Dui Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dui Liu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Xiaohua Li
School of Electric Power Engineering, South China University of Technology, Guangzhou 510643, China
2 shared publications - Zexiang Cai
South China University of Technology
2 shared publications Bing Lin
1 shared publication- Bing Lin
College of Physics and Energy, Fujian Normal University, Fuzhou, China
1 shared publication Changqing Zou
1 shared publicationHongjie Yu
Fujian Normal University
1 shared publication
Latest Publications
- 4 March 2026
- Published by Elsevier in Applied Soft Computing
- Vol. 194
Hierarchical and asynchronous dynamic hypergraph network for stock trend prediction
- 4 March 2026
- Published by Elsevier in Applied Soft Computing
- Vol. 194
Hierarchical and asynchronous dynamic hypergraph network for stock trend prediction
- 13 May 2023
- Published by Springer Nature
- p. 320-334
Container-Driven Scheduling Strategy for Scientific Workflows in Multi-vCPU Environments
- 13 May 2023
- Published by Springer Nature
- p. 320-334
Container-Driven Scheduling Strategy for Scientific Workflows in Multi-vCPU Environments
- 18 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3447-3457
Real-Time Virtual Measurement Technique for the Thyristor Valve Current Based on the Converter Terminal Current
The safety of converters is key to the stable operation of AC/DC hybrid power grids after AC faults. Thyristor valve current is a direct manifestation of the converter observability, but there are no measuring elements inside the converter, so the thyristor valve current can be reflected only indirectly through external electrical quantities. This paper proposes a virtual measurement scheme based on the temporal features of the converter terminal current. First, under the action of the trigger pulse, the polarity characteristics of the AC current and temporal features between the valves are utilized to predictive estimate the valve state. Then, when commutation failures occur and the bypass paths form, the conduction state of valve is constructed based on the relationship between AC and DC current. Last, when the valve is to be shut-off in the bypass path, the blocking state of the valve is corrected based on the unidirectional conductance characteristics of the valve. According to the above analysis, combined with the topological current equation of the converter, the valve current can be calculated in the whole process. Through the simulation of the different valve states and bypass paths and analysis of the field record data, the results show that the valve current can still be accurately calculated based on the virtual measurement scheme.
- 18 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3447-3457
Real-Time Virtual Measurement Technique for the Thyristor Valve Current Based on the Converter Terminal Current
The safety of converters is key to the stable operation of AC/DC hybrid power grids after AC faults. Thyristor valve current is a direct manifestation of the converter observability, but there are no measuring elements inside the converter, so the thyristor valve current can be reflected only indirectly through external electrical quantities. This paper proposes a virtual measurement scheme based on the temporal features of the converter terminal current. First, under the action of the trigger pulse, the polarity characteristics of the AC current and temporal features between the valves are utilized to predictive estimate the valve state. Then, when commutation failures occur and the bypass paths form, the conduction state of valve is constructed based on the relationship between AC and DC current. Last, when the valve is to be shut-off in the bypass path, the blocking state of the valve is corrected based on the unidirectional conductance characteristics of the valve. According to the above analysis, combined with the topological current equation of the converter, the valve current can be calculated in the whole process. Through the simulation of the different valve states and bypass paths and analysis of the field record data, the results show that the valve current can still be accurately calculated based on the virtual measurement scheme.
- Open Access
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 8922-8934
Analysis of the Harmonic Transmission Characteristics of HVDC Transmission Based on a Unified Port Theory Model
The application of power electronics can introduce flexibility into power systems, but it can also cause harmonic problems. As a typical application of power electronics, high-voltage direct current (HVDC) transmission exhibits very prominent harmonic problems. In recent years, many HVDC protection maloperation events caused by harmonic problems have occurred in the field. The phenomena of harmonic transfer and amplification in HVDC transmission have an undeniable impact on the overall operation of a power system. Previous studies of these phenomena have relied mainly on detailed electromagnetic transient simulations. However, these simulations normally suffer from a large computational burden and low efficiency due to the complexity of the models and the small simulation time steps used. Therefore, an efficient analysis model of harmonics for various HVDC operating modes is presented in this paper. This model is based on port theory; every part of the HVDC transmission system is represented by an equivalent two-port component to construct a unified equivalent circuit. The proposed model is simple to calculate, and only the connections of the two-port components need to be changed to model different operation modes. The proposed two-port model is applied for the harmonic analysis of an HVDC transmission system, and the validity and accuracy of the model are confirmed by detailed electromagnetic simulations. Moreover, the model can be easily applied to HVDC systems for harmonic transfer and amplification, and the effects of the HVDC transmission power and smoothing reactor on harmonic transfer and amplification are analyzed.
- 1 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 8922-8934
Open AccessAnalysis of the Harmonic Transmission Characteristics of HVDC Transmission Based on a Unified Port Theory Model
The application of power electronics can introduce flexibility into power systems, but it can also cause harmonic problems. As a typical application of power electronics, high-voltage direct current (HVDC) transmission exhibits very prominent harmonic problems. In recent years, many HVDC protection maloperation events caused by harmonic problems have occurred in the field. The phenomena of harmonic transfer and amplification in HVDC transmission have an undeniable impact on the overall operation of a power system. Previous studies of these phenomena have relied mainly on detailed electromagnetic transient simulations. However, these simulations normally suffer from a large computational burden and low efficiency due to the complexity of the models and the small simulation time steps used. Therefore, an efficient analysis model of harmonics for various HVDC operating modes is presented in this paper. This model is based on port theory; every part of the HVDC transmission system is represented by an equivalent two-port component to construct a unified equivalent circuit. The proposed model is simple to calculate, and only the connections of the two-port components need to be changed to model different operation modes. The proposed two-port model is applied for the harmonic analysis of an HVDC transmission system, and the validity and accuracy of the model are confirmed by detailed electromagnetic simulations. Moreover, the model can be easily applied to HVDC systems for harmonic transfer and amplification, and the effects of the HVDC transmission power and smoothing reactor on harmonic transfer and amplification are analyzed.