Andrei Gusarov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andrei Gusarov has a total of 181 co-authors. Here are the top co-authors by number of shared publications:
- Patrice Mégret
University of Mons, Mons, Belgium
19 shared publications - Francis Berghmans
Vrije Universiteit Brussel
15 shared publications - Marc Wuilpart
Univ. de Mons (Belgium)
7 shared publications Marc Wuilpart
6 shared publications- Kyriacos Kalli
Cyprus University of Technology
5 shared publications M. Wuilpart
Univ Mons, Electromanetism & Telecommun Unit, Bd Dolez 31, B-7000 Mons, Belgium
5 shared publications
Latest Publications
- Open Access
Gamma Irradiation Effect on the Verdet Constant of Standard Single-Mode Ge-Doped Optical Fibre
Optical fibres are considered for applications in various nuclear environments in the presence of radiation exposure. Under irradiation, the properties of the optical fibres are modified. In the present paper we investigate the influence of gamma radiation on the magneto-optical properties of the Corning SMF-28e optical fibre. The stability of the Verdet constant is an important requirement for performing current measurements under radiation, for example, in magnetic fusion installations during nuclear (deuterium–tritium) plasma operation, where radiation at MGy dose levels can be accumulated. Our results demonstrate that radiation-induced changes in the Verdet constant are within its measurement accuracy (0.56%) for gamma radiation doses up to 770 kGy.
Open AccessGamma Irradiation Effect on the Verdet Constant of Standard Single-Mode Ge-Doped Optical Fibre
Optical fibres are considered for applications in various nuclear environments in the presence of radiation exposure. Under irradiation, the properties of the optical fibres are modified. In the present paper we investigate the influence of gamma radiation on the magneto-optical properties of the Corning SMF-28e optical fibre. The stability of the Verdet constant is an important requirement for performing current measurements under radiation, for example, in magnetic fusion installations during nuclear (deuterium–tritium) plasma operation, where radiation at MGy dose levels can be accumulated. Our results demonstrate that radiation-induced changes in the Verdet constant are within its measurement accuracy (0.56%) for gamma radiation doses up to 770 kGy.
- Open Access
Assessment of Neutron Radiation Effects on the Fiber Optics Current Sensor Performance During JET DTE2 Experimental Campaign
Fibre Optics Current Sensor (FOCS) will be used at ITER to perform plasma current measurement during quasi-steady state D-T plasma operation. Effects of the tokamak harsh environment on the FOCS performance must be evaluated to predict possible failure modes and relevant mitigation measures. The influence of nuclear radiation with the significant flux of 14 MeV neutrons is of specific concern. This problem was addressed by operating the FOCS during D-T campaign at JET (DTE2). In the present report experimental results are presented and analysed. These results indicate that FOCS will effectively perform current measurements during ITER nuclear operation.
Open AccessAssessment of Neutron Radiation Effects on the Fiber Optics Current Sensor Performance During JET DTE2 Experimental Campaign
Fibre Optics Current Sensor (FOCS) will be used at ITER to perform plasma current measurement during quasi-steady state D-T plasma operation. Effects of the tokamak harsh environment on the FOCS performance must be evaluated to predict possible failure modes and relevant mitigation measures. The influence of nuclear radiation with the significant flux of 14 MeV neutrons is of specific concern. This problem was addressed by operating the FOCS during D-T campaign at JET (DTE2). In the present report experimental results are presented and analysed. These results indicate that FOCS will effectively perform current measurements during ITER nuclear operation.
- Top Cited PapersOpen Access
- 4 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 982-1020
Overview of Radiation Effects on Silica-Based Optical Fibers and Fiber Sensors
This review focuses on silica-based optical fibers, guiding light through the total internal reflection mechanism, that are currently used in telecommunications and sensor networks. Section I briefly introduces the fiber and fiber sensor technologies. Section II presents their various applications in radiation environments. In section III, the radiation effects on optical fibers are explained, first at a microscopic scale, with the description of point defects generated by irradiation. Then, the macroscopic consequences of the appearance of these point defects are discussed, in particular the phenomena of radiation-induced attenuation (RIA), radiation-induced emission (RIE) and radiation-induced refractive index change (RIRIC). RIA impacts nearly all applications under irradiation. We then detail the various parameters, intrinsic or extrinsic to the optical fibers that influence their amplitudes and kinetics. This improved knowledge paved the way for the radiation hardening of optical fibers through various approaches, either at material, component or system levels, that are described in section IV. Recent advances are presented for passive and for active rare-earth doped optical fibers and systems. Then, the use of fiber optic sensors is introduced, starting in section V with the latest advances in radiation-hardened point or distributed sensors. Then, the potential of this technology for radiation detection, beam instrumentation and dosimetry applications is assessed in section VI. Finally, the future prospects and the main challenges to be met in order to accelerate the implementation of this technology in the harshest environments are discussed.
- 4 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 982-1020
Top Cited PapersOpen AccessOverview of Radiation Effects on Silica-Based Optical Fibers and Fiber Sensors
This review focuses on silica-based optical fibers, guiding light through the total internal reflection mechanism, that are currently used in telecommunications and sensor networks. Section I briefly introduces the fiber and fiber sensor technologies. Section II presents their various applications in radiation environments. In section III, the radiation effects on optical fibers are explained, first at a microscopic scale, with the description of point defects generated by irradiation. Then, the macroscopic consequences of the appearance of these point defects are discussed, in particular the phenomena of radiation-induced attenuation (RIA), radiation-induced emission (RIE) and radiation-induced refractive index change (RIRIC). RIA impacts nearly all applications under irradiation. We then detail the various parameters, intrinsic or extrinsic to the optical fibers that influence their amplitudes and kinetics. This improved knowledge paved the way for the radiation hardening of optical fibers through various approaches, either at material, component or system levels, that are described in section IV. Recent advances are presented for passive and for active rare-earth doped optical fibers and systems. Then, the use of fiber optic sensors is introduced, starting in section V with the latest advances in radiation-hardened point or distributed sensors. Then, the potential of this technology for radiation detection, beam instrumentation and dosimetry applications is assessed in section VI. Finally, the future prospects and the main challenges to be met in order to accelerate the implementation of this technology in the harshest environments are discussed.
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , P09022
Effect of gamma-radiation on the transmission and return losses of FC/APC connectors
The Fibre Optics Current Sensor (FOCS) installed at ITER will use optical fibres to perform plasma current measurements based on the Faraday effect. A connection between the sensing fibre placed on the Vacuum Vessel and the fibre guiding the signal to the data-acquisition hardware will be required. Because of practical reasons, this link contains FC/APC connectors, which guarantee the low return loss required for normal operation of the FOCS. The connectors will be located in the port cell area and will be subject to high levels of nuclear radiation. Radiation may influence both transmission and return losses of the FC/APC connectors and, as a result, degrade the FOCS performance. To address the problem, several FC/APC connectors were exposed to Co60 gamma radiation up to a 550 kGy dose. Transmission through the connectors was monitored during irradiation. The return loss of mated FC/APC connectors was measured before and after irradiation. It was found that radiation-induced changes of both transmission and reflection parameters are acceptable for the FOCS at ITER.
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , P09022
Effect of gamma-radiation on the transmission and return losses of FC/APC connectors
The Fibre Optics Current Sensor (FOCS) installed at ITER will use optical fibres to perform plasma current measurements based on the Faraday effect. A connection between the sensing fibre placed on the Vacuum Vessel and the fibre guiding the signal to the data-acquisition hardware will be required. Because of practical reasons, this link contains FC/APC connectors, which guarantee the low return loss required for normal operation of the FOCS. The connectors will be located in the port cell area and will be subject to high levels of nuclear radiation. Radiation may influence both transmission and return losses of the FC/APC connectors and, as a result, degrade the FOCS performance. To address the problem, several FC/APC connectors were exposed to Co60 gamma radiation up to a 550 kGy dose. Transmission through the connectors was monitored during irradiation. The return loss of mated FC/APC connectors was measured before and after irradiation. It was found that radiation-induced changes of both transmission and reflection parameters are acceptable for the FOCS at ITER.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (18) , 6262-6268
Temperature and RH Response of Few-Mode Polymer CYTOP/XYLEX FBGs: Gamma-Radiation Tuning of Sensing Properties
We consider thermal and hygroscopic properties of polymer fiber Bragg gratings (PFBGs) inscribed in a few-mode perfluorinated CYTOP fiber with XYLEX protection overclad. The PFBGs were inscribed with a femtosecond laser using a plane-by-plane technique. The influence of γ-radiation treatment on PFBG temperature (T) and relative humidity (RH) sensitivities is presented. The RH sensitivity increases with received dose from 13.3 pm/%RH for pristine PFBG up to 56.8 pm/%RH for the dose of 520 kGy. The T sensitivity decreases from 19.6 pm/° down to -38.9 pm/° correspondingly. Irradiating the PFBGs with optimal γ-radiation dose (≈200 kGy) enables RH sensing with no T cross-sensitivity. The RH response time of PFBGs and its dependence on T and received γ-radiation dose is considered as well. Finally, the impact of RH on PFBGs reflection power is presented.
- 27 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (18) , 6262-6268
Temperature and RH Response of Few-Mode Polymer CYTOP/XYLEX FBGs: Gamma-Radiation Tuning of Sensing Properties
We consider thermal and hygroscopic properties of polymer fiber Bragg gratings (PFBGs) inscribed in a few-mode perfluorinated CYTOP fiber with XYLEX protection overclad. The PFBGs were inscribed with a femtosecond laser using a plane-by-plane technique. The influence of γ-radiation treatment on PFBG temperature (T) and relative humidity (RH) sensitivities is presented. The RH sensitivity increases with received dose from 13.3 pm/%RH for pristine PFBG up to 56.8 pm/%RH for the dose of 520 kGy. The T sensitivity decreases from 19.6 pm/° down to -38.9 pm/° correspondingly. Irradiating the PFBGs with optimal γ-radiation dose (≈200 kGy) enables RH sensing with no T cross-sensitivity. The RH response time of PFBGs and its dependence on T and received γ-radiation dose is considered as well. Finally, the impact of RH on PFBGs reflection power is presented.
- Open Access
Performance Enhancement of the Polarimetric Fibre Optical Current Sensor at JET Using Polarisation Optimisation
To achieve optimal operation of the polarimetry-based FOCS, the light polarisation state at the input of the sensing fibre part must be close to a linear one. In the case of a FOCS deployed on a tokamak, the Joint European Torus (JET) in the present work, the long fibre optics link between the laser source and the sensing fibre modifies the polarisation in an unpredictable way, making it unclear which source polarisation state is to be set. A method for performing the necessary polarisation adjustment in a systematic way is proposed based on the FOCS analysis. The method requires performing data acquisition at two different input polarisations. Based on these measurements, the optimal laser source polarisation can be found. The method was experimentally verified using laboratory set-up and then successfully demonstrated with the FOCS installed at JET.
Open AccessPerformance Enhancement of the Polarimetric Fibre Optical Current Sensor at JET Using Polarisation Optimisation
To achieve optimal operation of the polarimetry-based FOCS, the light polarisation state at the input of the sensing fibre part must be close to a linear one. In the case of a FOCS deployed on a tokamak, the Joint European Torus (JET) in the present work, the long fibre optics link between the laser source and the sensing fibre modifies the polarisation in an unpredictable way, making it unclear which source polarisation state is to be set. A method for performing the necessary polarisation adjustment in a systematic way is proposed based on the FOCS analysis. The method requires performing data acquisition at two different input polarisations. Based on these measurements, the optimal laser source polarisation can be found. The method was experimentally verified using laboratory set-up and then successfully demonstrated with the FOCS installed at JET.
- Open Access
Distributed Poloidal Magnetic Field Measurement in Tokamaks Using Polarization-Sensitive Reflectometric Fiber Optic Sensor
Determination of the poloidal magnetic field distribution in tokamaks is of prime importance for the successful operation of tokamaks. In this paper, we propose a polarization-sensitive reflectometry-based optical fiber sensor for measuring the spatial distribution of the poloidal magnetic field in tokamaks. The measurement method exploits the Rayleigh backscattering and Faraday magneto-optic effect in optical fibers. The former is an intrinsic property of optical fibers and enables distributed polarization measurements, while the latter arises in the presence of a magnetic field parallel to the optical fiber axis and rotates the polarization state of the light. When an optical fiber is looped around a toroidal section of the vacuum vessel, the local polarization rotation of the light is proportional to the local poloidal magnetic field in the tokamak. The proposed method is discussed theoretically and experimentally using the results from JET. The obtained magnetic field measurement shows a good agreement with that of the internal discrete coils. A potential solution to recover the magnetic field data from the noise-affected region of the optical measurement is proposed and is demonstrated through simulations using the JET magnetic field configuration.
Open AccessDistributed Poloidal Magnetic Field Measurement in Tokamaks Using Polarization-Sensitive Reflectometric Fiber Optic Sensor
Determination of the poloidal magnetic field distribution in tokamaks is of prime importance for the successful operation of tokamaks. In this paper, we propose a polarization-sensitive reflectometry-based optical fiber sensor for measuring the spatial distribution of the poloidal magnetic field in tokamaks. The measurement method exploits the Rayleigh backscattering and Faraday magneto-optic effect in optical fibers. The former is an intrinsic property of optical fibers and enables distributed polarization measurements, while the latter arises in the presence of a magnetic field parallel to the optical fiber axis and rotates the polarization state of the light. When an optical fiber is looped around a toroidal section of the vacuum vessel, the local polarization rotation of the light is proportional to the local poloidal magnetic field in the tokamak. The proposed method is discussed theoretically and experimentally using the results from JET. The obtained magnetic field measurement shows a good agreement with that of the internal discrete coils. A potential solution to recover the magnetic field data from the noise-affected region of the optical measurement is proposed and is demonstrated through simulations using the JET magnetic field configuration.
- Open Access
Neutronics Simulations for DEMO Diagnostics
One of the main challenges in the development of a plasma diagnostic and control system for DEMO is the need to cope with unprecedented radiation levels in a tokamak during long operation periods. A list of diagnostics required for plasma control has been developed during the pre-conceptual design phase. Different approaches are proposed for the integration of these diagnostics in DEMO: in equatorial and upper ports, in the divertor cassette, on the inner and outer surfaces of the vacuum vessel and in diagnostic slim cassettes, a modular approach developed for diagnostics requiring access to the plasma from several poloidal positions. According to each integration approach, diagnostics will be exposed to different radiation levels, with a considerable impact on their design. This paper provides a broad overview of the radiation environment that diagnostics in DEMO are expected to face. Using the water-cooled lithium lead blanket configuration as a reference, neutronics simulations were performed for pre-conceptual designs of in-vessel, ex-vessel and equatorial port diagnostics representative of each integration approach. Flux and nuclear load calculations are provided for several sub-systems, along with estimations of radiation streaming to the ex-vessel for alternative design configurations. The results can be used as a reference by diagnostic designers.
Open AccessNeutronics Simulations for DEMO Diagnostics
One of the main challenges in the development of a plasma diagnostic and control system for DEMO is the need to cope with unprecedented radiation levels in a tokamak during long operation periods. A list of diagnostics required for plasma control has been developed during the pre-conceptual design phase. Different approaches are proposed for the integration of these diagnostics in DEMO: in equatorial and upper ports, in the divertor cassette, on the inner and outer surfaces of the vacuum vessel and in diagnostic slim cassettes, a modular approach developed for diagnostics requiring access to the plasma from several poloidal positions. According to each integration approach, diagnostics will be exposed to different radiation levels, with a considerable impact on their design. This paper provides a broad overview of the radiation environment that diagnostics in DEMO are expected to face. Using the water-cooled lithium lead blanket configuration as a reference, neutronics simulations were performed for pre-conceptual designs of in-vessel, ex-vessel and equatorial port diagnostics representative of each integration approach. Flux and nuclear load calculations are provided for several sub-systems, along with estimations of radiation streaming to the ex-vessel for alternative design configurations. The results can be used as a reference by diagnostic designers.
- 4 March 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 192
Recent achievements in R&D on fibre optics current sensor for ITER
- 4 March 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 192
Recent achievements in R&D on fibre optics current sensor for ITER
- Open Access
Assessment of the Structural Vibration Effect on Plasma Current Measurement Using a Fiber Optic Current Sensor in ITER
In this paper, we assess the effect of cryostat bridge vibrations on the plasma current measurement accuracy when using a fiber optic current sensor (FOCS) in ITER. The impact of vibrations on the light polarization state was first experimentally investigated using a miniaturized mock-up which represented a relevant part of the ITER FOCS structure. The set-up was then numerically simulated using the Jones matrix approach. Equivalent vibration matrices obtained from the experiment were used in the simulations to determine the effect of the vibrations on the FOCS accuracy. It is demonstrated that although the vibrations imply some changes in the polarization state, this effect can be strongly reduced when a proper low-birefringent spun optical fiber is used. The ITER requirement regarding the plasma current measurement accuracy can therefore be fulfilled.
Open AccessAssessment of the Structural Vibration Effect on Plasma Current Measurement Using a Fiber Optic Current Sensor in ITER
In this paper, we assess the effect of cryostat bridge vibrations on the plasma current measurement accuracy when using a fiber optic current sensor (FOCS) in ITER. The impact of vibrations on the light polarization state was first experimentally investigated using a miniaturized mock-up which represented a relevant part of the ITER FOCS structure. The set-up was then numerically simulated using the Jones matrix approach. Equivalent vibration matrices obtained from the experiment were used in the simulations to determine the effect of the vibrations on the FOCS accuracy. It is demonstrated that although the vibrations imply some changes in the polarization state, this effect can be strongly reduced when a proper low-birefringent spun optical fiber is used. The ITER requirement regarding the plasma current measurement accuracy can therefore be fulfilled.