Adel Deriszadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adel Deriszadeh has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Ali Abedi
2 shared publicationsEhsan Adib
Department of Electrical and Computer Engineering Isfahan University of Technology Isfahan Iran
2 shared publications- Hosein Farzanehfard
Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, Iran
2 shared publications - Martin Ćalasan
Department of Electrical Engineering, University of Montenegro, Podgorica, Montenegro
2 shared publications - Mojtaba Khalilian
Politecnico di Torino, Department of Energy, Italy
2 shared publications Orkun Karabasoglu
Department of Industrial Engineering Yasar University Bornova Izmir Turkey
2 shared publications
Latest Publications
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-6
Gate Driver Design for Cryogenically Cooled Power Electronic Converters
This article explores the design and experimental validation of an isolated half-bridge DC-DC converter customized for cryogenic environments, addressing the challenges posed by extreme low temperatures. The key contribution lies in the adoption of the isolated half-bridge topology which ensures exceptional output voltage stability with a simplified structure. By leveraging this innovative design, a rigorous design process for the selection of critical components is employed to ensure the stable performance and reliability at cryogenic environment. The performance of the designed isolated DC-DC converter and practical challenges are investigated experimentally at a cryogenic temperature. The results contribute valuable insights to the converter design in extreme temperature environments, promising advancements in the field of cryogenic power electronics.
- 5 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (3) , 1-6
Gate Driver Design for Cryogenically Cooled Power Electronic Converters
This article explores the design and experimental validation of an isolated half-bridge DC-DC converter customized for cryogenic environments, addressing the challenges posed by extreme low temperatures. The key contribution lies in the adoption of the isolated half-bridge topology which ensures exceptional output voltage stability with a simplified structure. By leveraging this innovative design, a rigorous design process for the selection of critical components is employed to ensure the stable performance and reliability at cryogenic environment. The performance of the designed isolated DC-DC converter and practical challenges are investigated experimentally at a cryogenic temperature. The results contribute valuable insights to the converter design in extreme temperature environments, promising advancements in the field of cryogenic power electronics.
- 24 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3524-3533
A Novel Field Current Estimation Method for Brushless Wound-Field Synchronous Machine
Compared with other electric machines, wound-field synchronous machines have the advantage of having three control variables (stator d- and q-axis currents and rotor current). Determining the optimum combination of field and armature currents is necessary for ensuring the high-performance control of the wound-field synchronous machine. Two methods are usually employed to supply the field winding of the wound-field synchronous machine. The first one uses brushes and slip rings, while the second one uses a brushless excitation system. Concerning the wound-field synchronous machine with a brushless excitation system, a DC field current is provided by a rotating diode bridge rectifier fed by an exciter machine. Therefore, direct measurement of the field current is not possible. As a solution, field current needs to be accurately estimated. Previously, field current estimation methods proposed in the literature have been based on modelling the brushless exciter machine and the rotating rectifier. Using the brushless exciter machine model, these methods estimate electric quantities of the exciter rotor (currents and voltages), then through the rotating rectifier model, the rectified field current is estimated. Accordingly, any inaccuracy in the models leads to estimation errors. The effectiveness of the techniques relying on the brushless excitation system model is not clearly justified, especially because the nonlinearity of the brushless system has been intensified by the existence of the rotating uncontrolled diode bridge rectifier. This paper proposes an accurate online field current estimation method for wound-field synchronous machines without the need to estimate exciter rotor voltages or currents nor to use a rotating rectifier model. The accuracy and effectiveness of the proposed field current estimation method are demonstrated by experimental validation tests.
- 24 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (3) , 3524-3533
A Novel Field Current Estimation Method for Brushless Wound-Field Synchronous Machine
Compared with other electric machines, wound-field synchronous machines have the advantage of having three control variables (stator d- and q-axis currents and rotor current). Determining the optimum combination of field and armature currents is necessary for ensuring the high-performance control of the wound-field synchronous machine. Two methods are usually employed to supply the field winding of the wound-field synchronous machine. The first one uses brushes and slip rings, while the second one uses a brushless excitation system. Concerning the wound-field synchronous machine with a brushless excitation system, a DC field current is provided by a rotating diode bridge rectifier fed by an exciter machine. Therefore, direct measurement of the field current is not possible. As a solution, field current needs to be accurately estimated. Previously, field current estimation methods proposed in the literature have been based on modelling the brushless exciter machine and the rotating rectifier. Using the brushless exciter machine model, these methods estimate electric quantities of the exciter rotor (currents and voltages), then through the rotating rectifier model, the rectified field current is estimated. Accordingly, any inaccuracy in the models leads to estimation errors. The effectiveness of the techniques relying on the brushless excitation system model is not clearly justified, especially because the nonlinearity of the brushless system has been intensified by the existence of the rotating uncontrolled diode bridge rectifier. This paper proposes an accurate online field current estimation method for wound-field synchronous machines without the need to estimate exciter rotor voltages or currents nor to use a rotating rectifier model. The accuracy and effectiveness of the proposed field current estimation method are demonstrated by experimental validation tests.
- Open Access
- 10 January 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (3) , 584-589
A dynamic functional model of diode bridge rectifier for unbalanced input voltage conditions
Diode bridge rectifiers are employed in many industrial applications wherein, under practical operating conditions, input voltages can be occasionally or inherently unbalanced. Using the switching function method, this paper proposes a new accurate functional model of the diode bridge rectifier capable of dealing with unbalanced input voltage conditions. To take all degrees of unbalanced conditions into account, this paper introduces uneven commutation intervals phenomenon between diodes occurring under unbalanced voltage conditions and proposes dynamically updating switching functions.
- 10 January 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (3) , 584-589
Open AccessA dynamic functional model of diode bridge rectifier for unbalanced input voltage conditions
Diode bridge rectifiers are employed in many industrial applications wherein, under practical operating conditions, input voltages can be occasionally or inherently unbalanced. Using the switching function method, this paper proposes a new accurate functional model of the diode bridge rectifier capable of dealing with unbalanced input voltage conditions. To take all degrees of unbalanced conditions into account, this paper introduces uneven commutation intervals phenomenon between diodes occurring under unbalanced voltage conditions and proposes dynamically updating switching functions.
- 6 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Notes on parameter estimation for single-phase transformer
TThis paper investigates the inaccuracies of identifying parameters for a single-phase transformer. In addition, in this paper, two new transformer parameter estimation algorithms based on recently developed optimization techniques, as well as an objective function, are proposed for the transformer parameter estimation to improve the estimation process and prevent inaccuracies and parameters mismatch with real parameters of the transformer. The proposed algorithms utilize Manta Ray Foraging optimization and Chaotic Manta Ray Foraging optimization methods for the estimation of transformer parameters. Unlike the previously proposed methods in the literature, the proposed objective function in this paper includes no-load losses in the estimation process. For the matter of comparison, the estimated parameters obtained by using proposed optimization techniques and objective function are compared with the corresponding values obtained using the classical test procedure recommended by IEEE, as well as with the corresponding values obtained using the previously introduced methods in the literature. The usage of the proposed objective function guarantees the representation of the real copper and no-load losses in the estimated transformer parameters and ensures that the estimated transformer output characteristics are in very good agreement with the experimentally obtained curves. To prove the effectiveness of the proposed parameter estimation algorithms, experimental parameters identification tests are implemented and the experimentally identified transformer parameters are compared with the estimated parameters and their correlation is studied.
- 6 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1
Notes on parameter estimation for single-phase transformer
TThis paper investigates the inaccuracies of identifying parameters for a single-phase transformer. In addition, in this paper, two new transformer parameter estimation algorithms based on recently developed optimization techniques, as well as an objective function, are proposed for the transformer parameter estimation to improve the estimation process and prevent inaccuracies and parameters mismatch with real parameters of the transformer. The proposed algorithms utilize Manta Ray Foraging optimization and Chaotic Manta Ray Foraging optimization methods for the estimation of transformer parameters. Unlike the previously proposed methods in the literature, the proposed objective function in this paper includes no-load losses in the estimation process. For the matter of comparison, the estimated parameters obtained by using proposed optimization techniques and objective function are compared with the corresponding values obtained using the classical test procedure recommended by IEEE, as well as with the corresponding values obtained using the previously introduced methods in the literature. The usage of the proposed objective function guarantees the representation of the real copper and no-load losses in the estimated transformer parameters and ensures that the estimated transformer output characteristics are in very good agreement with the experimentally obtained curves. To prove the effectiveness of the proposed parameter estimation algorithms, experimental parameters identification tests are implemented and the experimentally identified transformer parameters are compared with the estimated parameters and their correlation is studied.
- Open Access
- 15 August 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (11) , 2873-2883
Excitation procedure for brushless wound‐rotor synchronous starter generator with seamless transitions
An analytical model of excitation system of brushless wound‐rotor synchronous starter generator for aircraft applications is developed and presented in this study. During engine start‐up process, the starter generator operates as a motor to start the aircraft turbine and to assist it up to the self‐sustaining speed. On the basis of rotation speed of the starter generator in the engine start‐up process, there are three excitation modes for the exciter and two transient modes for the field current of the main generator (MG). In this study, for each excitation mode, the relationship between the excitation current (field current of the exciter) and the field current of MG is investigated by taking into account the influence of power electronic parts. This study also proposes a control method for the generator field current in all excitation modes which can detect optimum operating points for transition between excitation modes. Furthermore, a seamless transient control strategy is proposed for the transient modes of the generator field current. Simulation and experimental results are provided to demonstrate the feasibility of the proposed solution.
- 15 August 2019
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 12 (11) , 2873-2883
Open AccessExcitation procedure for brushless wound‐rotor synchronous starter generator with seamless transitions
An analytical model of excitation system of brushless wound‐rotor synchronous starter generator for aircraft applications is developed and presented in this study. During engine start‐up process, the starter generator operates as a motor to start the aircraft turbine and to assist it up to the self‐sustaining speed. On the basis of rotation speed of the starter generator in the engine start‐up process, there are three excitation modes for the exciter and two transient modes for the field current of the main generator (MG). In this study, for each excitation mode, the relationship between the excitation current (field current of the exciter) and the field current of MG is investigated by taking into account the influence of power electronic parts. This study also proposes a control method for the generator field current in all excitation modes which can detect optimum operating points for transition between excitation modes. Furthermore, a seamless transient control strategy is proposed for the transient modes of the generator field current. Simulation and experimental results are provided to demonstrate the feasibility of the proposed solution.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 478-482
Synchronous undermodulation control modes of system with three PWM converters
This paper is focused on the operation analysis of transformer-based ac drive system with three modulated converters connected specifically to windings of power transformer. It provides multilevel voltage to induction machine by means of three sets of converter-side windings of power transformer. A special switching scheme has been disseminated for adjustment of converters, insuring synchronization of its output voltages and symmetry of voltage waveforms. The total harmonics distortion factor and weighted total harmonic distortion factor have been determined and compared for the basic voltages of this installation. The system performance with three techniques of continuous and discontinuous pulsewidth modulation (PWM) has been evaluated with accent on comparative study of voltage distortion on the converter-side windings of the transformer.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 478-482
Synchronous undermodulation control modes of system with three PWM converters
This paper is focused on the operation analysis of transformer-based ac drive system with three modulated converters connected specifically to windings of power transformer. It provides multilevel voltage to induction machine by means of three sets of converter-side windings of power transformer. A special switching scheme has been disseminated for adjustment of converters, insuring synchronization of its output voltages and symmetry of voltage waveforms. The total harmonics distortion factor and weighted total harmonic distortion factor have been determined and compared for the basic voltages of this installation. The system performance with three techniques of continuous and discontinuous pulsewidth modulation (PWM) has been evaluated with accent on comparative study of voltage distortion on the converter-side windings of the transformer.
- Open Access
- 1 July 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (7) , 1119-1127
Switched reluctance motor drive converter operating in continuous conduction mode with high demagnetisation voltage
A new switched reluctance motor (SRM) drive converter requiring only one switch per phase with the capability of providing high demagnetisation voltage is presented. To increase the output torque of the SRM drive system, the phase excitation area must be increased; however, during the demagnetisation interval, this would cause the phase current to extend into the negative torque generation area. To eliminate this problem, the proposed converter provides high demagnetisation voltage in order to perform the phase current commutation faster. The proposed converter inherently operates in continuous conduction mode (CCM); thus, innovative aspect of the proposed converter is exploiting the advantages of operating with high demagnetisation voltage in CCM. The converter operating modes are analysed and the effectiveness of the proposed converter on improvement of SRM drive torque per ampere capability is demonstrated by simulation and experimental results.
- 1 July 2015
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 8 (7) , 1119-1127
Open AccessSwitched reluctance motor drive converter operating in continuous conduction mode with high demagnetisation voltage
A new switched reluctance motor (SRM) drive converter requiring only one switch per phase with the capability of providing high demagnetisation voltage is presented. To increase the output torque of the SRM drive system, the phase excitation area must be increased; however, during the demagnetisation interval, this would cause the phase current to extend into the negative torque generation area. To eliminate this problem, the proposed converter provides high demagnetisation voltage in order to perform the phase current commutation faster. The proposed converter inherently operates in continuous conduction mode (CCM); thus, innovative aspect of the proposed converter is exploiting the advantages of operating with high demagnetisation voltage in CCM. The converter operating modes are analysed and the effectiveness of the proposed converter on improvement of SRM drive torque per ampere capability is demonstrated by simulation and experimental results.
- Open Access
- 1 January 2012
- Published by Elsevier in Energy Procedia
- Vol. 14, 1998-2004
Position Control of Hybrid Stepper Motor Using Brain Emotional Controller
- 1 January 2012
- Published by Elsevier in Energy Procedia
- Vol. 14, 1998-2004
Open AccessPosition Control of Hybrid Stepper Motor Using Brain Emotional Controller
- Open Access
- 1 January 2012
- Published by Elsevier in Energy Procedia
- Vol. 14, 1992-1997
Sensorless Direct Torque Control of Hybrid Stepper Motor Based on MRAS
- 1 January 2012
- Published by Elsevier in Energy Procedia
- Vol. 14, 1992-1997
Open AccessSensorless Direct Torque Control of Hybrid Stepper Motor Based on MRAS
- 1 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 473-477
New converter for switched reluctance motor drive with wide speed range operation
This paper offers a new converter for switched reluctance motor (SRM) drive which uses one switch in each phase. One switch for each phase is the least number of switches among the converters used in the switch reluctance motor drive. Also, the proposed converter enjoy from an important characteristic which makes it suitable for high speed drive applications. This is due to the fast phase current commutation capability of this converter. Therefore, the generation of negative torque and consequently, large generated torque ripples in SRM drive are resolved. SRM drive simulation using the proposed converter is presented and the results are compared with the asymmetric converter which is usually used in SRM drives.
- 1 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 473-477
New converter for switched reluctance motor drive with wide speed range operation
This paper offers a new converter for switched reluctance motor (SRM) drive which uses one switch in each phase. One switch for each phase is the least number of switches among the converters used in the switch reluctance motor drive. Also, the proposed converter enjoy from an important characteristic which makes it suitable for high speed drive applications. This is due to the fast phase current commutation capability of this converter. Therefore, the generation of negative torque and consequently, large generated torque ripples in SRM drive are resolved. SRM drive simulation using the proposed converter is presented and the results are compared with the asymmetric converter which is usually used in SRM drives.