Chan Bun Seng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chan Bun Seng has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Ismail Saad
Universiti Malaysia Sabah
19 shared publications- Bablu Kumar Ghosh
Faculty of Engineering, Universiti Malaysia Sabah, 88400, Kota Kinabalu Sabah, Malaysia
11 shared publications N. Bolong
9 shared publicationsNurmin Bolong
Universiti Malaysia Sabah
8 shared publicationsH. Mohd. Zuhir
Nano Engineering & Material (NEMs) Research Group, Faculty of Engineering, Universiti Malaysia Sabah, 88999, Kota Kinabalu, Sabah, Malaysia
6 shared publications- Khairul Anuar Mohamad
Department of Electrical Engineering Faculty of Electrical and Electronic Engineering Universiti Tun Hussein Onn Malaysia Parit Raja Malaysia
6 shared publications
Latest Publications
- Open Access
- 1 June 2018
- Published by Universitas Ahmad Dahlan in TELKOMNIKA (Telecommunication Computing Electronics and Control)
- Vol. 16 (3) , 955
Stereo Vision Human Motion Detection and Tracking in Uncontrolled Environment
- 1 June 2018
- Published by Universitas Ahmad Dahlan in TELKOMNIKA (Telecommunication Computing Electronics and Control)
- Vol. 16 (3) , 955
Open AccessStereo Vision Human Motion Detection and Tracking in Uncontrolled Environment
- 1 November 2017
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 23 (11) , 11247-11251
Enhanced Reliability of Vertical Strained Impact Ionization MOSFET Incorporating Dielectric Pocket for Ultra-Sensitive Biosensor Applications
Fast switching with an enhanced reliability device structure of Vertical Strained Impact Ionization MOSFET incorporating Dielectric Pocket (VESIMOS-DP) has been successfully design, simulated and analyzed in this paper. Ultra-low power with low subthreshold swing (S) and high breakdown voltage are imperative for ultra-sensitive biosensors. Impact ionization MOSFET (IMOS) is predicted to be capable of S as low as 20 mV/dec, which is much lower than Conventional MOSFET (CMOS). There are significant drop in subthreshold slope (S) while threshold voltage is increase as the body doping concentration increases. S value for DP place at source side is higher (S 24.4 mV/decade) as compared at the drain side (S 18.9 mV/decade) intrinsic region. The vicinity of DP near the drain region reduces charge sharing effects associated with the source and thus improves impact ionization rate. The introduction of a Dielectric Pocket (DP) is believed to be able to minimize the PBT effect while improving the reliability of the device by attaining higher breakdown voltage. Consequently, with the reduced of alloy scattering, the electron mobility has been improved by 22%. In many aspects, it is revealed that the incorporation of DP enhanced the reliability of VESIMOS for future development of nanoelectronic devices.
- 1 November 2017
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 23 (11) , 11247-11251
Enhanced Reliability of Vertical Strained Impact Ionization MOSFET Incorporating Dielectric Pocket for Ultra-Sensitive Biosensor Applications
Fast switching with an enhanced reliability device structure of Vertical Strained Impact Ionization MOSFET incorporating Dielectric Pocket (VESIMOS-DP) has been successfully design, simulated and analyzed in this paper. Ultra-low power with low subthreshold swing (S) and high breakdown voltage are imperative for ultra-sensitive biosensors. Impact ionization MOSFET (IMOS) is predicted to be capable of S as low as 20 mV/dec, which is much lower than Conventional MOSFET (CMOS). There are significant drop in subthreshold slope (S) while threshold voltage is increase as the body doping concentration increases. S value for DP place at source side is higher (S 24.4 mV/decade) as compared at the drain side (S 18.9 mV/decade) intrinsic region. The vicinity of DP near the drain region reduces charge sharing effects associated with the source and thus improves impact ionization rate. The introduction of a Dielectric Pocket (DP) is believed to be able to minimize the PBT effect while improving the reliability of the device by attaining higher breakdown voltage. Consequently, with the reduced of alloy scattering, the electron mobility has been improved by 22%. In many aspects, it is revealed that the incorporation of DP enhanced the reliability of VESIMOS for future development of nanoelectronic devices.
- 1 November 2017
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 23 (11) , 11242-11246
Vertical Strained Impact Ionization MOSFET (VESIMOS) Technology Approach for Based Biosensor Applications Using Its Behavioral Model
This paper gives an overview about uniqueness characteristics of Vertical Strained Impact Ionization MOSFET (VESIMOS) technology act as bio-sensing devices. There are three proposed devices used VESIMOS technology which are Single Channel VESIMOS (SC-VESIMOS), Dual Channel (DC-VESIMOS),VESIMOS Incorporating Dielectric Pocket (VESIMOS-DP) are probably can become feasible candidates as biosensor devices. The selected devices from three structures was further analyzed for its behavioral model. The extracted parameter from the device simulations was used to design the circuitrymodel to represent the characteristic and behavior of the selected devices in circuit implementation. The best characteristic of the device shown by DC-VESIMOS and selected for further analysis. The behavioral model or equivalent circuit model of DC-VESIMOS used PSPICE circuit simulator. Mainprerequisite of biosensor device are high sensitivity, faster response, and high reliability which represented by the VESIMOS structures. Low subthreshold swings present the sensitivity of the devices shown by DC-VESIMOS are 11.48 mV/dec and 10.53 mV/dec from TCAD and PSPICE results respectively.
- 1 November 2017
- Published by American Scientific Publishers in Advanced Science Letters
- Vol. 23 (11) , 11242-11246
Vertical Strained Impact Ionization MOSFET (VESIMOS) Technology Approach for Based Biosensor Applications Using Its Behavioral Model
This paper gives an overview about uniqueness characteristics of Vertical Strained Impact Ionization MOSFET (VESIMOS) technology act as bio-sensing devices. There are three proposed devices used VESIMOS technology which are Single Channel VESIMOS (SC-VESIMOS), Dual Channel (DC-VESIMOS),VESIMOS Incorporating Dielectric Pocket (VESIMOS-DP) are probably can become feasible candidates as biosensor devices. The selected devices from three structures was further analyzed for its behavioral model. The extracted parameter from the device simulations was used to design the circuitrymodel to represent the characteristic and behavior of the selected devices in circuit implementation. The best characteristic of the device shown by DC-VESIMOS and selected for further analysis. The behavioral model or equivalent circuit model of DC-VESIMOS used PSPICE circuit simulator. Mainprerequisite of biosensor device are high sensitivity, faster response, and high reliability which represented by the VESIMOS structures. Low subthreshold swings present the sensitivity of the devices shown by DC-VESIMOS are 11.48 mV/dec and 10.53 mV/dec from TCAD and PSPICE results respectively.
- 24 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 105-110
Electromyogram (EMG) Signal Processing Analysis for Clinical Rehabilitation Application
Analysis of electromyogram (EMG) signal processing and its application to identify human muscle strength of rehabilitation purpose has been successfully carried out in this paper. Single channel EMG signal was obtained from human muscle using non-invasive electrodes and further process by signal acquisition circuit to get a suitable signal to be process. In the first part of signal acquisition, the amplification circuit for the small EMG signal has been design successfully. After amplification stage EMG signal was digitized through analogue and digital converter (ADC) then further process in microcontroller (ATmega328) for getting accurate EMG signal. Finally, the processed EMG signal was classified into 6 different levels in order to display the muscle strength level of the user. This EMG device can be used to help the weak person or an elderly to identity their strength level of muscle for clinical rehabilitation purpose.
- 24 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 105-110
Electromyogram (EMG) Signal Processing Analysis for Clinical Rehabilitation Application
Analysis of electromyogram (EMG) signal processing and its application to identify human muscle strength of rehabilitation purpose has been successfully carried out in this paper. Single channel EMG signal was obtained from human muscle using non-invasive electrodes and further process by signal acquisition circuit to get a suitable signal to be process. In the first part of signal acquisition, the amplification circuit for the small EMG signal has been design successfully. After amplification stage EMG signal was digitized through analogue and digital converter (ADC) then further process in microcontroller (ATmega328) for getting accurate EMG signal. Finally, the processed EMG signal was classified into 6 different levels in order to display the muscle strength level of the user. This EMG device can be used to help the weak person or an elderly to identity their strength level of muscle for clinical rehabilitation purpose.
- 22 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 93-96
Enhancing equivalent circuit model of Dual Channel Vertical Strained Impact Ionization MOSFET (DC-VESIMOS) for biosensor applications
Dual Channel Vertical Strained Impact Ionization MOSFET (DC-VESIMOS) device shows superb performance with lower subthreshold slope (S) value of 11.48mV/dec and high range of ON and OFF current of 1013 obtained which indicates fast switching behavior and low leakage current respectively by using Silvaco's TCAD. Besides that, high breakdown voltage, VB of 2.45V is obtained which results in high reliability where the device become a promising candidates as a biosensor applications device. DC-VESIMOS demonstrated S value of 10.53mV/dec with supply voltage of VDS=1.75V in circuitry level. A considerable high breakdown voltage (VB=2.6V) and high ratio of ION/IOFF indicates low leakage currents and good reliability. The input of K parameter determines device behavior and the best value selected is when K=5 when compared with the published experimental works. Increase in body doping concentration will decrease the ON voltage of the device. In many aspects, DC-VESIMOS performance revealed that it was a best candidate to become one of the low power and high performance based biosensor applications device in the future.
- 22 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 93-96
Enhancing equivalent circuit model of Dual Channel Vertical Strained Impact Ionization MOSFET (DC-VESIMOS) for biosensor applications
Dual Channel Vertical Strained Impact Ionization MOSFET (DC-VESIMOS) device shows superb performance with lower subthreshold slope (S) value of 11.48mV/dec and high range of ON and OFF current of 1013 obtained which indicates fast switching behavior and low leakage current respectively by using Silvaco's TCAD. Besides that, high breakdown voltage, VB of 2.45V is obtained which results in high reliability where the device become a promising candidates as a biosensor applications device. DC-VESIMOS demonstrated S value of 10.53mV/dec with supply voltage of VDS=1.75V in circuitry level. A considerable high breakdown voltage (VB=2.6V) and high ratio of ION/IOFF indicates low leakage currents and good reliability. The input of K parameter determines device behavior and the best value selected is when K=5 when compared with the published experimental works. Increase in body doping concentration will decrease the ON voltage of the device. In many aspects, DC-VESIMOS performance revealed that it was a best candidate to become one of the low power and high performance based biosensor applications device in the future.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Physics-based modelling of vertical strained impact ionization MOSFET (VESIMOS)
CMOS device scaling faces several fundamental limits as it scaled beyond the sub-30nm regime. Non-scalability of the subthreshold slope (S) and adverse short channel effects degrading the current drivability and electron mobility of a MOSFET. An innovative device structure with appropriate device physics understanding is vitally needed for scaling the silicon MOSFET into nanometer regime. Underlying this problem is the subthreshold slope concept, which is a measure of switching abruptness in transistor. S is fundamentally limited at 60mV/decade by the drift-diffusion based transport in current CMOS technology. Impact ionization MOSFET (IMOS) that works on the principle of avalanche breakdown mechanism has become promising candidate to overcome this S value constraint. In this paper, we report for the first time an analytical modelling of vertical strained Impact Ionization MOSFET (VESIMOS). We derive the equations and their range of validity and compare the characteristic with TCAD simulations to give truthful interpretation and profound effects in evaluating the device operation for circuit application.
- 1 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Physics-based modelling of vertical strained impact ionization MOSFET (VESIMOS)
CMOS device scaling faces several fundamental limits as it scaled beyond the sub-30nm regime. Non-scalability of the subthreshold slope (S) and adverse short channel effects degrading the current drivability and electron mobility of a MOSFET. An innovative device structure with appropriate device physics understanding is vitally needed for scaling the silicon MOSFET into nanometer regime. Underlying this problem is the subthreshold slope concept, which is a measure of switching abruptness in transistor. S is fundamentally limited at 60mV/decade by the drift-diffusion based transport in current CMOS technology. Impact ionization MOSFET (IMOS) that works on the principle of avalanche breakdown mechanism has become promising candidate to overcome this S value constraint. In this paper, we report for the first time an analytical modelling of vertical strained Impact Ionization MOSFET (VESIMOS). We derive the equations and their range of validity and compare the characteristic with TCAD simulations to give truthful interpretation and profound effects in evaluating the device operation for circuit application.