Chenwei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chenwei Wu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Jianyang Xue
Xi’an University of Architecture & Technology
13 shared publicationsDejun Song
Xi’an University of Architecture & Technology
10 shared publicationsFuyu Bai
Xi’an University of Architecture & Technology
7 shared publications- Jianyang Xue
School of Civil Engineering, Xi’an University of Architecture & Technology, Xi’an 710055, China
6 shared publications Fengliang Zhang
Shaanxi Institute of Architecture Science
3 shared publications- Hao Xue
School of Civil Engineering, Xi’an University of Architecture & Technology, Xi’an 710055, China
3 shared publications
Latest Publications
- 24 September 2026
- Published by Taylor & Francis in Journal of Earthquake Engineering
- p. 1-28
Experimental Analysis on Seismic Performance and Damage Assessment of Loose Through-Tenon Joints
1. The through-tenon joint, a traditional timber connection widely used in historic wooden structures, connects timber columns to horizontal components (e.g. tie beams, the Taojian beams, and roof ...
- 24 September 2026
- Published by Taylor & Francis in Journal of Earthquake Engineering
- p. 1-28
Experimental Analysis on Seismic Performance and Damage Assessment of Loose Through-Tenon Joints
1. The through-tenon joint, a traditional timber connection widely used in historic wooden structures, connects timber columns to horizontal components (e.g. tie beams, the Taojian beams, and roof ...
- 23 September 2026
- Published by Taylor & Francis in Journal of Earthquake Engineering
- p. 1-33
Seismic Performance Experiment and Deformation Damage Assessment of Full-Scale Loose Dovetail-Tenon Joints
- 23 September 2026
- Published by Taylor & Francis in Journal of Earthquake Engineering
- p. 1-33
Seismic Performance Experiment and Deformation Damage Assessment of Full-Scale Loose Dovetail-Tenon Joints
- Open Access
Experimental and Finite Element Investigation of Bond Strength of Earthen Mortar–Brick Interfaces in Historic Masonry Structures
This study aims to investigate the bond behavior at earthen mortar–brick interfaces in historic masonry structures. To that end, a series of combined compression–shear tests were conducted to systematically assess the influence of varying water–soil ratios and applied lateral compression on interfacial bond behavior. A fully decoupled microscopic finite element (FE) framework employing cohesive elements was developed to simulate the bond strength of earthen mortar–brick interfaces and validated using Spearman correlation analysis. The results indicate that increasing lateral compression markedly enhances both the peak displacement and shear strength, although it also reduces inter-specimen correlation by 18%. Notably, even under high lateral compression, the finite element predictions maintained a strong correlation with experimental data (R = 0.86), with a maximum deviation of less than 5%, demonstrating the model’s capability to accurately simulate the bond behavior of loess earthen mortar in masonry. These findings provide essential data and a robust computational framework for the preventive conservation of historic masonry structures.
Open AccessExperimental and Finite Element Investigation of Bond Strength of Earthen Mortar–Brick Interfaces in Historic Masonry Structures
This study aims to investigate the bond behavior at earthen mortar–brick interfaces in historic masonry structures. To that end, a series of combined compression–shear tests were conducted to systematically assess the influence of varying water–soil ratios and applied lateral compression on interfacial bond behavior. A fully decoupled microscopic finite element (FE) framework employing cohesive elements was developed to simulate the bond strength of earthen mortar–brick interfaces and validated using Spearman correlation analysis. The results indicate that increasing lateral compression markedly enhances both the peak displacement and shear strength, although it also reduces inter-specimen correlation by 18%. Notably, even under high lateral compression, the finite element predictions maintained a strong correlation with experimental data (R = 0.86), with a maximum deviation of less than 5%, demonstrating the model’s capability to accurately simulate the bond behavior of loess earthen mortar in masonry. These findings provide essential data and a robust computational framework for the preventive conservation of historic masonry structures.
- 16 February 2025
- Published by Elsevier in Structures
- Vol. 73
Seismic performance assessment of heritage timber-frame structure with a single circle of pillars and double pyramidal roofs
- 16 February 2025
- Published by Elsevier in Structures
- Vol. 73
Seismic performance assessment of heritage timber-frame structure with a single circle of pillars and double pyramidal roofs
- 7 February 2025
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 34 (2)
In Situ Dynamic Characteristic Test and Seismic Performance Analysis of Hybrid Brick‐Concrete and Timber Structure of Historic and Cultural Architectures
In order to study the dynamic characteristics and seismic performance of the hybrid brick‐concrete and timber (HBCT) structure, an in situ dynamic characteristic test was carried out, and peak picking method was used to calculate natural frequencies, damping ratios, and vibration modes. Considering semi‐rigid mechanical characteristics, a finite element model of the hybrid structure was established, and the calculation results agreed well with the test results. Kobe, El Centro and an artificial ground motion were input for displacement and acceleration response analysis. A set of fifteen ground motion records were selected, and incremental dynamic analysis and seismic fragility analysis were conducted. Results show that the first and second natural frequencies of the HBCT structure are 4.327 and 4.375 Hz, and the vibration modes are translation in the east–west direction and in the north–south direction, respectively. Taking the Kobe ground motion as an example, the maximum displacement of the pillar top of the second‐floor timber structure is 6.12 times that of the pillar top of the first‐floor brick‐concrete structure. The peak inter‐structural layer drift of 1/155 is less than the standard limit. Dynamic coefficients of the overall structure are less than 1, which indicates that the HBCT structure exhibits good shock absorption performance. The performance at different seismic intensities is in accordance with the “Three‐level and Two‐stage Seismic Fortification Goals,” which means no damage under minor earthquake, repairable damage under moderate earthquake, and no collapse under large earthquake.
- 7 February 2025
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 34 (2)
In Situ Dynamic Characteristic Test and Seismic Performance Analysis of Hybrid Brick‐Concrete and Timber Structure of Historic and Cultural Architectures
In order to study the dynamic characteristics and seismic performance of the hybrid brick‐concrete and timber (HBCT) structure, an in situ dynamic characteristic test was carried out, and peak picking method was used to calculate natural frequencies, damping ratios, and vibration modes. Considering semi‐rigid mechanical characteristics, a finite element model of the hybrid structure was established, and the calculation results agreed well with the test results. Kobe, El Centro and an artificial ground motion were input for displacement and acceleration response analysis. A set of fifteen ground motion records were selected, and incremental dynamic analysis and seismic fragility analysis were conducted. Results show that the first and second natural frequencies of the HBCT structure are 4.327 and 4.375 Hz, and the vibration modes are translation in the east–west direction and in the north–south direction, respectively. Taking the Kobe ground motion as an example, the maximum displacement of the pillar top of the second‐floor timber structure is 6.12 times that of the pillar top of the first‐floor brick‐concrete structure. The peak inter‐structural layer drift of 1/155 is less than the standard limit. Dynamic coefficients of the overall structure are less than 1, which indicates that the HBCT structure exhibits good shock absorption performance. The performance at different seismic intensities is in accordance with the “Three‐level and Two‐stage Seismic Fortification Goals,” which means no damage under minor earthquake, repairable damage under moderate earthquake, and no collapse under large earthquake.
- Open Access
Dynamic Characteristics and Seismic Response of Multi-Story Wooden Tower Considering the Influence of a High Stylobate
In situ dynamic tests were conducted on Caiyunjian Tower to investigate the influence of a high stylobate on its dynamic characteristics and seismic response through time–domain and frequency–domain methods. Finite element models were developed for Caiyunjian Tower (wooden structure and platform) and the overall structure including the high stylobate. Subsequently, models were subjected to El Centro, Taft, and Lanzhou waves at varying amplitudes. The seismic response results indicate that the overall structure model exhibits a low natural vibration frequency with closely spaced modal frequencies. As the peak seismic wave acceleration increases, both models exhibit increased acceleration, displacement, and shear responses. The Caiyunjian Tower model shows greater sensitivity to the El Centro wave, whereas the overall structure model is more responsive to the Taft wave. Under seismic waves with identical peak acceleration, the overall structure model exhibits greater dynamic responses than the Caiyunjian Tower model. The high stylobate minimally affects the lower-order frequencies of the upper structure but significantly influences the higher-order frequencies. Therefore, the high stylobate has an adverse influence on the seismic behavior of Caiyunjian Tower.
Open AccessDynamic Characteristics and Seismic Response of Multi-Story Wooden Tower Considering the Influence of a High Stylobate
In situ dynamic tests were conducted on Caiyunjian Tower to investigate the influence of a high stylobate on its dynamic characteristics and seismic response through time–domain and frequency–domain methods. Finite element models were developed for Caiyunjian Tower (wooden structure and platform) and the overall structure including the high stylobate. Subsequently, models were subjected to El Centro, Taft, and Lanzhou waves at varying amplitudes. The seismic response results indicate that the overall structure model exhibits a low natural vibration frequency with closely spaced modal frequencies. As the peak seismic wave acceleration increases, both models exhibit increased acceleration, displacement, and shear responses. The Caiyunjian Tower model shows greater sensitivity to the El Centro wave, whereas the overall structure model is more responsive to the Taft wave. Under seismic waves with identical peak acceleration, the overall structure model exhibits greater dynamic responses than the Caiyunjian Tower model. The high stylobate minimally affects the lower-order frequencies of the upper structure but significantly influences the higher-order frequencies. Therefore, the high stylobate has an adverse influence on the seismic behavior of Caiyunjian Tower.
- Open Access
Analysis of Dynamic Characteristics and Seismic Response of Chen Xiang Pavilion in Xi’an Considering the Lower Stylobate
This paper presents the dynamic characteristics and seismic performance of the Chen Xiang Pavilion in Xi’an and the influence of the lower stylobate on the dynamic response of the upper wooden structure. An in situ dynamic test was conducted under ambient vibration to detect the natural frequencies and vibration modes of the structure. Three numerical models, including the upper wooden structure, the lower stylobate, and the whole structure (wooden structure and stylobate), were established. Dynamic characteristic and seismic response analyses were performed on the calculated models to investigate the influence of the lower stylobate on the dynamic response of the upper wooden structure. The simulation results indicated that the lower stylobate significantly affected the dynamic characteristics of the upper wooden structure above the third order. The seismic responses of the upper wooden structure were amplified because of the lower stylobate. Under different excitations, the displacement response of the whole structure was up to 1.99 times relative to the upper wooden structure, and the structural shear forces were increased by 15.3%. The dynamic amplification coefficient was magnified from 0.742~0.948 to 1.024~1.776. The Chen Xiang Pavilion has a good energy dissipation capacity, but the lower stylobate is unfavorable for its earthquake resistance.
Open AccessAnalysis of Dynamic Characteristics and Seismic Response of Chen Xiang Pavilion in Xi’an Considering the Lower Stylobate
This paper presents the dynamic characteristics and seismic performance of the Chen Xiang Pavilion in Xi’an and the influence of the lower stylobate on the dynamic response of the upper wooden structure. An in situ dynamic test was conducted under ambient vibration to detect the natural frequencies and vibration modes of the structure. Three numerical models, including the upper wooden structure, the lower stylobate, and the whole structure (wooden structure and stylobate), were established. Dynamic characteristic and seismic response analyses were performed on the calculated models to investigate the influence of the lower stylobate on the dynamic response of the upper wooden structure. The simulation results indicated that the lower stylobate significantly affected the dynamic characteristics of the upper wooden structure above the third order. The seismic responses of the upper wooden structure were amplified because of the lower stylobate. Under different excitations, the displacement response of the whole structure was up to 1.99 times relative to the upper wooden structure, and the structural shear forces were increased by 15.3%. The dynamic amplification coefficient was magnified from 0.742~0.948 to 1.024~1.776. The Chen Xiang Pavilion has a good energy dissipation capacity, but the lower stylobate is unfavorable for its earthquake resistance.
- 26 May 2023
- Published by Elsevier in Structures
- Vol. 54, 541-555
Experimental study on seismic performance and deformation damage of loose dovetail-tenon joints in ancient timber structures
- 26 May 2023
- Published by Elsevier in Structures
- Vol. 54, 541-555
Experimental study on seismic performance and deformation damage of loose dovetail-tenon joints in ancient timber structures
- 30 January 2023
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 18 (4) , 526-550
Experimental and Numerical Study on the Mechanical Performance of Dou-Gong Bracket at the Corner under Vertical Load
This paper is focused on the mechanical performance of the Dou-Gong bracket at the corner under vertical load. A full-scaled specimen was tested under the static compressive load. The load-displacement curves, load distribution law and displacement of components were discussed. A finite element model was established and validated with test results. The deformation and stress of the whole Dou-Gong bracket and main components were analyzed, and the influence of the wood properties and friction coefficients was studied. The results show that there are four stages in the load-displacement curve and the plastic stiffness is 76.36% lower than that in the elastic stage. The components in the oblique 45° direction mainly transfer the force, while the load distribution ratios in the width and oblique 45° directions of the lower layer is closer to 1. The displacements of the components in oblique 45° direction in the No. 2 and No. 3 layers are smaller than those of the components in width direction. With the increase of the compressive strength, the elastic moduli in the radial direction and the friction coefficients, the stiffness in the plastic stage increases and the maximum displacement decreases. However, the compressive strength and the elastic moduli in the longitudinal direction have little effect on the load-displacement curves.
- 30 January 2023
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 18 (4) , 526-550
Experimental and Numerical Study on the Mechanical Performance of Dou-Gong Bracket at the Corner under Vertical Load
This paper is focused on the mechanical performance of the Dou-Gong bracket at the corner under vertical load. A full-scaled specimen was tested under the static compressive load. The load-displacement curves, load distribution law and displacement of components were discussed. A finite element model was established and validated with test results. The deformation and stress of the whole Dou-Gong bracket and main components were analyzed, and the influence of the wood properties and friction coefficients was studied. The results show that there are four stages in the load-displacement curve and the plastic stiffness is 76.36% lower than that in the elastic stage. The components in the oblique 45° direction mainly transfer the force, while the load distribution ratios in the width and oblique 45° directions of the lower layer is closer to 1. The displacements of the components in oblique 45° direction in the No. 2 and No. 3 layers are smaller than those of the components in width direction. With the increase of the compressive strength, the elastic moduli in the radial direction and the friction coefficients, the stiffness in the plastic stage increases and the maximum displacement decreases. However, the compressive strength and the elastic moduli in the longitudinal direction have little effect on the load-displacement curves.