Jaime Flores-Estrada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaime Flores-Estrada has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Miriam Veronica Flores Merino
Experimental Chemistry Laboratory, Faculty of Chemistry, Universidad Autónoma del Estado de México, Toluca de Lerdo 50120, Mexico
8 shared publications - Ma. Victoria Domínguez-García
Facultad de Química, Universidad Autónoma del Estado de México, Toluca, México
4 shared publications - Abraham González-Ruíz
Instituto Nacional de Investigaciones Nucleares, Carretera la Marquesa S/N, Ocoyoacac, 52750, Estado de México, Mexico
2 shared publications - Clara Santos-Cuevas
Department of Radioactive Materials, Instituto Nacional de Investigaciones Nucleares, Ocoyoacac 52750, Mexico
2 shared publications - Helen Irais Sánchez Mendoza
Facultad de Medicina, Universidad Autónoma del Estado de México, Paseo Tollocan S/N, Toluca, Estado de México 50130, Mexico
2 shared publications - Rogelio José Scougall-Vilchis
Center for Research in Dental Sciences and Advanced Studies “Dr. Keisaburo Miyata”, School of Dentistry, Autonomous University of the State of Mexico (UAEMex), Toluca 50130, State of Mexico, Mexico
2 shared publications
Latest Publications
- 2 January 2024
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 74 (1) , 1-10
PAM-based hydrogels characterization as a potential biomaterial for mammography QC-phantoms development
- 2 January 2024
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 74 (1) , 1-10
PAM-based hydrogels characterization as a potential biomaterial for mammography QC-phantoms development
- 13 September 2023
- Published by Universidad Nacional Autonoma de Mexico in Revista Digital Universitaria
- Vol. 24 (5)
Heridas crónicas: retos y tratamientos
Vol. 24, núm. 5 septiembre-octubre 2023 Heridas crónicas: retos y tratamientos Miriam V. Flores-Merino mvfloresm@uaemex.mx ORCID: 0000-0003-0793-0940 Universidad Autónoma del Estado de México (UAEméx) Profesora investigadora de tiempo completo adscrita a la Facultad de Química de la Universidad Autónoma del Estado de México (UAEMéx), Licenciatura en Química Farmacéutica Biológica (UAEMex) con doctorado en ingeniería de […]
- 13 September 2023
- Published by Universidad Nacional Autonoma de Mexico in Revista Digital Universitaria
- Vol. 24 (5)
Heridas crónicas: retos y tratamientos
Vol. 24, núm. 5 septiembre-octubre 2023 Heridas crónicas: retos y tratamientos Miriam V. Flores-Merino mvfloresm@uaemex.mx ORCID: 0000-0003-0793-0940 Universidad Autónoma del Estado de México (UAEméx) Profesora investigadora de tiempo completo adscrita a la Facultad de Química de la Universidad Autónoma del Estado de México (UAEMéx), Licenciatura en Química Farmacéutica Biológica (UAEMex) con doctorado en ingeniería de […]
- 28 November 2022
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42 (4) , 041506
An evaluation of the present status of quality assurance program implementation in digital mammography facilities in a developing country
Quality assurance program (QAP) implementation in mammography is a key aspect to guarantee the acquisition of -quality images and, thus, an opportune diagnosis of breast cancer. A QAP involves planned and systematic actions, such as quality control (QC) tests that will produce consistently high-quality images, while considering low radiation exposure for stakeholders. Currently, there is poor evidence of the current QAP implementation status in developing countries, particularly in Latin America. In this work, 47 Mexican digital mammography facilities were evaluated in terms of their QAP implementation’s current status during the period October 2021 to April 2022. A survey of three key indicators of compliance/non-compliance with QAPs was carried out. Also, 17 QC test parameters were assessed in all mammography units according to an international framework. The Kruskal–Wallis test, McNemar test, and Spearman correlation were used to identify the significant correlation between the QC tests and QAP indicators. Statistical analysis showed a significant positive correlation between the QAP indicators and QC parameters that were evaluated, especially associated with an increase in image quality. Almost 90% of the facilities evaluated failed in some QAP indicators, and only 44.68% of the facilities had an updated and current QAP implemented. Successful QAP implementation directly impacted on the QC mammography test results, particularly in terms of image quality, thus conditioning a successful mammography acquisition chain. The results obtained in this work suggest that better regulations need to be implemented to guarantee QAP surveillance, which could mean an increase in opportune diagnosis and management of breast cancer, with improved radiological safety for patients and occupational exposure personnel.
- 28 November 2022
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 42 (4) , 041506
An evaluation of the present status of quality assurance program implementation in digital mammography facilities in a developing country
Quality assurance program (QAP) implementation in mammography is a key aspect to guarantee the acquisition of -quality images and, thus, an opportune diagnosis of breast cancer. A QAP involves planned and systematic actions, such as quality control (QC) tests that will produce consistently high-quality images, while considering low radiation exposure for stakeholders. Currently, there is poor evidence of the current QAP implementation status in developing countries, particularly in Latin America. In this work, 47 Mexican digital mammography facilities were evaluated in terms of their QAP implementation’s current status during the period October 2021 to April 2022. A survey of three key indicators of compliance/non-compliance with QAPs was carried out. Also, 17 QC test parameters were assessed in all mammography units according to an international framework. The Kruskal–Wallis test, McNemar test, and Spearman correlation were used to identify the significant correlation between the QC tests and QAP indicators. Statistical analysis showed a significant positive correlation between the QAP indicators and QC parameters that were evaluated, especially associated with an increase in image quality. Almost 90% of the facilities evaluated failed in some QAP indicators, and only 44.68% of the facilities had an updated and current QAP implemented. Successful QAP implementation directly impacted on the QC mammography test results, particularly in terms of image quality, thus conditioning a successful mammography acquisition chain. The results obtained in this work suggest that better regulations need to be implemented to guarantee QAP surveillance, which could mean an increase in opportune diagnosis and management of breast cancer, with improved radiological safety for patients and occupational exposure personnel.
- Open Access
- 4 April 2022
- Published by Dirección de Bienes Públicos del Conocimiento, Universidad Autonoma del Estado de Mexico in Revista Salud y Cuidado
- Vol. 1 (2) , 38-47
Revisión documental de las características y tipos de cubrebocas como barreras protectoras contra virus
Introducción: El cubrebocas, también conocido como mascarilla, se ha vuelto una de las medidas sanitarias más discutidas entre la población debido a la pandemia. La gran diversidad de opciones hace que la elección de un cubrebocas resulte una tarea difícil, más cuando la seguridad es la principal preocupación.Objetivo: Realizar una revisión de artículos científicos y de normatividades disponibles sobre las características de los cubrebocas.Métodogía: Se realizó una revisión de la literatura. Para este objetivo se utilizó la base de datos de Google Scholar en inglés con restricción de años de publicación en un intervalo entre 2006 a 2021, se incluyeron solamente artículos científicos de investigación o de revisión.Resultados: A pesar de la importancia actual que tiene este tema, son pocos los estudios que abordan y prueban la eficacia real de los cubrebocas, esto aunado a la gran diversidad de opciones que puede hacer que la elección de un cubrebocas resulte en una tarea complicada. En este trabajo se analizaron ocho artículos que cumplieron con los criterios de inclusión.Conclusión: Los materiales usados y el número de capas son factores importantes para la efectividad del cubrebocas. Entre otros factores también se encuentran el ajuste y uso adecuado, así como la carga viral en el medio ambiente.
- 4 April 2022
- Published by Dirección de Bienes Públicos del Conocimiento, Universidad Autonoma del Estado de Mexico in Revista Salud y Cuidado
- Vol. 1 (2) , 38-47
Open AccessRevisión documental de las características y tipos de cubrebocas como barreras protectoras contra virus
Introducción: El cubrebocas, también conocido como mascarilla, se ha vuelto una de las medidas sanitarias más discutidas entre la población debido a la pandemia. La gran diversidad de opciones hace que la elección de un cubrebocas resulte una tarea difícil, más cuando la seguridad es la principal preocupación.Objetivo: Realizar una revisión de artículos científicos y de normatividades disponibles sobre las características de los cubrebocas.Métodogía: Se realizó una revisión de la literatura. Para este objetivo se utilizó la base de datos de Google Scholar en inglés con restricción de años de publicación en un intervalo entre 2006 a 2021, se incluyeron solamente artículos científicos de investigación o de revisión.Resultados: A pesar de la importancia actual que tiene este tema, son pocos los estudios que abordan y prueban la eficacia real de los cubrebocas, esto aunado a la gran diversidad de opciones que puede hacer que la elección de un cubrebocas resulte en una tarea complicada. En este trabajo se analizaron ocho artículos que cumplieron con los criterios de inclusión.Conclusión: Los materiales usados y el número de capas son factores importantes para la efectividad del cubrebocas. Entre otros factores también se encuentran el ajuste y uso adecuado, así como la carga viral en el medio ambiente.
- 4 October 2020
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 71 (4) , 266-277
Design of a polyacrylamide and gelatin hydrogel as a synthetic extracellular matrix
Hydrogels are three-dimensional networks with high water content become soft and elastic mimicking some characteristics of the extracellular matrix. They can be prepared by using either synthetic or natural polymers, therefore, their combination can benefit the overall of the material for a specific biomedical application. In this study, a semi-interpenetrating polymer network hydrogel of polyacrylamide/gelatin (PAM/Gel) with up to 0.3% of gelatin content was synthesized while evidence of gelatin incorporation was obtained from FTIR and Raman spectroscopy. SEM micrographs show uniform porous structure of PAM/gelatin combined hydrogels. According to the micrographs, the amount of pores decrease with the incorporation of gelatin into the PAM network. The combined hydrogel had the maximum swelling at 37 °C (1,800 ± 73%). Results indicate that PAM/Gel hydrogels are biocompatible (fibroblast viability >70%) in the presence of extracts and by direct contact method. These hydrogels can be good candidates for soft tissue engineering applications. GRAPHICAL ABSTRACT
- 4 October 2020
- Published by Taylor & Francis in International Journal of Polymeric Materials and Polymeric Biomaterials
- Vol. 71 (4) , 266-277
Design of a polyacrylamide and gelatin hydrogel as a synthetic extracellular matrix
Hydrogels are three-dimensional networks with high water content become soft and elastic mimicking some characteristics of the extracellular matrix. They can be prepared by using either synthetic or natural polymers, therefore, their combination can benefit the overall of the material for a specific biomedical application. In this study, a semi-interpenetrating polymer network hydrogel of polyacrylamide/gelatin (PAM/Gel) with up to 0.3% of gelatin content was synthesized while evidence of gelatin incorporation was obtained from FTIR and Raman spectroscopy. SEM micrographs show uniform porous structure of PAM/gelatin combined hydrogels. According to the micrographs, the amount of pores decrease with the incorporation of gelatin into the PAM network. The combined hydrogel had the maximum swelling at 37 °C (1,800 ± 73%). Results indicate that PAM/Gel hydrogels are biocompatible (fibroblast viability >70%) in the presence of extracts and by direct contact method. These hydrogels can be good candidates for soft tissue engineering applications. GRAPHICAL ABSTRACT
- 25 May 2018
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 135 (34)
Characterization of ketoprofen‐loaded PEG‐CH semi‐IPN system for wound dressing application
Polymer systems, in the form of crosslinking networks, have been widely used in biomedicine. However, they are a challenge mainly due to the impact of their physicochemical properties on release kinetics of drugs. Ketoprofen is an analgesic anti‐inflammatory drug with short half‐life (2018, 135, 46644.
- 25 May 2018
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 135 (34)
Characterization of ketoprofen‐loaded PEG‐CH semi‐IPN system for wound dressing application
Polymer systems, in the form of crosslinking networks, have been widely used in biomedicine. However, they are a challenge mainly due to the impact of their physicochemical properties on release kinetics of drugs. Ketoprofen is an analgesic anti‐inflammatory drug with short half‐life (2018, 135, 46644.
- Open Access
- 13 December 2017
- Published by IntechOpen
Mechanical Stimulation of Cells Through Scaffold Design for Tissue Engineering
Tissue engineering scaffolds attempt to mimic the stem cell environment by creating different biophysical and chemical signals. On the other hand, stem cells are able to sense these characteristics and change their destiny. Scientists try to explain these phenomena through scaffold design and in vitro experiments, but the mechanisms implicated remain unclear. Moreover, environment-cell interactions are a key process to get organs and tissues arrangement. Therefore, this chapter deals with the mechanical signals and mechanism involved in cell behaviour through scaffolds as a strategy in tissue engineering.
- 13 December 2017
- Published by IntechOpen
Open AccessMechanical Stimulation of Cells Through Scaffold Design for Tissue Engineering
Tissue engineering scaffolds attempt to mimic the stem cell environment by creating different biophysical and chemical signals. On the other hand, stem cells are able to sense these characteristics and change their destiny. Scientists try to explain these phenomena through scaffold design and in vitro experiments, but the mechanisms implicated remain unclear. Moreover, environment-cell interactions are a key process to get organs and tissues arrangement. Therefore, this chapter deals with the mechanical signals and mechanism involved in cell behaviour through scaffolds as a strategy in tissue engineering.
- 17 October 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 27 (12) , 1-10
Hydrogels based on poly(ethylene glycol) as scaffolds for tissue engineering application: biocompatibility assessment and effect of the sterilization process
Hydrogels are suitable materials to promote cell proliferation and tissue support because of their hydrophilic nature, porous structure and sticky properties. However, hydrogel synthesis involves the addition of additives that can increase the risk of inducing cytotoxicity. Sterilization is a critical process for hydrogel clinical use as a proper scaffold for tissue engineering. In this study, poly(ethylene glycol) (PEG), poly(ethylene glycol)-chitosan (PEG-CH) and multi-arm PEG hydrogels were synthesized by free radical polymerization and sterilized by gamma irradiation or disinfected using 70 % ethanol. The biocompatibility assessment in human fibroblasts and hemocompatibility studies (hemolysis, platelet aggregation, morphology of mononuclear cells and viability) in peripheral blood from healthy volunteers (ex vivo), were performed. The sterilization or disinfection effect on hydrogel structures was evaluated by FT-IR spectroscopy. Results indicated that hydrogels do not induce any damage to fibroblasts, erythrocytes, platelets or mononuclear cells. Moreover, there was no significant difference in the biocompatibility after the sterilization or disinfection treatment. However, after gamma irradiation, several IR spectroscopic bands were shifted to higher or lower energies with different intensity in all hydrogels. In particular, several bands associated to carboxyl or hydroxyl groups were slightly shifted, possibly associated to scission reactions. The disinfection treatment (70 % ethanol) and γ-irradiation at 13.83 ± 0.7 kGy did not induce morphological damages and yielded sterile and biocompatible PEG hydrogels potentially useful for clinical applications.
- 17 October 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 27 (12) , 1-10
Hydrogels based on poly(ethylene glycol) as scaffolds for tissue engineering application: biocompatibility assessment and effect of the sterilization process
Hydrogels are suitable materials to promote cell proliferation and tissue support because of their hydrophilic nature, porous structure and sticky properties. However, hydrogel synthesis involves the addition of additives that can increase the risk of inducing cytotoxicity. Sterilization is a critical process for hydrogel clinical use as a proper scaffold for tissue engineering. In this study, poly(ethylene glycol) (PEG), poly(ethylene glycol)-chitosan (PEG-CH) and multi-arm PEG hydrogels were synthesized by free radical polymerization and sterilized by gamma irradiation or disinfected using 70 % ethanol. The biocompatibility assessment in human fibroblasts and hemocompatibility studies (hemolysis, platelet aggregation, morphology of mononuclear cells and viability) in peripheral blood from healthy volunteers (ex vivo), were performed. The sterilization or disinfection effect on hydrogel structures was evaluated by FT-IR spectroscopy. Results indicated that hydrogels do not induce any damage to fibroblasts, erythrocytes, platelets or mononuclear cells. Moreover, there was no significant difference in the biocompatibility after the sterilization or disinfection treatment. However, after gamma irradiation, several IR spectroscopic bands were shifted to higher or lower energies with different intensity in all hydrogels. In particular, several bands associated to carboxyl or hydroxyl groups were slightly shifted, possibly associated to scission reactions. The disinfection treatment (70 % ethanol) and γ-irradiation at 13.83 ± 0.7 kGy did not induce morphological damages and yielded sterile and biocompatible PEG hydrogels potentially useful for clinical applications.
- Open Access
- 5 February 2013
- Published by Wiley in Australian Dental Journal
- Vol. 58 (1) , 101-105
Adhesion of Streptococci to various orthodontic composite resins
Background: This investigation aimed to determine quantitatively the adhesion of Streptococcus mutans and Streptococcus sobrinus to orthodontic composite resins that were tested simultaneously using radio‐markers.Methods: Seven orthodontic composite resins were classified into seven groups: BeautyOrtho Bond (GI), Blugloo (GII), Enlight (GIII), Grengloo (GIV), Kurasper F (GV), Transbond CC (GVI) and Turbo Bond II (GVII). Thirty 4 x 4 x 1 mm blocks of each orthodontic composite resin were made (a total of 210 blocks). Both Streptococcus species were cultivated independently. For the quantitative analysis, radioactive markers were used to codify the bacteria (3H for Streptococcus mutans and 14C for Streptococcus sobrinus). The blocks were submerged in a solution with microorganisms previously radiolabelled for 2 hours at 37 °C in constant movement. The blocks were placed in a combustion system to quantify the Streptococcus adhering to the surface of the materials by capturing the residues and measuring the radiation.Results: Significant differences in bacterial adhesion were found among the groups. The lowest significant scores for both microorganisms were observed in GIII.Conclusions: The orthodontic composite resin evaluated in GIII exhibited the lowest adhesion of Streptococcus mutans and Streptococcus sobrinus, which may reduce enamel demineralization and the risk of white spot lesion formation.
- 5 February 2013
- Published by Wiley in Australian Dental Journal
- Vol. 58 (1) , 101-105
Open AccessAdhesion of Streptococci to various orthodontic composite resins
Background: This investigation aimed to determine quantitatively the adhesion of Streptococcus mutans and Streptococcus sobrinus to orthodontic composite resins that were tested simultaneously using radio‐markers.Methods: Seven orthodontic composite resins were classified into seven groups: BeautyOrtho Bond (GI), Blugloo (GII), Enlight (GIII), Grengloo (GIV), Kurasper F (GV), Transbond CC (GVI) and Turbo Bond II (GVII). Thirty 4 x 4 x 1 mm blocks of each orthodontic composite resin were made (a total of 210 blocks). Both Streptococcus species were cultivated independently. For the quantitative analysis, radioactive markers were used to codify the bacteria (3H for Streptococcus mutans and 14C for Streptococcus sobrinus). The blocks were submerged in a solution with microorganisms previously radiolabelled for 2 hours at 37 °C in constant movement. The blocks were placed in a combustion system to quantify the Streptococcus adhering to the surface of the materials by capturing the residues and measuring the radiation.Results: Significant differences in bacterial adhesion were found among the groups. The lowest significant scores for both microorganisms were observed in GIII.Conclusions: The orthodontic composite resin evaluated in GIII exhibited the lowest adhesion of Streptococcus mutans and Streptococcus sobrinus, which may reduce enamel demineralization and the risk of white spot lesion formation.
- Open Access
- 1 January 2013
- Published by Wiley in International Journal of Polymer Science
- Vol. 2013, 1-12
Polyurethane-Keratin Membranes: Structural Changes by Isocyanate and pH, and the Repercussion on Cr(VI) Removal
Keratin has the capacity to interact with metal ions. In order to take advantage of this potential, a novel membrane with polyurethane and keratin has been developed and studied for removal of Cr(VI) from aqueous solution. Physicochemical and morphological properties of these hybrid membranes were studied, varying synthesis parameters such as the type of isocyanate and pH in keratin solution. The effects of using diphenyl-methane-diisocyanate or toluene-diisocyanate and modifying the pH in keratin solutions were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy, and dynamical mechanical analysis. Results show that pH has a strong influence on morphology and on Cr(VI) removal efficiency. When pH in keratin solution is low (2.5), the protein separates from water, and a more closed cell in the membrane is obtained affecting its mechanical properties. The removal efficiency of Cr(VI) was also assessed at different pH values of chromium solutions. These results show that when pH of the Cr solution is acidic (at 1.5), the Cr(VI) removal percentages increase significantly, reaching up to a 58%. Thus this paper demonstrates the successful combination of synthetic and natural polymers depending on the process parameters to be applied in the critical purpose of remediation of Cr(VI) contamination.
- 1 January 2013
- Published by Wiley in International Journal of Polymer Science
- Vol. 2013, 1-12
Open AccessPolyurethane-Keratin Membranes: Structural Changes by Isocyanate and pH, and the Repercussion on Cr(VI) Removal
Keratin has the capacity to interact with metal ions. In order to take advantage of this potential, a novel membrane with polyurethane and keratin has been developed and studied for removal of Cr(VI) from aqueous solution. Physicochemical and morphological properties of these hybrid membranes were studied, varying synthesis parameters such as the type of isocyanate and pH in keratin solution. The effects of using diphenyl-methane-diisocyanate or toluene-diisocyanate and modifying the pH in keratin solutions were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy, and dynamical mechanical analysis. Results show that pH has a strong influence on morphology and on Cr(VI) removal efficiency. When pH in keratin solution is low (2.5), the protein separates from water, and a more closed cell in the membrane is obtained affecting its mechanical properties. The removal efficiency of Cr(VI) was also assessed at different pH values of chromium solutions. These results show that when pH of the Cr solution is acidic (at 1.5), the Cr(VI) removal percentages increase significantly, reaching up to a 58%. Thus this paper demonstrates the successful combination of synthetic and natural polymers depending on the process parameters to be applied in the critical purpose of remediation of Cr(VI) contamination.