Benniu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Benniu Zhang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Haonan Xia
2 shared publicationsJianhui Jiang
Xinjiang Communications Construction Group Co
2 shared publications- Jigang Yu
Chongqing Jiaotong University
2 shared publications - Jinglin Pan
Chongqing Jiaotong University, Chongqing, China
2 shared publications Qiang Yin
Xinjiang Communications Construction Group Co
2 shared publicationsXiaodong Wu
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 25
Mechanism-based numerical investigation of temperature- and corrosion-related local distresses in a long-span PC box-girder bridge: A case study
- 2 November 2026
- Published by Elsevier in Case Studies in Construction Materials
- Vol. 25
Open AccessMechanism-based numerical investigation of temperature- and corrosion-related local distresses in a long-span PC box-girder bridge: A case study
- Open Access
- 16 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17
High-accuracy fatigue life prediction and early fracture warning for ferromagnetic metals via spin correlation amplification
Sudden fatigue failure of metallic structures triggers thousands of safety accidents annually, causing tens of thousands of casualties and economic losses approaching $100 billion. Traditional detection techniques face challenges in capturing early fatigue damage features like subnanometer atomic displacements and localized metal bond ruptures. Based on the synchronized weakening mechanism between binding forces and exchange interactions during fatigue processes in ferromagnetic metals, this study obtained high-sensitivity fatigue observations by exciting the quantum spin correlation amplification effect via an external magnetic field. We conducted fatigue tests on 193 ferromagnetic metal samples over 3700 cumulative hours, establishing a mapping relationship between fatigue-induced magnetic flux changes and the degree of binding force weakening. This work integrated macroscopic fatigue life prediction with ferromagnetic material microstructural parameters, achieving a prediction accuracy with R2 > 0.9 and providing a reliable prefracture warning, potentially mitigating fatigue fractures in large-scale engineering structures and reducing the associated economic losses.
- 16 March 2026
- Published by Springer Nature in Nature Communications
- Vol. 17
Open AccessHigh-accuracy fatigue life prediction and early fracture warning for ferromagnetic metals via spin correlation amplification
Sudden fatigue failure of metallic structures triggers thousands of safety accidents annually, causing tens of thousands of casualties and economic losses approaching $100 billion. Traditional detection techniques face challenges in capturing early fatigue damage features like subnanometer atomic displacements and localized metal bond ruptures. Based on the synchronized weakening mechanism between binding forces and exchange interactions during fatigue processes in ferromagnetic metals, this study obtained high-sensitivity fatigue observations by exciting the quantum spin correlation amplification effect via an external magnetic field. We conducted fatigue tests on 193 ferromagnetic metal samples over 3700 cumulative hours, establishing a mapping relationship between fatigue-induced magnetic flux changes and the degree of binding force weakening. This work integrated macroscopic fatigue life prediction with ferromagnetic material microstructural parameters, achieving a prediction accuracy with R2 > 0.9 and providing a reliable prefracture warning, potentially mitigating fatigue fractures in large-scale engineering structures and reducing the associated economic losses.
- 29 July 2025
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 28 (15) , 2855-2870
Analysis of temperature response in concrete box-girder bridges based on steel reinforcement thermal conductivity model
In the thermal analysis of concrete box girder bridges, the high thermal conductivity of steel bars is often oversimplified, leading to deviations in temperature field prediction results. At high temperatures, the thermal conductivity of steel significantly alters the temperature gradient distribution within the section, thereby affecting thermal stress and the resistance to cracking. The box girder is widely used in long-span bridges due to its excellent torsional stiffness and economic benefits. However, the complex temperature field may cause cracking, warping, and durability problems. The significant thermal conductivity difference between steel and concrete will produce a localized temperature gradient in the area with dense reinforcement (which will induce thermal stress concentration and endanger the stability of the structure). Existing studies often overlook the thermal conductivity of steel bars, assuming a purely thermal conductivity process, which deviates from the actual situation. This study combines theoretical analysis, refined finite element modeling, parametric research (reinforcement diameter and stirrup spacing), and related stress analysis to propose the thermal siphon effect. The study shows that increasing the reinforcement diameter from 16 mm to 26 mm can significantly reduce the homogenization time of the structural temperature. When the stirrup spacing along the heat conduction direction is reduced from 170 mm to 30 mm, the reinforcement is dense, and the diameter is large. The structure can reach thermal equilibrium faster, and the temperature gradient is smaller. The temperature gradient causes the surface concrete to be under tension and the internal concrete to be under pressure, which may lead to surface cracking. In areas with dense reinforcement, accelerated heat transfer results in a significant increase in temperature, which can induce local stress concentration.
- 29 July 2025
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 28 (15) , 2855-2870
Analysis of temperature response in concrete box-girder bridges based on steel reinforcement thermal conductivity model
In the thermal analysis of concrete box girder bridges, the high thermal conductivity of steel bars is often oversimplified, leading to deviations in temperature field prediction results. At high temperatures, the thermal conductivity of steel significantly alters the temperature gradient distribution within the section, thereby affecting thermal stress and the resistance to cracking. The box girder is widely used in long-span bridges due to its excellent torsional stiffness and economic benefits. However, the complex temperature field may cause cracking, warping, and durability problems. The significant thermal conductivity difference between steel and concrete will produce a localized temperature gradient in the area with dense reinforcement (which will induce thermal stress concentration and endanger the stability of the structure). Existing studies often overlook the thermal conductivity of steel bars, assuming a purely thermal conductivity process, which deviates from the actual situation. This study combines theoretical analysis, refined finite element modeling, parametric research (reinforcement diameter and stirrup spacing), and related stress analysis to propose the thermal siphon effect. The study shows that increasing the reinforcement diameter from 16 mm to 26 mm can significantly reduce the homogenization time of the structural temperature. When the stirrup spacing along the heat conduction direction is reduced from 170 mm to 30 mm, the reinforcement is dense, and the diameter is large. The structure can reach thermal equilibrium faster, and the temperature gradient is smaller. The temperature gradient causes the surface concrete to be under tension and the internal concrete to be under pressure, which may lead to surface cracking. In areas with dense reinforcement, accelerated heat transfer results in a significant increase in temperature, which can induce local stress concentration.
- Open Access
- 14 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Study on the Main Factors of Frequency Variation of LC Resonant Prestress Detection Method
Stress loss of prestressed steel strands of existing bridges influences their bearing capacity, so it is of great significance to realize the stress detection. A steel strand that has an inductive property is designed into the resonant circuit, which can realize the stress measurement of the steel strands by testing the resonant frequency. This method is a promising approach for the stress detection of the steel strands. Previous research found that structural stress made the permeability of steel strands change due to the influence of magnetoelastic effect. In the process, the length of steel strands is also changed. Therefore, further research needs to be done to verify the main influence parameter affecting the resonant frequency of the circuit. Furthermore, it is very important to know how the stress affects the resonant frequency to realize the detection of the prestressed force of the steel strands. Therefore, in this paper, the relationship between stress and relative permeability and length is analyzed theoretically, and the theory of stress frequency of steel strands is modified and verified by experiments. The stress‐frequency experiments of steel strands and aluminum strands with great difference in relative permeability are carried out. Experiments on stress frequencies of 7‐Ф15.20 mm steel strands with different lengths are carried out. The influence of length and permeability parameters on resonance frequency is analyzed. The experimental results show that under the same conditions, the resonant frequencies of steel strands and aluminum strands are almost the same on LC electric circuits, and the resonant frequency decreases linearly with the increase of the natural length of the component and increases linearly with the increase of stress. Consequently, compared with the influence of length change on LC electromagnetic resonance frequency, the relative permeability of the stress change component can be ignored. The stress changes the resonant frequency mainly by changing the length of the strands.
- 14 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Open AccessStudy on the Main Factors of Frequency Variation of LC Resonant Prestress Detection Method
Stress loss of prestressed steel strands of existing bridges influences their bearing capacity, so it is of great significance to realize the stress detection. A steel strand that has an inductive property is designed into the resonant circuit, which can realize the stress measurement of the steel strands by testing the resonant frequency. This method is a promising approach for the stress detection of the steel strands. Previous research found that structural stress made the permeability of steel strands change due to the influence of magnetoelastic effect. In the process, the length of steel strands is also changed. Therefore, further research needs to be done to verify the main influence parameter affecting the resonant frequency of the circuit. Furthermore, it is very important to know how the stress affects the resonant frequency to realize the detection of the prestressed force of the steel strands. Therefore, in this paper, the relationship between stress and relative permeability and length is analyzed theoretically, and the theory of stress frequency of steel strands is modified and verified by experiments. The stress‐frequency experiments of steel strands and aluminum strands with great difference in relative permeability are carried out. Experiments on stress frequencies of 7‐Ф15.20 mm steel strands with different lengths are carried out. The influence of length and permeability parameters on resonance frequency is analyzed. The experimental results show that under the same conditions, the resonant frequencies of steel strands and aluminum strands are almost the same on LC electric circuits, and the resonant frequency decreases linearly with the increase of the natural length of the component and increases linearly with the increase of stress. Consequently, compared with the influence of length change on LC electromagnetic resonance frequency, the relative permeability of the stress change component can be ignored. The stress changes the resonant frequency mainly by changing the length of the strands.
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
A Corrosion Detection Method for Steel Strands Based on LC Electromagnetic Resonance
At present, prestress detection is a worldwide problem. Corrosion has an important impact on the accuracy of the stress detection results of prestressed tendons. Once the steel strands in service is corroded, stress corrosion will occur, which seriously affects the safe operation of the prestressed structure. Based on the LC electromagnetic resonance circuit to detect the prestressing force of steel strands, this research has been successfully applied to the detection of the corrosion rate of steel strands, which lays the foundation for the nondestructive detection of the healthy state of steel strands in the existing structure. In this study, the steel strands were regarded as an external inductor embedded in the LC resonance circuit. After the steel strands was corroded, its electromagnetic characteristics would change, and this change was manifested by the resonance frequency. In this paper, the regular change of the resonance frequency caused by the change of the inductance of the steel wire after corrosion was explained theoretically, and a theoretical model of the relationship between the electromagnetic resonance frequency and the corrosion rate was established. In this study, it was proved through experiments that the LC electromagnetic resonance method can accurately detect the overall corrosion degree of bare steel stranded wires, and a fitting formula for corrosion detection of steel stranded wires was established. Through the analysis and exploration of the test data and test phenomena, it has been found that the action mechanism of the stranded wire decreases with the increase of the corrosion rate and the inductance thereof, which leads to the increase of the resonance frequency. The discovery of these laws will provide an improved basis for the prestress detection of in‐service steel strands by LC resonant circuits and make the method to be further applied to practical engineering.
- 1 January 2020
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2020 (1)
Open AccessA Corrosion Detection Method for Steel Strands Based on LC Electromagnetic Resonance
At present, prestress detection is a worldwide problem. Corrosion has an important impact on the accuracy of the stress detection results of prestressed tendons. Once the steel strands in service is corroded, stress corrosion will occur, which seriously affects the safe operation of the prestressed structure. Based on the LC electromagnetic resonance circuit to detect the prestressing force of steel strands, this research has been successfully applied to the detection of the corrosion rate of steel strands, which lays the foundation for the nondestructive detection of the healthy state of steel strands in the existing structure. In this study, the steel strands were regarded as an external inductor embedded in the LC resonance circuit. After the steel strands was corroded, its electromagnetic characteristics would change, and this change was manifested by the resonance frequency. In this paper, the regular change of the resonance frequency caused by the change of the inductance of the steel wire after corrosion was explained theoretically, and a theoretical model of the relationship between the electromagnetic resonance frequency and the corrosion rate was established. In this study, it was proved through experiments that the LC electromagnetic resonance method can accurately detect the overall corrosion degree of bare steel stranded wires, and a fitting formula for corrosion detection of steel stranded wires was established. Through the analysis and exploration of the test data and test phenomena, it has been found that the action mechanism of the stranded wire decreases with the increase of the corrosion rate and the inductance thereof, which leads to the increase of the resonance frequency. The discovery of these laws will provide an improved basis for the prestress detection of in‐service steel strands by LC resonant circuits and make the method to be further applied to practical engineering.
- Open Access
Length Effect on the Stress Detection of Prestressed Steel Strands Based on Electromagnetic Oscillation Method
Prestress detection of structures has been puzzling structural engineers for a long time. The inductance–capacitance (LC) electromagnetic oscillation method has shown a potential solution to this problem. It connects the two ends of a steel strand, which is simulated as an inductor, to the oscillation circuit, and the stress of the steel strand can be calculated by measuring the oscillation frequency of the circuit through a frequency meter. In the previous studies, the authors found that stress-frequency relation of 1.2 m steel strand was negatively correlated, while the stress-frequency of 10 m steel strand was positively correlated. To verify this conflict, two kinds of electrical inductance models of steel strands were established to fit the lengths. With the models, the stress-frequency relations of steel strands with different lengths were analyzed. After that, two kinds of experimental platforms were set up, and a series of stress-frequency relationship tests were carried out with 1.2 m, 5 m, 10 m and 15 m steel strands. Theoretical analysis and experimental results show that when the length is less than 2.013 m, the stress and oscillation frequencies are negatively correlated; when length is more than 2.199 m, the stress and oscillation frequencies are positively correlated; while when length is between 2.013 m and 2.199 m, the stress-frequency relationship is in transit from negative correlation to positive correlation.
Open AccessLength Effect on the Stress Detection of Prestressed Steel Strands Based on Electromagnetic Oscillation Method
Prestress detection of structures has been puzzling structural engineers for a long time. The inductance–capacitance (LC) electromagnetic oscillation method has shown a potential solution to this problem. It connects the two ends of a steel strand, which is simulated as an inductor, to the oscillation circuit, and the stress of the steel strand can be calculated by measuring the oscillation frequency of the circuit through a frequency meter. In the previous studies, the authors found that stress-frequency relation of 1.2 m steel strand was negatively correlated, while the stress-frequency of 10 m steel strand was positively correlated. To verify this conflict, two kinds of electrical inductance models of steel strands were established to fit the lengths. With the models, the stress-frequency relations of steel strands with different lengths were analyzed. After that, two kinds of experimental platforms were set up, and a series of stress-frequency relationship tests were carried out with 1.2 m, 5 m, 10 m and 15 m steel strands. Theoretical analysis and experimental results show that when the length is less than 2.013 m, the stress and oscillation frequencies are negatively correlated; when length is more than 2.199 m, the stress and oscillation frequencies are positively correlated; while when length is between 2.013 m and 2.199 m, the stress-frequency relationship is in transit from negative correlation to positive correlation.