Jeong Ho Ha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeong Ho Ha has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Byung Hyun Byun
Department of Nuclear Medicine, Korea Cancer Center Hospital Korea Institute of Radiological & Medical Sciences Seoul South Korea
3 shared publications Ilhan Lim
Department of Nuclear Medicine, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul, Republic of Korea
3 shared publications- Inki Lee
Department of Nuclear Medicine, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences, Seoul, Korea
3 shared publications Su Yeon Park
Departments of Neurology, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul, Republic of Korea
3 shared publicationsByung Hyun Byun
Department of Nuclear Medicine, Korea Cancer Center Hospital
2 shared publicationsByung Il Kim
Department of Nuclear Medicine, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 22 June 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (6) , e70352
Integrating visual assessments and quantification methods for tau PET staging
INTRODUCTION: We compared visual assessments and quantification methods for tau positron emission tomography (PET) staging and evaluated plasma biomarkers and cognitive trajectories across amyloid and tau (AT) staging.METHODS: Tau PET scans from 289 Korea‐Registries to Overcome Dementia and Accelerate Dementia Research (K‐ROAD) participants were analyzed visually and quantitatively, with validation in the Alzheimer's Disease Neuroimaging Initiative (ADNI) cohort (n = 870). Plasma biomarkers and cognitive measures were evaluated across AT stages.RESULTS: FreeSurfer without partial volume correction (PVC) achieved the highest area under the curve (AUC) for tau positivity (0.918), based on visual interpretation. The temporal meta‐region excelled in moderate tau staging (AUC = 0.856), while the temporoparietal region performed best for advanced staging (AUC = 0.828). Quantification methods detected phosphorylated tau217 changes during intermediate transitions (e.g., A+/T− to A+/Tmod+) more effectively. Plasma biomarkers and cognitive measures progressively changed across AT stages, with consistent results in K‐ROAD and ADNI cohorts.DISCUSSION: The complementary strengths of visual and quantification methods enhance tau PET staging by effectively capturing biomarker changes and cognitive trajectories.Highlights: Quantification partially outperformed visual assessments in detecting early tau burdens. Meta‐temporal and temporoparietal regions of interest excelled in early and late tau staging. Quantification methods correlated with plasma phosphorylated tau217 and cognitive decline. Findings were validated across two independent cohorts (Korea‐Registries to Overcome Dementia and Accelerate Dementia Research and Alzheimer's Disease Neuroimaging Initiative). The study highlights the complementary roles of visual and quantification methods.
- 22 June 2025
- Published by Wiley in Alzheimer's & Dementia
- Vol. 21 (6) , e70352
Open AccessIntegrating visual assessments and quantification methods for tau PET staging
INTRODUCTION: We compared visual assessments and quantification methods for tau positron emission tomography (PET) staging and evaluated plasma biomarkers and cognitive trajectories across amyloid and tau (AT) staging.METHODS: Tau PET scans from 289 Korea‐Registries to Overcome Dementia and Accelerate Dementia Research (K‐ROAD) participants were analyzed visually and quantitatively, with validation in the Alzheimer's Disease Neuroimaging Initiative (ADNI) cohort (n = 870). Plasma biomarkers and cognitive measures were evaluated across AT stages.RESULTS: FreeSurfer without partial volume correction (PVC) achieved the highest area under the curve (AUC) for tau positivity (0.918), based on visual interpretation. The temporal meta‐region excelled in moderate tau staging (AUC = 0.856), while the temporoparietal region performed best for advanced staging (AUC = 0.828). Quantification methods detected phosphorylated tau217 changes during intermediate transitions (e.g., A+/T− to A+/Tmod+) more effectively. Plasma biomarkers and cognitive measures progressively changed across AT stages, with consistent results in K‐ROAD and ADNI cohorts.DISCUSSION: The complementary strengths of visual and quantification methods enhance tau PET staging by effectively capturing biomarker changes and cognitive trajectories.Highlights: Quantification partially outperformed visual assessments in detecting early tau burdens. Meta‐temporal and temporoparietal regions of interest excelled in early and late tau staging. Quantification methods correlated with plasma phosphorylated tau217 and cognitive decline. Findings were validated across two independent cohorts (Korea‐Registries to Overcome Dementia and Accelerate Dementia Research and Alzheimer's Disease Neuroimaging Initiative). The study highlights the complementary roles of visual and quantification methods.
- 20 February 2025
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 59 (4) , 229-238
Cutoff SUVR of [18F]Florapronol PET for Differentiating Alzheimer’s Dementia from Normal Controls: Insights from ROC Analysis and Partial Volume Correction
Objectives The primary endpoint of this study is to establish a reliable SUVR cutoff threshold to distinguish patients with Alzheimer’s disease (AD), excluding those with mild cognitive impairment (MCI), from normal control (NC) individuals using [18F]florapronol PET imaging and deep learning-based automated quantification software. The secondary endpoint is to evaluate whether combining partial volume correction (PVC) with SUVR analysis improves diagnostic accuracy in detecting AD. Methods A total of 141 participants, including 55 AD patients (excluding MCI) and 86 NC controls, were enrolled. Each participant underwent [18F]florapronol PET imaging, and SUVR values were calculated for six amyloid-prone brain regions using deep learning-based software. SUVRs were computed with and without PVC, using the cerebellar cortex as the reference region. Receiver operating characteristic (ROC) analysis identified optimal SUVR thresholds for distinguishing AD (excluding MCI) from NC and for determining visual positivity. Age-matched subgroup analyses ensured consistent diagnostic performance across different age groups. Results In the full cohort (n = 141), visual analysis achieved a sensitivity of 90.9% and specificity of 94.1% for distinguishing AD from NC. SUVR without PVC reached a similar sensitivity of 90.9% and specificity of 86.0% (optimal threshold > 1.26), while PVC-adjusted SUVR further improved accuracy with a sensitivity of 90.9% and specificity of 94.2% at a threshold of > 1.31. For visual positivity, SUVR without PVC achieved 92.7% sensitivity and 89.5% specificity, while PVC-adjusted SUVR improved these metrics to 96.4% sensitivity and 94.2% specificity. Age-matched analyses confirmed diagnostic consistency across different age groups. The visual analysis and the quantitative analysis using SUVR with PVC as the threshold were consistent in 134 out of 141 subjects (95.0%). Conclusions Automated SUVR quantification with PVC adjustment provides a reliable and objective method for distinguishing AD from NC, aligning closely with visual assessment accuracy and supporting clinical use of [18F]florapronol PET imaging for AD diagnosis. This standardized approach enhances diagnostic consistency, particularly in settings with limited access to PET specialists, and establishes robust SUVR thresholds for broader clinical application in amyloid PET imaging.
- 20 February 2025
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 59 (4) , 229-238
Cutoff SUVR of [18F]Florapronol PET for Differentiating Alzheimer’s Dementia from Normal Controls: Insights from ROC Analysis and Partial Volume Correction
Objectives The primary endpoint of this study is to establish a reliable SUVR cutoff threshold to distinguish patients with Alzheimer’s disease (AD), excluding those with mild cognitive impairment (MCI), from normal control (NC) individuals using [18F]florapronol PET imaging and deep learning-based automated quantification software. The secondary endpoint is to evaluate whether combining partial volume correction (PVC) with SUVR analysis improves diagnostic accuracy in detecting AD. Methods A total of 141 participants, including 55 AD patients (excluding MCI) and 86 NC controls, were enrolled. Each participant underwent [18F]florapronol PET imaging, and SUVR values were calculated for six amyloid-prone brain regions using deep learning-based software. SUVRs were computed with and without PVC, using the cerebellar cortex as the reference region. Receiver operating characteristic (ROC) analysis identified optimal SUVR thresholds for distinguishing AD (excluding MCI) from NC and for determining visual positivity. Age-matched subgroup analyses ensured consistent diagnostic performance across different age groups. Results In the full cohort (n = 141), visual analysis achieved a sensitivity of 90.9% and specificity of 94.1% for distinguishing AD from NC. SUVR without PVC reached a similar sensitivity of 90.9% and specificity of 86.0% (optimal threshold > 1.26), while PVC-adjusted SUVR further improved accuracy with a sensitivity of 90.9% and specificity of 94.2% at a threshold of > 1.31. For visual positivity, SUVR without PVC achieved 92.7% sensitivity and 89.5% specificity, while PVC-adjusted SUVR improved these metrics to 96.4% sensitivity and 94.2% specificity. Age-matched analyses confirmed diagnostic consistency across different age groups. The visual analysis and the quantitative analysis using SUVR with PVC as the threshold were consistent in 134 out of 141 subjects (95.0%). Conclusions Automated SUVR quantification with PVC adjustment provides a reliable and objective method for distinguishing AD from NC, aligning closely with visual assessment accuracy and supporting clinical use of [18F]florapronol PET imaging for AD diagnosis. This standardized approach enhances diagnostic consistency, particularly in settings with limited access to PET specialists, and establishes robust SUVR thresholds for broader clinical application in amyloid PET imaging.
- 3 March 2021
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 46 (8) , e431-e432
Incidental 18F-Florapronol Uptake in Meningioma
A 76-year-old woman underwent 18F-florapronol (18F-FC119S, an amyloid β imaging PET agent) PET, owing to cognitive impairment. 18F-florapronol PET images revealed an incidental 18F-florapronol uptake in the right frontal lobe. A well-enhancing extra-axial mass in the right frontal lobe was observed on MRI scans, suggesting a meningioma. After excision of the tumor, the biopsy results confirmed it as a meningothelial meningioma.
- 3 March 2021
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 46 (8) , e431-e432
Incidental 18F-Florapronol Uptake in Meningioma
A 76-year-old woman underwent 18F-florapronol (18F-FC119S, an amyloid β imaging PET agent) PET, owing to cognitive impairment. 18F-florapronol PET images revealed an incidental 18F-florapronol uptake in the right frontal lobe. A well-enhancing extra-axial mass in the right frontal lobe was observed on MRI scans, suggesting a meningioma. After excision of the tumor, the biopsy results confirmed it as a meningothelial meningioma.
- Open Access
- 1 April 2020
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (16) , e19620
The correlation of neuropsychological evaluation with 11C-PiB and 18F-FC119S amyloid PET in mild cognitive impairment and Alzheimer disease
For the diagnosis of mild cognitive impairment (MCI) and Alzheimer disease (AD), variable neuroimaging and neuropsychological tests have been used. We aimed to evaluate the correlation of neuropsychological domain with new amyloid positron emission tomography (PET) study and to validate the availability of new PET tracer. We enrolled 20 patients who underwent 11C-PiB-PET/CT, new PET tracer 18F-FC119S PET/CT from November, 2014 to July, 2015. Among them, 10 patients were diagnosed with AD and 10 patients with MCI. The current version of Seoul Neuropsychological Screening Battery (SNSB) II was performed for cognitive evaluation. Each parameter of SNSB was compared between 2 patient groups. Spearman correlation analysis between value of SNSB domain and standardized uptake value ratio (SUVR) of PET was also performed. The AD group presented significant poor z-score in Korean-Boston Naming Test(K-BNT) (P = .01),copy score of Rey Complex Figure Test (RCFT) (P = .049), immediate (P = .028)and delayed memory of Seoul Verbal Learning Test (SVLT) (P = .028), recognition of RCFT (P = .004), “animal” of Controlled Oral Word Association Test (COWAT) (P = .041), color reading of Korean-Color Word Stroop test (K-CWST) (P = .014), and Digit Symbol Coding (DSC) (P = .007) compared with MCI group. That means, except attention domain, all other cognitive domains were relatively impaired in AD compared with MCI. In correlation analysis, we found that poor performances on copy score of RCFT in MCI groups were associated with great beta amyloid burden in frontal area in both 11C-PiB-PET/CT and 18F-FC119S PET/CT. In AD group, 18F-FC119S PET presented more extensive correlation in each cognitive domain with multiple cortical areas compared with 11C-PiB-PET. The degree of amyloid burden assessed on 18F-FC119S PET was significantly correlated with neuropsychological test in AD, and also MCI patients. The combination of neuropsychological evaluation with novel 18F-FC119S PET/CT can be used for valid biomarker for MCI and AD.
- 1 April 2020
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (16) , e19620
Open AccessThe correlation of neuropsychological evaluation with 11C-PiB and 18F-FC119S amyloid PET in mild cognitive impairment and Alzheimer disease
For the diagnosis of mild cognitive impairment (MCI) and Alzheimer disease (AD), variable neuroimaging and neuropsychological tests have been used. We aimed to evaluate the correlation of neuropsychological domain with new amyloid positron emission tomography (PET) study and to validate the availability of new PET tracer. We enrolled 20 patients who underwent 11C-PiB-PET/CT, new PET tracer 18F-FC119S PET/CT from November, 2014 to July, 2015. Among them, 10 patients were diagnosed with AD and 10 patients with MCI. The current version of Seoul Neuropsychological Screening Battery (SNSB) II was performed for cognitive evaluation. Each parameter of SNSB was compared between 2 patient groups. Spearman correlation analysis between value of SNSB domain and standardized uptake value ratio (SUVR) of PET was also performed. The AD group presented significant poor z-score in Korean-Boston Naming Test(K-BNT) (P = .01),copy score of Rey Complex Figure Test (RCFT) (P = .049), immediate (P = .028)and delayed memory of Seoul Verbal Learning Test (SVLT) (P = .028), recognition of RCFT (P = .004), “animal” of Controlled Oral Word Association Test (COWAT) (P = .041), color reading of Korean-Color Word Stroop test (K-CWST) (P = .014), and Digit Symbol Coding (DSC) (P = .007) compared with MCI group. That means, except attention domain, all other cognitive domains were relatively impaired in AD compared with MCI. In correlation analysis, we found that poor performances on copy score of RCFT in MCI groups were associated with great beta amyloid burden in frontal area in both 11C-PiB-PET/CT and 18F-FC119S PET/CT. In AD group, 18F-FC119S PET presented more extensive correlation in each cognitive domain with multiple cortical areas compared with 11C-PiB-PET. The degree of amyloid burden assessed on 18F-FC119S PET was significantly correlated with neuropsychological test in AD, and also MCI patients. The combination of neuropsychological evaluation with novel 18F-FC119S PET/CT can be used for valid biomarker for MCI and AD.
- Open Access
- 1 January 2020
- Published by XMLink in Journal of Clinical Neurology
- Vol. 16 (1) , 131-139
Clinical Usefulness of 18F-FC119S Positron-Emission Tomography as an Auxiliary Diagnostic Method for Dementia: An Open-Label, Single-Dose, Evaluator-Blind Clinical Trial
The aim of this study was to determine the diagnostic performance and safety of a new ¹⁸F-labeled amyloid tracer, ¹⁸F-FC119S. This study prospectively recruited 105 participants, comprising 53 with Alzheimer's disease (AD) patients, 16 patients with dementia other than AD (non-AD), and 36 healthy controls (HCs). In the first screening visit, the Seoul Neuropsychological Screening Battery cognitive function test was given to the dementia group, while HC subjects completed the Korean version of the Mini Mental State Examination. Individuals underwent ¹⁸F-FC119S PET, ¹⁸F-fluorodeoxyglucose (FDG) PET, and brain MRI. The diagnostic performance of ¹⁸F-FC119S PET for AD was compared to a historical control (comprising previously reported and currently used amyloid-beta PET agents), ¹⁸F-FDG PET, and MRI. The standardized uptake value (SUV) ratio (ratio of the cerebral cortical SUV to the cerebellar SUV) was measured for each PET data set to provide semiquantitative analysis. All adverse effects during the clinical trial periods were monitored. Visual assessments of the ¹⁸F-FC119S PET data revealed a sensitivity of 92% and a specificity of 84% in detecting AD. ¹⁸F-FC119S PET demonstrated equivalent or better diagnostic performance for AD detection than the historical control, ¹⁸F-FDG PET (sensitivity of 80.0% and specificity of 76.0%), and MRI (sensitivity of 98.0% and specificity of 50.0%). The SUV ratios differed significantly between AD patients and the other groups, at 1.44±0.17 (mean±SD) for AD, 1.24±0.09 for non-AD, and 1.21±0.08 for HC. No clinically significant adverse effects occurred during the trial periods. ¹⁸F-FC119S PET provides high sensitivity and specificity in detecting AD and therefore may be considered a useful diagnostic tool for AD.
- 1 January 2020
- Published by XMLink in Journal of Clinical Neurology
- Vol. 16 (1) , 131-139
Open AccessClinical Usefulness of 18F-FC119S Positron-Emission Tomography as an Auxiliary Diagnostic Method for Dementia: An Open-Label, Single-Dose, Evaluator-Blind Clinical Trial
The aim of this study was to determine the diagnostic performance and safety of a new ¹⁸F-labeled amyloid tracer, ¹⁸F-FC119S. This study prospectively recruited 105 participants, comprising 53 with Alzheimer's disease (AD) patients, 16 patients with dementia other than AD (non-AD), and 36 healthy controls (HCs). In the first screening visit, the Seoul Neuropsychological Screening Battery cognitive function test was given to the dementia group, while HC subjects completed the Korean version of the Mini Mental State Examination. Individuals underwent ¹⁸F-FC119S PET, ¹⁸F-fluorodeoxyglucose (FDG) PET, and brain MRI. The diagnostic performance of ¹⁸F-FC119S PET for AD was compared to a historical control (comprising previously reported and currently used amyloid-beta PET agents), ¹⁸F-FDG PET, and MRI. The standardized uptake value (SUV) ratio (ratio of the cerebral cortical SUV to the cerebellar SUV) was measured for each PET data set to provide semiquantitative analysis. All adverse effects during the clinical trial periods were monitored. Visual assessments of the ¹⁸F-FC119S PET data revealed a sensitivity of 92% and a specificity of 84% in detecting AD. ¹⁸F-FC119S PET demonstrated equivalent or better diagnostic performance for AD detection than the historical control, ¹⁸F-FDG PET (sensitivity of 80.0% and specificity of 76.0%), and MRI (sensitivity of 98.0% and specificity of 50.0%). The SUV ratios differed significantly between AD patients and the other groups, at 1.44±0.17 (mean±SD) for AD, 1.24±0.09 for non-AD, and 1.21±0.08 for HC. No clinically significant adverse effects occurred during the trial periods. ¹⁸F-FC119S PET provides high sensitivity and specificity in detecting AD and therefore may be considered a useful diagnostic tool for AD.
Head‐to‐head comparison of 18F‐FP‐CIT and 123I‐FP‐CIT for dopamine transporter imaging in patients with Parkinson's disease: A preliminary study
123I‐FP‐CIT and 18F‐FP‐CIT are radiotracers which are widely used to diagnose Parkinson's disease (PD). However, to our knowledge, no studies to date have made head‐to‐head comparisons between 123I‐FP‐CIT and 18F‐FP‐CIT. Therefore, in this study, 123I‐FP‐CIT SPECT/CT was compared with 18F‐FP‐CIT PET/CT in the same cohort of subjects. Patients with PD and essential tremor (ET) underwent 123I‐FP‐CIT SPECT/CT and 18F‐FP‐CIT PET/CT. Visual and semiquantitative analyses were conducted. The specific binding ratio (SBR) and putamen to caudate ratio (PCR) were compared between subjects who underwent 123I‐FP‐CIT SPECT/CT and 18F‐FP‐CIT PET/CT. Visual analysis showed that the striatal uptake of both radiotracers was decreased in the PD group, whereas striatal uptake was intact in the ET group. The SBR between 123I‐FP‐CIT SPECT/CT and 18F‐FP‐CIT PET/CT showed a positive correlation (r = .78, p < .01). However, the mean SBRs on 18F‐FP‐CIT PET/CT were higher than those on 123I‐FP‐CIT SPECT/CT (2.19 ± .87 and 1.22 ± .49, respectively; p < .01). The PCRs in these two modalities were correlated with each other (r = .71, p < .01). The mean PCRs on 18F‐FP‐CIT PET/CT were not significantly higher than those on 123I‐FP‐CIT SPECT/CT (1.31 ± .19 and 0.98 ± .06, respectively; p = .06). These preliminary results indicate that the uptake of both 123I‐FP‐CIT and 18F‐FP‐CIT was decreased in the PD group when compared with the ET controls. Visual analyses using both methods did not affect the diagnostic accuracy in this study. However, semiquantitative analysis indicated a better contrast of 18F‐FP‐CIT PET/CT relative to 123I‐FP‐CIT SPECT/CT.
Head‐to‐head comparison of 18F‐FP‐CIT and 123I‐FP‐CIT for dopamine transporter imaging in patients with Parkinson's disease: A preliminary study
123I‐FP‐CIT and 18F‐FP‐CIT are radiotracers which are widely used to diagnose Parkinson's disease (PD). However, to our knowledge, no studies to date have made head‐to‐head comparisons between 123I‐FP‐CIT and 18F‐FP‐CIT. Therefore, in this study, 123I‐FP‐CIT SPECT/CT was compared with 18F‐FP‐CIT PET/CT in the same cohort of subjects. Patients with PD and essential tremor (ET) underwent 123I‐FP‐CIT SPECT/CT and 18F‐FP‐CIT PET/CT. Visual and semiquantitative analyses were conducted. The specific binding ratio (SBR) and putamen to caudate ratio (PCR) were compared between subjects who underwent 123I‐FP‐CIT SPECT/CT and 18F‐FP‐CIT PET/CT. Visual analysis showed that the striatal uptake of both radiotracers was decreased in the PD group, whereas striatal uptake was intact in the ET group. The SBR between 123I‐FP‐CIT SPECT/CT and 18F‐FP‐CIT PET/CT showed a positive correlation (r = .78, p < .01). However, the mean SBRs on 18F‐FP‐CIT PET/CT were higher than those on 123I‐FP‐CIT SPECT/CT (2.19 ± .87 and 1.22 ± .49, respectively; p < .01). The PCRs in these two modalities were correlated with each other (r = .71, p < .01). The mean PCRs on 18F‐FP‐CIT PET/CT were not significantly higher than those on 123I‐FP‐CIT SPECT/CT (1.31 ± .19 and 0.98 ± .06, respectively; p = .06). These preliminary results indicate that the uptake of both 123I‐FP‐CIT and 18F‐FP‐CIT was decreased in the PD group when compared with the ET controls. Visual analyses using both methods did not affect the diagnostic accuracy in this study. However, semiquantitative analysis indicated a better contrast of 18F‐FP‐CIT PET/CT relative to 123I‐FP‐CIT SPECT/CT.