Seong Chun Kim
Research Subjects
Seong Chun Kim has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Daesung Lim
Department of Emergency Medicine, Gyeongsang National University School of Medicine and Gyeongsang National University Changwon Hospital, Changwon, Gyeongsangnam-Do, Republic of Korea
2 shared publications - Bongkyu Jeong
Changwon Fire Department, Changwon, Korea
1 shared publication Changwoo Kang
1 shared publication- Changwoo Kang
Department of Emergency Medicine, Gyeongsang National University School of Medicine and Gyeongsang National University Hospital, Jinju-si, Gyeongsangnam-do, Republic of Korea
1 shared publication Dong Hoon Kim
1 shared publication- Dong Hoon Kim
Department of Emergency Medicine, Gyeongsang National University School of Medicine and Gyeongsang National University Hospital, Jinju-si, Gyeongsangnam-do, Republic of Korea; Gyeongsang Institute of Health Sciences, Gyeongsang National University School of Medicine, Jinju-si, Gyeongsangnam-do, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 31 January 2026
- Published by Korean Council of EMS Physicians in Journal of EMS Medicine
- Vol. 5 (1) , 1-13
Assessing the need for quality control in direct medical oversight: a survey of emergency medical services providers and medical directors
This study aimed to assess the need for quality control in the direct medical oversight process through a questionnaire survey of medical directors and emergency medical services (EMS) providers. Methods: This prospective survey targeted EMS providers and medical directors. The questionnaire collected information on demographic characteristics and perceptions regarding the need for quality control for direct medical oversight. Differences in perceived need between EMS providers and medical directors with respect to improved quality control for direct medical oversight during prehospital treatment provided by EMS providers were examined. Results: A total of 857 EMS providers and 37 medical directors were included. Among them, 87% of medical directors and 63% of EMS providers reported that the implementation of quality control was needed for direct medical oversight in their region. A higher proportion of medical directors than EMS providers indicated that quality control was necessary, not only for evaluating the performance of EMS providers during the direct medical oversight call process but also for addressing problems related to the performance of medical directors themselves. Only 22% of medical directors and 19% of EMS providers responded that medical directors adequately understood the prehospital situations experienced by EMS providers. In addition, 27% of EMS providers reported having doubts about the instructions received from medical directors during direct medical oversight. Conclusion: The necessity of quality control systems for direct medical oversight was recognized by more than 60% of both medical directors and EMS providers. Local EMS systems should be prepared to develop tools to evaluate the quality of direct medical oversight.
- 31 January 2026
- Published by Korean Council of EMS Physicians in Journal of EMS Medicine
- Vol. 5 (1) , 1-13
Open AccessAssessing the need for quality control in direct medical oversight: a survey of emergency medical services providers and medical directors
This study aimed to assess the need for quality control in the direct medical oversight process through a questionnaire survey of medical directors and emergency medical services (EMS) providers. Methods: This prospective survey targeted EMS providers and medical directors. The questionnaire collected information on demographic characteristics and perceptions regarding the need for quality control for direct medical oversight. Differences in perceived need between EMS providers and medical directors with respect to improved quality control for direct medical oversight during prehospital treatment provided by EMS providers were examined. Results: A total of 857 EMS providers and 37 medical directors were included. Among them, 87% of medical directors and 63% of EMS providers reported that the implementation of quality control was needed for direct medical oversight in their region. A higher proportion of medical directors than EMS providers indicated that quality control was necessary, not only for evaluating the performance of EMS providers during the direct medical oversight call process but also for addressing problems related to the performance of medical directors themselves. Only 22% of medical directors and 19% of EMS providers responded that medical directors adequately understood the prehospital situations experienced by EMS providers. In addition, 27% of EMS providers reported having doubts about the instructions received from medical directors during direct medical oversight. Conclusion: The necessity of quality control systems for direct medical oversight was recognized by more than 60% of both medical directors and EMS providers. Local EMS systems should be prepared to develop tools to evaluate the quality of direct medical oversight.
- Open Access
- 20 September 2021
- Published by The Korean Society of Clinical Microbiology in Annals of Clinical Microbiology
- Vol. 24 (3) , 75-81
Comparison of Blood Culture Parameters between 2 and 10 mL Aerobic Bottles from Patients with Sepsis
Background: Blood volume is the most important parameter for an optimal blood culture; however, the effect of blood volume on blood culture is not clearly understood from patients with sepsis. Methods: Blood cultures were obtained from 1,049 patients (≥ 15 years old) who visited the emergency department (ED). Two sets of 20 mL each was collected from each patient, 12 mL of which was transferred to 2 and 10 mL FA Plus (aerobic) bottles (bioMérieux, USA) and the remaining into an FN Plus (anaerobic) bottle. Medical records were reviewed to confirm the diagnosis and clinical significance of the blood culture isolates. The positive rate and time-todetection (TTD) were compared between the 2 and 10 mL groups. Results: Among the 2,098 sets collected, 612 sets (29.2%) were excluded due to inadequate (either too much or too little) blood volume. The positive rate of clinically significant pathogens was lower in the 2 mL group (6.1%) than in the 10 mL group (7.5%) ( P = 0.003) among the 1,486 sets. However, there was no significant difference in the positive rate (11.0% vs. 12.5%, P = 0.152) and TTD (15.7 hours vs. 14.2 hours, P = 0.299) among the 585 (39.4%) patients with sepsis. Conclusion: The positive rate and TTD were similar between the 2 and 10 mL groups from patients with sepsis who visited the ED, suggesting a high concentration of bacteremia in this group. Therefore, a smaller blood volume should be carefully considered in patients with sepsis in the ED.
- 20 September 2021
- Published by The Korean Society of Clinical Microbiology in Annals of Clinical Microbiology
- Vol. 24 (3) , 75-81
Open AccessComparison of Blood Culture Parameters between 2 and 10 mL Aerobic Bottles from Patients with Sepsis
Background: Blood volume is the most important parameter for an optimal blood culture; however, the effect of blood volume on blood culture is not clearly understood from patients with sepsis. Methods: Blood cultures were obtained from 1,049 patients (≥ 15 years old) who visited the emergency department (ED). Two sets of 20 mL each was collected from each patient, 12 mL of which was transferred to 2 and 10 mL FA Plus (aerobic) bottles (bioMérieux, USA) and the remaining into an FN Plus (anaerobic) bottle. Medical records were reviewed to confirm the diagnosis and clinical significance of the blood culture isolates. The positive rate and time-todetection (TTD) were compared between the 2 and 10 mL groups. Results: Among the 2,098 sets collected, 612 sets (29.2%) were excluded due to inadequate (either too much or too little) blood volume. The positive rate of clinically significant pathogens was lower in the 2 mL group (6.1%) than in the 10 mL group (7.5%) ( P = 0.003) among the 1,486 sets. However, there was no significant difference in the positive rate (11.0% vs. 12.5%, P = 0.152) and TTD (15.7 hours vs. 14.2 hours, P = 0.299) among the 585 (39.4%) patients with sepsis. Conclusion: The positive rate and TTD were similar between the 2 and 10 mL groups from patients with sepsis who visited the ED, suggesting a high concentration of bacteremia in this group. Therefore, a smaller blood volume should be carefully considered in patients with sepsis in the ED.
- 1 June 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (6) , 1013-1019
The ratio of N-terminal pro-B-type natriuretic peptide to troponin I for differentiating acute coronary syndrome
- 1 June 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (6) , 1013-1019
The ratio of N-terminal pro-B-type natriuretic peptide to troponin I for differentiating acute coronary syndrome
- Open Access
- 30 December 2017
- Published by Korean Society of Pediatric Emergency Medicine in Pediatric Emergency Medicine Journal
- Vol. 4 (2) , 79-84
Establishment of peripheral intravenous catheter for pediatric patients in the emergency department: who and how?
- 30 December 2017
- Published by Korean Society of Pediatric Emergency Medicine in Pediatric Emergency Medicine Journal
- Vol. 4 (2) , 79-84
Open AccessEstablishment of peripheral intravenous catheter for pediatric patients in the emergency department: who and how?