Mattias Jönsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mattias Jönsson has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Gunnar Björk
Department of Applied Physics Royal Institute of Technology (KTH) AlbaNova University Center SE -106 91 Stockholm Sweden
7 shared publications - Samuel Gyger
Department of Applied Physics and Ginzton Laboratory, Stanford University , 348 Via Pueblo Mall, Stanford, California 94305
3 shared publications Val Zwiller
Quantum Nano Photonics Group, Department of Applied Physics, Royal Institute of Technology (KTH), Stockholm 10691, Sweden
3 shared publications- Jack Lidmar
Theoretical Physics AlbaNova KTH Royal Institute of Technology SE-106 91 Stockholm Sweden
2 shared publications - Stephan Steinhauer
Department of Applied Physics, KTH Royal Institute of Technology, 106 91 Stockholm, Sweden
2 shared publications - Chun-Liang Lin
National yang Ming Chiao Tung University
1 shared publication
Latest Publications
- 27 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Optical Materials
- Vol. 2 (1) , 68-75
Visualizing Local Superconductivity of NbTiN Nanowires to Probe Inhomogeneity in Single-Photon Detectors
- 27 December 2023
- Published by American Chemical Society (ACS) in ACS Applied Optical Materials
- Vol. 2 (1) , 68-75
Visualizing Local Superconductivity of NbTiN Nanowires to Probe Inhomogeneity in Single-Photon Detectors
- Open Access
- 24 June 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (6) , 064046
Current Crowding in Nanoscale Superconductors within the Ginzburg-Landau Model
The current density in a superconductor with turnarounds or constrictions is nonuniform due to a geometrical current-crowding effect. This effect reduces the critical current in the superconducting structure compared to a straight segment and is of importance when designing superconducting devices. We investigate the current-crowding effect in numerical simulations within the generalized time-dependent Ginzburg-Landau (GTDGL) model. The results are validated experimentally by measuring the magnetic field dependence of the critical current in superconducting-nanowire structures, similar to those employed in single-photon detector devices. Comparing the results with London theory, we conclude that the reduction in critical current is significantly smaller in the GTDGL model. This difference is attributed to the current redistribution effect, which reduces the current density at weak points of the superconductor and counteracts the current-crowding effect. We numerically investigate the effect of the fill factor on the critical current in a meander and conclude that the reduction of the critical current is low enough to justify fill factors higher than 33% for applications where the detection efficiency is critical. Finally, we propose a meander design that can combine a high fill factor and low current crowding.
- 24 June 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (6) , 064046
Open AccessCurrent Crowding in Nanoscale Superconductors within the Ginzburg-Landau Model
The current density in a superconductor with turnarounds or constrictions is nonuniform due to a geometrical current-crowding effect. This effect reduces the critical current in the superconducting structure compared to a straight segment and is of importance when designing superconducting devices. We investigate the current-crowding effect in numerical simulations within the generalized time-dependent Ginzburg-Landau (GTDGL) model. The results are validated experimentally by measuring the magnetic field dependence of the critical current in superconducting-nanowire structures, similar to those employed in single-photon detector devices. Comparing the results with London theory, we conclude that the reduction in critical current is significantly smaller in the GTDGL model. This difference is attributed to the current redistribution effect, which reduces the current density at weak points of the superconductor and counteracts the current-crowding effect. We numerically investigate the effect of the fill factor on the critical current in a meander and conclude that the reduction of the critical current is low enough to justify fill factors higher than 33% for applications where the detection efficiency is critical. Finally, we propose a meander design that can combine a high fill factor and low current crowding.
- Open Access
- 23 November 2020
- Published by American Physical Society (APS) in Physical Review A
- Vol. 102 (5) , 052616
Temporal array with superconducting nanowire single-photon detectors for photon-number resolution
We present an experimental realization of a 16 element, temporal-array, photon-number-resolving (PNR) detector, which is a multiplexed single-photon detector that splits an input signal over multiple time bins, and the time bins are detected using two superconducting nanowire single-photon detectors (SNSPD). A theoretical investigation of the PNR capabilities of the detector is performed and it is concluded that, compared to a single-photon detector, our array detector can resolve one order of magnitude higher mean photon numbers, given the same number of input pulses to measure. This claim is experimentally verified and we show that the detector can accurately predict photon numbers between and . Our present detector is incapable of single-shot photon-number measurements with high precision since its effective quantum efficiency is . Using SNSPDs with a higher quantum efficiency the PNR performance will improve, but the photon-number resolution will still be limited by the array size.- 23 November 2020
- Published by American Physical Society (APS) in Physical Review A
- Vol. 102 (5) , 052616
Open AccessTemporal array with superconducting nanowire single-photon detectors for photon-number resolution
We present an experimental realization of a 16 element, temporal-array, photon-number-resolving (PNR) detector, which is a multiplexed single-photon detector that splits an input signal over multiple time bins, and the time bins are detected using two superconducting nanowire single-photon detectors (SNSPD). A theoretical investigation of the PNR capabilities of the detector is performed and it is concluded that, compared to a single-photon detector, our array detector can resolve one order of magnitude higher mean photon numbers, given the same number of input pulses to measure. This claim is experimentally verified and we show that the detector can accurately predict photon numbers between and . Our present detector is incapable of single-shot photon-number measurements with high precision since its effective quantum efficiency is . Using SNSPDs with a higher quantum efficiency the PNR performance will improve, but the photon-number resolution will still be limited by the array size. - Open Access
- 2 September 2020
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 2 (4) , 045008
Contrast resolution of few-photon detectors
We investigate the minimum acquisition time, expressed as the number of image frames, and the minimum number of absorbed photons per pixel required to achieve a predefined contrast resolution in a monochromatic, pixelated image acquisition system at low light intensities (from well below one photon, to several hundred photons per pixel and frame). Primarily we compare systems based on the pixels of the photon-number-resolving (PNR) type of detectors and detectors that discriminate, in a binary fashion, between zero and non-zero photon numbers (so-called click detectors). We find that our model can seamlessly interpolate between the two. We also model detectors with intrinsic PNR capabilities and integrating detectors with a simple saturation model, derive the probability of errors in assigning the correct intensity (or ‘gray level’) and finally discuss how the estimated levels, which need to be based on threshold levels due to the stochastic nature of the detected photon number, should be assigned. Overall, we find that non-ideal PNR-detector-based systems offer advantages even over ideal click-detector-based systems when the incident mean photon number is sufficiently large, which is guaranteed to occur around ten photons per pixel and frame.
- 2 September 2020
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 2 (4) , 045008
Open AccessContrast resolution of few-photon detectors
We investigate the minimum acquisition time, expressed as the number of image frames, and the minimum number of absorbed photons per pixel required to achieve a predefined contrast resolution in a monochromatic, pixelated image acquisition system at low light intensities (from well below one photon, to several hundred photons per pixel and frame). Primarily we compare systems based on the pixels of the photon-number-resolving (PNR) type of detectors and detectors that discriminate, in a binary fashion, between zero and non-zero photon numbers (so-called click detectors). We find that our model can seamlessly interpolate between the two. We also model detectors with intrinsic PNR capabilities and integrating detectors with a simple saturation model, derive the probability of errors in assigning the correct intensity (or ‘gray level’) and finally discuss how the estimated levels, which need to be based on threshold levels due to the stochastic nature of the detected photon number, should be assigned. Overall, we find that non-ideal PNR-detector-based systems offer advantages even over ideal click-detector-based systems when the incident mean photon number is sufficiently large, which is guaranteed to occur around ten photons per pixel and frame.
- Open Access
Contrast resolution of few-photon detectors
We analyse the capability of distinguishing between different intensities in a monochromatic, pixellated image acquisition system at low light intensities. In practice, the latter means that each pixel detects a countable number of photons per acquired image frame. Primarily we compare systems based on pixels of the click-detection type and photon-number resolving (PNR) type of detectors, but our model can seamlessly interpolate between the two. We also discuss the probability of errors in assigning the correct intensity (or "gray level"), and finally we discuss how the estimated levels, that need to be based on threshold levels due to the stochastic nature of the detected photon number, should be assigned. Overall, we find that PNR detector-based system offer advantages over click-detector-based systems even under rather non-ideal conditions.
Open AccessContrast resolution of few-photon detectors
We analyse the capability of distinguishing between different intensities in a monochromatic, pixellated image acquisition system at low light intensities. In practice, the latter means that each pixel detects a countable number of photons per acquired image frame. Primarily we compare systems based on pixels of the click-detection type and photon-number resolving (PNR) type of detectors, but our model can seamlessly interpolate between the two. We also discuss the probability of errors in assigning the correct intensity (or "gray level"), and finally we discuss how the estimated levels, that need to be based on threshold levels due to the stochastic nature of the detected photon number, should be assigned. Overall, we find that PNR detector-based system offer advantages over click-detector-based systems even under rather non-ideal conditions.
- 15 January 2020
- Published by American Physical Society (APS) in Physical Review A
- Vol. 101 (1) , 013815
Photon-counting distribution for arrays of single-photon detectors
We derive a computationally efficient expression of the photon-counting distribution for a uniformly illuminated array of single-photon detectors. The expression takes the number of single detectors, their quantum efficiency, and their dark count rate into account. Using this distribution we compute the error of the array detector by comparing the output to that of an ideal detector. We conclude from the error analysis that the quantum efficiency must be very high in order for the detector to resolve a handful of photons with high probability. Furthermore, we conclude that in the worst-case scenario the required array size scales quadratically with the number of photons that should be resolved. We also simulate a temporal array and investigate how large the error is for different parameters, and we compute the optimal size of the array that yields the smallest error.
- 15 January 2020
- Published by American Physical Society (APS) in Physical Review A
- Vol. 101 (1) , 013815
Photon-counting distribution for arrays of single-photon detectors
We derive a computationally efficient expression of the photon-counting distribution for a uniformly illuminated array of single-photon detectors. The expression takes the number of single detectors, their quantum efficiency, and their dark count rate into account. Using this distribution we compute the error of the array detector by comparing the output to that of an ideal detector. We conclude from the error analysis that the quantum efficiency must be very high in order for the detector to resolve a handful of photons with high probability. Furthermore, we conclude that in the worst-case scenario the required array size scales quadratically with the number of photons that should be resolved. We also simulate a temporal array and investigate how large the error is for different parameters, and we compute the optimal size of the array that yields the smallest error.
- Open Access
Photon Counting Distribution for Arrays of Single-Photon Detectors
We derive a computationally efficient expression of the photon counting distribution for a uniformly illuminated array of single photon detectors. The expression takes the number of single detectors, their quantum efficiency, and their dark-count rate into account. Using this distribution we compute the error of the array detector by comparing the output to that of a ideal detector. We conclude from the error analysis that the quantum efficiency must be very high in order for the detector to resolve a hand-full of photons with high probability. Furthermore, we conclude that in the worst-case scenario the required array size scales quadratically with the number of photons that should be resolved. We also simulate a temporal array and investigate how large the error is for different parameters and we compute optimal size of the array that yields the smallest error.
Open AccessPhoton Counting Distribution for Arrays of Single-Photon Detectors
We derive a computationally efficient expression of the photon counting distribution for a uniformly illuminated array of single photon detectors. The expression takes the number of single detectors, their quantum efficiency, and their dark-count rate into account. Using this distribution we compute the error of the array detector by comparing the output to that of a ideal detector. We conclude from the error analysis that the quantum efficiency must be very high in order for the detector to resolve a hand-full of photons with high probability. Furthermore, we conclude that in the worst-case scenario the required array size scales quadratically with the number of photons that should be resolved. We also simulate a temporal array and investigate how large the error is for different parameters and we compute optimal size of the array that yields the smallest error.
- 16 April 2019
- Published by American Physical Society (APS) in Physical Review A
- Vol. 99 (4) , 043822
Evaluating the performance of photon-number-resolving detectors
We analyze the performance of photon-number-resolving (PNR) detectors and introduce a figure of merit for the accuracy of such detectors. This figure of merit is the (worst-case) probability that the photon-number-resolving detector correctly predicts the input photon number. Simulations of various PNR detectors based on multiplexed single-photon “click detectors” is performed. We conclude that the required quantum efficiency is very high in order to achieve even moderate (up to a handful) photon resolution, we derive the required quantum efficiency as a function of the the maximal photon number one wants to resolve, and we show that the number of click detectors required grows quadratically with the maximal number of photons resolvable.
- 16 April 2019
- Published by American Physical Society (APS) in Physical Review A
- Vol. 99 (4) , 043822
Evaluating the performance of photon-number-resolving detectors
We analyze the performance of photon-number-resolving (PNR) detectors and introduce a figure of merit for the accuracy of such detectors. This figure of merit is the (worst-case) probability that the photon-number-resolving detector correctly predicts the input photon number. Simulations of various PNR detectors based on multiplexed single-photon “click detectors” is performed. We conclude that the required quantum efficiency is very high in order to achieve even moderate (up to a handful) photon resolution, we derive the required quantum efficiency as a function of the the maximal photon number one wants to resolve, and we show that the number of click detectors required grows quadratically with the maximal number of photons resolvable.
- Open Access
Evaluating Performance of Photon-Number-Resolving Detectors
We analyze the performance of photon-number-resolving (PNR) detectors and introduce a figure of merit for the accuracy of such detectors. This figure of merit is the (worst-case) probability that the photon-number-resolving detector correctly predicts the input photon number. Simulations of various PNR detectors based on multiplexed single-photon `click detectors' is performed. We conclude that the required quantum efficiency is very high in order to achieve even moderate (up to a handful) photon resolution, we derive the required quantum efficiency as a function of the the maximal photon number one wants to resolve, and we show that the number of click detectors required grows quadratically with the maximal number of photons resolvable.
Open AccessEvaluating Performance of Photon-Number-Resolving Detectors
We analyze the performance of photon-number-resolving (PNR) detectors and introduce a figure of merit for the accuracy of such detectors. This figure of merit is the (worst-case) probability that the photon-number-resolving detector correctly predicts the input photon number. Simulations of various PNR detectors based on multiplexed single-photon `click detectors' is performed. We conclude that the required quantum efficiency is very high in order to achieve even moderate (up to a handful) photon resolution, we derive the required quantum efficiency as a function of the the maximal photon number one wants to resolve, and we show that the number of click detectors required grows quadratically with the maximal number of photons resolvable.