Felix K. Kopp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Felix K. Kopp has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Peter Benjamin Noël
Department of Radiology Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
2 shared publications - Alexander A. Fingerle
Affiliations Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, München, Germany, Kantonsspital Münsterlingen, Münsterlingen, Switzerland
1 shared publication Andreas P Sauter
Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munchen, Bayern, GERMANY
1 shared publicationBernhard Renger
Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munchen, Bayern, GERMANY
1 shared publicationDaniela Pfeiffer
Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munchen, Bayern, GERMANY
1 shared publicationErnst J Rummeny
Department of Diagnostic and Interventional Radiology, Technical University of Munich, Munchen, Bayern, GERMANY
1 shared publication
Latest Publications
- Open Access
- 1 January 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (1) , 015038
Liver lesion localisation and classification with convolutional neural networks: a comparison between conventional and spectral computed tomography
Purpose: To evaluate the benefit of the additional available information present in spectral CT datasets, as compared to conventional CT datasets, when utilizing convolutional neural networks for fully automatic localisation and classification of liver lesions in CT images. Materials and Methods: Conventional and spectral CT images (iodine maps, virtual monochromatic images (VMI)) were obtained from a spectral dual-layer CT system. Patient diagnosis were known from the clinical reports and classified into healthy, cyst and hypodense metastasis. In order to compare the value of spectral versus conventional datasets when being passed as input to machine learning algorithms, we implemented a weakly-supervised convolutional neural network (CNN) that learns liver lesion localisation without pixel-level ground truth annotations. Regions-of-interest are selected automatically based on the localisation results and are used to train a second CNN for liver lesion classification (healthy, cyst, hypodense metastasis). The accuracy of lesion localisation was evaluated using the Euclidian distances between the ground truth centres of mass and the predicted centres of mass. Lesion classification was evaluated by precision, recall, accuracy and F1-Score. Results: Lesion localisation showed the best results for spectral information with distances of 8.22 ± 10.72 mm, 8.78 ± 15.21 mm and 8.29 ± 12.97 mm for iodine maps, 40 keV and 70 keV VMIs, respectively. With conventional data distances of 10.58 ± 17.65 mm were measured. For lesion classification, the 40 keV VMIs achieved the highest overall accuracy of 0.899 compared to 0.854 for conventional data. Conclusion: An enhanced localisation and classification is reported for spectral CT data, which demonstrates that combining machine-learning technology with spectral CT information may in the future improve the clinical workflow as well as the diagnostic accuracy.
- 1 January 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (1) , 015038
Open AccessLiver lesion localisation and classification with convolutional neural networks: a comparison between conventional and spectral computed tomography
Purpose: To evaluate the benefit of the additional available information present in spectral CT datasets, as compared to conventional CT datasets, when utilizing convolutional neural networks for fully automatic localisation and classification of liver lesions in CT images. Materials and Methods: Conventional and spectral CT images (iodine maps, virtual monochromatic images (VMI)) were obtained from a spectral dual-layer CT system. Patient diagnosis were known from the clinical reports and classified into healthy, cyst and hypodense metastasis. In order to compare the value of spectral versus conventional datasets when being passed as input to machine learning algorithms, we implemented a weakly-supervised convolutional neural network (CNN) that learns liver lesion localisation without pixel-level ground truth annotations. Regions-of-interest are selected automatically based on the localisation results and are used to train a second CNN for liver lesion classification (healthy, cyst, hypodense metastasis). The accuracy of lesion localisation was evaluated using the Euclidian distances between the ground truth centres of mass and the predicted centres of mass. Lesion classification was evaluated by precision, recall, accuracy and F1-Score. Results: Lesion localisation showed the best results for spectral information with distances of 8.22 ± 10.72 mm, 8.78 ± 15.21 mm and 8.29 ± 12.97 mm for iodine maps, 40 keV and 70 keV VMIs, respectively. With conventional data distances of 10.58 ± 17.65 mm were measured. For lesion classification, the 40 keV VMIs achieved the highest overall accuracy of 0.899 compared to 0.854 for conventional data. Conclusion: An enhanced localisation and classification is reported for spectral CT data, which demonstrates that combining machine-learning technology with spectral CT information may in the future improve the clinical workflow as well as the diagnostic accuracy.
- Open Access
- 18 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9412, 94124F
A comparison of material decomposition techniques for dual-energy CT colonography
In recent years, dual-energy computed tomography (DECT) has been widely used in the clinical routine due to improved diagnostics capability from additional spectral information. One promising application for DECT is CT colonography (CTC) in combination with computer-aided diagnosis (CAD) for detection of lesions and polyps. While CAD has demonstrated in the past that it is able to detect small polyps, its performance is highly dependent on the quality of the input data. The presence of artifacts such as beam-hardening and noise in ultra-low-dose CTC may severely degrade detection performances of small polyps. In this work, we investigate and compare virtual monochromatic images, generated by image-based decomposition and projection-based decomposition, with respect to CAD performance. In the image-based method, reconstructed images are firstly decomposed into water and iodine before the virtual monochromatic images are calculated. On the contrary, in the projection-based method, the projection data are first decomposed before calculation of virtual monochromatic projection and reconstruction. Both material decomposition methods are evaluated with regards to the accuracy of iodine detection. Further, the performance of the virtual monochromatic images is qualitatively and quantitatively assessed. Preliminary results show that the projection-based method does not only have a more accurate detection of iodine, but also delivers virtual monochromatic images with reduced beam hardening artifacts in comparison with the image-based method. With regards to the CAD performance, the projection-based method yields an improved detection performance of polyps in comparison with that of the image-based method.
- 18 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9412, 94124F
Open AccessA comparison of material decomposition techniques for dual-energy CT colonography
In recent years, dual-energy computed tomography (DECT) has been widely used in the clinical routine due to improved diagnostics capability from additional spectral information. One promising application for DECT is CT colonography (CTC) in combination with computer-aided diagnosis (CAD) for detection of lesions and polyps. While CAD has demonstrated in the past that it is able to detect small polyps, its performance is highly dependent on the quality of the input data. The presence of artifacts such as beam-hardening and noise in ultra-low-dose CTC may severely degrade detection performances of small polyps. In this work, we investigate and compare virtual monochromatic images, generated by image-based decomposition and projection-based decomposition, with respect to CAD performance. In the image-based method, reconstructed images are firstly decomposed into water and iodine before the virtual monochromatic images are calculated. On the contrary, in the projection-based method, the projection data are first decomposed before calculation of virtual monochromatic projection and reconstruction. Both material decomposition methods are evaluated with regards to the accuracy of iodine detection. Further, the performance of the virtual monochromatic images is qualitatively and quantitatively assessed. Preliminary results show that the projection-based method does not only have a more accurate detection of iodine, but also delivers virtual monochromatic images with reduced beam hardening artifacts in comparison with the image-based method. With regards to the CAD performance, the projection-based method yields an improved detection performance of polyps in comparison with that of the image-based method.