Hossein Ali Pakravan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hossein Ali Pakravan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Masoudi
School of Mechanical Engineering, Shiraz University, Shiraz, Iran
3 shared publications Bahar Firoozabadi
Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
3 shared publications- Bahar Firoozabadi
Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
2 shared publications - Farshad Tajeddini
Center of Excellence in Energy Conversion, School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
2 shared publications - Hamed Bazrafshan Drissi
Department of Cardiology, Shiraz University of Medical Sciences, Shiraz, Iran
2 shared publications - Mahmood Yaghoubi
Shiraz University
2 shared publications
Latest Publications
- 28 November 2025
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering
- Vol. 50 (2) , 601-613
Numerical Simulation of Hemodynamics in In-Situ Bilateral Internal Thoracic Artery Grafting
- 28 November 2025
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering
- Vol. 50 (2) , 601-613
Numerical Simulation of Hemodynamics in In-Situ Bilateral Internal Thoracic Artery Grafting
- 13 August 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Dimpled tubes for efficient ice slurry thermo-hydraulics: a numerical investigation on geometrical configurations
- 13 August 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 279
Dimpled tubes for efficient ice slurry thermo-hydraulics: a numerical investigation on geometrical configurations
- 5 March 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 63 (8) , 2393-2406
Comprehensive comparison of different BITA graft configurations: a computational study integrating TTFM and hemodynamic predictors
Bilateral internal thoracic artery (BITA) grafting utilizes both the left (LITA) and right (RITA) internal thoracic arteries simultaneously and is recommended in the literature. However, the optimal configuration for BITA grafting remains uncertain. In this study, three-dimensional numerical simulations of different BITA configurations were conducted to identify the optimal configuration and assess their performance using the fractional flow reserve (FFR), transit time flow meter (TTFM), and hemodynamic parameters. The vessel geometry of a patient who underwent a BITA grafting with a Y-graft configuration was extracted from CT angiography images, and three other configurations (pedicle, LITA as free graft, and RITA as free graft) with different degrees of stenosis were reconstructed. Results showed that, in mild to moderate stenosis (FFR > 0.7), the Y-graft configuration was less favorable for graft quality, as it had higher pulsatility index (PI) and systolic reverse flow (SRF) values, leading to increased competitive flow. However, as stenosis severity increased, these differences decreased, and for severe stenosis, the results were similar for all BITA configurations. Furthermore, the results showed that the Y-graft configuration was less effective in reducing TAWSS compared to other configurations. Oscillatory shear index (OSI) and relative residence time (RRT) did not show significant differences. Graphical Abstract
- 5 March 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 63 (8) , 2393-2406
Comprehensive comparison of different BITA graft configurations: a computational study integrating TTFM and hemodynamic predictors
Bilateral internal thoracic artery (BITA) grafting utilizes both the left (LITA) and right (RITA) internal thoracic arteries simultaneously and is recommended in the literature. However, the optimal configuration for BITA grafting remains uncertain. In this study, three-dimensional numerical simulations of different BITA configurations were conducted to identify the optimal configuration and assess their performance using the fractional flow reserve (FFR), transit time flow meter (TTFM), and hemodynamic parameters. The vessel geometry of a patient who underwent a BITA grafting with a Y-graft configuration was extracted from CT angiography images, and three other configurations (pedicle, LITA as free graft, and RITA as free graft) with different degrees of stenosis were reconstructed. Results showed that, in mild to moderate stenosis (FFR > 0.7), the Y-graft configuration was less favorable for graft quality, as it had higher pulsatility index (PI) and systolic reverse flow (SRF) values, leading to increased competitive flow. However, as stenosis severity increased, these differences decreased, and for severe stenosis, the results were similar for all BITA configurations. Furthermore, the results showed that the Y-graft configuration was less effective in reducing TAWSS compared to other configurations. Oscillatory shear index (OSI) and relative residence time (RRT) did not show significant differences. Graphical Abstract
- 13 November 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 259
Thermal and hydrodynamic characteristics of microencapsulated phase change materials slurry flow in wavy microchannels
- 13 November 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 259
Thermal and hydrodynamic characteristics of microencapsulated phase change materials slurry flow in wavy microchannels
- 1 September 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (9)
Competitive flow of bilateral internal thoracic artery Y-graft: Insights from hemodynamics and transit time flow measurement parameters
Recent studies have demonstrated the superior efficacy of bilateral internal thoracic artery (BITA) grafts compared to other graft methods in treating coronary artery disease. Competitive flow (CF) is a primary factor contributing to graft failure in the long term. For the first time, the CF of the BITA-Y graft has undergone rigorous numerical analysis. Through the application of transit time flow measurement (TTFM) and hemodynamic parameters, this study provides a new perspective on graft performance. Simulation results indicate that average flow, TTFM, and hemodynamic parameters fall within the critical range for stenosis severities below 90%. Specifically, at 80% stenosis, the mean graft flow (MGF) and pulsatility index (PI) of the left internal thoracic artery (LITA) were 0.071 cc/s and 27, respectively, while those of the right internal thoracic artery (RITA) were 0.211 cc/s and 11. With increasing stenosis severity, TTFM parameters remained within the clinical permissible limit (MGF > 0.34 cc/s and PI < 5). At 95% stenosis severity, the MGF and PI for LITA were 0.526 cc/s and 1.2, respectively, while those for RITA were 0.790 cc/s and 0.9. The results indicate the presence of competitive flow within the BITA-Y graft for stenosis severities below 90% area reduction, suggesting a potential risk of graft failure in the long term. Additionally, the results indicated that when there are significant differences in stenosis severity between the two native arteries, the BITA-Y graft is not optimal due to CF, characterized by low MGF and high reverse flow.
- 1 September 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (9)
Competitive flow of bilateral internal thoracic artery Y-graft: Insights from hemodynamics and transit time flow measurement parameters
Recent studies have demonstrated the superior efficacy of bilateral internal thoracic artery (BITA) grafts compared to other graft methods in treating coronary artery disease. Competitive flow (CF) is a primary factor contributing to graft failure in the long term. For the first time, the CF of the BITA-Y graft has undergone rigorous numerical analysis. Through the application of transit time flow measurement (TTFM) and hemodynamic parameters, this study provides a new perspective on graft performance. Simulation results indicate that average flow, TTFM, and hemodynamic parameters fall within the critical range for stenosis severities below 90%. Specifically, at 80% stenosis, the mean graft flow (MGF) and pulsatility index (PI) of the left internal thoracic artery (LITA) were 0.071 cc/s and 27, respectively, while those of the right internal thoracic artery (RITA) were 0.211 cc/s and 11. With increasing stenosis severity, TTFM parameters remained within the clinical permissible limit (MGF > 0.34 cc/s and PI < 5). At 95% stenosis severity, the MGF and PI for LITA were 0.526 cc/s and 1.2, respectively, while those for RITA were 0.790 cc/s and 0.9. The results indicate the presence of competitive flow within the BITA-Y graft for stenosis severities below 90% area reduction, suggesting a potential risk of graft failure in the long term. Additionally, the results indicated that when there are significant differences in stenosis severity between the two native arteries, the BITA-Y graft is not optimal due to CF, characterized by low MGF and high reverse flow.
- 1 December 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 139, 104958
A validated reduced-order dynamic model of nitric oxide regulation in coronary arteries
- 1 December 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 139, 104958
A validated reduced-order dynamic model of nitric oxide regulation in coronary arteries
- 4 July 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (10) , e3382
High precision invasive FFR, low‐cost invasive iFR, or non‐invasive CFR?: optimum assessment of coronary artery stenosis based on the patient‐specific computational models
The objective of this paper is to apply computational fluid dynamic (CFD) as a complementary tool for clinical tests to not only predict the present and future status of left coronary artery stenosis but also to evaluate some clinical hypotheses. In order to assess the present status of the coronary artery stenosis severity, and thereby selecting the most appropriate type of treatment for each patient, fractional flow reserve (FFR), instantaneous wave free‐ratio (iFR), and coronary flow reserve (CFR) are calculated. To examine FFR, iFR, and CFR results, the effect of geometric features of stenoses, including diameter reduction (%), lesion length (LL), and minimum lumen diameter (MLD), is studied on them. It is observed that FFR is a more conservative index than iFR and CFR to assess the severity of coronary stenosis. In addition, it is seen that FFR, iFR, and CFR decrease by increasing LL and decreasing MLD. Therefore, the morphological indices, LL/MLD and LL/MLD̂4, with the calculated conservative cut‐off values equal to 5.5 and 3.6, are considered. Next, some controversial clinical hypotheses about the assessment of the severity of coronary stenosis are evaluated numerically. These include the examination of FFR, iFR, and CFR accuracies, investigating the effect of coronary hyperemia on iFR, as well as the reliability of the hybrid iFR‐FFR decision‐making strategy. The presented numerical model can also be used as a predictive tool to identify the atherosuseptible sites of arteries by calculating the time‐averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT).
- 4 July 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 36 (10) , e3382
High precision invasive FFR, low‐cost invasive iFR, or non‐invasive CFR?: optimum assessment of coronary artery stenosis based on the patient‐specific computational models
The objective of this paper is to apply computational fluid dynamic (CFD) as a complementary tool for clinical tests to not only predict the present and future status of left coronary artery stenosis but also to evaluate some clinical hypotheses. In order to assess the present status of the coronary artery stenosis severity, and thereby selecting the most appropriate type of treatment for each patient, fractional flow reserve (FFR), instantaneous wave free‐ratio (iFR), and coronary flow reserve (CFR) are calculated. To examine FFR, iFR, and CFR results, the effect of geometric features of stenoses, including diameter reduction (%), lesion length (LL), and minimum lumen diameter (MLD), is studied on them. It is observed that FFR is a more conservative index than iFR and CFR to assess the severity of coronary stenosis. In addition, it is seen that FFR, iFR, and CFR decrease by increasing LL and decreasing MLD. Therefore, the morphological indices, LL/MLD and LL/MLD̂4, with the calculated conservative cut‐off values equal to 5.5 and 3.6, are considered. Next, some controversial clinical hypotheses about the assessment of the severity of coronary stenosis are evaluated numerically. These include the examination of FFR, iFR, and CFR accuracies, investigating the effect of coronary hyperemia on iFR, as well as the reliability of the hybrid iFR‐FFR decision‐making strategy. The presented numerical model can also be used as a predictive tool to identify the atherosuseptible sites of arteries by calculating the time‐averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT).