Jian Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jian Chen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Abdelaziz Mohamed
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
4 shared publications - Andres Annuk
Institute of Forestry and Engineering, Estonian University of Life Sciences, 51006 Tartu, Estonia
3 shared publications - Tao Jin
College of Electrical Engineering and Automation Fuzhou University Fuzhou China
2 shared publications - Udaya Dampage
Faculty of Engineering, Kotelawala Defence University, Ratmalana 10390, Sri Lanka
2 shared publications - Khalid Abdulaziz Alnowibet
Statistics and Operations Research Department, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication - Mostafa Rezaei
Department of Industrial Engineering, Yazd University, Yazd, Iran
1 shared publication
Latest Publications
- Open Access
- 24 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 3841
Investigating the Impact of Wind Power Integration on Damping Characteristics of Low Frequency Oscillations in Power Systems
This paper investigates the impact of doubly-fed induction generator (DFIG) wind farms on system stability in multi-generator power systems with low-frequency oscillations (LFOs). To this end, this paper establishes the interconnection model of the equivalent generators and derives the system state equation. On this basis, an updated system state equation of the new power system with integrated wind power is further derived. Then, according to the updated system state equation, the impact factors that cause changes in the system damping characteristics are presented. The IEEE two-area four-machine power system is used as a simulation model in which the LFOs occur. The simulation results demonstrate that the connection of wind power to the power feeding area (PFA) increases the damping ratio of the dominant mode of inter-area oscillation from −0.0263 to −0.0107, which obviously improves the system stability. Furthermore, the wind power integration into PFA, as the connection distance of the wind power increases, gradually decreases the damping ratio of the dominant mode of the inter-area oscillation to −0.0236, approaching that of no wind power in the system. Meanwhile, with the increase in the wind power output capacity, the damping ratio of the dominant mode of the intra-area and inter-area oscillation increases, and the maximum damping ratios reach 0.1337 and 0.0233, respectively.
- 24 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 3841
Open AccessInvestigating the Impact of Wind Power Integration on Damping Characteristics of Low Frequency Oscillations in Power Systems
This paper investigates the impact of doubly-fed induction generator (DFIG) wind farms on system stability in multi-generator power systems with low-frequency oscillations (LFOs). To this end, this paper establishes the interconnection model of the equivalent generators and derives the system state equation. On this basis, an updated system state equation of the new power system with integrated wind power is further derived. Then, according to the updated system state equation, the impact factors that cause changes in the system damping characteristics are presented. The IEEE two-area four-machine power system is used as a simulation model in which the LFOs occur. The simulation results demonstrate that the connection of wind power to the power feeding area (PFA) increases the damping ratio of the dominant mode of inter-area oscillation from −0.0263 to −0.0107, which obviously improves the system stability. Furthermore, the wind power integration into PFA, as the connection distance of the wind power increases, gradually decreases the damping ratio of the dominant mode of the inter-area oscillation to −0.0236, approaching that of no wind power in the system. Meanwhile, with the increase in the wind power output capacity, the damping ratio of the dominant mode of the intra-area and inter-area oscillation increases, and the maximum damping ratios reach 0.1337 and 0.0233, respectively.
- Open Access
- 1 November 2021
- Published by Elsevier in Energy Strategy Reviews
- Vol. 38
An effective distributed approach based machine learning for energy negotiation in networked microgrids
- 1 November 2021
- Published by Elsevier in Energy Strategy Reviews
- Vol. 38
Open AccessAn effective distributed approach based machine learning for energy negotiation in networked microgrids
- Open Access
- 25 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 9972
A Multi-Layer Security Scheme for Mitigating Smart Grid Vulnerability against Faults and Cyber-Attacks
To comply with electric power grid automation strategies, new cyber-security protocols and protection are required. What we now experience is a new type of protection against new disturbances namely cyber-attacks. In the same vein, the impact of disturbances arising from faults or cyber-attacks should be surveyed by network vulnerability criteria alone. It is clear that the diagnosis of vulnerable points protects the power grid against disturbances that would inhibit outages such as blackouts. So, the first step is determining the network vulnerable points, and then proposing a support method to deal with these outages. This research proposes a comprehensive approach to deal with outages by determining network vulnerable points due to physical faults and cyber-attacks. The first point, the network vulnerable points against network faults are covered by microgrids. As the second one, a new cyber-security protocol named multi-layer security is proposed in order to prevent targeted cyber-attacks. The first layer is a cyber-security-based blockchain method that plays a general role. The second layer is a cyber-security-based reinforcement-learning method, which supports the vulnerable points by monitoring data. On the other hand, the trend of solving problems becomes routine when no ambiguity arises in different sections of the smart grid, while it is far from a big network’s realities. Hence, the impact of uncertainty parameters on the proposed framework needs to be considered. Accordingly, the unscented transform method is modeled in this research. The simulation results illustrate that applying such a comprehensive approach can greatly pull down the probability of blackouts.
- 25 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (21) , 9972
Open AccessA Multi-Layer Security Scheme for Mitigating Smart Grid Vulnerability against Faults and Cyber-Attacks
To comply with electric power grid automation strategies, new cyber-security protocols and protection are required. What we now experience is a new type of protection against new disturbances namely cyber-attacks. In the same vein, the impact of disturbances arising from faults or cyber-attacks should be surveyed by network vulnerability criteria alone. It is clear that the diagnosis of vulnerable points protects the power grid against disturbances that would inhibit outages such as blackouts. So, the first step is determining the network vulnerable points, and then proposing a support method to deal with these outages. This research proposes a comprehensive approach to deal with outages by determining network vulnerable points due to physical faults and cyber-attacks. The first point, the network vulnerable points against network faults are covered by microgrids. As the second one, a new cyber-security protocol named multi-layer security is proposed in order to prevent targeted cyber-attacks. The first layer is a cyber-security-based blockchain method that plays a general role. The second layer is a cyber-security-based reinforcement-learning method, which supports the vulnerable points by monitoring data. On the other hand, the trend of solving problems becomes routine when no ambiguity arises in different sections of the smart grid, while it is far from a big network’s realities. Hence, the impact of uncertainty parameters on the proposed framework needs to be considered. Accordingly, the unscented transform method is modeled in this research. The simulation results illustrate that applying such a comprehensive approach can greatly pull down the probability of blackouts.
- Open Access
- 3 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 7244-7255
An Adaptive Matrix Pencil Algorithm Based-Wavelet Soft-Threshold Denoising for Analysis of Low Frequency Oscillation in Power Systems
One of the main reasons that affecting the stability of power systems is low frequency oscillation (LFO). The existence of noise influences the accuracy of LFO mode identification extracted from wide-area measurement system (WAMS). The wavelet threshold de-noising is widely used in signal processing. In this paper, wavelet soft threshold is illustrated to attenuate the noise of LFO signal, the optimal wavelet basis and decomposition level for de-noising LFO signal with noise are obtained and verified by experiments. Following the signal de-noising, an improved Matrix Pencil (MP) algorithm is used for mode identification of LFO. This improvement particularly lies in the ratio of adjacent singular entropy increment difference (RASEID) designed as an adaptive order determination method in the MP algorithm proposed in the paper. RASEID not only makes the MP algorithm adaptive, but also enhances the stability of the order determination in the mode identification process. The proposed method ensures the accuracy of mode identification with lower sensitivity to noise interference. Finally, the validity of the proposed method is verified by three cases studies. The first study is on the analysis of synthetic signal typically performed in many literatures. The second study is to identify the mode of active power LFO signal which is generated by IEEE four-generator and two-area system given with disturbance on RT-LAB experimental platform. The third study is the oscillation analysis of the actual LFO data in the North American power grid. The results validate the feasibility of the proposed method for mode identification of noisy LFO.
- 3 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 7244-7255
Open AccessAn Adaptive Matrix Pencil Algorithm Based-Wavelet Soft-Threshold Denoising for Analysis of Low Frequency Oscillation in Power Systems
One of the main reasons that affecting the stability of power systems is low frequency oscillation (LFO). The existence of noise influences the accuracy of LFO mode identification extracted from wide-area measurement system (WAMS). The wavelet threshold de-noising is widely used in signal processing. In this paper, wavelet soft threshold is illustrated to attenuate the noise of LFO signal, the optimal wavelet basis and decomposition level for de-noising LFO signal with noise are obtained and verified by experiments. Following the signal de-noising, an improved Matrix Pencil (MP) algorithm is used for mode identification of LFO. This improvement particularly lies in the ratio of adjacent singular entropy increment difference (RASEID) designed as an adaptive order determination method in the MP algorithm proposed in the paper. RASEID not only makes the MP algorithm adaptive, but also enhances the stability of the order determination in the mode identification process. The proposed method ensures the accuracy of mode identification with lower sensitivity to noise interference. Finally, the validity of the proposed method is verified by three cases studies. The first study is on the analysis of synthetic signal typically performed in many literatures. The second study is to identify the mode of active power LFO signal which is generated by IEEE four-generator and two-area system given with disturbance on RT-LAB experimental platform. The third study is the oscillation analysis of the actual LFO data in the North American power grid. The results validate the feasibility of the proposed method for mode identification of noisy LFO.