systems in buildings due to the 2016 Kumamoto earthquake: derivation of damage models for post-earthquake fire risk assessments
Post-earthquake fire safety is an important functional requirement of seismic-resilient buildings and depends on seismic damage to fire protection systems. Probabilistic fire risk assessments are useful in ensuring safety and consider the post-earthquake reliability of fire protection systems. This study therefore investigated damage to fire protection systems due to the 2016 Kumamoto earthquake through a questionnaire survey among hospitals to collect data available for modeling the post-earthquake reliability. Ten types of component of a fire protection system were surveyed: emergency generators, fire detectors, water tanks used for firefighting, fire pumps, sprinkler heads, indoor fire hydrant boxes, fixed glass smoke curtains, fire doors, fire shutters, and fire exit signs. The data show that there was much damage to fire detectors, sprinkler heads, fixed glass smoke curtains, and fire doors. Zero-inflated Poisson regression analysis was conducted to derive statistical damage models that describe the association of building response quantities with the number of instances of damage. Results of a case study using the models show that building shaking exceeding a peak response acceleration of 10 m/s2 may reduce the probability of successful functioning to below 40% for a sprinkler system and to below 90% for a smoke-activated door system.