Alessandro Borella
Alessandro Borella has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Riccardo Rossa
Belgian Nuclear Research Centre (SCK CEN), Industriezone Boeretang Zuid, Boeretang 190, 2400 Mol, Belgium
2 shared publications - Eric Boogers
SCK-CEN
1 shared publication - Sven Boden
SCK-CEN
1 shared publication - Wouter Broeckx
SCK-CEN
1 shared publication
Latest Publications
- Open Access
- 20 January 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 225, 06001
Estimation of fissile material content in irradiated In-Pile Sections using neutron coincidence counters
A set of In-Pile Sections (IPS) has been irradiated in the BR2 reactor at SCK•CEN in Belgium during the 1970’s and 1980’s. The primary goal of the IPS was to replicate the thermo-hydraulic loop of a sodium-cooled fast reactor in order to study severe accident scenarios. The top part of the IPS contained the sodium-cooled loop whereas the lower part contained the fuel element. Due to the experimental conditions, the rupture of the fuel pins contained in the IPS occurred and fuel fragments may have been deposited in the rest of the IPS loop. The part of the IPS containing the fuel pins has been cut from the rest of the IPS and underwent post-irradiation examinations at specialized EU laboratories, while the top parts remained stored at SCK•CEN. To prepare for future transport, dismantling and conditioning, a reliable estimation of the total fissile content in the stored parts of the IPS is indispensable. In this framework, two IPS were measured with a Canberra WM3400 neutron coincidence counter with customized electronics. The measurements of the IPS were challenging due their length (roughly 6 m) and intense gamma-ray radiation background. For each IPS an axial scan was carried out with a series of short measurements (600-700 s each) recording the Totals rate and Reals rate. Based on the results of the axial scans, measurements with longer measurement time were conducted for the axial positions with the larger values of Reals rates. A system of equations was then established to quantify the 240Pu content in the different sections of the IPS from the Reals rates in each measurement position and account for cross-talk between the neutron emission associated to the different sections. A set of Monte Carlo simulations was carried out to estimate the probability to record a Real count in the detector due to spontaneous fission events occurring in a given section of the IPS. The 240Pu content in each section of the IPS was calculated by combining the measured Reals rates and the detection probabilities calculated with the simulations. The total fissile content in the IPS was then determined with scaling factors based on burnup calculations for the irradiated fuel assemblies in the IPS. The results indicate that both IPS measured with the neutron coincidence counters have a fissile content lower than the limit for transport. It is expected that the envisaged segmentation of the IPS in shorter sections required to fit into 200L drums will provide an additional safety margin on this limit.
- 20 January 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 225, 06001
Open AccessEstimation of fissile material content in irradiated In-Pile Sections using neutron coincidence counters
A set of In-Pile Sections (IPS) has been irradiated in the BR2 reactor at SCK•CEN in Belgium during the 1970’s and 1980’s. The primary goal of the IPS was to replicate the thermo-hydraulic loop of a sodium-cooled fast reactor in order to study severe accident scenarios. The top part of the IPS contained the sodium-cooled loop whereas the lower part contained the fuel element. Due to the experimental conditions, the rupture of the fuel pins contained in the IPS occurred and fuel fragments may have been deposited in the rest of the IPS loop. The part of the IPS containing the fuel pins has been cut from the rest of the IPS and underwent post-irradiation examinations at specialized EU laboratories, while the top parts remained stored at SCK•CEN. To prepare for future transport, dismantling and conditioning, a reliable estimation of the total fissile content in the stored parts of the IPS is indispensable. In this framework, two IPS were measured with a Canberra WM3400 neutron coincidence counter with customized electronics. The measurements of the IPS were challenging due their length (roughly 6 m) and intense gamma-ray radiation background. For each IPS an axial scan was carried out with a series of short measurements (600-700 s each) recording the Totals rate and Reals rate. Based on the results of the axial scans, measurements with longer measurement time were conducted for the axial positions with the larger values of Reals rates. A system of equations was then established to quantify the 240Pu content in the different sections of the IPS from the Reals rates in each measurement position and account for cross-talk between the neutron emission associated to the different sections. A set of Monte Carlo simulations was carried out to estimate the probability to record a Real count in the detector due to spontaneous fission events occurring in a given section of the IPS. The 240Pu content in each section of the IPS was calculated by combining the measured Reals rates and the detection probabilities calculated with the simulations. The total fissile content in the IPS was then determined with scaling factors based on burnup calculations for the irradiated fuel assemblies in the IPS. The results indicate that both IPS measured with the neutron coincidence counters have a fissile content lower than the limit for transport. It is expected that the envisaged segmentation of the IPS in shorter sections required to fit into 200L drums will provide an additional safety margin on this limit.
- Open Access
- 20 January 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 225, 05002
Improved electronics for 3He based neutron counters
Several non-destructive assays techniques have been developed for the measurement of fissile materials in the fields of dismantling, decommissioning, nuclear security, and nuclear safeguards. Among these techniques, neutron coincidence counting is based on the detection of time-correlated neutrons from induced and spontaneous fissions. 3He Tubes have been the primary choice for neutron coincidence counting due to their high detection efficiency, rather low sensitivity to gamma-rays and proven field reliability. This paper covers the implementation of a new electronic setup to a Canberra WM3400 neutron coincidence counter.First we describe the properties of the used detectors, with focus on the characteristics of the default electronics and highlight its limitations such as the high input capacitance, short shaping time and the necessity for selected tubes. We then propose the new electronic setup to overcome these limitations. This setup includes a dedicated preamp for every tube , the possibility to adjust for gain differences between the tubes and a better optimised shaping time for 3He detectors.We carried out measurements with the two electronic systems to compare their performances in terms of gamma-ray sensitivity, efficiency and die-away time. The gamma ray sensitivity was measured with calibrated 137Cs and a 60Co sources at the Laboratory for Nuclear Calibration of the Belgian Nuclear Research Centre with dose rates between 10 μSv/h and 50 mSv/h. Measurements with a 252Cf source were used to determine the die-away time of the system and the total measurement efficiency for the considered geometry.The measurements showed that, with the default electronics, neutron count-rates are already affected by gamma radiation at a dose rate of 10÷30 μSv/h. On the other hand the neutron coincidence counter equipped with the new electronics proved to be insensitive to gamma-radiation up to a dose rate of at least 20 mSv/h. The high-voltage set with the new electronics is lower than in the case of the default electronics and is within the range recommended by the tubes manufacturer. The die-away time was not affected by the used electronics. A reduction of about 20% in the neutron detection efficiency due to the used discriminator threshold was observed.
- 20 January 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 225, 05002
Open AccessImproved electronics for 3He based neutron counters
Several non-destructive assays techniques have been developed for the measurement of fissile materials in the fields of dismantling, decommissioning, nuclear security, and nuclear safeguards. Among these techniques, neutron coincidence counting is based on the detection of time-correlated neutrons from induced and spontaneous fissions. 3He Tubes have been the primary choice for neutron coincidence counting due to their high detection efficiency, rather low sensitivity to gamma-rays and proven field reliability. This paper covers the implementation of a new electronic setup to a Canberra WM3400 neutron coincidence counter.First we describe the properties of the used detectors, with focus on the characteristics of the default electronics and highlight its limitations such as the high input capacitance, short shaping time and the necessity for selected tubes. We then propose the new electronic setup to overcome these limitations. This setup includes a dedicated preamp for every tube , the possibility to adjust for gain differences between the tubes and a better optimised shaping time for 3He detectors.We carried out measurements with the two electronic systems to compare their performances in terms of gamma-ray sensitivity, efficiency and die-away time. The gamma ray sensitivity was measured with calibrated 137Cs and a 60Co sources at the Laboratory for Nuclear Calibration of the Belgian Nuclear Research Centre with dose rates between 10 μSv/h and 50 mSv/h. Measurements with a 252Cf source were used to determine the die-away time of the system and the total measurement efficiency for the considered geometry.The measurements showed that, with the default electronics, neutron count-rates are already affected by gamma radiation at a dose rate of 10÷30 μSv/h. On the other hand the neutron coincidence counter equipped with the new electronics proved to be insensitive to gamma-radiation up to a dose rate of at least 20 mSv/h. The high-voltage set with the new electronics is lower than in the case of the default electronics and is within the range recommended by the tubes manufacturer. The die-away time was not affected by the used electronics. A reduction of about 20% in the neutron detection efficiency due to the used discriminator threshold was observed.