ZLZhen Li

Zhen Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhen Li has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robust Path Planning via Learning From Demonstrations for Robotic Catheters in Deformable Environments

    by Zhen Li, Chiara Lambranzi, Di Wu, Alice Segato, Federico De Marco, Emmanuel Vander Poorten, Jenny Dankelman, Elena De Momi

    Objective: Navigation through tortuous and deformable vessels using catheters with limited steering capability underscores the need for reliable path planning. State-of-the-art path planners do not fully account for the deformable nature of the environment. Methods: This work proposes a robust path planner via a learning from demonstrations method, named Curriculum Generative Adversarial Imitation Learning (C-GAIL). This path planning framework takes into account the interaction between steerable catheters and vessel walls and the deformable property of vessels. Results: In-silico comparative experiments show that the proposed network achieves a 38% higher success rate in static environments and 17% higher in dynamic environments compared to a state-of-the-art approach based on GAIL. In-vitro validation experiments indicate that the path generated by the proposed C-GAIL path planner achieves a targeting error of 1.26 $\pm$ 0.55mm and a tracking error of 5.18 $\pm$ 3.48mm. These results represent improvements of 41% and 40% over the conventional centerline-following technique for targeting error and tracking error, respectively. Conclusion: The proposed C-GAIL path planner outperforms the state-of-the-art GAIL approach. The in-vitro validation experiments demonstrate that the path generated by the proposed C-GAIL path planner aligns better with the actual steering capability of the pneumatic artificial muscle-driven catheter utilized in this study. Therefore, the proposed approach can provide enhanced support to the user in navigating the catheter towards the target with greater accuracy, effectively meeting clinical accuracy requirements. Significance: The proposed path planning framework exhibits superior performance in managing uncertainty associated with vessel deformation, thereby resulting in lower tracking errors.


  • Open Access

    Deformable Model-to-Image Registration Toward Augmented Reality-Guided Endovascular Interventions

    by Zhen Li, Letizia Contini, Alessandro Maria Ippoliti, Elena Bastianelli, Federico De Marco, Jenny Dankelman, Elena De Momi

    Endovascular interventions are minimally invasive procedures that utilize the vascular system to access anatomical regions deep within the body. Image-guided assistance provides valuable real-time information about the dynamic state of the vascular environment. However, the reliance on intra-operative 2D fluoroscopy images limits depth perception, prompting the demand for intra-operative 3D imaging. Existing image registration methods face difficulties in accurately incorporating tissue deformations compared to the pre-operative 3D model, particularly in a weakly-supervised manner. Additionally, reconstructing deformations from 2D to 3D space and presenting this intra-operative model visually to clinicians poses further complexities. To address these challenges, this study introduces a novel deformable model-to-image registration framework using deep learning. Furthermore, this research proposes a visualization method through augmented reality to provide guidance for endovascular interventions. This study utilized image data collected from nine patients who underwent Transcatheter Aortic Valve Implantation (TAVI) procedures. The registration results in 2D indicate that the proposed deformable model-to-image registration framework achieves a Modified Dice Similarity Coefficient (MDSC) value of 0.89 ± 0.02 and a Penalization of Deformations in Spare Space (PDSS) value of 0.04 ± 0.01, offering an improvement of 3.5% and 98.6% over the state-of-the-art image registration approach. Additionally, the accuracy of registration in 3D was evaluated using a dataset obtained from an intervention simulator, resulting in a Mean Absolute Error (MAE) of 1.51 ± 1.02 mm within the region of interest. Overall, the study validates the feasibility and accuracy of the proposed weakly-supervised deformable model-to-image registration framework, demonstrating its potential to provide intra-operative 3D imaging as intervention assistance in dynamic vascular environments.


  • Comparative Analysis of Interactive Modalities for Intuitive Endovascular Interventions

    by Di Wu, Zhen Li, Mohammad Hasan Dad Ansari, Xuan Thao Ha, Mouloud Ourak, Jenny Dankelman, Arianna Menciassi, Elena De Momi, Emmanuel Vander Poorten

    Endovascular intervention is a minimally invasive method for treating cardiovascular diseases. Although fluoroscopy, known for real-time catheter visualization, is commonly used, it exposes patients and physicians to ionizing radiation and lacks depth perception due to its 2D nature. To address these limitations, a study was conducted using teleoperation and 3D visualization techniques. This in-vitro study involved the use of a robotic catheter system and aimed to evaluate user performance through both subjective and objective measures. The focus was on determining the most effective modes of interaction. Three interactive modes for guiding robotic catheters were compared in the study: 1) Mode GM, using a gamepad for control and a standard 2D monitor for visual feedback; 2) Mode GH, with a gamepad for control and HoloLens providing 3D visualization; and 3) Mode HH, where HoloLens serves as both control input and visualization device. Mode GH outperformed other modalities in subjective metrics, except for mental demand. It exhibited a median tracking error of 4.72 mm, a median targeting error of 1.01 mm, a median duration of 82.34 s, and a median natural logarithm of dimensionless squared jerk of 40.38 in the in-vitro study. Mode GH showed 8.5%, 4.7%, 6.5%, and 3.9% improvements over Mode GM and 1.5%, 33.6%, 34.9%, and 8.1% over Mode HH for tracking error, targeting error, duration, and dimensionless squared jerk, respectively. To sum up, the user study emphasizes the potential benefits of employing HoloLens for enhanced 3D visualization in catheterization. The user study also illustrates the advantages of using a gamepad for catheter teleoperation, including user-friendliness and passive haptic feedback, compared to HoloLens. To further gauge the potential of using a more traditional joystick as a control input device, an additional study utilizing the Haption Virtuose robot was conducted. It reveals the potential for achieving smoother trajectories, with a 38.9% reduction in total path length compared to a gamepad, potentially due to its larger range of motion and single-handed control.


  • Open Access

    Autonomous Navigation for Robot-Assisted Intraluminal and Endovascular Procedures: A Systematic Review

    by Ameya Pore, Zhen Li, Diego Dall'Alba, Albert Hernansanz, Elena De Momi, Arianna Menciassi, Alicia Casals Gelpí, Jenny Dankelman, Paolo Fiorini, Emmanuel Vander Poorten

    Increased demand for less invasive procedures has accelerated the adoption of Intraluminal Procedures (IP) and Endovascular Interventions (EI) performed through body lumens and vessels. As navigation through lumens and vessels is quite complex, interest grows to establish autonomous navigation techniques for IP and EI for reaching the target area. Current research efforts are directed toward increasing the Level of Autonomy (LoA) during the navigation phase. One key ingredient for autonomous navigation is Motion Planning (MP) techniques. This paper provides an overview of MP techniques categorizing them based on LoA. Our analysis investigates advances for the different clinical scenarios. Through a systematic literature analysis using the PRISMA method, the study summarizes relevant works and investigates the clinical aim, LoA, adopted MP techniques, and validation types. We identify the limitations of the corresponding MP methods and provide directions to improve the robustness of the algorithms in dynamic intraluminal environments. MP for IP and EI can be classified into four subgroups: node, sampling, optimization, and learning-based techniques, with a notable rise in learning-based approaches in recent years. One of the review's contributions is the identification of the limiting factors in IP and EI robotic systems hindering higher levels of autonomous navigation. In the future, navigation is bound to become more autonomous, placing the clinician in a supervisory position to improve control precision and reduce workload.


  • Open Access

    Autonomous Navigation for Robot-assisted Intraluminal and Endovascular Procedures: A Systematic Review

    by Ameya Pore, Zhen Li, Diego Dall'Alba, Albert Hernansanz, Elena De Momi, Arianna Menciassi, Alicia Casals, Jenny Denkelman, Paolo Fiorini, Emmanuel Vander Poorten

    Increased demand for less invasive procedures has accelerated the adoption of Intraluminal Procedures (IP) and Endovascular Interventions (EI) performed through body lumens and vessels. As navigation through lumens and vessels is quite complex, interest grows to establish autonomous navigation techniques for IP and EI for reaching the target area. Current research efforts are directed toward increasing the Level of Autonomy (LoA) during the navigation phase. One key ingredient for autonomous navigation is Motion Planning (MP) techniques. This paper provides an overview of MP techniques categorizing them based on LoA. Our analysis investigates advances for the different clinical scenarios. Through a systematic literature analysis using the PRISMA method, the study summarizes relevant works and investigates the clinical aim, LoA, adopted MP techniques, and validation types. We identify the limitations of the corresponding MP methods and provide directions to improve the robustness of the algorithms in dynamic intraluminal environments. MP for IP and EI can be classified into four subgroups: node, sampling, optimization, and learning-based techniques, with a notable rise in learning-based approaches in recent years. One of the review's contributions is the identification of the limiting factors in IP and EI robotic systems hindering higher levels of autonomous navigation. In the future, navigation is bound to become more autonomous, placing the clinician in a supervisory position to improve control precision and reduce workload.

  • Position-based dynamics simulator of vessel deformations for path planning in robotic endovascular catheterization

    by Zhen Li, Enrico Manzionna, Giovanni Monizzi, Angelo Mastrangelo, Maria Elisabetta Mancini, Daniele Andreini, Jenny Dankelman, Elena De Momi

    A major challenge during autonomous navigation in endovascular interventions is the complexity of operating in a deformable but constrained workspace with an instrument. Simulation of deformations for it can provide a cost-effective training platform for path planning. Aim of this study is to develop a realistic, auto-adaptive, and visually plausible simulator to predict vessels' global deformation induced by the robotic catheter's contact and cyclic heartbeat motion. Based on a Position-based Dynamics (PBD) approach for vessel modeling, Particle Swarm Optimization (PSO) algorithm is employed for an auto-adaptive calibration of PBD deformation parameters and of the vessels movement due to a heartbeat. In-vitro experiments were conducted and compared with in-silico results. The end-user evaluation results were reported through quantitative performance metrics and a 5-Point Likert Scale questionnaire. Compared with literature, this simulator has an error of 0.23±0.13% for deformation and 0.30±0.85mm for the aortic root displacement. In-vitro experiments show an error of 1.35±1.38mm for deformation prediction. The end-user evaluation results show that novices are more accustomed to using joystick controllers, and cardiologists are more satisfied with the visual authenticity. The real-time and accurate performance of the simulator make this framework suitable for creating a dynamic environment for autonomous navigation of robotic catheters.


  • Open Access

    Path planning for endovascular catheterization under curvature constraints via two-phase searching approach

    by Zhen Li, Jenny Dankelman, Elena De Momi

    Purpose: Planning a safe path for flexible catheters is one of the major challenges of endovascular catheterization. State-of-the-art methods rarely consider the catheter curvature constraint and reduced computational time of path planning which guarantees the possibility to re-plan the path during the actual operation. Methods: In this manuscript, we propose a fast two-phase path planning approach under the robot curvature constraint. Firstly, the vascular structure is extracted and represented by vascular centerlines and corresponding vascular radii. Then, the path is searched along the vascular centerline using breadth first search (BFS) strategy and locally optimized via the genetic algorithm (GA) to satisfy the robot curvature constraint. This approach (BFS-GA) is able to respect the robot curvature constraint while keeping it close to the centerlines as much as possible. We can also reduce the optimization search space and perform parallel optimization to shorten the computational time. Results: We demonstrate the method’s high efficiency in two-dimensional and three-dimensional space scenarios. The results showed the planner’s ability to satisfy the robot curvature constraint while keeping low computational time cost compared with sampling-based methods. Path replanning in femoral arteries can reach an updating frequency at $$6.4\pm 2.3$$ 6.4 ± 2.3 Hz. Conclusion: The presented work is suited for surgical procedures demanding satisfying curvature constraints while optimizing specified criteria. It is also applicable for curvature constrained robots in narrow passages.


  • Open Access

    Design and Control of a Variable Aerial Cable Towed System

    by Zhen Li, Julian Erskine, Stéphane Caro, Abdelhamid Chriette

    Aerial Cable Towed Systems (ACTS) are composed of several Unmanned Aerial Vehicles (UAVs) connected to a payload by cables. Compared to towing objects from individual aerial vehicles, an ACTS has significant advantages such as heavier payload capacity, modularity, and full control of the payload pose. They are however generally large with limited ability to meet geometric constraints while avoiding collisions between UAVs. This paper presents the modelling, performance analysis, design, and a proposed controller for a novel ACTS with variable cable lengths, named Variable Aerial Cable Towed System (VACTS).Winches are embedded on the UAVs for actuating the cable lengths similar to a Cable-Driven Parallel Robot to increase the versatility of the ACTS. The general geometric, kinematic and dynamic models of the VACTS are derived, followed by the development of a centralized feedback linearization controller. The design is based on a wrench analysis of the VACTS, without constraining the cables to pass through the UAV center of mass, as in current works. Additionally, the performance of the VACTS and ACTS are compared showing that the added versatility comes at the cost of payload and configuration flexibility. A prototype confirms the feasibility of the system.

  • Design and Control of a Variable Aerial Cable Towed System

    by Zhen Li, Julian Erskine, Stephane Caro, Abdelhamid Chriette

    Aerial Cable Towed Systems (ACTS) are composed of several Unmanned Aerial Vehicles (UAVs) connected to a payload by cables. Compared to towing objects from individual aerial vehicles, an ACTS has significant advantages such as heavier payload capacity, modularity, and full control of the payload pose. They are however generally large with limited ability to meet geometric constraints while avoiding collisions between UAVs. This paper presents the modelling, performance analysis, design, and a proposed controller for a novel ACTS with variable cable lengths, named Variable Aerial Cable Towed System (VACTS). Winches are embedded on the UAVs for actuating the cable lengths similar to a Cable-Driven Parallel Robot to increase the versatility of the ACTS. The general geometric, kinematic and dynamic models of the VACTS are derived, followed by the development of a centralized feedback linearization controller. The design is based on a wrench analysis of the VACTS, without constraining the cables to pass through the UAV center of mass, as in current works. Additionally, the performance of the VACTS and ACTS are compared showing that the added versatility comes at the cost of payload and configuration flexibility. A prototype confirms the feasibility of the system.