Yanjun Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanjun Ding has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Donghai Li
State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
3 shared publications Peng Zhimin
State Key Laboratory of Power Systems, Dept of Thermal Engineering, Tsinghua University, Beijing 100084, China
3 shared publications- Zhimin Peng
Tsinghua University
3 shared publications Che Lu
State Key Laboratory of Power Systems, Dept of Thermal Engineering, Tsinghua University, Beijing 100084, China
2 shared publications- Gengjin Shi
State Key Lab of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
2 shared publications Zhimin Peng
State Key Laboratory of Power Systems, Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
2 shared publications
Latest Publications
- Open Access
Desired-Dynamics-Based Predictive Control (DDPC) for Uncertain Systems: A Unified Framework and Application to Superheated Steam Temperature Control
With the increasing prevalence of uncertainties and variability in modern energy systems, model predictive control (MPC) often faces the challenge of predictive model mismatch. This paper proposes a desired-dynamics-based predictive control (DDPC) framework, in which an inner shaping layer is introduced to transform the raw plant into a desired dynamic model for the outer MPC. A unified design methodology is developed, including equivalent-model construction, desired-dynamics selection, and two inner-layer realizations based on desired dynamic equation (DDE)-PID and active disturbance rejection control (ADRC). In this way, the prediction model used by MPC is no longer the original uncertain plant but an explicitly shaped equivalent model determined by inner-layer controller parameters. The proposed method is validated on linear and nonlinear benchmark plants, together with frequency-domain and Monte Carlo robustness analyses. Results show that DDPC improves disturbance-rejection ability and enhances robustness against model mismatch and parameter perturbations. Further evaluation on the superheated steam temperature loop of a high-fidelity 660 MW coal-fired boiler hardware-in-the-loop simulator shows that DDPC reduces the peak-to-peak temperature fluctuation from 22.88 °C to 11.39 °C in the deep peak shaving scenario, corresponding to a 50.2% reduction relative to standard MPC.
Open AccessDesired-Dynamics-Based Predictive Control (DDPC) for Uncertain Systems: A Unified Framework and Application to Superheated Steam Temperature Control
With the increasing prevalence of uncertainties and variability in modern energy systems, model predictive control (MPC) often faces the challenge of predictive model mismatch. This paper proposes a desired-dynamics-based predictive control (DDPC) framework, in which an inner shaping layer is introduced to transform the raw plant into a desired dynamic model for the outer MPC. A unified design methodology is developed, including equivalent-model construction, desired-dynamics selection, and two inner-layer realizations based on desired dynamic equation (DDE)-PID and active disturbance rejection control (ADRC). In this way, the prediction model used by MPC is no longer the original uncertain plant but an explicitly shaped equivalent model determined by inner-layer controller parameters. The proposed method is validated on linear and nonlinear benchmark plants, together with frequency-domain and Monte Carlo robustness analyses. Results show that DDPC improves disturbance-rejection ability and enhances robustness against model mismatch and parameter perturbations. Further evaluation on the superheated steam temperature loop of a high-fidelity 660 MW coal-fired boiler hardware-in-the-loop simulator shows that DDPC reduces the peak-to-peak temperature fluctuation from 22.88 °C to 11.39 °C in the deep peak shaving scenario, corresponding to a 50.2% reduction relative to standard MPC.
- 10 July 2022
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 123, 367-386
Review on recent progress in on-line monitoring technology for atmospheric pollution source emissions in China
- 10 July 2022
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 123, 367-386
Review on recent progress in on-line monitoring technology for atmospheric pollution source emissions in China
- Open Access
Research on the Desired Dynamic Selection of a Reference Model-Based PID Controller: A Case Study on a High-Pressure Heater in a 600 MW Power Plant
Nowadays, the proportional–integral–derivative (PID) controller dominates industrial process control. Because of the compromise between parameters, its tuning is still a challenge for practitioners. A reference model (RM)-based PID controller—the desired dynamic equational (DDE) PID controller—is regarded as a viable alternative since it can readily eliminate the compromise. However, how to design its desired dynamic equation remains an unsolved problem which limits the application of DDE PID controllers in large-scale industrial systems. Therefore, this paper studies the desired dynamic selection of DDE PID controllers and proposes a simple and practical selection procedure without using the accurate plant model. Simulations, experiments and filed tests demonstrate the convenience and advantages of the proposed method, thus making DDE PID an effective controller type which is specifically appealing to engineers. Moreover, the successful application of DDE PID controllers to a high-pressure (HP) heater in a coal-fired power plant shows their promising prospects in the future power industry with the increasing demand to integrate more renewables into the grid.
Open AccessResearch on the Desired Dynamic Selection of a Reference Model-Based PID Controller: A Case Study on a High-Pressure Heater in a 600 MW Power Plant
Nowadays, the proportional–integral–derivative (PID) controller dominates industrial process control. Because of the compromise between parameters, its tuning is still a challenge for practitioners. A reference model (RM)-based PID controller—the desired dynamic equational (DDE) PID controller—is regarded as a viable alternative since it can readily eliminate the compromise. However, how to design its desired dynamic equation remains an unsolved problem which limits the application of DDE PID controllers in large-scale industrial systems. Therefore, this paper studies the desired dynamic selection of DDE PID controllers and proposes a simple and practical selection procedure without using the accurate plant model. Simulations, experiments and filed tests demonstrate the convenience and advantages of the proposed method, thus making DDE PID an effective controller type which is specifically appealing to engineers. Moreover, the successful application of DDE PID controllers to a high-pressure (HP) heater in a coal-fired power plant shows their promising prospects in the future power industry with the increasing demand to integrate more renewables into the grid.
- Open Access
Superheated Steam Temperature Control Based on a Hybrid Active Disturbance Rejection Control
Superheated steam temperature (SST) is a significant index for a coal-fired power plant. Its control is becoming more and more challenging for the reason that the control requirements are stricter and the load command changes extensively and frequently. To deal with the aforementioned challenges, previously the cascade control strategy was usually applied to the control of SST. However, its structure and tuning procedure are complex. To solve this problem, this paper proposes a single-loop control strategy for SST based on a hybrid active disturbance rejection control (ADRC). The stability and ability to reject the secondary disturbance are analyzed theoretically in order to perfect the theory of the hybrid ADRC. Then a tuning procedure is summarized for the hybrid ADRC by analyzing the influences of all parameters on control performance. Using the proposed tuning method, a simulation is carried out illustrating that the hybrid ADRC is able to improve the dynamic performance of SST with good robustness. Eventually, the hybrid ADRC is applied to the SST system of a power plant simulator. Experimental results indicate that the single-loop control strategy based on the hybrid ADRC has better control performance and simpler structure than cascade control strategies. The successful application of the proposed hybrid ADRC shows its promising prospect of field tests in future power industry with the increasing demand on integrating more renewables into the grid.
Open AccessSuperheated Steam Temperature Control Based on a Hybrid Active Disturbance Rejection Control
Superheated steam temperature (SST) is a significant index for a coal-fired power plant. Its control is becoming more and more challenging for the reason that the control requirements are stricter and the load command changes extensively and frequently. To deal with the aforementioned challenges, previously the cascade control strategy was usually applied to the control of SST. However, its structure and tuning procedure are complex. To solve this problem, this paper proposes a single-loop control strategy for SST based on a hybrid active disturbance rejection control (ADRC). The stability and ability to reject the secondary disturbance are analyzed theoretically in order to perfect the theory of the hybrid ADRC. Then a tuning procedure is summarized for the hybrid ADRC by analyzing the influences of all parameters on control performance. Using the proposed tuning method, a simulation is carried out illustrating that the hybrid ADRC is able to improve the dynamic performance of SST with good robustness. Eventually, the hybrid ADRC is applied to the SST system of a power plant simulator. Experimental results indicate that the single-loop control strategy based on the hybrid ADRC has better control performance and simpler structure than cascade control strategies. The successful application of the proposed hybrid ADRC shows its promising prospect of field tests in future power industry with the increasing demand on integrating more renewables into the grid.
- Open Access
Highly Sensitive, Calibration-Free WM-DAS Method for Recovering Absorbance—Part I: Theoretical Analysis
The absorbance is of great importance in the tunable diode laser absorption spectroscopy (TDLAS) as it contains information of both gas properties and spectroscopic parameters. A novel, calibration-free wavelength modulation-direct absorption spectroscopy (WM-DAS) is proposed and experimentally verified in this two-part paper. This method combines the capability of absorbance measurement from DAS and the advantages of enhanced noise rejection and high sensitivity from WMS. In this Part I, we focus on the full theoretical basis and procedures of this method from the following three aspects: the high-accuracy characterizations of laser frequency and intensity, noise rejection ability by extracting the characteristic spectra through the fast Fourier transform (FFT) of the light intensity, and the simultaneous fitting strategy for both baseline and absorbance. The preliminary validation experiment of CO transition at 4300.6999 cm−1 in a static gas cell shows the high accuracy of the proposed method.
Open AccessHighly Sensitive, Calibration-Free WM-DAS Method for Recovering Absorbance—Part I: Theoretical Analysis
The absorbance is of great importance in the tunable diode laser absorption spectroscopy (TDLAS) as it contains information of both gas properties and spectroscopic parameters. A novel, calibration-free wavelength modulation-direct absorption spectroscopy (WM-DAS) is proposed and experimentally verified in this two-part paper. This method combines the capability of absorbance measurement from DAS and the advantages of enhanced noise rejection and high sensitivity from WMS. In this Part I, we focus on the full theoretical basis and procedures of this method from the following three aspects: the high-accuracy characterizations of laser frequency and intensity, noise rejection ability by extracting the characteristic spectra through the fast Fourier transform (FFT) of the light intensity, and the simultaneous fitting strategy for both baseline and absorbance. The preliminary validation experiment of CO transition at 4300.6999 cm−1 in a static gas cell shows the high accuracy of the proposed method.
- Open Access
Highly Sensitive, Calibration-Free WM-DAS Method for Recovering Absorbance—Part II: Experimental Analysis
Following the theoretical work in Part I, in this experimental study, the robustness, temporal resolution, and the narrow scan performance of the proposed wavelength modulation-direct absorption spectroscopy (WM-DAS) method are experimentally validated in a high-temperature tube furnace. The electromagnetic and other random-frequency noises can be effectively eliminated by extracting the characteristic spectra of the light intensity. The performance of WM-DAS with modulation frequencies from 0.1 to 100 kHz and scan indexes from 3.3 to 11.1 are also investigated at atmospheric pressure. The proposed method produces accurate line profile and high SNR over 500 consistently even with a weak absorption. As for real applications, the spectral line parameters of CO at 4300.6999 cm−1 including the collisional broadening, Dicke narrowing, and their dependence on temperature are measured. Furthermore, the high-speed measurement (1 ms) of the temperature and CO concentration of a McKenna flat flame are demonstrated.
Open AccessHighly Sensitive, Calibration-Free WM-DAS Method for Recovering Absorbance—Part II: Experimental Analysis
Following the theoretical work in Part I, in this experimental study, the robustness, temporal resolution, and the narrow scan performance of the proposed wavelength modulation-direct absorption spectroscopy (WM-DAS) method are experimentally validated in a high-temperature tube furnace. The electromagnetic and other random-frequency noises can be effectively eliminated by extracting the characteristic spectra of the light intensity. The performance of WM-DAS with modulation frequencies from 0.1 to 100 kHz and scan indexes from 3.3 to 11.1 are also investigated at atmospheric pressure. The proposed method produces accurate line profile and high SNR over 500 consistently even with a weak absorption. As for real applications, the spectral line parameters of CO at 4300.6999 cm−1 including the collisional broadening, Dicke narrowing, and their dependence on temperature are measured. Furthermore, the high-speed measurement (1 ms) of the temperature and CO concentration of a McKenna flat flame are demonstrated.
- Open Access
A Wide-Range and Calibration-Free Spectrometer Which Combines Wavelength Modulation and Direct Absorption Spectroscopy with Cavity Ringdown Spectroscopy
A wide-range, calibration-free tunable diode laser spectrometer is established by combining wavelength modulation and direct absorption spectroscopy (WM-DAS) with continuous wave cavity ringdown spectroscopy (CW-CRDS). This spectrometer combines the benefits of absolute concentration measurements, wide range, and high speed, using WM-DAS with enhanced noise reduction in CW-CRDS. The accurate baseline ringdown time, τ0, is calculated by the absorption peak (measured by WM-DAS) and the ringdown time containing gas absorption information (measured by CW-CRDS at the center wavelength of the spectral line). The gas concentration is obtained without measuring τ0 in real time, thus, greatly improving the measuring speed. A WM-DAS/CW-CRDS spectrometer at 1.57 μm for CO detection was assembled for experimental validation of the multiplexing scheme over a concentration ranging from 4 ppm to 1.09% (0.1 MPa, 298 K). The measured concentration of CO at 6374.406 cm−1 shows that the dynamic range of this tunable diode laser absorption spectrometer is extendable up to five orders of magnitude and the corresponding precision is improved. The measurement speed of this spectrometer can extend up to 10 ms, and the detection limit can reach 35 ppb within 25 s.
Open AccessA Wide-Range and Calibration-Free Spectrometer Which Combines Wavelength Modulation and Direct Absorption Spectroscopy with Cavity Ringdown Spectroscopy
A wide-range, calibration-free tunable diode laser spectrometer is established by combining wavelength modulation and direct absorption spectroscopy (WM-DAS) with continuous wave cavity ringdown spectroscopy (CW-CRDS). This spectrometer combines the benefits of absolute concentration measurements, wide range, and high speed, using WM-DAS with enhanced noise reduction in CW-CRDS. The accurate baseline ringdown time, τ0, is calculated by the absorption peak (measured by WM-DAS) and the ringdown time containing gas absorption information (measured by CW-CRDS at the center wavelength of the spectral line). The gas concentration is obtained without measuring τ0 in real time, thus, greatly improving the measuring speed. A WM-DAS/CW-CRDS spectrometer at 1.57 μm for CO detection was assembled for experimental validation of the multiplexing scheme over a concentration ranging from 4 ppm to 1.09% (0.1 MPa, 298 K). The measured concentration of CO at 6374.406 cm−1 shows that the dynamic range of this tunable diode laser absorption spectrometer is extendable up to five orders of magnitude and the corresponding precision is improved. The measurement speed of this spectrometer can extend up to 10 ms, and the detection limit can reach 35 ppb within 25 s.
- 10 January 2014
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 53 (3) , 1172-1178
An Iterative Two-Level Optimization Method for the Modeling of Wiener Structure Nonlinear Dynamic Soft Sensors
- 10 January 2014
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 53 (3) , 1172-1178
An Iterative Two-Level Optimization Method for the Modeling of Wiener Structure Nonlinear Dynamic Soft Sensors
- 27 September 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (20) , 23724-23735
First harmonic with wavelength modulation spectroscopy to measure integrated absorbance under low absorption
Integrated absorbance (IA) can be used to infer gas temperature and concentration directly, in this paper, we proposed a new method that uses the 1st harmonic to measure the IA under low absorption conditions (2 and H2O molecules near 6981 cm–1 are selected to determine the IA and species concentration in experiments. Calculation and experiment results show that the proposed method can accurately measure IA in actual measurements.
- 27 September 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (20) , 23724-23735
First harmonic with wavelength modulation spectroscopy to measure integrated absorbance under low absorption
Integrated absorbance (IA) can be used to infer gas temperature and concentration directly, in this paper, we proposed a new method that uses the 1st harmonic to measure the IA under low absorption conditions (2 and H2O molecules near 6981 cm–1 are selected to determine the IA and species concentration in experiments. Calculation and experiment results show that the proposed method can accurately measure IA in actual measurements.
- 2 July 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (20) , 4605-4611
Concentration measurement of NO using self-absorption spectroscopy of the γband system in a pulsed corona discharge
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 2 July 2012
- Published by Optica Publishing Group in Applied Optics
- Vol. 51 (20) , 4605-4611
Concentration measurement of NO using self-absorption spectroscopy of the γband system in a pulsed corona discharge
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.