Luis Lopes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Luis Lopes has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Fonte
LIP -Laboratory of Instrumentation and Experimental Particle Physics Open Air Coimbra Portugal
93 shared publications - Alberto Blanco
Laboratory of Instrumentation and Experimental Particle Physics (LIP)
75 shared publications - Alessio Mangiarotti
Instituto de Física da Universidade de São Paulo, Rua do Matão 1371, 05508-090 São Paulo, Brazil
50 shared publications - Daniel Belver
Univ. de Santiago de Compostela
48 shared publications - Pablo Cabanelas
Instituto Galego de Física de Altas Enerxías University of Santiago de Compostela E-15782 Santiago de Compostela Spain
48 shared publications M. Traxler
GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany
47 shared publications
Latest Publications
- Open Access
- 10 November 2026
- Published by Elsevier in Zeitschrift für Medizinische Physik
Feasibility study of a new type of particle tracker for beam range determination by observation of charged secondary particles emitted perpendicularly from a carbon hadrontherapy beam at energies from 140 to 430 MeV/u
- 10 November 2026
- Published by Elsevier in Zeitschrift für Medizinische Physik
Open AccessFeasibility study of a new type of particle tracker for beam range determination by observation of charged secondary particles emitted perpendicularly from a carbon hadrontherapy beam at energies from 140 to 430 MeV/u
- Open Access
- 17 July 2026
- Published by Frontiers Media SA in Frontiers in Detector Science and Technology
- Vol. 4, 1864641
Sealed (zero gas flow) RPCs — a new operational paradigm for gaseous detectors
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in High Energy Physics due to their excellent timing performance, high efficiency, scalability, and affordability. However, their operation relies on gas mixtures based on hydrofluorocarbons (HFCs), whose high Global Warming Potential and progressive phase-out under current environmental regulations pose significant challenges for the long-term sustainability of RPC technology. In this work, we investigate a conceptually different approach, as an alternative to eco gas-mixture substitution strategies, based on sealed RPCs, in which the detector is filled with standard gas during assembly and subsequently hermetically sealed, allowing operation without any external gas supply. This approach drastically reduces gas consumption, eliminates the need for complex gas systems, and offers a potential solution compatible with both environmental constraints and high-performance operation. Two sealed RPC configurations, with active areas of approximately 0.1 m 2 and 1 m 2 , have been developed and characterized using atmospheric cosmic muons. The 0.1 m 2 module demonstrates stable operation over an extended period of nearly two continuous years, with an average efficiency of about 98% and low streamer probability. The 1 m 2 prototype exhibits a comparable initial response, although limitations related to mechanical stability are observed. These results demonstrate the feasibility of sealed RPC technology for trigger applications and highlight its potential as a robust, cost-effective, and environmentally sustainable alternative for future gaseous detector systems.
- 17 July 2026
- Published by Frontiers Media SA in Frontiers in Detector Science and Technology
- Vol. 4, 1864641
Open AccessSealed (zero gas flow) RPCs — a new operational paradigm for gaseous detectors
Resistive Plate Chambers (RPCs) are gaseous detectors widely used in High Energy Physics due to their excellent timing performance, high efficiency, scalability, and affordability. However, their operation relies on gas mixtures based on hydrofluorocarbons (HFCs), whose high Global Warming Potential and progressive phase-out under current environmental regulations pose significant challenges for the long-term sustainability of RPC technology. In this work, we investigate a conceptually different approach, as an alternative to eco gas-mixture substitution strategies, based on sealed RPCs, in which the detector is filled with standard gas during assembly and subsequently hermetically sealed, allowing operation without any external gas supply. This approach drastically reduces gas consumption, eliminates the need for complex gas systems, and offers a potential solution compatible with both environmental constraints and high-performance operation. Two sealed RPC configurations, with active areas of approximately 0.1 m 2 and 1 m 2 , have been developed and characterized using atmospheric cosmic muons. The 0.1 m 2 module demonstrates stable operation over an extended period of nearly two continuous years, with an average efficiency of about 98% and low streamer probability. The 1 m 2 prototype exhibits a comparable initial response, although limitations related to mechanical stability are observed. These results demonstrate the feasibility of sealed RPC technology for trigger applications and highlight its potential as a robust, cost-effective, and environmentally sustainable alternative for future gaseous detector systems.
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06040
Long-term monitoring of the optical performance of the primary mirrors at the Coihueco and Loma Amarilla sites of the Pierre Auger Observatory
This paper presents the results of an optical performance monitoring campaign for the primary mirrors installed in fluorescence telescopes at the Coihueco and Loma Amarilla sites at the Pierre Auger Observatory in Argentina. Since the end of 2003, this effort has developed into a unique long-term dataset that addresses the performance of the primary mirrors. We have focused on the scattering characteristics and specular reflectance of mirror segments, as well as their evolution over several years of operation. Despite being housed in climate-controlled buildings, dust accumulation, impurities, and natural aging — such as oxidation or other chemical or physical degradation processes — gradually deteriorate the specular reflectivity of the mirror segments. In this paper, we summarize data collected over eight years of fluorescence telescope operation since the last major cleaning in autumn 2016. During this period, periodic in situ measurements were performed of scattering characteristics using two techniques: (1) specular and diffuse reflectance measurements at a wavelength of 670 nm using a portable scatterometer, and (2) spectral reflectance measurements in the range from 300 nm to 700 nm using an integrating sphere and a spectrometer. This study builds upon a previous monitoring campaign conducted between 2012 and 2017. The measurements show that the primary mirrors remain in acceptable condition after more than 20 years of operation.
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , P06040
Open AccessLong-term monitoring of the optical performance of the primary mirrors at the Coihueco and Loma Amarilla sites of the Pierre Auger Observatory
This paper presents the results of an optical performance monitoring campaign for the primary mirrors installed in fluorescence telescopes at the Coihueco and Loma Amarilla sites at the Pierre Auger Observatory in Argentina. Since the end of 2003, this effort has developed into a unique long-term dataset that addresses the performance of the primary mirrors. We have focused on the scattering characteristics and specular reflectance of mirror segments, as well as their evolution over several years of operation. Despite being housed in climate-controlled buildings, dust accumulation, impurities, and natural aging — such as oxidation or other chemical or physical degradation processes — gradually deteriorate the specular reflectivity of the mirror segments. In this paper, we summarize data collected over eight years of fluorescence telescope operation since the last major cleaning in autumn 2016. During this period, periodic in situ measurements were performed of scattering characteristics using two techniques: (1) specular and diffuse reflectance measurements at a wavelength of 670 nm using a portable scatterometer, and (2) spectral reflectance measurements in the range from 300 nm to 700 nm using an integrating sphere and a spectrometer. This study builds upon a previous monitoring campaign conducted between 2012 and 2017. The measurements show that the primary mirrors remain in acceptable condition after more than 20 years of operation.
- Open Access
- 2 March 2026
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 999 (2) , 168
Search for Ultra-high-energy Neutrons from Galactic Sources with the Pierre Auger Observatory
Deflections in the propagation of charged ultra-high-energy cosmic rays (UHECRs) caused by magnetic fields make the identification of their sources challenging. On the other hand, the arrival directions at Earth of neutrons point directly to their origin. The emission of UHECRs from a source is expected to be accompanied by the production of neutrons in its vicinity through interactions with ambient matter and radiation. Since free neutrons travel a mean distance d kpc −1 = 9.2 ( E EeV −1 ) before decaying, a neutron flux in the EeV range could be detected on Earth from sources of UHECRs in our Galaxy. Using cosmic-ray data from Phase I of the Surface Detector of the Pierre Auger Observatory, we search for neutron fluxes from Galactic candidate sources. We select more than 1000 objects of astrophysical interest, stacking them into target sets. The targets all have decl. within the exposure of the Observatory, ranging from −90° up to +45° for energies above 1 EeV (and up to +20° for energies down to 0.1 EeV). Given that a neutron air shower is indistinguishable from a proton one, there is a significant background due to cosmic rays. A neutron flux from the direction of a candidate source would be identified by a celestial density of events that significantly exceeds the expected density of cosmic rays for that direction. No significant excess is found at any tested target direction, and an upper limit on the neutron flux is calculated for each candidate source.
- 2 March 2026
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 999 (2) , 168
Open AccessSearch for Ultra-high-energy Neutrons from Galactic Sources with the Pierre Auger Observatory
Deflections in the propagation of charged ultra-high-energy cosmic rays (UHECRs) caused by magnetic fields make the identification of their sources challenging. On the other hand, the arrival directions at Earth of neutrons point directly to their origin. The emission of UHECRs from a source is expected to be accompanied by the production of neutrons in its vicinity through interactions with ambient matter and radiation. Since free neutrons travel a mean distance d kpc −1 = 9.2 ( E EeV −1 ) before decaying, a neutron flux in the EeV range could be detected on Earth from sources of UHECRs in our Galaxy. Using cosmic-ray data from Phase I of the Surface Detector of the Pierre Auger Observatory, we search for neutron fluxes from Galactic candidate sources. We select more than 1000 objects of astrophysical interest, stacking them into target sets. The targets all have decl. within the exposure of the Observatory, ranging from −90° up to +45° for energies above 1 EeV (and up to +20° for energies down to 0.1 EeV). Given that a neutron air shower is indistinguishable from a proton one, there is a significant background due to cosmic rays. A neutron flux from the direction of a candidate source would be identified by a celestial density of events that significantly exceeds the expected density of cosmic rays for that direction. No significant excess is found at any tested target direction, and an upper limit on the neutron flux is calculated for each candidate source.
- Open Access
Search for ultra-high energy neutrons from Galactic sources with the Pierre Auger Observatory
Deflections in the propagation of charged ultra-high-energy cosmic rays (UHECRs) caused by magnetic fields make the identification of their sources challenging. On the other hand, the arrival directions at Earth of neutrons point directly to their origin. The emission of UHECRs from a source is expected to be accompanied by the production of neutrons in its vicinity through interactions with ambient matter and radiation. Since free neutrons travel a mean distance $d/\text{kpc}=9.2(E/\text{EeV})$ before decaying, a neutron flux in the EeV range could be detected on Earth from sources of UHECRs in our Galaxy. Using cosmic-ray data from the Phase\,I of the Surface Detector of the Pierre Auger Observatory, we search for neutron fluxes from Galactic candidate sources. We select more than 1000 objects of astrophysical interest, stacking them into target sets. The targets all have declinations within the exposure of the Observatory, ranging from $-90^\circ$ up to $+45^\circ$ for energies above 1 EeV (and up to $+20^\circ$ for energies down to 0.1 EeV). Given that a neutron air shower is indistinguishable from a proton one, there is a significant background due to cosmic rays. A neutron flux from the direction of a candidate source would be identified by a celestial density of events that significantly exceeds the expected density of cosmic rays for that direction. No significant excess is found at any tested target direction, and an upper limit on the neutron flux is calculated for each candidate source.Open AccessSearch for ultra-high energy neutrons from Galactic sources with the Pierre Auger Observatory
Deflections in the propagation of charged ultra-high-energy cosmic rays (UHECRs) caused by magnetic fields make the identification of their sources challenging. On the other hand, the arrival directions at Earth of neutrons point directly to their origin. The emission of UHECRs from a source is expected to be accompanied by the production of neutrons in its vicinity through interactions with ambient matter and radiation. Since free neutrons travel a mean distance $d/\text{kpc}=9.2(E/\text{EeV})$ before decaying, a neutron flux in the EeV range could be detected on Earth from sources of UHECRs in our Galaxy. Using cosmic-ray data from the Phase\,I of the Surface Detector of the Pierre Auger Observatory, we search for neutron fluxes from Galactic candidate sources. We select more than 1000 objects of astrophysical interest, stacking them into target sets. The targets all have declinations within the exposure of the Observatory, ranging from $-90^\circ$ up to $+45^\circ$ for energies above 1 EeV (and up to $+20^\circ$ for energies down to 0.1 EeV). Given that a neutron air shower is indistinguishable from a proton one, there is a significant background due to cosmic rays. A neutron flux from the direction of a candidate source would be identified by a celestial density of events that significantly exceeds the expected density of cosmic rays for that direction. No significant excess is found at any tested target direction, and an upper limit on the neutron flux is calculated for each candidate source. - Open Access
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10039
Studies of hadronic showers in SND@LHC
The SND@LHC experiment was built for observing neutrinos arising from LHC pp collisions. The detector consists of two sections: a target instrumented with SciFi modules and a hadronic calorimeter/muon detector. Energetic νN collisions in the target produce hadronic showers. Reconstruction of the shower total energy requires an estimate of the fractions deposited in both the target and the calorimeter. In order to calibrate the SND@LHC response, a replica of the detector was exposed to hadron beams with 100 to 300 GeV in the CERN SPS H8 test beam line in Summer 2023. This report describes the methods developed to tag the presence of a shower, to locate the shower origin in the target, and to combine the target SciFi and the calorimeter signals so to measure the shower total energy.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10039
Open AccessStudies of hadronic showers in SND@LHC
The SND@LHC experiment was built for observing neutrinos arising from LHC pp collisions. The detector consists of two sections: a target instrumented with SciFi modules and a hadronic calorimeter/muon detector. Energetic νN collisions in the target produce hadronic showers. Reconstruction of the shower total energy requires an estimate of the fractions deposited in both the target and the calorimeter. In order to calibrate the SND@LHC response, a replica of the detector was exposed to hadron beams with 100 to 300 GeV in the CERN SPS H8 test beam line in Summer 2023. This report describes the methods developed to tag the presence of a shower, to locate the shower origin in the target, and to combine the target SciFi and the calorimeter signals so to measure the shower total energy.
- Open Access
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , P07011
Installation and performance of the 3rd Veto plane at the SND@LHC detector
During 2022/2023 the optimal inefficiency of the Veto system of the SND@LHC detector was measured to be (7.8 ± 2.8) × 10-8. To reduce this inefficiency, a third Veto plane was installed during the 2023-2024 Year End Technical Stop. In addition, the Veto system was lowered to cover the target fully, thereby increasing acceptance. This paper describes how the inefficiency of the Veto system was reduced from (7.8 ± 2.8) × 10-8 with an acceptance of about 64% of the target area in 2022-2023 to (4.9 ± 1.9) × 10-9 on the full area in 2024.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , P07011
Open AccessInstallation and performance of the 3rd Veto plane at the SND@LHC detector
During 2022/2023 the optimal inefficiency of the Veto system of the SND@LHC detector was measured to be (7.8 ± 2.8) × 10-8. To reduce this inefficiency, a third Veto plane was installed during the 2023-2024 Year End Technical Stop. In addition, the Veto system was lowered to cover the target fully, thereby increasing acceptance. This paper describes how the inefficiency of the Veto system was reduced from (7.8 ± 2.8) × 10-8 with an acceptance of about 64% of the target area in 2022-2023 to (4.9 ± 1.9) × 10-9 on the full area in 2024.
- Open Access
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1916-1926
Development and Assessment of a New Multichannel Electrocutaneous Device for Non-Invasive Somatosensory Stimulation for Magnetic Resonance Applications
Non-invasive electrocutaneous stimulation, which applies an electrical current flowing through the skin’s surface to elicit a tactile percept, can be used in combination with functional magnetic resonance imaging (fMRI) to obtain somatotopic maps that illustrate the spatial patterns and functional organization of the primary somatosensory cortex (S1). However, accessibility to this technique, combined with fMRI, is limited, especially for applications requiring multiple stimulation channels. This study presents the development and assessment of a novel multichannel electrocutaneous stimulation device designed for non-invasive somatosensory stimulation of the upper limbs in human participants within a magnetic resonance (MR) environment. The current-controlled, voltage-limited stimulation device features 20 stimulation channels that can be individually configured to deliver various non-simultaneous combinations of personalized electrical pulses, tailored to the subject, stimulation site, and paradigm. It was designed with a modular assembly to ensure compatibility with the MR environment. The assessment of the device consisted of four stages. First, the feasibility of generating controllable electrical stimuli outside the MR environment was validated using an electrical circuit equivalent to the impedance of the human body and the electrode-skin interface. Subsequently, safety and compatibility were evaluated in a 3 Tesla Magnetom Prisma fit scanner using a phantom. Next, the device's capacity to generate perceptible tactile sensations and user acceptability were assessed by testing the device on a single participant outside the MR environment. Finally, structural and functional data were acquired from three participants during a somatosensory stimulation experiment as a proof of concept to confirm the brain activity elicited by stimulation. These assessments confirmed the device’s capacity to generate controllable electrical stimuli both outside and in the MR environment, its compatibility and safety in this MR environment, and its effectiveness in eliciting brain activity in the expected brain areas without causing any discomfort to the participant. This study paves the way for future research on somatotopic mapping of S1 using this device.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1916-1926
Open AccessDevelopment and Assessment of a New Multichannel Electrocutaneous Device for Non-Invasive Somatosensory Stimulation for Magnetic Resonance Applications
Non-invasive electrocutaneous stimulation, which applies an electrical current flowing through the skin’s surface to elicit a tactile percept, can be used in combination with functional magnetic resonance imaging (fMRI) to obtain somatotopic maps that illustrate the spatial patterns and functional organization of the primary somatosensory cortex (S1). However, accessibility to this technique, combined with fMRI, is limited, especially for applications requiring multiple stimulation channels. This study presents the development and assessment of a novel multichannel electrocutaneous stimulation device designed for non-invasive somatosensory stimulation of the upper limbs in human participants within a magnetic resonance (MR) environment. The current-controlled, voltage-limited stimulation device features 20 stimulation channels that can be individually configured to deliver various non-simultaneous combinations of personalized electrical pulses, tailored to the subject, stimulation site, and paradigm. It was designed with a modular assembly to ensure compatibility with the MR environment. The assessment of the device consisted of four stages. First, the feasibility of generating controllable electrical stimuli outside the MR environment was validated using an electrical circuit equivalent to the impedance of the human body and the electrode-skin interface. Subsequently, safety and compatibility were evaluated in a 3 Tesla Magnetom Prisma fit scanner using a phantom. Next, the device's capacity to generate perceptible tactile sensations and user acceptability were assessed by testing the device on a single participant outside the MR environment. Finally, structural and functional data were acquired from three participants during a somatosensory stimulation experiment as a proof of concept to confirm the brain activity elicited by stimulation. These assessments confirmed the device’s capacity to generate controllable electrical stimuli both outside and in the MR environment, its compatibility and safety in this MR environment, and its effectiveness in eliciting brain activity in the expected brain areas without causing any discomfort to the participant. This study paves the way for future research on somatotopic mapping of S1 using this device.