Adewole Michael Gbadebo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Adewole Michael Gbadebo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
A.S. Okedeyi
3 shared publicationsA.M Taiwo
2 shared publicationsA.O. Mustapha
2 shared publications- Benjamin Onozeyi Dimowo
Department of Environmental Management and Toxicology, College of Environmental Resources Management, Federal University of Agriculture, Abeokuta, Nigeria
2 shared publications J.A Awomeso
2 shared publicationsKudirat Akorede Otubu
2 shared publications
Latest Publications
- Open Access
- 10 July 2026
- Published by Mediterranean Publications and Research International in International Journal of Environmental Research and Earth Science
EVALUATING MICROBIAL AND PHYSICOCHEMICAL CONTAMINATION OF GROUNDWATER IN SOUTHWESTERN NIGERIA AND THE FEDERAL CAPITAL TERRITORY: A REGULATORY COMPLIANCE ASSESSMENT
Microbial contamination renders groundwater unsafe and scarce. This study assessed groundwater quality across Lagos, Ogun, Oyo, Osun, Ondo, Ekiti States, and the Federal Capital Territory to evaluate compliance with water quality guidelines of the World Health Organization (WHO), Standard Organization of Nigeria (SON), and the National Environmental Standards and Regulations Enforcement Agency (NESREA). A total of 450 samples from 49 towns were analyzed for physical (temperature, electrical conductivity), chemical (magnesium, calcium, total hardness), and microbiological (bacterial load, faecal coliforms, pathogenic bacteria, protozoans) parameters using standard methods. Results revealed widespread contamination with total hardness (258.11±58.33 - 572.06±63.82 mg/L) and bacterial load (1.67±4.08 t- 37,241.00±113,412.90 cfu/mL) exceeding regulatory limits. Faecal coliforms were found in 30.22% of samples. Among 11 bacterial species isolated, Enterobacter aerogenes (52.7%), Klebsiella pneumoniae (31.8%), and Escherichia coli (30.7%) predominated. Entamoeba histolytica, a pathogenic protozoan was found in 15% of samples. Water Quality Index classified 9.33% of sources as “excellent,” 15.56% “good,” 9.33% “poor,” 2.89% “very poor,” and 62.89% “unsuitable” for use without treatment. Principal Component Analysis identified bacterial load as the key parameter (Loading: 1.00; PC1: 99.98% variance) influencing water quality. It was recommended that improved sanitation infrastructure, regulatory monitoring and treatment be implemented to safeguard public health.
- 10 July 2026
- Published by Mediterranean Publications and Research International in International Journal of Environmental Research and Earth Science
Open AccessEVALUATING MICROBIAL AND PHYSICOCHEMICAL CONTAMINATION OF GROUNDWATER IN SOUTHWESTERN NIGERIA AND THE FEDERAL CAPITAL TERRITORY: A REGULATORY COMPLIANCE ASSESSMENT
Microbial contamination renders groundwater unsafe and scarce. This study assessed groundwater quality across Lagos, Ogun, Oyo, Osun, Ondo, Ekiti States, and the Federal Capital Territory to evaluate compliance with water quality guidelines of the World Health Organization (WHO), Standard Organization of Nigeria (SON), and the National Environmental Standards and Regulations Enforcement Agency (NESREA). A total of 450 samples from 49 towns were analyzed for physical (temperature, electrical conductivity), chemical (magnesium, calcium, total hardness), and microbiological (bacterial load, faecal coliforms, pathogenic bacteria, protozoans) parameters using standard methods. Results revealed widespread contamination with total hardness (258.11±58.33 - 572.06±63.82 mg/L) and bacterial load (1.67±4.08 t- 37,241.00±113,412.90 cfu/mL) exceeding regulatory limits. Faecal coliforms were found in 30.22% of samples. Among 11 bacterial species isolated, Enterobacter aerogenes (52.7%), Klebsiella pneumoniae (31.8%), and Escherichia coli (30.7%) predominated. Entamoeba histolytica, a pathogenic protozoan was found in 15% of samples. Water Quality Index classified 9.33% of sources as “excellent,” 15.56% “good,” 9.33% “poor,” 2.89% “very poor,” and 62.89% “unsuitable” for use without treatment. Principal Component Analysis identified bacterial load as the key parameter (Loading: 1.00; PC1: 99.98% variance) influencing water quality. It was recommended that improved sanitation infrastructure, regulatory monitoring and treatment be implemented to safeguard public health.
- Open Access
- 30 June 2026
- Published by African Tulip Academic Press in African Journal of Environmental Sciences and Renewable Energy
- Vol. 23 (1) , 166-206
Hydrogeochemical Assessment of Groundwater in Epe (Nigeria) for Drinking and Irrigation Purposes
Groundwater sustainability demands routine quality monitoring. This study assessed the hydrogeochemistry of groundwater in Epe, Lagos State, to evaluate its suitability for drinking and irrigation. Fifty well-water samples from eight communities were analyzed for pH and major ions. Results showed that parameters complied with regulatory standards in most locations except magnesium (65.70±23.50 - 96.00±19.68 mg/L) which consistently exceeded the Nigerian Standard for Drinking Water Quality of 20 mg/L. Dietary intake of essential elements was generally negligible, though magnesium levels in Poka exceeded recommended daily allowance for infants (0-6 months). The Water Quality Index (40.41 - 128.49) classified the water as 8% “excellent,” 76% "good," and 16% "poor" while the Pollution Index of Groundwater (0.39 - 0.85) ranked all samples as having insignificant pollution. Though, majority of the irrigation indices indicated suitability for irrigation; Permeability Index (50% in 86% samples) and Corrosivity Ratio (>1 in 50% samples) presented risks to long-term soil permeability and metallic water transport pipes. The ionic dominance was Mg²⁺>Ca²⁺>Na⁺>K⁺ and HCO₃⁻>SO₄²⁻>Cl⁻. Geochemical diagrams (Piper, Chadha and Schoeller diagrams) revealed a Ca-Mg-HCO₃ facies, attributed to mixed carbonate-silicate weathering (Gaillardet diagram), rock-water interaction (Gibb’s diagram) and ion exchange (CAI, CAII), with the Hydrochemical Facies Evolution Diagram indicating mixed facies. Principal Component Analysis identified bicarbonate (PC1: 57.33%), calcium (PC2: 17.35%), sulphate (PC3: 15.94%) and magnesium (PC4: 8.38%) as the primary factors controlling water quality. The study recommends water treatment, the use of corrosion-resistant pipes, and sustained monitoring to safeguard this resource.
- 30 June 2026
- Published by African Tulip Academic Press in African Journal of Environmental Sciences and Renewable Energy
- Vol. 23 (1) , 166-206
Open AccessHydrogeochemical Assessment of Groundwater in Epe (Nigeria) for Drinking and Irrigation Purposes
Groundwater sustainability demands routine quality monitoring. This study assessed the hydrogeochemistry of groundwater in Epe, Lagos State, to evaluate its suitability for drinking and irrigation. Fifty well-water samples from eight communities were analyzed for pH and major ions. Results showed that parameters complied with regulatory standards in most locations except magnesium (65.70±23.50 - 96.00±19.68 mg/L) which consistently exceeded the Nigerian Standard for Drinking Water Quality of 20 mg/L. Dietary intake of essential elements was generally negligible, though magnesium levels in Poka exceeded recommended daily allowance for infants (0-6 months). The Water Quality Index (40.41 - 128.49) classified the water as 8% “excellent,” 76% "good," and 16% "poor" while the Pollution Index of Groundwater (0.39 - 0.85) ranked all samples as having insignificant pollution. Though, majority of the irrigation indices indicated suitability for irrigation; Permeability Index (50% in 86% samples) and Corrosivity Ratio (>1 in 50% samples) presented risks to long-term soil permeability and metallic water transport pipes. The ionic dominance was Mg²⁺>Ca²⁺>Na⁺>K⁺ and HCO₃⁻>SO₄²⁻>Cl⁻. Geochemical diagrams (Piper, Chadha and Schoeller diagrams) revealed a Ca-Mg-HCO₃ facies, attributed to mixed carbonate-silicate weathering (Gaillardet diagram), rock-water interaction (Gibb’s diagram) and ion exchange (CAI, CAII), with the Hydrochemical Facies Evolution Diagram indicating mixed facies. Principal Component Analysis identified bicarbonate (PC1: 57.33%), calcium (PC2: 17.35%), sulphate (PC3: 15.94%) and magnesium (PC4: 8.38%) as the primary factors controlling water quality. The study recommends water treatment, the use of corrosion-resistant pipes, and sustained monitoring to safeguard this resource.
- 1 March 2016
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 304, 166-172
Bioremediation of industrially contaminated soil using compost and plant technology
- 1 March 2016
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 304, 166-172
Bioremediation of industrially contaminated soil using compost and plant technology
- 14 May 2015
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 187 (6) , 1-17
Toxic elements in groundwater of Lagos and Ogun States, Southwest, Nigeria and their human health risk assessment
A good quality drinking water is essential for human survival. However, a large percentage of the populations in most developing countries (Nigeria inclusive) do not have access to potable water. This study was therefore conducted to assess the extent of risk arising from consumption of toxic elements in groundwater samples collected from Lagos and Ogun States, Southwest, Nigeria. Twelve toxic elements concentrations (As, Mn, Cd, Cr, Pb, Ni, Al, Ti, V, Hg, Li, and Sn) were determined from 170 groundwater samples using inductively coupled plasma-mass spectrometry, and the physicochemical parameters were determined using standard methods. The pH results revealed that most of the water samples were slightly acidic. Of the twelve toxic elements, only Mn, Cd, Pb, Ni, and Al have concentrations higher than the WHO recommended limit in drinking water. The average dose of Mn and Al consumed daily from groundwater by an adult in Lagos state is 3.4 and 23.2 (μg/kg body weight), respectively. Similarly, an adult in Ogun State consumed an average daily dose of 6.09 and 25 (μg/kg body weight) Mn and Al, respectively. A greater threat was posed to children and infants. The order for risk of cancer in groundwater from Lagos State was Pb > Cr > As > Cd while the order in Ogun State groundwater was Cr > Cd > As > Pb. The relative high concentrations of Mn, Al, and Pb obtained in this study can be attributed to industrial and anthropogenic activities in the study area. Treatment of groundwater before consumption is recommended to avoid possible adverse cumulative effect. Improved waste disposal methods and regular monitoring of toxic elements in groundwater of the study area should be adopted to safeguard human health.
- 14 May 2015
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 187 (6) , 1-17
Toxic elements in groundwater of Lagos and Ogun States, Southwest, Nigeria and their human health risk assessment
A good quality drinking water is essential for human survival. However, a large percentage of the populations in most developing countries (Nigeria inclusive) do not have access to potable water. This study was therefore conducted to assess the extent of risk arising from consumption of toxic elements in groundwater samples collected from Lagos and Ogun States, Southwest, Nigeria. Twelve toxic elements concentrations (As, Mn, Cd, Cr, Pb, Ni, Al, Ti, V, Hg, Li, and Sn) were determined from 170 groundwater samples using inductively coupled plasma-mass spectrometry, and the physicochemical parameters were determined using standard methods. The pH results revealed that most of the water samples were slightly acidic. Of the twelve toxic elements, only Mn, Cd, Pb, Ni, and Al have concentrations higher than the WHO recommended limit in drinking water. The average dose of Mn and Al consumed daily from groundwater by an adult in Lagos state is 3.4 and 23.2 (μg/kg body weight), respectively. Similarly, an adult in Ogun State consumed an average daily dose of 6.09 and 25 (μg/kg body weight) Mn and Al, respectively. A greater threat was posed to children and infants. The order for risk of cancer in groundwater from Lagos State was Pb > Cr > As > Cd while the order in Ogun State groundwater was Cr > Cd > As > Pb. The relative high concentrations of Mn, Al, and Pb obtained in this study can be attributed to industrial and anthropogenic activities in the study area. Treatment of groundwater before consumption is recommended to avoid possible adverse cumulative effect. Improved waste disposal methods and regular monitoring of toxic elements in groundwater of the study area should be adopted to safeguard human health.
- 13 September 2014
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 73 (7) , 3633-3642
Hydrogeochemical assessment of groundwater in Iwo, Ikonifin and Ife-Odan, Osun and Oyo states, Southwest Nigeria
- 13 September 2014
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 73 (7) , 3633-3642
Hydrogeochemical assessment of groundwater in Iwo, Ikonifin and Ife-Odan, Osun and Oyo states, Southwest Nigeria
- 15 March 2014
- Published by Science Alert in Journal of Applied Sciences
- Vol. 14 (7) , 691-696
Effects of Physical and Chemical Properties on Natural Radionuclides Level in Soil of Quarry Sites in Ogun State, Nigeria
- 15 March 2014
- Published by Science Alert in Journal of Applied Sciences
- Vol. 14 (7) , 691-696
Effects of Physical and Chemical Properties on Natural Radionuclides Level in Soil of Quarry Sites in Ogun State, Nigeria
- 1 September 2013
- Published by Kamla Raj Enterprises in Journal of Human Ecology
- Vol. 43 (3) , 273-279
Assessment of Dissolved Silica Content of Groundwater from Southwestern Nigeria
The groundwater resources from open dug wells in Abeokuta municipality are mostly abstracted from shallow depth of < 10.0 m with a static water level in the range of 0.2 to 5.0 m. Study was carried out to assess dissolved silica (DSi, SiO2) in these groundwater resources to establish their baseline concentrations. 200 shallow wells were sampled from 47 communities in Abeokuta and parameters namely: Static Water Level (SWL), total depth (TD), pH, total dissolved solids (TDS), electrical conductivity (EC) and DSi were determined. The water pH varied between 6.2 and 8.1 (slightly acidic and slightly alkaline) with appreciable amount of TDS (37.0 - 601.0 mg/l). The groundwater also contains abundant dissolved silica (0.5 - 19.3 mg/l) and EC in the range of 57-1002 μS/cm. Since major source of potable water in the city is groundwater from the open dug wells, it then implies that majority of the residents are exposed to water borne silica on a daily basis. Unlike in the airborne crystalline silica, which has been established to be the cause of silicosis, the health impact of the water borne silica in the municipality is unknown.
- 1 September 2013
- Published by Kamla Raj Enterprises in Journal of Human Ecology
- Vol. 43 (3) , 273-279
Assessment of Dissolved Silica Content of Groundwater from Southwestern Nigeria
The groundwater resources from open dug wells in Abeokuta municipality are mostly abstracted from shallow depth of < 10.0 m with a static water level in the range of 0.2 to 5.0 m. Study was carried out to assess dissolved silica (DSi, SiO2) in these groundwater resources to establish their baseline concentrations. 200 shallow wells were sampled from 47 communities in Abeokuta and parameters namely: Static Water Level (SWL), total depth (TD), pH, total dissolved solids (TDS), electrical conductivity (EC) and DSi were determined. The water pH varied between 6.2 and 8.1 (slightly acidic and slightly alkaline) with appreciable amount of TDS (37.0 - 601.0 mg/l). The groundwater also contains abundant dissolved silica (0.5 - 19.3 mg/l) and EC in the range of 57-1002 μS/cm. Since major source of potable water in the city is groundwater from the open dug wells, it then implies that majority of the residents are exposed to water borne silica on a daily basis. Unlike in the airborne crystalline silica, which has been established to be the cause of silicosis, the health impact of the water borne silica in the municipality is unknown.
- 1 November 2012
- Published by ALOKI Ltd in Applied Ecology and Environmental Research
- Vol. 10 (3) , 375-384
GEOCHEMICAL ANALYSIS OF GROUNDWATER QUALITY IN AGBARA AND ENVIRONS
- 1 November 2012
- Published by ALOKI Ltd in Applied Ecology and Environmental Research
- Vol. 10 (3) , 375-384
GEOCHEMICAL ANALYSIS OF GROUNDWATER QUALITY IN AGBARA AND ENVIRONS
- 1 July 2012
- Published by Science Alert in Asian Journal of Applied Sciences
- Vol. 5 (7) , 506-513
Gamma Radioactivity Levels of Rock and Soil and Their Corresponding External Exposures in Navy Quarry Site, Abeokuta, South-Western, Nigeria
- 1 July 2012
- Published by Science Alert in Asian Journal of Applied Sciences
- Vol. 5 (7) , 506-513
Gamma Radioactivity Levels of Rock and Soil and Their Corresponding External Exposures in Navy Quarry Site, Abeokuta, South-Western, Nigeria
- 27 April 2012
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 34 (5) , 597-604
Groundwater fluoride and dental fluorosis in southwestern Nigeria
This study was carried out to assess the fluoride levels of groundwater from open wells, consumed by the residents of three communities located in two distinct geological terrains of southwestern Nigeria. Fluoride concentration was determined using spectrophotometric technique, while analysis of other parameters like temperature, pH and total dissolve solids followed standard methods. Results of the analysis indicated that groundwater samples from Abeokuta Metropolis (i.e., basement complex terrain) had fluoride content in the range of 0.65 ± 0.21 and 1.20 ± 0.14. These values were found to be lower than the fluoride contents in the groundwater samples from Ewekoro peri-urban and Lagos metropolis where the values ranged between 1.10 ± 0.14–1.45 ± 0.07 and 0.15 ± 0.07–2.20 ± 1.41 mg/l, respectively. The fluoride contents in almost all locations were generally higher than the WHO recommended 0.6 mg/l. Analysis of Duncan multiple range test indicated that there is similarity in the level of significance of fluoride contents between different locations of same geological terrain at p ≤ 0.05. It was also observed that fluoride distribution of groundwater samples from the different geological terrain was more dependent on factors like pH and TDS than on temperature. The result of the analyzed social demographic characteristics of the residents indicated that the adults (between the age of 20 and >40 years) showed dental decay than the adolescent (<20 years). This signifies incidence of dental fluorosis by the high fluoride content in the drinking water of the populace. Further investigation on all sources of drinking water and other causes of tooth decay in the area is suggested.
- 27 April 2012
- Published by Springer Nature in Environmental Geochemistry and Health
- Vol. 34 (5) , 597-604
Groundwater fluoride and dental fluorosis in southwestern Nigeria
This study was carried out to assess the fluoride levels of groundwater from open wells, consumed by the residents of three communities located in two distinct geological terrains of southwestern Nigeria. Fluoride concentration was determined using spectrophotometric technique, while analysis of other parameters like temperature, pH and total dissolve solids followed standard methods. Results of the analysis indicated that groundwater samples from Abeokuta Metropolis (i.e., basement complex terrain) had fluoride content in the range of 0.65 ± 0.21 and 1.20 ± 0.14. These values were found to be lower than the fluoride contents in the groundwater samples from Ewekoro peri-urban and Lagos metropolis where the values ranged between 1.10 ± 0.14–1.45 ± 0.07 and 0.15 ± 0.07–2.20 ± 1.41 mg/l, respectively. The fluoride contents in almost all locations were generally higher than the WHO recommended 0.6 mg/l. Analysis of Duncan multiple range test indicated that there is similarity in the level of significance of fluoride contents between different locations of same geological terrain at p ≤ 0.05. It was also observed that fluoride distribution of groundwater samples from the different geological terrain was more dependent on factors like pH and TDS than on temperature. The result of the analyzed social demographic characteristics of the residents indicated that the adults (between the age of 20 and >40 years) showed dental decay than the adolescent (<20 years). This signifies incidence of dental fluorosis by the high fluoride content in the drinking water of the populace. Further investigation on all sources of drinking water and other causes of tooth decay in the area is suggested.