Philipp Schonle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Philipp Schonle has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Qiuting Huang
Department of Information Technology and Electrical Engineering (D-ITET), ETH Zurich, 8092 Zurich, Switzerland
10 shared publicationsSchekeb Fateh
Integrated System Laboratory, ETH Zurich, 8092 Zürich, Switzerland
8 shared publications- Luca Benini
University of Bologna, Bologna, Italy
6 shared publications Thomas Burger
Integrated System Laboratory, ETH Zurich, 8092 Zürich, Switzerland
4 shared publicationsGiovanni Rovere
Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich, Switzerland
3 shared publications- Thomas Burger
ETH Zurich
3 shared publications
Latest Publications
- 12 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (4) , 1254-1264
A Power-Efficient Fractional-N DPLL With Phase Error Quantized in Fully Differential-Voltage Domain
This article presents a power-efficient low-jitter fractional-N digital phase-locked loop (DPLL) that resolves phase error (PE) in the fully differential voltage (FDV) domain. Compared with adopting a traditional time-to-digital converter (TDC), which relies on gate delay in the time domain, power-efficient quantization of PE by the proposed conversion scheme in the FDV domain can be accomplished with a higher power-supply/common-mode rejection ratio (PSRR/CMRR), lower process, voltage, and temperature (PVT) sensitivity, finer resolution, and better linearity. The implemented DPLL covers the fractional-N operation by a 10-bit differential current digital-to-analog converter (DAC) with a resistive load to represent the fractional phase/time. A differential dv/dt ramp is employed to linearly transfer the preset initial voltage into a small phase/voltage error, which is digitized by a narrow-range fine-resolution 7-bit self-timed successive-approximation-register analog-to-digital converter (SAR-ADC). The prototype DPLL, implemented in 130-nm CMOS, achieves 101-fs rms jitter, integrated from 10 kHz to 40 MHz, in the fractional-N mode with sub-12-bit fractional-frequency-control words, using an 80-MHz reference clock (REF), consuming 9.2 mW. This corresponds to a figure of merit (FoM) of -250.3 dB. The measured worst case fractional spur level is -56 dBc.
- 12 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (4) , 1254-1264
A Power-Efficient Fractional-N DPLL With Phase Error Quantized in Fully Differential-Voltage Domain
This article presents a power-efficient low-jitter fractional-N digital phase-locked loop (DPLL) that resolves phase error (PE) in the fully differential voltage (FDV) domain. Compared with adopting a traditional time-to-digital converter (TDC), which relies on gate delay in the time domain, power-efficient quantization of PE by the proposed conversion scheme in the FDV domain can be accomplished with a higher power-supply/common-mode rejection ratio (PSRR/CMRR), lower process, voltage, and temperature (PVT) sensitivity, finer resolution, and better linearity. The implemented DPLL covers the fractional-N operation by a 10-bit differential current digital-to-analog converter (DAC) with a resistive load to represent the fractional phase/time. A differential dv/dt ramp is employed to linearly transfer the preset initial voltage into a small phase/voltage error, which is digitized by a narrow-range fine-resolution 7-bit self-timed successive-approximation-register analog-to-digital converter (SAR-ADC). The prototype DPLL, implemented in 130-nm CMOS, achieves 101-fs rms jitter, integrated from 10 kHz to 40 MHz, in the fractional-N mode with sub-12-bit fractional-frequency-control words, using an 80-MHz reference clock (REF), consuming 9.2 mW. This corresponds to a figure of merit (FoM) of -250.3 dB. The measured worst case fractional spur level is -56 dBc.
- 4 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (7) , 2076-2087
A Multi-Sensor and Parallel Processing SoC for Miniaturized Medical Instrumentation
We report VivoSoC, a system-on-chip realized in 130-nm CMOS for miniaturized medical instrumentation as used in mobile health devices or implantable telemetry systems for animal experiments. It features six neural stimulation channels and acquisition circuits for 9× electrode-based recordings, 4-channel/32-LED photoplethysmography (PPG), bioimpedance, and temperature. A 34-μW/MHz quad-core processing unit with sophisticated data, power, and clock management techniques enables on-chip feature extraction, which can dramatically reduce transmission or storage data rates in a system-crucial for overall power consumption and exemplarily demonstrated on preliminary work on implantable PPG-based vital signs monitoring.
- 4 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 53 (7) , 2076-2087
A Multi-Sensor and Parallel Processing SoC for Miniaturized Medical Instrumentation
We report VivoSoC, a system-on-chip realized in 130-nm CMOS for miniaturized medical instrumentation as used in mobile health devices or implantable telemetry systems for animal experiments. It features six neural stimulation channels and acquisition circuits for 9× electrode-based recordings, 4-channel/32-LED photoplethysmography (PPG), bioimpedance, and temperature. A 34-μW/MHz quad-core processing unit with sophisticated data, power, and clock management techniques enables on-chip feature extraction, which can dramatically reduce transmission or storage data rates in a system-crucial for overall power consumption and exemplarily demonstrated on preliminary work on implantable PPG-based vital signs monitoring.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 139-144
A sub-10mW real-time implementation for EMG hand gesture recognition based on a multi-core biomedical SoC
Real-time biosignal classification in power-constrained embedded applications is a key step in designing portable e-health devices requiring hardware integration along with concurrent signal processing. This paper presents an application based on a novel biomedical System-On-Chip (SoC) for signal acquisition and processing combining a homogeneous multi-core cluster with a versatile bio-potential front-end. The presented implementation acquires raw EMG signals from 3 passive gel-electrodes and classifies 3 hand gestures using a Support Vector Machine (SVM) pattern recognition algorithm. Performance matches state-of-the-art high-end systems both in terms of recognition accuracy (> 85%) and of real-time execution (gesture recognition time ≪300 ms). The power consumption of the employed biomedical SoC is below 10mW, outperforming implementations on commercial MCUs by a factor of 10, ensuring a battery life of up to 160 hours with a common Li-ion 1600 mAh battery.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 139-144
A sub-10mW real-time implementation for EMG hand gesture recognition based on a multi-core biomedical SoC
Real-time biosignal classification in power-constrained embedded applications is a key step in designing portable e-health devices requiring hardware integration along with concurrent signal processing. This paper presents an application based on a novel biomedical System-On-Chip (SoC) for signal acquisition and processing combining a homogeneous multi-core cluster with a versatile bio-potential front-end. The presented implementation acquires raw EMG signals from 3 passive gel-electrodes and classifies 3 hand gestures using a Support Vector Machine (SVM) pattern recognition algorithm. Performance matches state-of-the-art high-end systems both in terms of recognition accuracy (> 85%) and of real-time execution (gesture recognition time ≪300 ms). The power consumption of the employed biomedical SoC is below 10mW, outperforming implementations on commercial MCUs by a factor of 10, ensuring a battery life of up to 160 hours with a common Li-ion 1600 mAh battery.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A wide tuning-range ADFLL for mW-SoCs with dithering-enhanced accuracy in 65 nm CMOS
We present an integer-N all-digital frequency-locked loop (ADFLL) suitable for dynamic voltage and frequency scaling in system-on-chips targeting mW-consumption. The proposed ADFLL operates with a 32 kHz clock reference, and offers a large clock multiplication factor of 32786, resulting in a wide tuning-range from 19 kHz to 1.048 GHz at 1.2 V and to 250 MHz at 0.8 V,. It incorporates a jitter reduction technique enabling the generation of accurate low-rate clocks in ADFLLs, combining clock division and dithering based on a 1st-order digital ΣΔ-modulator. The measured clock division factor dependent reduction of the peak cycle-to-cycle (C2C) jitter was between 40% and 70% at a 200 MHz DCO clock. The lowest peak C2C jitter of 0.14% was measured at a 3.15MHz output clock derived from a 800 MHz DCO clock. A prototype in UMC 65 nm CMOS occupies 0.013 mm 2 of area, and at 100 MHz consumes 605 μW (scaling with 3 μW/MHz) at 1.2 V, and 205 μW (scaling with 1.2 μW/MHz) at 0.8 V.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A wide tuning-range ADFLL for mW-SoCs with dithering-enhanced accuracy in 65 nm CMOS
We present an integer-N all-digital frequency-locked loop (ADFLL) suitable for dynamic voltage and frequency scaling in system-on-chips targeting mW-consumption. The proposed ADFLL operates with a 32 kHz clock reference, and offers a large clock multiplication factor of 32786, resulting in a wide tuning-range from 19 kHz to 1.048 GHz at 1.2 V and to 250 MHz at 0.8 V,. It incorporates a jitter reduction technique enabling the generation of accurate low-rate clocks in ADFLLs, combining clock division and dithering based on a 1st-order digital ΣΔ-modulator. The measured clock division factor dependent reduction of the peak cycle-to-cycle (C2C) jitter was between 40% and 70% at a 200 MHz DCO clock. The lowest peak C2C jitter of 0.14% was measured at a 3.15MHz output clock derived from a 800 MHz DCO clock. A prototype in UMC 65 nm CMOS occupies 0.013 mm 2 of area, and at 100 MHz consumes 605 μW (scaling with 3 μW/MHz) at 1.2 V, and 205 μW (scaling with 1.2 μW/MHz) at 0.8 V.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A power-efficient multi-channel PPG ASIC with 112dB receiver DR for pulse oximetry and NIRS
We report a photo-plethysmography ASIC realised in a 130nm CMOS technology, which supports multi-channel probe configurations with up to 32 LEDs and 4 photodiodes. The receiver can cover a wide range of (full-scale) input signal strengths between 13nA and 63μA. In a typical pulse oximetry application (0.1-20Hz), overall loop dynamic range is 96dB, with noise contributions by the driver, LED, photodiode and receiver all taken into account. Total power consumption is 5.9mW, including two LEDs pulsed at 600Hz and 50mA. Compared to the state-of-the-art a saving of 68% has been achieved for equal signal quality.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A power-efficient multi-channel PPG ASIC with 112dB receiver DR for pulse oximetry and NIRS
We report a photo-plethysmography ASIC realised in a 130nm CMOS technology, which supports multi-channel probe configurations with up to 32 LEDs and 4 photodiodes. The receiver can cover a wide range of (full-scale) input signal strengths between 13nA and 63μA. In a typical pulse oximetry application (0.1-20Hz), overall loop dynamic range is 96dB, with noise contributions by the driver, LED, photodiode and receiver all taken into account. Total power consumption is 5.9mW, including two LEDs pulsed at 600Hz and 50mA. Compared to the state-of-the-art a saving of 68% has been achieved for equal signal quality.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2016, 4439-4442
A wireless system with stimulation and recording capabilities for interfacing peripheral nerves in rodents
Considerable progress has been made in the last decade in implantable bioelectronic neurosystems. Yet most neural implants are used in acute and tethered experimental conditions. Here, we present a preliminary prototype of a multichannel system for simultaneous peripheral nerve stimulation and neural recording. The system comprises miniaturized electronics with a total volume of less then 1.4cm3 including a 3.7V battery which is expected to last for 94 days of standby operation or 18 hours of continuous recording and stimulation. Data read-out and device configuration are wireless. Visceral nerves in rodents are interfaced with compliant extraneural electrodes. The 100×350μm2 electrodes display a low impedance (1.8kn at 1kHz) with a PEDOT:PSS coating. We validated the prototype in acute experiments by applying electrical stimulation to the aortic depressor nerve (ADN), resulting in effective and reproducible decrease in blood pressure and heart rate. The combination of miniaturized electronics and flexible electrodes makes the presented system a versatile platform for future implantable devices interfacing small peripheral nerves and potentially enables new applications in the field of neuroscience.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2016, 4439-4442
A wireless system with stimulation and recording capabilities for interfacing peripheral nerves in rodents
Considerable progress has been made in the last decade in implantable bioelectronic neurosystems. Yet most neural implants are used in acute and tethered experimental conditions. Here, we present a preliminary prototype of a multichannel system for simultaneous peripheral nerve stimulation and neural recording. The system comprises miniaturized electronics with a total volume of less then 1.4cm3 including a 3.7V battery which is expected to last for 94 days of standby operation or 18 hours of continuous recording and stimulation. Data read-out and device configuration are wireless. Visceral nerves in rodents are interfaced with compliant extraneural electrodes. The 100×350μm2 electrodes display a low impedance (1.8kn at 1kHz) with a PEDOT:PSS coating. We validated the prototype in acute experiments by applying electrical stimulation to the aortic depressor nerve (ADN), resulting in effective and reproducible decrease in blood pressure and heart rate. The combination of miniaturized electronics and flexible electrodes makes the presented system a versatile platform for future implantable devices interfacing small peripheral nerves and potentially enables new applications in the field of neuroscience.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 62 (11) , 2685-2694
A Reconfigurable 5-to-14 bit SAR ADC for Battery-Powered Medical Instrumentation
In battery-powered medical instrumentation, the resolution and signal bandwidth of analog-to-digital converters (ADCs) have to be adapted to the needs of the application to avoid power wastage. This paper presents a reconfigurable successive approximation register (SAR) ADC implemented in 130 nm CMOS that resolves 5-14 bit with a maximum achievable effective number of bits (ENOB) of 13.5 using non-subtractive dither. In the proposed ADC design, the power consumption can be traded for accuracy to improve the energy efficiency and extend its application range, while reducing system integration complexity. A figure-of-merit (FoM) of 59 fJ/conversion is achieved at 1.2 V supply and the converter occupies an area of 0.42 mm 2 . Measurement results of the ADC integrated in a multi-channel analog front-end (AFE) circuit show the suitability of the ADC for portable medical monitoring devices.
- 1 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 62 (11) , 2685-2694
A Reconfigurable 5-to-14 bit SAR ADC for Battery-Powered Medical Instrumentation
In battery-powered medical instrumentation, the resolution and signal bandwidth of analog-to-digital converters (ADCs) have to be adapted to the needs of the application to avoid power wastage. This paper presents a reconfigurable successive approximation register (SAR) ADC implemented in 130 nm CMOS that resolves 5-14 bit with a maximum achievable effective number of bits (ENOB) of 13.5 using non-subtractive dither. In the proposed ADC design, the power consumption can be traded for accuracy to improve the energy efficiency and extend its application range, while reducing system integration complexity. A figure-of-merit (FoM) of 59 fJ/conversion is achieved at 1.2 V supply and the converter occupies an area of 0.42 mm 2 . Measurement results of the ADC integrated in a multi-channel analog front-end (AFE) circuit show the suitability of the ADC for portable medical monitoring devices.
- 26 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 9 (5) , 620-630
A Versatile Embedded Platform for EMG Acquisition and Gesture Recognition
Wearable devices offer interesting features, such as low cost and user friendliness, but their use for medical applications is an open research topic, given the limited hardware resources they provide. In this paper, we present an embedded solution for real-time EMG-based hand gesture recognition. The work focuses on the multi-level design of the system, integrating the hardware and software components to develop a wearable device capable of acquiring and processing EMG signals for real-time gesture recognition. The system combines the accuracy of a custom analog front end with the flexibility of a low power and high performance microcontroller for on-board processing. Our system achieves the same accuracy of high-end and more expensive active EMG sensors used in applications with strict requirements on signal quality. At the same time, due to its flexible configuration, it can be compared to the few wearable platforms designed for EMG gesture recognition available on market. We demonstrate that we reach similar or better performance while embedding the gesture recognition on board, with the benefit of cost reduction. To validate this approach, we collected a dataset of 7 gestures from 4 users, which were used to evaluate the impact of the number of EMG channels, the number of recognized gestures and the data rate on the recognition accuracy and on the computational demand of the classifier. As a result, we implemented a SVM recognition algorithm capable of real-time performance on the proposed wearable platform, achieving a classification rate of 90%, which is aligned with the state-of-the-art off-line results and a 29.7 mW power consumption, guaranteeing 44 hours of continuous operation with a 400 mAh battery.
- 26 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 9 (5) , 620-630
A Versatile Embedded Platform for EMG Acquisition and Gesture Recognition
Wearable devices offer interesting features, such as low cost and user friendliness, but their use for medical applications is an open research topic, given the limited hardware resources they provide. In this paper, we present an embedded solution for real-time EMG-based hand gesture recognition. The work focuses on the multi-level design of the system, integrating the hardware and software components to develop a wearable device capable of acquiring and processing EMG signals for real-time gesture recognition. The system combines the accuracy of a custom analog front end with the flexibility of a low power and high performance microcontroller for on-board processing. Our system achieves the same accuracy of high-end and more expensive active EMG sensors used in applications with strict requirements on signal quality. At the same time, due to its flexible configuration, it can be compared to the few wearable platforms designed for EMG gesture recognition available on market. We demonstrate that we reach similar or better performance while embedding the gesture recognition on board, with the benefit of cost reduction. To validate this approach, we collected a dataset of 7 gestures from 4 users, which were used to evaluate the impact of the number of EMG channels, the number of recognized gestures and the data rate on the recognition accuracy and on the computational demand of the classifier. As a result, we implemented a SVM recognition algorithm capable of real-time performance on the proposed wearable platform, achieving a classification rate of 90%, which is aligned with the state-of-the-art off-line results and a 29.7 mW power consumption, guaranteeing 44 hours of continuous operation with a 400 mAh battery.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An EOG-based, head-mounted eye tracker with 1 kHz sampling rate
The observation of eye movements has become a widely accepted technique in several research areas and the demand for mobile, out-of-lab eye trackers has steadily increased. Most of these head-mounted systems use videooculography (VOG) to record eye movements. VOG systems operate on low sampling rates around 30 to 60 Hz. Sampling rates this low, can hamper the undistorted analysis of the dynamic properties of eye movements. This paper presents an electrooculography (EOG) based, head-mounted eye tracker with a sampling rate of 1kHz - a temporal resolution high enough for acquisition of all eye movements and their dynamic properties (e.g. peak velocity). A compact data acquisition device stores the data and provides a real-time preview on a mobile device. The system achieves a EOG-inherent spatial resolution of 1.6 °. A wide-angle scene camera enables the recording of the participant's field of view. The system is intended as out-of-lab eye tracker, for example in the context of an objective fitness-to-drive test for the elderly, and poses a high sampling alternative to VOG-based eye trackers.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
An EOG-based, head-mounted eye tracker with 1 kHz sampling rate
The observation of eye movements has become a widely accepted technique in several research areas and the demand for mobile, out-of-lab eye trackers has steadily increased. Most of these head-mounted systems use videooculography (VOG) to record eye movements. VOG systems operate on low sampling rates around 30 to 60 Hz. Sampling rates this low, can hamper the undistorted analysis of the dynamic properties of eye movements. This paper presents an electrooculography (EOG) based, head-mounted eye tracker with a sampling rate of 1kHz - a temporal resolution high enough for acquisition of all eye movements and their dynamic properties (e.g. peak velocity). A compact data acquisition device stores the data and provides a real-time preview on a mobile device. The system achieves a EOG-inherent spatial resolution of 1.6 °. A wide-angle scene camera enables the recording of the participant's field of view. The system is intended as out-of-lab eye tracker, for example in the context of an objective fitness-to-drive test for the elderly, and poses a high sampling alternative to VOG-based eye trackers.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21634025,p. 57-60
EMG-based hand gesture recognition with flexible analog front end
Conditioning and processing of biological signals represent interesting challenges for wearable electronics in health applications. Information gathering from these signals requires complex hardware circuitry and dedicated computation resources. The design of innovative analog front-end integrated circuits, combined with efficient signal processing algorithms, allows the development of platforms for monitoring, activity and gesture recognition based on embedded real-time systems. This paper describes an Electromyography pattern recognition system based on the combination of low cost passive sensors, an innovative analog front-end and a low power microcontroller. The performance of the proposed system matches state-of-the-art high-end active sensors, opening the way to the development of affordable and accurate wearable devices.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21634025,p. 57-60
EMG-based hand gesture recognition with flexible analog front end
Conditioning and processing of biological signals represent interesting challenges for wearable electronics in health applications. Information gathering from these signals requires complex hardware circuitry and dedicated computation resources. The design of innovative analog front-end integrated circuits, combined with efficient signal processing algorithms, allows the development of platforms for monitoring, activity and gesture recognition based on embedded real-time systems. This paper describes an Electromyography pattern recognition system based on the combination of low cost passive sensors, an innovative analog front-end and a low power microcontroller. The performance of the proposed system matches state-of-the-art high-end active sensors, opening the way to the development of affordable and accurate wearable devices.