Yuki Tosaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuki Tosaki has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
Kimikazu Sasa
12 shared publicationsTsutomu Takahashi
12 shared publicationsYasuo Nagashima
11 shared publications- Hiroshi Matsumura
High Energy Accelerator Research Organization (KEK)
8 shared publications Keisuke Sueki
6 shared publicationsKotaro Bessho
Radiation Science Center, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan
6 shared publications
Latest Publications
- Open Access
- 18 March 2025
- Published by Copernicus GmbH
Characterizing Fault Zone Hydrology Using a Coupled Geophysical and Modeling Approach
Fault zones can play a critical role in controlling small to large scale groundwater flow. Extensive studies have focused on permeability variations along faults in terms of conduit or barrier function for deep groundwater flow. However, little attempt has been made to characterize the hydrologic functions of near-surface fault zones.When exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, acting as a near-surface recharge or discharge zone, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of such a fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study presents a multiphysics coupled strategy to characterize the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The multiphysics approach consists of 5 consecutive steps:Electrical Resistivity Tomography (ERT) Survey: A 3.8 km-long profile across the fault zone, with 20 m electrode spacing. Self-Potential (SP) survey: Conducted along the ERT profile. Rock property characterization: A 160 m deep borehole was drilled in the fault zone and physical properties were measured. Groundwater flow simulation of the fault zone: Using hydrogeological data, measured rock properties and a 3D geological model. Model evaluation: Post-processing of the groundwater flow simulation to calculate synthetic electrical resistivity and self-potential responses and comparison with observed field data. The fault zone is identified by a sharp structural change between conductive and resistive geologic units, which also exhibit a small but shifted SP jump (+20 mV) signal. Our model evaluation process reproduces the entire ERT and SP data.This newly proposed multiphysics approach offers a robust tool for monitoring groundwater flow in geologically complex regions, with applications in radioactive waste disposal safety, groundwater contamination management, and understanding hydrogeologic processes in tectonically active areas.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- 18 March 2025
- Published by Copernicus GmbH
Open AccessCharacterizing Fault Zone Hydrology Using a Coupled Geophysical and Modeling Approach
Fault zones can play a critical role in controlling small to large scale groundwater flow. Extensive studies have focused on permeability variations along faults in terms of conduit or barrier function for deep groundwater flow. However, little attempt has been made to characterize the hydrologic functions of near-surface fault zones.When exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, acting as a near-surface recharge or discharge zone, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of such a fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study presents a multiphysics coupled strategy to characterize the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The multiphysics approach consists of 5 consecutive steps:Electrical Resistivity Tomography (ERT) Survey: A 3.8 km-long profile across the fault zone, with 20 m electrode spacing. Self-Potential (SP) survey: Conducted along the ERT profile. Rock property characterization: A 160 m deep borehole was drilled in the fault zone and physical properties were measured. Groundwater flow simulation of the fault zone: Using hydrogeological data, measured rock properties and a 3D geological model. Model evaluation: Post-processing of the groundwater flow simulation to calculate synthetic electrical resistivity and self-potential responses and comparison with observed field data. The fault zone is identified by a sharp structural change between conductive and resistive geologic units, which also exhibit a small but shifted SP jump (+20 mV) signal. Our model evaluation process reproduces the entire ERT and SP data.This newly proposed multiphysics approach offers a robust tool for monitoring groundwater flow in geologically complex regions, with applications in radioactive waste disposal safety, groundwater contamination management, and understanding hydrogeologic processes in tectonically active areas.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Coupled multiphysics approach to characterize groundwater flow system around a near-surface fault zone
Fault zones intensively disturb local hydrogeologic structures, and, consequently, can play a critical role in governing small to large-scale groundwater flow. Extensive studies have focused on the permeability variation along faults in the light of the conduit or barrier function for the deep groundwater flow. However, little attempt has been made to characterize the hydrological functions of near-surface fault zone.Exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, which functions as a recharge or discharge zone at the near surface, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of near-surface fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study proposes a multiphysics coupled strategy to understand the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The proposed multiphysics approach consists of 5 successive steps:2-D Electrical Resistivity Tomography (ERT) Survey: A 2.3 km-long profile crossing the fault zone, consisting of 7 roll-along surveys with a 6-m electrode spacing. Self-Potential Survey: Conducted along the 2.3 km ERT profile. Rock Property Characterization: A 80 m deep borehole was drilled in the fault zone and physical properties were measured. 3-D Groundwater Flow Simulation of the Fault Zone: Utilizing areal hydrogeological data, measured rock properties, and geophysical imaging. Model Validation Process: Using the results from the groundwater flow simulation, electrical conductivity and self-potential responses were calculated, and compared with observed field data. Preliminary results successfully reproduce the overall resistivity signature and the self-potential anomaly (+35 mV) in the fault zone, attributed to local groundwater upwelling. This newly proposed multiphysics approach could be an essential tool to evaluate the groundwater flow in a region including large-size fault zone, which is important for radioactive waste disposal. Furthermore, this approach could also be effective in capturing the local fluid flow circulation for a variety of applications.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessCoupled multiphysics approach to characterize groundwater flow system around a near-surface fault zone
Fault zones intensively disturb local hydrogeologic structures, and, consequently, can play a critical role in governing small to large-scale groundwater flow. Extensive studies have focused on the permeability variation along faults in the light of the conduit or barrier function for the deep groundwater flow. However, little attempt has been made to characterize the hydrological functions of near-surface fault zone.Exposed to atmospheric conditions, fault zones are further disturbed by stress relief and chemical weathering, modifying their structure and generally increasing their permeability. Consequently, the fault zone, which functions as a recharge or discharge zone at the near surface, exerts a non-negligible influence on groundwater flow. However, identifying the hydrological function of near-surface fault zone remains challenging when relying solely on conventional, often non-integrated, geophysical or hydrological investigation approaches.This study proposes a multiphysics coupled strategy to understand the groundwater flow regime around near-surface fault zone. The proposed approach is applied to an active reverse fault zone in Kamikita Plain, NE Japan, which extends for 30 km within the recharge zone of the catchment.The proposed multiphysics approach consists of 5 successive steps:2-D Electrical Resistivity Tomography (ERT) Survey: A 2.3 km-long profile crossing the fault zone, consisting of 7 roll-along surveys with a 6-m electrode spacing. Self-Potential Survey: Conducted along the 2.3 km ERT profile. Rock Property Characterization: A 80 m deep borehole was drilled in the fault zone and physical properties were measured. 3-D Groundwater Flow Simulation of the Fault Zone: Utilizing areal hydrogeological data, measured rock properties, and geophysical imaging. Model Validation Process: Using the results from the groundwater flow simulation, electrical conductivity and self-potential responses were calculated, and compared with observed field data. Preliminary results successfully reproduce the overall resistivity signature and the self-potential anomaly (+35 mV) in the fault zone, attributed to local groundwater upwelling. This newly proposed multiphysics approach could be an essential tool to evaluate the groundwater flow in a region including large-size fault zone, which is important for radioactive waste disposal. Furthermore, this approach could also be effective in capturing the local fluid flow circulation for a variety of applications.Acknowledgements: Main part of this research project has been conducted as the regulatory supporting research funded by the Secretariat of the Nuclear Regulation Authority, Japan.
- Open Access
- 29 February 2024
- Published by Japanese Association of Groundwater Hydrology in Journal of Groundwater Hydrology
- Vol. 66 (1) , 43-54
Visit to valuable water springs (144) Valuable springs in Akita and Yamagata prefectures — including springs revisited
- 29 February 2024
- Published by Japanese Association of Groundwater Hydrology in Journal of Groundwater Hydrology
- Vol. 66 (1) , 43-54
Open AccessVisit to valuable water springs (144) Valuable springs in Akita and Yamagata prefectures — including springs revisited
- 25 August 2022
- Published by Japanese Association of Hydrological Sciences in Journal of Japanese Association of Hydrological Sciences
- Vol. 52 (2) , 61-64
Drilling surveys for verification of groundwater flow system
- 25 August 2022
- Published by Japanese Association of Hydrological Sciences in Journal of Japanese Association of Hydrological Sciences
- Vol. 52 (2) , 61-64
Drilling surveys for verification of groundwater flow system
- Open Access
- 23 July 2020
- Published by Springer Nature in Earth, Planets and Space
- Vol. 72 (1) , 1-20
Original composition and formation process of slab-derived deep brine from Kashio mineral spring in central Japan
Brine samples from the wells in the Kashio mineral spring (an “Arima-type” hot spring at Ooshika-Mura, central Japan) were analyzed to determine the original chemical and isotopic compositions of the deep brine end-member before its dilution by meteoric water and to elucidate the origin of the end-member. The trends of variation between Cl, δD, and δ18O indicated the existence of a two-component mixing system and a systematic variation in the mixing ratio, which were mentioned in previous studies. By carefully tracking the variation in tritium (3H) and atmospheric noble gas in the brine, the Cl concentration in the end-member was determined to be 24,000 mg/L. This value is consistent with the result of previous studies. Based on the estimated composition and other related data, we inferred that the end-member originated from slab-derived fluid, which in turn may have undergone oxygen isotope exchange reactions with minerals. Although both the Arima and Kashio brines are considered to be derived from fluid dehydrated from the Philippine Sea slab, the chemical and isotopic compositions of the Kashio end-member are different from those of the Arima end-member. In particular, the Kashio end-member is characterized by low Cl concentration (~ 40% lower than that in the Arima end-member), low hydrogen isotope ratio, and low 3He/4He ratio (1.4 Ra). These results indicate that the chemical and isotopic compositions of the slab-derived fluid are different for each location. The significant difference in δD could reflect the difference in the dehydration depth. Finally, the low temperature and relatively low 3He/4He ratio of the brine end-member could be explained by its long residence time within the crust.
- 23 July 2020
- Published by Springer Nature in Earth, Planets and Space
- Vol. 72 (1) , 1-20
Open AccessOriginal composition and formation process of slab-derived deep brine from Kashio mineral spring in central Japan
Brine samples from the wells in the Kashio mineral spring (an “Arima-type” hot spring at Ooshika-Mura, central Japan) were analyzed to determine the original chemical and isotopic compositions of the deep brine end-member before its dilution by meteoric water and to elucidate the origin of the end-member. The trends of variation between Cl, δD, and δ18O indicated the existence of a two-component mixing system and a systematic variation in the mixing ratio, which were mentioned in previous studies. By carefully tracking the variation in tritium (3H) and atmospheric noble gas in the brine, the Cl concentration in the end-member was determined to be 24,000 mg/L. This value is consistent with the result of previous studies. Based on the estimated composition and other related data, we inferred that the end-member originated from slab-derived fluid, which in turn may have undergone oxygen isotope exchange reactions with minerals. Although both the Arima and Kashio brines are considered to be derived from fluid dehydrated from the Philippine Sea slab, the chemical and isotopic compositions of the Kashio end-member are different from those of the Arima end-member. In particular, the Kashio end-member is characterized by low Cl concentration (~ 40% lower than that in the Arima end-member), low hydrogen isotope ratio, and low 3He/4He ratio (1.4 Ra). These results indicate that the chemical and isotopic compositions of the slab-derived fluid are different for each location. The significant difference in δD could reflect the difference in the dehydration depth. Finally, the low temperature and relatively low 3He/4He ratio of the brine end-member could be explained by its long residence time within the crust.
- 1 January 2017
- Published by Geochemical Society of Japan in GEOCHEMICAL JOURNAL
- Vol. 51 (3) , 263-275
Deep incursion of seawater into the Hiroshima Granites during the Holocene transgression: Evidence from 36Cl age of saline groundwater in the Hiroshima area, Japan
- 1 January 2017
- Published by Geochemical Society of Japan in GEOCHEMICAL JOURNAL
- Vol. 51 (3) , 263-275
Deep incursion of seawater into the Hiroshima Granites during the Holocene transgression: Evidence from 36Cl age of saline groundwater in the Hiroshima area, Japan
- Open Access
- 1 January 2014
- Published by Springer Nature in Earth, Planets and Space
- Vol. 66 (1) , 131
Groundwater, possibly originated from subducted sediments, in Joban and Hamadori areas, southern Tohoku, Japan
- 1 January 2014
- Published by Springer Nature in Earth, Planets and Space
- Vol. 66 (1) , 131
Open AccessGroundwater, possibly originated from subducted sediments, in Joban and Hamadori areas, southern Tohoku, Japan
- Open Access
- 1 April 2012
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 106, 73-80
Measurement of the 36Cl deposition flux in central Japan: natural background levels and seasonal variability
- 1 April 2012
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 106, 73-80
Open AccessMeasurement of the 36Cl deposition flux in central Japan: natural background levels and seasonal variability
- 30 April 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (9) , 3125-3132
Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study
A first international 36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with 36Cl/Cl ratios at the 10−11, 10−12, and 10−13 level shows no difference in the sense of simple statistical significance. However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following subsequent remeasurement and reanalysis of the data from some AMS facilities, the round-robin data indicate that 36Cl/Cl data from two individual AMS laboratories can differ by up to 17%. Thus, the demand for further work on harmonising the 36Cl-system on a worldwide scale and enlarging the improvement of measurements is obvious.
- 30 April 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (9) , 3125-3132
Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study
A first international 36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with 36Cl/Cl ratios at the 10−11, 10−12, and 10−13 level shows no difference in the sense of simple statistical significance. However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following subsequent remeasurement and reanalysis of the data from some AMS facilities, the round-robin data indicate that 36Cl/Cl data from two individual AMS laboratories can differ by up to 17%. Thus, the demand for further work on harmonising the 36Cl-system on a worldwide scale and enlarging the improvement of measurements is obvious.