George T. Gillies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
George T. Gillies has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Gianfranco Spavieri
Centro de Física Fundamental, Universidad de Los Andes, Mérida, Venezuela
3 shared publications - Matthew A. Howard
Department of Neurosurgery, University of Iowa
3 shared publications - Chandan G. Reddy
Department of Neurosurgery, University of Iowa Carver College of Medicine, Iowa City, IA, USA
2 shared publications - Douglas C. Fredericks
University of Iowa
2 shared publications - Sina Safayi
Department of Veterinary Clinical Sciences, Iowa State University, Ames, IA, USA
2 shared publications A. Klarmann Staudt
A Department of Veterinary Clinical Sciences , Iowa State University , Ames , IA , USA
1 shared publication
Latest Publications
- Open Access
- 20 February 2021
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 68 (4) , 202-216
The Sagnac effect and the role of simultaneity in relativity theory
We thoroughly examine the role of absolute and relative simultaneity in the interpretation of the Sagnac effect, using an approach that allows for determining the local speed along the light path. If the local speed of light is assumed to be c over the whole closed contour, there is no agreement with the observed result. There is agreement if the local speed is c along an open section of the contour only. Thus a rigorous and coherent interpretation of the Sagnac effect favours absolute over relative simultaneity. The implications for the Lorentz transformations and synchronization by means of the Global Positioning System are considered.
- 20 February 2021
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 68 (4) , 202-216
Open AccessThe Sagnac effect and the role of simultaneity in relativity theory
We thoroughly examine the role of absolute and relative simultaneity in the interpretation of the Sagnac effect, using an approach that allows for determining the local speed along the light path. If the local speed of light is assumed to be c over the whole closed contour, there is no agreement with the observed result. There is agreement if the local speed is c along an open section of the contour only. Thus a rigorous and coherent interpretation of the Sagnac effect favours absolute over relative simultaneity. The implications for the Lorentz transformations and synchronization by means of the Global Positioning System are considered.
- 31 October 2018
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (3) , 240-251
The Hemisection Approach in Large Animal Models of Spinal Cord Injury: Overview of Methods and Applications
Introduction: Translating basic science research into a safe and effective therapy for spinal cord injury (SCI) requires suitable large animal models for testing both implantable devices and biologic approaches to better approximate human anatomy and function. Hemisection lesions, routinely used for investigational purposes in small animals, are less frequently described in large animals that might be appropriate for translational studies. Size constraints of small animals (mice and rats) limits the predictability of the findings when scaled up. Our goal is to review the status of hemisection SCI in large animals across species and time to prepare for the testing of a novel intradural spinal cord stimulation device for control of spasticity in an ovine model. Methods and Results: We surveyed the literature on hemisection in quadrupeds and nonhuman primates, and catalogued the species, protocols and outcomes of the experimental work in this field. Feline, lapine, canine, simian, porcine, ovine and bovine models were the primary focal points. There is a consistent body of literature reporting use of the hemisection approach in large animals, but with differences in surgical technique depending on the goals and nature of the individual studies. While the injuries are not always consistent, the experimental variability is generally lower than that of the contusion-based approach. In general, as the body size of the animal increases, animal care requirements and the associated costs follow. In most cases, this is inversely correlated with the number of animals used in hemisection models. Conclusions: The hemisection approach to modeling SCI is straightforward compared with other methods such as the contusive impact and enables the transection of isolated ascending and descending tracts and segment specific cell bodies. This has certain advantages in models investigating post-injury axonal regrowth. However, this approach is not generally in line with the patho-physiologies encountered in SCI patients. Even so, the ability to achieve more control over the level of injury makes it a useful adjunct to contusive and ischemic approaches, and suggests a useful role in future translational studies.
- 31 October 2018
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (3) , 240-251
The Hemisection Approach in Large Animal Models of Spinal Cord Injury: Overview of Methods and Applications
Introduction: Translating basic science research into a safe and effective therapy for spinal cord injury (SCI) requires suitable large animal models for testing both implantable devices and biologic approaches to better approximate human anatomy and function. Hemisection lesions, routinely used for investigational purposes in small animals, are less frequently described in large animals that might be appropriate for translational studies. Size constraints of small animals (mice and rats) limits the predictability of the findings when scaled up. Our goal is to review the status of hemisection SCI in large animals across species and time to prepare for the testing of a novel intradural spinal cord stimulation device for control of spasticity in an ovine model. Methods and Results: We surveyed the literature on hemisection in quadrupeds and nonhuman primates, and catalogued the species, protocols and outcomes of the experimental work in this field. Feline, lapine, canine, simian, porcine, ovine and bovine models were the primary focal points. There is a consistent body of literature reporting use of the hemisection approach in large animals, but with differences in surgical technique depending on the goals and nature of the individual studies. While the injuries are not always consistent, the experimental variability is generally lower than that of the contusion-based approach. In general, as the body size of the animal increases, animal care requirements and the associated costs follow. In most cases, this is inversely correlated with the number of animals used in hemisection models. Conclusions: The hemisection approach to modeling SCI is straightforward compared with other methods such as the contusive impact and enables the transection of isolated ascending and descending tracts and segment specific cell bodies. This has certain advantages in models investigating post-injury axonal regrowth. However, this approach is not generally in line with the patho-physiologies encountered in SCI patients. Even so, the ability to achieve more control over the level of injury makes it a useful adjunct to contusive and ischemic approaches, and suggests a useful role in future translational studies.
- Open Access
- 1 June 2018
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 11, 1147-1162
Ovine model of neuropathic pain for assessing mechanisms of spinal cord stimulation therapy via dorsal horn recordings, von Frey filaments, and gait analysis
Background: It is becoming increasingly important to understand the mechanisms of spinal cord stimulation (SCS) in alleviating neuropathic pain as novel stimulation paradigms arise. Purpose: Additionally, the small anatomic scale of current SCS animal models is a barrier to more translational research. Methods: Using chronic constriction injury (CCI) of the common peroneal nerve (CPN) in sheep (ovine), we have created a chronic model of neuropathic pain that avoids motor deficits present in prior large animal models. This large animal model has allowed us to implant clinical grade SCS hardware, which enables both acute and chronic testing using von Frey filament thresholds and gait analysis. Furthermore, the larger anatomic scale of the sheep allows for simultaneous single-unit recordings from the dorsal horn and SCS with minimal electrical artifact. Results: Detectable tactile hypersensitivity occurred 21 days after nerve injury, with preliminary indications that chronic SCS may reverse it in the painful limb. Gait analysis revealed no hoof drop in the CCI model. Single neurons were identified and discriminated in the dorsal horn, and their activity was modulated via SCS. Unlike previous large animal models that employed a complete transection of the nerve, no motor deficit was observed in the sheep with CCI. Conclusion: To our knowledge, this is the first reported large animal model of chronic neuropathic pain which facilitates the study of both acute and chronic SCS using complementary behavioral and electrophysiologic measures. As demonstrated by our successful establishment of these techniques, an ovine model of neuropathic pain is suitable for testing the mechanisms of SCS.
- 1 June 2018
- Published by Taylor & Francis in Journal of Pain Research
- Vol. ume 11, 1147-1162
Open AccessOvine model of neuropathic pain for assessing mechanisms of spinal cord stimulation therapy via dorsal horn recordings, von Frey filaments, and gait analysis
Background: It is becoming increasingly important to understand the mechanisms of spinal cord stimulation (SCS) in alleviating neuropathic pain as novel stimulation paradigms arise. Purpose: Additionally, the small anatomic scale of current SCS animal models is a barrier to more translational research. Methods: Using chronic constriction injury (CCI) of the common peroneal nerve (CPN) in sheep (ovine), we have created a chronic model of neuropathic pain that avoids motor deficits present in prior large animal models. This large animal model has allowed us to implant clinical grade SCS hardware, which enables both acute and chronic testing using von Frey filament thresholds and gait analysis. Furthermore, the larger anatomic scale of the sheep allows for simultaneous single-unit recordings from the dorsal horn and SCS with minimal electrical artifact. Results: Detectable tactile hypersensitivity occurred 21 days after nerve injury, with preliminary indications that chronic SCS may reverse it in the painful limb. Gait analysis revealed no hoof drop in the CCI model. Single neurons were identified and discriminated in the dorsal horn, and their activity was modulated via SCS. Unlike previous large animal models that employed a complete transection of the nerve, no motor deficit was observed in the sheep with CCI. Conclusion: To our knowledge, this is the first reported large animal model of chronic neuropathic pain which facilitates the study of both acute and chronic SCS using complementary behavioral and electrophysiologic measures. As demonstrated by our successful establishment of these techniques, an ovine model of neuropathic pain is suitable for testing the mechanisms of SCS.
- 19 January 2016
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 40 (3) , 72-79
Treadmill measures of ambulation rates in ovine models of spinal cord injury and neuropathic pain
Our laboratories are developing treadmill-based gait analysis employing sheep to investigate potential efficacy of intra-dural spinal cord stimulation in the treatment of spinal cord injury and neuropathic pain. As part of efforts to establish the performance characteristics of the experimental arrangement, this study measured the treadmill speed via a tachometer, video belt-marker timing and ambulation-rate observations of the sheep. The data reveal a 0.1–0.3% residual drift in the baseline (unloaded) treadmill speed which increases with loading, but all three approaches agree on final speed to within 1.7%, at belt speeds of ≈4 km/h. Using the tachometer as the standard, the estimated upper limit on uncertainty in the video belt-marker approach is ± 0.18 km h−1 and the measured uncertainty is ± 0.15 km h−1. Employment of the latter method in determining timing differences between contralateral hoof strikes by the sheep suggests its utility in assessing severity of SCI and responses to therapeutic interventions.
- 19 January 2016
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 40 (3) , 72-79
Treadmill measures of ambulation rates in ovine models of spinal cord injury and neuropathic pain
Our laboratories are developing treadmill-based gait analysis employing sheep to investigate potential efficacy of intra-dural spinal cord stimulation in the treatment of spinal cord injury and neuropathic pain. As part of efforts to establish the performance characteristics of the experimental arrangement, this study measured the treadmill speed via a tachometer, video belt-marker timing and ambulation-rate observations of the sheep. The data reveal a 0.1–0.3% residual drift in the baseline (unloaded) treadmill speed which increases with loading, but all three approaches agree on final speed to within 1.7%, at belt speeds of ≈4 km/h. Using the tachometer as the standard, the estimated upper limit on uncertainty in the video belt-marker approach is ± 0.18 km h−1 and the measured uncertainty is ± 0.15 km h−1. Employment of the latter method in determining timing differences between contralateral hoof strikes by the sheep suggests its utility in assessing severity of SCI and responses to therapeutic interventions.
- 15 August 2012
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (1) , 27-36
Power and signal transmission protocol for a contactless subdural spinal cord stimulation device
Wireless signal transmission will play a critical role in developing reliable subdural spinal cord stimulation systems. We have developed an approach to inductively coupling signals across the epidural spacing between the pial and epidural surfaces. The major design constraints include tolerance of coil misalignments from spinal cord geometries in addition to reasonable power efficiencies within the expected range of movement. The design of the primary side as a driving circuit is simplified by several turns of commercial magnetic wire, whereas the implanted secondary side is implemented in a micro-planar spiral coil tuned to a resonant frequency of 1.6 MHz. We present the results of wireless inductive coupling experiments that demonstrate the ability to transmit and receive a frequency modulated 1.6 MHz carrier signal between primary and secondary coil antennae scaled to 10 mm. Power delivery is in the range of 400 mW at a link efficiency of 32 % for strong coupling (coil separations of 0.5 mm ) and in the range of 70 mW at 4 % efficiency for weak coupling (coil separations of 10 mm).
- 15 August 2012
- Published by Springer Nature in Biomedical Microdevices
- Vol. 15 (1) , 27-36
Power and signal transmission protocol for a contactless subdural spinal cord stimulation device
Wireless signal transmission will play a critical role in developing reliable subdural spinal cord stimulation systems. We have developed an approach to inductively coupling signals across the epidural spacing between the pial and epidural surfaces. The major design constraints include tolerance of coil misalignments from spinal cord geometries in addition to reasonable power efficiencies within the expected range of movement. The design of the primary side as a driving circuit is simplified by several turns of commercial magnetic wire, whereas the implanted secondary side is implemented in a micro-planar spiral coil tuned to a resonant frequency of 1.6 MHz. We present the results of wireless inductive coupling experiments that demonstrate the ability to transmit and receive a frequency modulated 1.6 MHz carrier signal between primary and secondary coil antennae scaled to 10 mm. Power delivery is in the range of 400 mW at a link efficiency of 32 % for strong coupling (coil separations of 0.5 mm ) and in the range of 70 mW at 4 % efficiency for weak coupling (coil separations of 10 mm).
- Open Access
- 1 October 2010
- Published by Pleiades Publishing Ltd in Gravitation and Cosmology
- Vol. 16 (4) , 251-258
Momentum of electromagnetic fields, speed of light in moving media, and the photon mass
In both the equations for matter and light wave propagation, the momentum of the electromagnetic fields P e reflects the relevant electromagnetic interaction. As a review of possible applications of wave propagation properties in the scenarios of standard and stochastic electrodynamics, some relevant experiments are described. Moreover, P e is also the link to the unitary vision of the quantum effects of the Aharonov-Bohm (AB) type, which provide a useful quantum approach for the limit of the photon mass m ph . A bench-top experiment based on effects of the AB type that exploit new interferometric techniques, is foreseen to yield the limit m ph ≃ 10−54 g, a value that improves upon the results achieved with other approaches.
- 1 October 2010
- Published by Pleiades Publishing Ltd in Gravitation and Cosmology
- Vol. 16 (4) , 251-258
Open AccessMomentum of electromagnetic fields, speed of light in moving media, and the photon mass
In both the equations for matter and light wave propagation, the momentum of the electromagnetic fields P e reflects the relevant electromagnetic interaction. As a review of possible applications of wave propagation properties in the scenarios of standard and stochastic electrodynamics, some relevant experiments are described. Moreover, P e is also the link to the unitary vision of the quantum effects of the Aharonov-Bohm (AB) type, which provide a useful quantum approach for the limit of the photon mass m ph . A bench-top experiment based on effects of the AB type that exploit new interferometric techniques, is foreseen to yield the limit m ph ≃ 10−54 g, a value that improves upon the results achieved with other approaches.
- 1 January 2006
- Published by Elsevier
Contributors
- 17 September 2004
- Published by IOP Publishing in Metrologia
- Vol. 41 (5) , S159-S170
Physical implications of Coulomb's Law
- 17 September 2004
- Published by IOP Publishing in Metrologia
- Vol. 41 (5) , S159-S170
Physical implications of Coulomb's Law
- 1 January 2002
- Published by Springer Nature
- p. 103-121
Experimental Perspectives on the Interplay between Quantum and Gravity Physics
- 1 January 2002
- Published by Springer Nature
- p. 103-121
Experimental Perspectives on the Interplay between Quantum and Gravity Physics
- 1 January 1995
- Published by Wiley in Journal of Image Guided Surgery
- Vol. 1 (6) , 295-299
Review of magnetic neorosurgery research
Image guided surgical techniques are often used to provide useful localizing information during the course of otherwise "standard" surgical procedures. In this review, a magnetic surgery system (MSS) is described that couples image guidance methods with a novel magnetic treatment delivery system. The MSS was designed with the unique capacity to manipulate an implant remotely, to follow complex curvilinear paths, and to implement serial movements over time without reoperation. Magnetically tipped intracerebral implants are placed on the brain surface and then directed along a target trajectory by means of externally generated magnetic gradients. The location of the implant is calculated by comparing preoperative magnetic resonance imaging (MRI) imaging data with intraoperative biplanar fluoroscopic images. A command computer presents the surgeon with relevant MRI-derived images and implements movement commands by sending currents of various strength to the six superconducting magnets suspended about the subject's head. The results of multidisciplinary preclinical research and development work are reviewed.
- 1 January 1995
- Published by Wiley in Journal of Image Guided Surgery
- Vol. 1 (6) , 295-299
Review of magnetic neorosurgery research
Image guided surgical techniques are often used to provide useful localizing information during the course of otherwise "standard" surgical procedures. In this review, a magnetic surgery system (MSS) is described that couples image guidance methods with a novel magnetic treatment delivery system. The MSS was designed with the unique capacity to manipulate an implant remotely, to follow complex curvilinear paths, and to implement serial movements over time without reoperation. Magnetically tipped intracerebral implants are placed on the brain surface and then directed along a target trajectory by means of externally generated magnetic gradients. The location of the implant is calculated by comparing preoperative magnetic resonance imaging (MRI) imaging data with intraoperative biplanar fluoroscopic images. A command computer presents the surgeon with relevant MRI-derived images and implements movement commands by sending currents of various strength to the six superconducting magnets suspended about the subject's head. The results of multidisciplinary preclinical research and development work are reviewed.