David Le
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Le has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Xincheng Yao
Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
12 shared publications - Taeyoon Son
Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
6 shared publications - Minhaj Nur Alam
Department of Electrical and Computer Engineering, University of North Carolina at Charlotte
4 shared publications - Behrouz Ebrahimi
Department of Biomedical Engineering, University of Illinois Chicago, Chicago, IL 60607, USA
3 shared publications Jennifer I. Lim
Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, USA
3 shared publicationsTaeyoon Son
Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, USA
3 shared publications
Latest Publications
- Open Access
- 18 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (07) , 076001-13
Assessing spectral effectiveness in color fundus photography for deep learning classification of retinopathy of prematurity
Retinopathy of prematurity (ROP) occurs in premature infants due to underdeveloped retinal vasculature at birth,1 causing abnormal blood vessel growth at the boundary of partially vascularized and avascular retinal areas.2,3 ROP is the leading preventable cause of childhood blindness worldwide.4,5 The severity of ROP is classified into five stages, corresponding to mild to severe stages.6 Appropriate detection and accurate ROP diagnosis in premature infants is crucial to prevent irreversible vision loss and associated visual developmental complications such as astigmatism, myopia, glaucoma, cataracts, anisometropia, amblyopia, strabismus, and retinal detachment.7,8
- 18 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (07) , 076001-13
Open AccessAssessing spectral effectiveness in color fundus photography for deep learning classification of retinopathy of prematurity
Retinopathy of prematurity (ROP) occurs in premature infants due to underdeveloped retinal vasculature at birth,1 causing abnormal blood vessel growth at the boundary of partially vascularized and avascular retinal areas.2,3 ROP is the leading preventable cause of childhood blindness worldwide.4,5 The severity of ROP is classified into five stages, corresponding to mild to severe stages.6 Appropriate detection and accurate ROP diagnosis in premature infants is crucial to prevent irreversible vision loss and associated visual developmental complications such as astigmatism, myopia, glaucoma, cataracts, anisometropia, amblyopia, strabismus, and retinal detachment.7,8
- Open Access
- 9 February 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-11
Deep learning-based optical coherence tomography angiography image construction using spatial vascular connectivity network
Optical coherence tomography angiography (OCTA) provides unrivaled capability for depth-resolved visualization of retinal vasculature at the microcapillary level resolution. For OCTA image construction, repeated OCT scans from one location are required to identify blood vessels with active blood flow. The requirement for multi-scan-volumetric OCT can reduce OCTA imaging speed, which will induce eye movements and limit the image field-of-view. In principle, the blood flow should also affect the reflectance brightness profile along the vessel direction in a single-scan-volumetric OCT. Here we report a spatial vascular connectivity network (SVC-Net) for deep learning OCTA construction from single-scan-volumetric OCT. We quantitatively determine the optimal number of neighboring B-scans as image input, we compare the effects of neighboring B-scans to single B-scan input models, and we explore different loss functions for optimization of SVC-Net. This approach can improve the clinical implementation of OCTA by improving transverse image resolution or increasing the field-of-view.
- 9 February 2024
- Published by Springer Nature in Communications Engineering
- Vol. 3 (1) , 1-11
Open AccessDeep learning-based optical coherence tomography angiography image construction using spatial vascular connectivity network
Optical coherence tomography angiography (OCTA) provides unrivaled capability for depth-resolved visualization of retinal vasculature at the microcapillary level resolution. For OCTA image construction, repeated OCT scans from one location are required to identify blood vessels with active blood flow. The requirement for multi-scan-volumetric OCT can reduce OCTA imaging speed, which will induce eye movements and limit the image field-of-view. In principle, the blood flow should also affect the reflectance brightness profile along the vessel direction in a single-scan-volumetric OCT. Here we report a spatial vascular connectivity network (SVC-Net) for deep learning OCTA construction from single-scan-volumetric OCT. We quantitatively determine the optimal number of neighboring B-scans as image input, we compare the effects of neighboring B-scans to single B-scan input models, and we explore different loss functions for optimization of SVC-Net. This approach can improve the clinical implementation of OCTA by improving transverse image resolution or increasing the field-of-view.
- 1 June 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (6) , 992-998
COMPARATIVE ANALYSIS OF OCT AND OCT ANGIOGRAPHY CHARACTERISTICS IN EARLY DIABETIC RETINOPATHY
Purpose: To assess the quantitative characteristics of optical coherence tomography (OCT) and OCT angiography (OCTA) for the objective detection of early diabetic retinopathy (DR). Methods: This was a retrospective and cross-sectional study, which was carried out at a tertiary academic practice with a subspecialty. Twenty control participants, 15 people with diabetics without retinopathy (NoDR), and 22 people with mild nonproliferative diabetic retinopathy (NPDR) were included in this study. Quantitative OCT characteristics were derived from the photoreceptor hyperreflective bands, i.e., inner segment ellipsoid (ISe) and retinal pigment epithelium (RPE). OCTA characteristics, including vessel diameter index (VDI), vessel perimeter index (VPI), and vessel skeleton density (VSD), were evaluated. Results: Quantitative OCT analysis indicated that the ISe intensity was significantly trending downward with DR advancement. Comparative OCTA revealed VDI, VPI, and VSD as the most sensitive characteristics of DR. Correlation analysis of OCT and OCTA characteristics revealed weak variable correlation between the two imaging modalities. Conclusion: Quantitative OCT and OCTA analyses revealed photoreceptor and vascular distortions in early DR. Comparative analysis revealed that the OCT intensity ratio, ISe/RPE, has the best sensitivity for early DR detection. Weak variable correlation of the OCT and OCTA characteristics suggests that OCT and OCTA are providing supplementary information for DR detection and classification.
- 1 June 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (6) , 992-998
COMPARATIVE ANALYSIS OF OCT AND OCT ANGIOGRAPHY CHARACTERISTICS IN EARLY DIABETIC RETINOPATHY
Purpose: To assess the quantitative characteristics of optical coherence tomography (OCT) and OCT angiography (OCTA) for the objective detection of early diabetic retinopathy (DR). Methods: This was a retrospective and cross-sectional study, which was carried out at a tertiary academic practice with a subspecialty. Twenty control participants, 15 people with diabetics without retinopathy (NoDR), and 22 people with mild nonproliferative diabetic retinopathy (NPDR) were included in this study. Quantitative OCT characteristics were derived from the photoreceptor hyperreflective bands, i.e., inner segment ellipsoid (ISe) and retinal pigment epithelium (RPE). OCTA characteristics, including vessel diameter index (VDI), vessel perimeter index (VPI), and vessel skeleton density (VSD), were evaluated. Results: Quantitative OCT analysis indicated that the ISe intensity was significantly trending downward with DR advancement. Comparative OCTA revealed VDI, VPI, and VSD as the most sensitive characteristics of DR. Correlation analysis of OCT and OCTA characteristics revealed weak variable correlation between the two imaging modalities. Conclusion: Quantitative OCT and OCTA analyses revealed photoreceptor and vascular distortions in early DR. Comparative analysis revealed that the OCT intensity ratio, ISe/RPE, has the best sensitivity for early DR detection. Weak variable correlation of the OCT and OCTA characteristics suggests that OCT and OCTA are providing supplementary information for DR detection and classification.
- 1 May 2023
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 248 (9) , 747-761
Deep learning for artery–vein classification in optical coherence tomography angiography
Major retinopathies can differentially impact the arteries and veins. Traditional fundus photography provides limited resolution for visualizing retinal vascular details. Optical coherence tomography (OCT) can provide improved resolution for retinal imaging. However, it cannot discern capillary-level structures due to the limited image contrast. As a functional extension of OCT modality, optical coherence tomography angiography (OCTA) is a non-invasive, label-free method for enhanced contrast visualization of retinal vasculatures at the capillary level. Recently differential artery–vein (AV) analysis in OCTA has been demonstrated to improve the sensitivity for staging of retinopathies. Therefore, AV classification is an essential step for disease detection and diagnosis. However, current methods for AV classification in OCTA have employed multiple imagers, that is, fundus photography and OCT, and complex algorithms, thereby making it difficult for clinical deployment. On the contrary, deep learning (DL) algorithms may be able to reduce computational complexity and automate AV classification. In this article, we summarize traditional AV classification methods, recent DL methods for AV classification in OCTA, and discuss methods for interpretability in DL models.
- 1 May 2023
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 248 (9) , 747-761
Deep learning for artery–vein classification in optical coherence tomography angiography
Major retinopathies can differentially impact the arteries and veins. Traditional fundus photography provides limited resolution for visualizing retinal vascular details. Optical coherence tomography (OCT) can provide improved resolution for retinal imaging. However, it cannot discern capillary-level structures due to the limited image contrast. As a functional extension of OCT modality, optical coherence tomography angiography (OCTA) is a non-invasive, label-free method for enhanced contrast visualization of retinal vasculatures at the capillary level. Recently differential artery–vein (AV) analysis in OCTA has been demonstrated to improve the sensitivity for staging of retinopathies. Therefore, AV classification is an essential step for disease detection and diagnosis. However, current methods for AV classification in OCTA have employed multiple imagers, that is, fundus photography and OCT, and complex algorithms, thereby making it difficult for clinical deployment. On the contrary, deep learning (DL) algorithms may be able to reduce computational complexity and automate AV classification. In this article, we summarize traditional AV classification methods, recent DL methods for AV classification in OCTA, and discuss methods for interpretability in DL models.
- 1 August 2022
- Published by Wolters Kluwer Health in Retina
- Vol. 42 (8) , 1442-1449
QUANTITATIVE OPTICAL COHERENCE TOMOGRAPHY REVEALS ROD PHOTORECEPTOR DEGENERATION in EARLY DIABETIC RETINOPATHY
Purpose: This study is to test the feasibility of optical coherence tomography (OCT) detection of photoreceptor abnormality and to verify that the photoreceptor abnormality is rod predominated in early diabetic retinopathy (DR). Methods: OCT images were acquired from normal eyes, diabetic eyes with no DR, and mild nonproliferative DR (NPDR). Quantitative features, including thickness measurements quantifying band distances and reflectance intensity features among the external limiting membrane, inner segment ellipsoid, interdigitation zone, and retinal pigment epithelium were determined. Comparative OCT analysis of central fovea, parafovea, and perifovea were implemented to verify that the photoreceptor abnormality is rod predominated in early DR. Results: Thickness abnormalities between the inner segment ellipsoid and interdigitation zone also showed a decreasing trend among cohorts. Reflectance abnormalities of the external limiting membrane, interdigitation zone, and inner segment ellipsoid were observed between healthy, no DR, and mild NPDR eyes. The normalized inner segment ellipsoid/retinal pigment epithelium intensity ratio revealed a significant decreasing trend in the perifovea, but no detectable difference in central fovea. Conclusion: Quantitative OCT analysis consistently revealed outer retina, i.e., photoreceptor changes in diabetic patients with no DR and mild NPDR. Comparative analysis of central fovea, parafovea, and perifovea confirmed that the photoreceptor abnormality is rod-predominated in early DR.
- 1 August 2022
- Published by Wolters Kluwer Health in Retina
- Vol. 42 (8) , 1442-1449
QUANTITATIVE OPTICAL COHERENCE TOMOGRAPHY REVEALS ROD PHOTORECEPTOR DEGENERATION in EARLY DIABETIC RETINOPATHY
Purpose: This study is to test the feasibility of optical coherence tomography (OCT) detection of photoreceptor abnormality and to verify that the photoreceptor abnormality is rod predominated in early diabetic retinopathy (DR). Methods: OCT images were acquired from normal eyes, diabetic eyes with no DR, and mild nonproliferative DR (NPDR). Quantitative features, including thickness measurements quantifying band distances and reflectance intensity features among the external limiting membrane, inner segment ellipsoid, interdigitation zone, and retinal pigment epithelium were determined. Comparative OCT analysis of central fovea, parafovea, and perifovea were implemented to verify that the photoreceptor abnormality is rod predominated in early DR. Results: Thickness abnormalities between the inner segment ellipsoid and interdigitation zone also showed a decreasing trend among cohorts. Reflectance abnormalities of the external limiting membrane, interdigitation zone, and inner segment ellipsoid were observed between healthy, no DR, and mild NPDR eyes. The normalized inner segment ellipsoid/retinal pigment epithelium intensity ratio revealed a significant decreasing trend in the perifovea, but no detectable difference in central fovea. Conclusion: Quantitative OCT analysis consistently revealed outer retina, i.e., photoreceptor changes in diabetic patients with no DR and mild NPDR. Comparative analysis of central fovea, parafovea, and perifovea confirmed that the photoreceptor abnormality is rod-predominated in early DR.
- Open Access
ADC-Net: An Open-Source Deep Learning Network for Automated Dispersion Compensation in Optical Coherence Tomography
Chromatic dispersion is a common problem to degrade the system resolution in optical coherence tomography (OCT). This study is to develop a deep learning network for automated dispersion compensation (ADC-Net) in OCT. The ADC-Net is based on a redesigned UNet architecture which employs an encoder-decoder pipeline. The input section encompasses partially compensated OCT B-scans with individual retinal layers optimized. Corresponding output is a fully compensated OCT B-scans with all retinal layers optimized. Two numeric parameters, i.e., peak signal to noise ratio (PSNR) and structural similarity index metric computed at multiple scales (MS-SSIM), were used for objective assessment of the ADC-Net performance. Comparative analysis of training models, including single, three, five, seven and nine input channels were implemented. The five-input channels implementation was observed as the optimal mode for ADC-Net training to achieve robust dispersion compensation in OCT
Open AccessADC-Net: An Open-Source Deep Learning Network for Automated Dispersion Compensation in Optical Coherence Tomography
Chromatic dispersion is a common problem to degrade the system resolution in optical coherence tomography (OCT). This study is to develop a deep learning network for automated dispersion compensation (ADC-Net) in OCT. The ADC-Net is based on a redesigned UNet architecture which employs an encoder-decoder pipeline. The input section encompasses partially compensated OCT B-scans with individual retinal layers optimized. Corresponding output is a fully compensated OCT B-scans with all retinal layers optimized. Two numeric parameters, i.e., peak signal to noise ratio (PSNR) and structural similarity index metric computed at multiple scales (MS-SSIM), were used for objective assessment of the ADC-Net performance. Comparative analysis of training models, including single, three, five, seven and nine input channels were implemented. The five-input channels implementation was observed as the optimal mode for ADC-Net training to achieve robust dispersion compensation in OCT
- 19 July 2021
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 246 (20) , 2170-2183
Machine learning in optical coherence tomography angiography
Optical coherence tomography angiography (OCTA) offers a noninvasive label-free solution for imaging retinal vasculatures at the capillary level resolution. In principle, improved resolution implies a better chance to reveal subtle microvascular distortions associated with eye diseases that are asymptomatic in early stages. However, massive screening requires experienced clinicians to manually examine retinal images, which may result in human error and hinder objective screening. Recently, quantitative OCTA features have been developed to standardize and document retinal vascular changes. The feasibility of using quantitative OCTA features for machine learning classification of different retinopathies has been demonstrated. Deep learning-based applications have also been explored for automatic OCTA image analysis and disease classification. In this article, we summarize recent developments of quantitative OCTA features, machine learning image analysis, and classification.
- 19 July 2021
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 246 (20) , 2170-2183
Machine learning in optical coherence tomography angiography
Optical coherence tomography angiography (OCTA) offers a noninvasive label-free solution for imaging retinal vasculatures at the capillary level resolution. In principle, improved resolution implies a better chance to reveal subtle microvascular distortions associated with eye diseases that are asymptomatic in early stages. However, massive screening requires experienced clinicians to manually examine retinal images, which may result in human error and hinder objective screening. Recently, quantitative OCTA features have been developed to standardize and document retinal vascular changes. The feasibility of using quantitative OCTA features for machine learning classification of different retinopathies has been demonstrated. Deep learning-based applications have also been explored for automatic OCTA image analysis and disease classification. In this article, we summarize recent developments of quantitative OCTA features, machine learning image analysis, and classification.
- 10 June 2021
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 246 (20) , 2140-2150
Interpretation of anatomic correlates of outer retinal bands in optical coherence tomography
By providing the sectioning capability to differentiate individual retinal layers, optical coherence tomography (OCT) is revolutionizing eye disease diagnosis and treatment evaluation. A better understanding of the hyper- and hypo-reflective bands in retinal OCT is essential for accurate interpretation of clinical outcomes. In this article, we summarize the interpretations of clinical OCT and adaptive optics (AO) OCT (AO-OCT) of the outer retina in the human eye, and briefly review OCT investigation of the outer retina in animal models. Quantitative analysis of outer retinal OCT bands is compared to established parameters of retinal histology. The literature review and comparative analysis support that both inner/outer segment (IS/OS) junction and IS ellipsoid zone nonexclusively contribute to the second band; and OS, OS tips, and retinal pigment epithelium apical processes contribute to the third band in conventional OCT. In contrast, AO-OCT might predominantly detect the IS/OS junction and OS tip signals at the second and third bands due to its improved sectioning capability and possible AO effect on the sensitivities for recording ballistic and diffusive photons from different regions of the outer retina.
- 10 June 2021
- Published by Frontiers Media SA in Experimental Biology and Medicine
- Vol. 246 (20) , 2140-2150
Interpretation of anatomic correlates of outer retinal bands in optical coherence tomography
By providing the sectioning capability to differentiate individual retinal layers, optical coherence tomography (OCT) is revolutionizing eye disease diagnosis and treatment evaluation. A better understanding of the hyper- and hypo-reflective bands in retinal OCT is essential for accurate interpretation of clinical outcomes. In this article, we summarize the interpretations of clinical OCT and adaptive optics (AO) OCT (AO-OCT) of the outer retina in the human eye, and briefly review OCT investigation of the outer retina in animal models. Quantitative analysis of outer retinal OCT bands is compared to established parameters of retinal histology. The literature review and comparative analysis support that both inner/outer segment (IS/OS) junction and IS ellipsoid zone nonexclusively contribute to the second band; and OS, OS tips, and retinal pigment epithelium apical processes contribute to the third band in conventional OCT. In contrast, AO-OCT might predominantly detect the IS/OS junction and OS tip signals at the second and third bands due to its improved sectioning capability and possible AO effect on the sensitivities for recording ballistic and diffusive photons from different regions of the outer retina.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 42
Deep learning artery-vein classification in OCT angiography
SPIE Digital Library Proceedings
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- p. 42
Deep learning artery-vein classification in OCT angiography
SPIE Digital Library Proceedings
- Open Access
- 1 March 2020
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 11 (3) , 1102-1119
Differential artery-vein analysis in quantitative retinal imaging: a review
Quantitative retinal imaging is essential for eye disease detection, staging classification, and treatment assessment. It is known that different eye diseases or severity stages can affect the artery and vein systems in different ways. Therefore, differential artery-vein (AV) analysis can improve the performance of quantitative retinal imaging. In this article, we provide a brief summary of technical rationales and clinical applications of differential AV analysis in fundus photography, optical coherence tomography (OCT), and OCT angiography (OCTA).
- 1 March 2020
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 11 (3) , 1102-1119
Open AccessDifferential artery-vein analysis in quantitative retinal imaging: a review
Quantitative retinal imaging is essential for eye disease detection, staging classification, and treatment assessment. It is known that different eye diseases or severity stages can affect the artery and vein systems in different ways. Therefore, differential artery-vein (AV) analysis can improve the performance of quantitative retinal imaging. In this article, we provide a brief summary of technical rationales and clinical applications of differential AV analysis in fundus photography, optical coherence tomography (OCT), and OCT angiography (OCTA).