Antoni Nowakowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Antoni Nowakowski has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Mariusz Kaczmarek
Gdansk University of Technology
23 shared publications - Piotr Jasinski
Faculty of Electronics, Telecommunications and Informatics, and Advanced Materials Centre, Gdansk University of Technology, 80-233 Gdańsk, Poland
11 shared publications - Jacek Ruminski
Department of Biomedical Engineering, Gdansk University of Technology, Gdansk, Poland
10 shared publications - Jerzy Wtorek
Biomedical Engineering Department, Faculty of Electronics, Telecommunication and Informatics, Gdansk University of Technology, 80-233 Gdansk, Poland
10 shared publications - Grzegorz Jasinski
Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology, Gdansk, Poland
9 shared publications - Janusz Siebert
Medical University of Gdansk, Gdańsk, Poland (Department of Family Medicine)
9 shared publications
Latest Publications
- Top Cited PapersOpen Access
Artificial Intelligence in IR Thermal Imaging and Sensing for Medical Applications
The state of the art in IR thermal imaging methods for applications in medical diagnostics is discussed. A review of advances in IR thermal imaging technology in the years 1960–2024 is presented. Recently used artificial intelligence (AI) methods in the analysis of thermal images are the main interest. IR thermography is discussed in view of novel applications of machine learning methods for improved diagnostic analysis and medical treatment. The AI approach aims to improve image quality by denoising thermal images, using applications of AI super-resolution algorithms, removing artifacts, object detection, face and characteristic features localization, complex matching of diagnostic symptoms, etc.
Top Cited PapersOpen AccessArtificial Intelligence in IR Thermal Imaging and Sensing for Medical Applications
The state of the art in IR thermal imaging methods for applications in medical diagnostics is discussed. A review of advances in IR thermal imaging technology in the years 1960–2024 is presented. Recently used artificial intelligence (AI) methods in the analysis of thermal images are the main interest. IR thermography is discussed in view of novel applications of machine learning methods for improved diagnostic analysis and medical treatment. The AI approach aims to improve image quality by denoising thermal images, using applications of AI super-resolution algorithms, removing artifacts, object detection, face and characteristic features localization, complex matching of diagnostic symptoms, etc.
- 13 September 2021
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 25 (3) , 51-56
Problems of Active Dynamic Thermography Measurement Standardization in Medicine
Reliability of thermographic diagnostics in medicine is an important practical problem. In the field of static thermography, a great deal of effort has been made to define the conditions for thermographic measurements, which is now the golden standard for such research. In recent years, there are more and more reports on dynamic tests with external stimulation, such as Active Dynamic Thermography, Thermographic Signal Reconstruction or Thermal Tomography. The subject of this report is a discussion of the problems of standardization of dynamic tests, the choice of the method of thermal stimulation and the conditions determining the credibility of such tests in medical diagnostics. Typical methods of thermal stimulation are discussed, problems concerning accuracy and control of resulting distributions of temperature are commented. The best practices to get reliable conditions of measurements are summarized.
- 13 September 2021
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 25 (3) , 51-56
Problems of Active Dynamic Thermography Measurement Standardization in Medicine
Reliability of thermographic diagnostics in medicine is an important practical problem. In the field of static thermography, a great deal of effort has been made to define the conditions for thermographic measurements, which is now the golden standard for such research. In recent years, there are more and more reports on dynamic tests with external stimulation, such as Active Dynamic Thermography, Thermographic Signal Reconstruction or Thermal Tomography. The subject of this report is a discussion of the problems of standardization of dynamic tests, the choice of the method of thermal stimulation and the conditions determining the credibility of such tests in medical diagnostics. Typical methods of thermal stimulation are discussed, problems concerning accuracy and control of resulting distributions of temperature are commented. The best practices to get reliable conditions of measurements are summarized.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 54-59
Using Eye-tracking to get information on the skills acquisition by the radiology residents
This paper describes the possibility of monitoring the progress of knowledge and skills acquisition by the students of radiology. It is achieved by an analysis of a visual attention distribution patterns during image-based tasks solving. The concept is to use the eye-tracking data to recognize the way how the radiographic images are read by recognized experts, radiography residents involved in the training program, and untrained users who graduated from biomedical engineering. The results of research presented in this paper support the usefulness of earlier elaborated eye metrics, Visual Attention Time Product VATP, for skills measurement when using Electronic Medical Record for CT images evaluation. Moreover, it appears that it is possible to differentiate the level of residents skills in radiology structures recognition. Presented methodology can also be utilized in other areas where operator performs image related tasks.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 54-59
Using Eye-tracking to get information on the skills acquisition by the radiology residents
This paper describes the possibility of monitoring the progress of knowledge and skills acquisition by the students of radiology. It is achieved by an analysis of a visual attention distribution patterns during image-based tasks solving. The concept is to use the eye-tracking data to recognize the way how the radiographic images are read by recognized experts, radiography residents involved in the training program, and untrained users who graduated from biomedical engineering. The results of research presented in this paper support the usefulness of earlier elaborated eye metrics, Visual Attention Time Product VATP, for skills measurement when using Electronic Medical Record for CT images evaluation. Moreover, it appears that it is possible to differentiate the level of residents skills in radiology structures recognition. Presented methodology can also be utilized in other areas where operator performs image related tasks.
- Open Access
- 29 January 2016
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 35 (1) , 1-16
Active IR-Thermal Imaging in Medicine
- 29 January 2016
- Published by Springer Nature in Journal of Nondestructive Evaluation
- Vol. 35 (1) , 1-16
Open AccessActive IR-Thermal Imaging in Medicine
- 15 September 2015
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 13 (1) , 19-34
A new diagnostic method for evaluation of cardiosurgery wound healing
One of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT descriptors are compared from the point of view of objective, quantitative estimation of wound state. Temporal properties of thermal transients are proposed for objective quantitative description of a tested wound and for classification of healing processes as normal or suspected, requesting a special care. Algorithms enabling evaluation of surgical wound healing process are discussed in terms of possible implementation of the method into clinical practice for proper classification of patients for discharging from a hospital and further treatment at home or for prolonged treatment at the hospital.
- 15 September 2015
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 13 (1) , 19-34
A new diagnostic method for evaluation of cardiosurgery wound healing
One of important and still unsolved problems in medicine is the question of objective and quantitative evaluation of post-surgery wound healing. The aim of this research is to analyse possibility and value of using the newly elaborated infrared imaging procedure – Active Dynamic Thermography (ADT) – for quantitative description of wound healing processes in cardiosurgery. Both, classical thermal figures of merit as well as ADT descriptors are compared from the point of view of objective, quantitative estimation of wound state. Temporal properties of thermal transients are proposed for objective quantitative description of a tested wound and for classification of healing processes as normal or suspected, requesting a special care. Algorithms enabling evaluation of surgical wound healing process are discussed in terms of possible implementation of the method into clinical practice for proper classification of patients for discharging from a hospital and further treatment at home or for prolonged treatment at the hospital.
- 1 September 2014
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 35 (5) , e294-e303
Active Dynamic Infrared Thermal Imaging in Burn Depth Evaluation
The aim of this study was to find the relationship between active dynamic thermography (ADT) with cold excitation and burn depth. This new modality of evaluation of burns seems to be an attractive proposal for quantitative classification, allowing proper choice of burn wound treatment: conservative or surgical, especially compared with static thermography. The work was an in vivo experiment on domestic pigs, and a small number of patients were also diagnosed as part of the study. Statistical analysis showed a high correlation between the ADT synthetic parameter—thermal time constant, τ—and the classification of burn wounds that were predicted to heal within 3 weeks and so were treated conservatively and those that were predicted to not heal within 3 weeks and so were surgically treated. The results of the study show an accuracy of 60.7% for clinical evaluation, 69.6% for static thermography, 83.0% for ADT, and 84.0% for histopathologic assessment. The authors have concluded that the ADT method with cold excitation is suitable for the qualitative and quantitative assessment of burn depth.
- 1 September 2014
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 35 (5) , e294-e303
Active Dynamic Infrared Thermal Imaging in Burn Depth Evaluation
The aim of this study was to find the relationship between active dynamic thermography (ADT) with cold excitation and burn depth. This new modality of evaluation of burns seems to be an attractive proposal for quantitative classification, allowing proper choice of burn wound treatment: conservative or surgical, especially compared with static thermography. The work was an in vivo experiment on domestic pigs, and a small number of patients were also diagnosed as part of the study. Statistical analysis showed a high correlation between the ADT synthetic parameter—thermal time constant, τ—and the classification of burn wounds that were predicted to heal within 3 weeks and so were treated conservatively and those that were predicted to not heal within 3 weeks and so were surgically treated. The results of the study show an accuracy of 60.7% for clinical evaluation, 69.6% for static thermography, 83.0% for ADT, and 84.0% for histopathologic assessment. The authors have concluded that the ADT method with cold excitation is suitable for the qualitative and quantitative assessment of burn depth.
- 1 January 2014
- Published by Springer Nature
- p. 197-202
Active Dynamic Thermography Imaging of Wound Healing Processes in Cardio Surgery
- 1 January 2014
- Published by Springer Nature
- p. 197-202
Active Dynamic Thermography Imaging of Wound Healing Processes in Cardio Surgery
- Open Access
- 1 January 2012
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 19 (2) , 231-244
Assessment of Cardiovascular Risk in Assisted Living
Disorders of the heart and blood vessels are the leading cause of health problems and death. Early detection of them is extremely valuable as it can prevent serious incidents (e.g. heart attack, stroke) and associated complications. This requires extending the typical mobile monitoring methods (e.g. Holter ECG, tele-ECG) by introduction of integrated, multiparametric solutions for continuous monitoring of the cardiovascular system. In this paper we propose the wearable system that integrates measurements of cardiac data with actual estimation of the cardiovascular risk level. It consists of two wirelessly connected devices, one designed in the form of a necklace, the another one in the form of a bracelet (wrist watch). These devices enable continuous measurement of electrocardiographic, plethysmographic (impedance-based and optical-based) and accelerometric signals. Collected signals and calculated parameters indicate the electrical and mechanical state of the heart and are processed to estimate a risk level. Depending on the risk level an appropriate alert is triggered and transmitted to predefined users (e.g. emergency departments, the family doctor, etc.).
- 1 January 2012
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 19 (2) , 231-244
Open AccessAssessment of Cardiovascular Risk in Assisted Living
Disorders of the heart and blood vessels are the leading cause of health problems and death. Early detection of them is extremely valuable as it can prevent serious incidents (e.g. heart attack, stroke) and associated complications. This requires extending the typical mobile monitoring methods (e.g. Holter ECG, tele-ECG) by introduction of integrated, multiparametric solutions for continuous monitoring of the cardiovascular system. In this paper we propose the wearable system that integrates measurements of cardiac data with actual estimation of the cardiovascular risk level. It consists of two wirelessly connected devices, one designed in the form of a necklace, the another one in the form of a bracelet (wrist watch). These devices enable continuous measurement of electrocardiographic, plethysmographic (impedance-based and optical-based) and accelerometric signals. Collected signals and calculated parameters indicate the electrical and mechanical state of the heart and are processed to estimate a risk level. Depending on the risk level an appropriate alert is triggered and transmitted to predefined users (e.g. emergency departments, the family doctor, etc.).
- 1 June 2011
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 8 (1)
Active Dynamic Thermography - Problems of implementation in medical diagnostics
- 1 June 2011
- Published by Taylor & Francis in Quantitative InfraRed Thermography Journal
- Vol. 8 (1)
Active Dynamic Thermography - Problems of implementation in medical diagnostics
- 1 January 2011
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 18 (1) , 91-104
Comparison of Tracking Methods in Respect of Automation of an Animal Behavioral Test
- 1 January 2011
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 18 (1) , 91-104
Comparison of Tracking Methods in Respect of Automation of an Animal Behavioral Test