Peiqi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peiqi Zhao has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yongqing Meng
School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710100, China
5 shared publications Mengwei Ge
State Key Laboratory of Electrical Insulation and Power Equipment, Shaanxi Province Key Laboratory of Smart Grid, Xian Jiaotong University, Xian, China
3 shared publications- Xiuli Wang
Xi'an Jiaotong University
3 shared publications - Shuhao Yan
State Key Laboratory of Electrical Insulation and Power Equipment, Shaanxi Province Key Laboratory of Smart Grid, Xian Jiaotong University, Xian, China
2 shared publications Xifan Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Shaanxi Province Key Laboratory of Smart Grid, Xian Jiaotong University, Xian, China
2 shared publications- Zhen Zhang
School of Energy and Electrical Engineering, Chang’an University, Xi’an 710064, China
2 shared publications
Latest Publications
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2466-2478
Series-Parallel DC Collection Topology and Control for All-DC Offshore Wind Power System Considering MPPT and Surplus Power Distribution
All-dc offshore wind power system is a promising solution for long distance and high-power transmission. This paper proposes a series-parallel connected DC collection topology for all-dc offshore wind power system. On the one hand, a novel series-parallel modular multilevel converter is proposed for the medium-voltage high-power wind turbines. This converter adopts series-parallel connection to raise the voltage level of the wind turbine and the special structure with multi-winding transformers can eliminate the secondary power fluctuations, thus reducing the dc-link capacitor requirement. On the other hand, considering the wind power difference among the series wind turbines, a power balancing system is configured to balance the surplus power among the series WTs, thereby achieving maximum power point tracking of the series WTs. Compare to the traditional offshore wind power transmission system, the proposed topology cancels the expensive offshore platform, and solve the wind power curtailment problem. In addition, the corresponding control and modulation scheme of the proposed topology are implemented. Digital simulation and real time hard-in-loop simulation tests are conducted to verify the effectiveness and superiority of the proposed DC collection topology.
- 16 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2466-2478
Series-Parallel DC Collection Topology and Control for All-DC Offshore Wind Power System Considering MPPT and Surplus Power Distribution
All-dc offshore wind power system is a promising solution for long distance and high-power transmission. This paper proposes a series-parallel connected DC collection topology for all-dc offshore wind power system. On the one hand, a novel series-parallel modular multilevel converter is proposed for the medium-voltage high-power wind turbines. This converter adopts series-parallel connection to raise the voltage level of the wind turbine and the special structure with multi-winding transformers can eliminate the secondary power fluctuations, thus reducing the dc-link capacitor requirement. On the other hand, considering the wind power difference among the series wind turbines, a power balancing system is configured to balance the surplus power among the series WTs, thereby achieving maximum power point tracking of the series WTs. Compare to the traditional offshore wind power transmission system, the proposed topology cancels the expensive offshore platform, and solve the wind power curtailment problem. In addition, the corresponding control and modulation scheme of the proposed topology are implemented. Digital simulation and real time hard-in-loop simulation tests are conducted to verify the effectiveness and superiority of the proposed DC collection topology.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9986-9999
Interaction Large-Signal Stability Analysis of M3C and GFM/GFL Hybrid Control Strategies Converters Based on the Novel Fuzzy Tensor Space Method
This article proposes a novel fuzzy tensor space method to analyze the interaction large-signal stability of modular multilevel matrix converter (M3C) and grid-forming/following (GFM/GFL) hybrid control strategy converters. By addressing the challenges of high-order, strong nonlinearity, and multi-frequency coupling in the system's dynamic model, the complexity is reduced from exponential to constant levels using sector nonlinearity theory. It is achieved by optimizing the original membership function set into a linearly independent fuzzy tensor basis. Additionally, leveraging the physical significance of the fuzzy tensor space reduces the mapping area for solving the Lyapunov functional problem, effectively lowering the conservatism. Furthermore, the stability analysis results obtained from this method offer a better balance of complexity and accuracy compared to traditional TS fuzzy theory. Based on the improved method, the complex coupling stability mechanism caused by the interaction of multiple power electronic devices and control strategies can be analyzed quickly and accurately. In particular, these results are used to study the impact of different configurations of GFM/GFL converters under various disturbance conditions, as well as the interaction stability mechanism of different configuration ratios combined with grid strength. Finally, the validity of these results is confirmed through theoretical and experimental verification.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9986-9999
Interaction Large-Signal Stability Analysis of M3C and GFM/GFL Hybrid Control Strategies Converters Based on the Novel Fuzzy Tensor Space Method
This article proposes a novel fuzzy tensor space method to analyze the interaction large-signal stability of modular multilevel matrix converter (M3C) and grid-forming/following (GFM/GFL) hybrid control strategy converters. By addressing the challenges of high-order, strong nonlinearity, and multi-frequency coupling in the system's dynamic model, the complexity is reduced from exponential to constant levels using sector nonlinearity theory. It is achieved by optimizing the original membership function set into a linearly independent fuzzy tensor basis. Additionally, leveraging the physical significance of the fuzzy tensor space reduces the mapping area for solving the Lyapunov functional problem, effectively lowering the conservatism. Furthermore, the stability analysis results obtained from this method offer a better balance of complexity and accuracy compared to traditional TS fuzzy theory. Based on the improved method, the complex coupling stability mechanism caused by the interaction of multiple power electronic devices and control strategies can be analyzed quickly and accurately. In particular, these results are used to study the impact of different configurations of GFM/GFL converters under various disturbance conditions, as well as the interaction stability mechanism of different configuration ratios combined with grid strength. Finally, the validity of these results is confirmed through theoretical and experimental verification.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2482-2494
Series-Parallel Multiple Integrated Modular Multilevel DC-DC Converter for All-DC Offshore Wind Power System
All-dc offshore wind power system is a promising solution for long distance and high power transmission. This paper proposes a series-parallel multiple integrated modular multilevel dc-dc converter (SPMI-MMC) for all-dc offshore wind power systems to meet its demand for high voltage, high power, and large-step ratio dc voltage transmission. Different from the traditional isolated dc-dc converter, the submodules (SMs) of the SPMI-MMC adopt the input-parallel-output-series (IPOS) arrangement to achieve a large step ratio. The symmetrical parallel multiple submodule (SPM-SM) is proposed to realize parallel multiple of SMs through coupling reactors (CRs), which not only can enhance the large current operation ability but also can cancel out the nonzero-sequence high frequency harmonics. Considering the cost factor, the simplified full-bridge double submodule (S-FBDSM) is first introduced in dc-dc converter. It is economical and has good bidirectional dc-fault blocking ability. Digital simulation and real time hard-in-loop (HIL) simulation tests are conducted to verify the effectiveness and superiority of the proposed SPMI-MMC.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2482-2494
Series-Parallel Multiple Integrated Modular Multilevel DC-DC Converter for All-DC Offshore Wind Power System
All-dc offshore wind power system is a promising solution for long distance and high power transmission. This paper proposes a series-parallel multiple integrated modular multilevel dc-dc converter (SPMI-MMC) for all-dc offshore wind power systems to meet its demand for high voltage, high power, and large-step ratio dc voltage transmission. Different from the traditional isolated dc-dc converter, the submodules (SMs) of the SPMI-MMC adopt the input-parallel-output-series (IPOS) arrangement to achieve a large step ratio. The symmetrical parallel multiple submodule (SPM-SM) is proposed to realize parallel multiple of SMs through coupling reactors (CRs), which not only can enhance the large current operation ability but also can cancel out the nonzero-sequence high frequency harmonics. Considering the cost factor, the simplified full-bridge double submodule (S-FBDSM) is first introduced in dc-dc converter. It is economical and has good bidirectional dc-fault blocking ability. Digital simulation and real time hard-in-loop (HIL) simulation tests are conducted to verify the effectiveness and superiority of the proposed SPMI-MMC.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1624-1628
A Novel Droop Control of Grid Converter to Enhance Small Signal Stability of Fractional Frequency Wind Power System
Wind power transmitted through fractional frequency wind power system (FFWPS) is a promising scheme. The voltage stability of FFWPS is a very noteworthy issue. This paper proposes a voltage control method for wind power converters based on droop control to improve the small signal stability of FFWPS. By establishing the state space small-signal modeling of the system and using the eigenvalue analysis method, it is verified that the proposed control method can effectively improve the voltage stability of FFWPS. The simulation test verifies the correctness and effectiveness of the proposed method.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1624-1628
A Novel Droop Control of Grid Converter to Enhance Small Signal Stability of Fractional Frequency Wind Power System
Wind power transmitted through fractional frequency wind power system (FFWPS) is a promising scheme. The voltage stability of FFWPS is a very noteworthy issue. This paper proposes a voltage control method for wind power converters based on droop control to improve the small signal stability of FFWPS. By establishing the state space small-signal modeling of the system and using the eigenvalue analysis method, it is verified that the proposed control method can effectively improve the voltage stability of FFWPS. The simulation test verifies the correctness and effectiveness of the proposed method.
- Open Access
- 6 July 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1175-1183
Battery storage configuration for multi-energy microgrid considering primary frequency regulation and demand response
- 6 July 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1175-1183
Open AccessBattery storage configuration for multi-energy microgrid considering primary frequency regulation and demand response
- 1 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (3) , 2952-2962
Accurate Estimation of Positive- and Negative-Sequence Components for Three-Phase Grid Voltage Under Disturbances
In order to achieve the stable operation of three-phase grid systems, it is important to find an effective grid synchronization method for detecting the grid voltage parameters. A challenge for this problem is how to extract the positive- and negative-sequence components of the grid voltage rapidly and accurately under distorted conditions. Different from traditional phase-locked-loop (PLL)-based methods, in this paper, an adaptive observer-based method is proposed to estimate the positive- and negative-sequence components of the grid voltage. By establishing a dynamic model containing the three-phase grid voltage signal and its derivatives, an adaptive observer is obtained to estimate the grid frequency and then obtain the estimation of the positive- and negative-sequence components of the grid voltage. The experimental results show that the proposed method has good dynamic response and steady-state accuracy under distortion conditions.
- 1 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (3) , 2952-2962
Accurate Estimation of Positive- and Negative-Sequence Components for Three-Phase Grid Voltage Under Disturbances
In order to achieve the stable operation of three-phase grid systems, it is important to find an effective grid synchronization method for detecting the grid voltage parameters. A challenge for this problem is how to extract the positive- and negative-sequence components of the grid voltage rapidly and accurately under distorted conditions. Different from traditional phase-locked-loop (PLL)-based methods, in this paper, an adaptive observer-based method is proposed to estimate the positive- and negative-sequence components of the grid voltage. By establishing a dynamic model containing the three-phase grid voltage signal and its derivatives, an adaptive observer is obtained to estimate the grid frequency and then obtain the estimation of the positive- and negative-sequence components of the grid voltage. The experimental results show that the proposed method has good dynamic response and steady-state accuracy under distortion conditions.
- Open Access
- 31 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 8477-8484
Fast Amplitude Estimation for Low-Voltage Ride-Through Operation of Single-Phase Systems
Estimating the amplitude of the grid voltage is important for low-voltage ride-through (LVRT) operation in single-phase systems. It requires fast dynamics and is typically achieved through a phase-locked loop (PLL). This paper proposes a fast amplitude estimation (FAE) method without a PLL structure. The grid voltage is formulated as a vector sum of sine and cosine functions, resulting in an algebraic model with two unknown parameters. The proposed FAE identifies the two parameters, and thus achieving a fast fault detection (i.e., the amplitude estimation). Experimental results verify the performance of the proposed method in terms of fast dynamics.
- 31 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 8477-8484
Open AccessFast Amplitude Estimation for Low-Voltage Ride-Through Operation of Single-Phase Systems
Estimating the amplitude of the grid voltage is important for low-voltage ride-through (LVRT) operation in single-phase systems. It requires fast dynamics and is typically achieved through a phase-locked loop (PLL). This paper proposes a fast amplitude estimation (FAE) method without a PLL structure. The grid voltage is formulated as a vector sum of sine and cosine functions, resulting in an algebraic model with two unknown parameters. The proposed FAE identifies the two parameters, and thus achieving a fast fault detection (i.e., the amplitude estimation). Experimental results verify the performance of the proposed method in terms of fast dynamics.