Martin Weaver
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Weaver has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Best
Department of Orthopedic Trauma, Henry Ford St. John Hospital, Detroit, Michigan
4 shared publications - Safia Z. Barakzai
Equine Surgical Referrals Brighton UK
3 shared publications - Usher Khan
Central Michigan University College of Medicine, Mount Pleasant, Michigan
3 shared publications - Alan Afsari
Department of Orthopedic Trauma, Henry Ford St. John Hospital, Detroit, Michigan
2 shared publications Simarjeet Puri
Department of Orthopaedic Surgery, Henry Ford Providence Hospital, Southfield, Michigan
2 shared publications- Adrian Olson
Department of Orthopaedic Surgery, Ascension Macomb-Oakland, 27351 Dequindre Rd, Madison Heights, MI, 48071, USA
1 shared publication
Latest Publications
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 16 (1)
Fixation of a Peri-Implant Distal Femur Fracture Adjacent to Cephalomedullary Nail With Retrograde Intramedullary Nail in a Capacious Canal
Case: A 75-year-old woman presented after a low-energy fall with a minimally displaced, extra-articular peri-implant distal femur fracture at the tip of a previously placed cephalomedullary nail. Her proximal femur was in native varus, and she was profoundly osteoporotic, resulting in a capacious distal femoral metaphyseal canal and a laterally positioned distal nail tip. Because her anatomy appeared to permit safe implant overlap without excessive canal “overstuffing,” a retrograde femoral nail was inserted adjacent to the existing cephalomedullary nail using a percutaneous technique. She was mobilized weight bearing as tolerated. At approximately 1 year postoperatively, documentation noted painless full knee range of motion, intact distal vascular status, and continued safe wheelchair transfers. Conclusion: In carefully selected patients with favorable anatomy, peri-implant distal femur fractures at the tip of a cephalomedullary nail may be stabilized with an overlapping retrograde femoral nail as one option alongside minimally invasive plating and other strategies.
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 16 (1)
Fixation of a Peri-Implant Distal Femur Fracture Adjacent to Cephalomedullary Nail With Retrograde Intramedullary Nail in a Capacious Canal
Case: A 75-year-old woman presented after a low-energy fall with a minimally displaced, extra-articular peri-implant distal femur fracture at the tip of a previously placed cephalomedullary nail. Her proximal femur was in native varus, and she was profoundly osteoporotic, resulting in a capacious distal femoral metaphyseal canal and a laterally positioned distal nail tip. Because her anatomy appeared to permit safe implant overlap without excessive canal “overstuffing,” a retrograde femoral nail was inserted adjacent to the existing cephalomedullary nail using a percutaneous technique. She was mobilized weight bearing as tolerated. At approximately 1 year postoperatively, documentation noted painless full knee range of motion, intact distal vascular status, and continued safe wheelchair transfers. Conclusion: In carefully selected patients with favorable anatomy, peri-implant distal femur fractures at the tip of a cephalomedullary nail may be stabilized with an overlapping retrograde femoral nail as one option alongside minimally invasive plating and other strategies.
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 16 (1)
Traumatic Rupture of Tibialis Posterior and Flexor Digitorum Longus in an Isolated Medial Malleolus Fracture
Case: A 78-year-old man with type 2 diabetes and spinal stenosis complicated by chronic neuropathy suffered an open medial malleolus fracture with proximal tendon rupture after fall from height. Fracture fixation was achieved with cannulated screws. Meticulous repair of the proximal tibialis posterior and flexor digitorum longus tendon avulsions required tunneling into the deep posterior compartment. Postoperatively, the patient was non–weight bearing, responsive to therapy, and discharged home. Conclusion: This unique case illustrates the importance of maintaining a high index of suspicion for tendinous injury. A careful physical examination, understanding of injury mechanisms, and a high index of suspicion for these associated injuries should be maintained to maximize patient outcomes.
- 1 January 2026
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 16 (1)
Traumatic Rupture of Tibialis Posterior and Flexor Digitorum Longus in an Isolated Medial Malleolus Fracture
Case: A 78-year-old man with type 2 diabetes and spinal stenosis complicated by chronic neuropathy suffered an open medial malleolus fracture with proximal tendon rupture after fall from height. Fracture fixation was achieved with cannulated screws. Meticulous repair of the proximal tibialis posterior and flexor digitorum longus tendon avulsions required tunneling into the deep posterior compartment. Postoperatively, the patient was non–weight bearing, responsive to therapy, and discharged home. Conclusion: This unique case illustrates the importance of maintaining a high index of suspicion for tendinous injury. A careful physical examination, understanding of injury mechanisms, and a high index of suspicion for these associated injuries should be maintained to maximize patient outcomes.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (3)
The Motown Corkscrew
Case: A 17-year-old boy presented after a gunshot wound; computed tomography showed a comminuted posterior-wall acetabular fracture and a bullet 90% embedded. Through a Ganz surgical dislocation, a standard 2.5 mm drill bit was advanced 8 to 10 mm into the projectile, its flutes functioning as a self-tapping screw to rock and extract the bullet en bloc, followed by trochanteric osteotomy fixation. He regained painless full activity by 2 months; 33-month imaging confirmed durable union with no osteolysis. Conclusion: The “Motown Corkscrew” technique provides a cost-neutral, controlled method to remove bone-embedded intra-articular bullets while preserving articular structures.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (3)
The Motown Corkscrew
Case: A 17-year-old boy presented after a gunshot wound; computed tomography showed a comminuted posterior-wall acetabular fracture and a bullet 90% embedded. Through a Ganz surgical dislocation, a standard 2.5 mm drill bit was advanced 8 to 10 mm into the projectile, its flutes functioning as a self-tapping screw to rock and extract the bullet en bloc, followed by trochanteric osteotomy fixation. He regained painless full activity by 2 months; 33-month imaging confirmed durable union with no osteolysis. Conclusion: The “Motown Corkscrew” technique provides a cost-neutral, controlled method to remove bone-embedded intra-articular bullets while preserving articular structures.
- 16 June 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (9) , S292-S298
Efficacy of Commercially Available Irrigation Solutions on Removal of Staphylococcus Aureus and Biofilm From Porous Titanium Implants: An In Vitro Study
- 16 June 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (9) , S292-S298
Efficacy of Commercially Available Irrigation Solutions on Removal of Staphylococcus Aureus and Biofilm From Porous Titanium Implants: An In Vitro Study
- Open Access
- 16 December 2023
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 4 (2) , 261-265
Extra-capsular migration of a broken glenoid reaming guidewire
- 16 December 2023
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 4 (2) , 261-265
Open AccessExtra-capsular migration of a broken glenoid reaming guidewire
- Open Access
- 11 July 2021
- Published by Springer Nature in Cureus
- Vol. 13 (7) , e16318
Ruptured Bullae: A Case of Transthyretin Cardiac Amyloidosis
Amyloidosis is a rare disease with an incidence of only 16.6 per 100,000 patients per year. A high grade of clinical suspicion is required to suspect an atypical cause of left ventricular hypertrophy or new-onset heart failure. A transthoracic echocardiogram (TTE) is the initial evaluation that may yield clues pointing towards an etiology of cardiac amyloidosis. Due to the subjective nature of TTE interpretations, suspicion for cardiac amyloidosis may be missed. Once suspicion arises, additional tests, such as serum and urine electrophoresis and technetium-99m pyrophosphate myocardial perfusion imaging, can further aid in establishing a diagnosis. The pathophysiology in transthyretin amyloidosis (ATTR) involves the misfolding of the transthyretin/prealbumin protein, which leads to an inherent propensity to aggregate. These proteins can accumulate in the extracellular space between cardiac myocytes, which may thicken sections of the heart, leading to ventricular restriction. Here, we explore the case of an 83-year-old man with chronic, treatment-resistant heart failure with preserved ejection fraction, New York Heart Association class III, who presented with multiple ruptured bullae in the bilateral lower extremity, leading to a new diagnosis of ATTR cardiac amyloidosis.
- 11 July 2021
- Published by Springer Nature in Cureus
- Vol. 13 (7) , e16318
Open AccessRuptured Bullae: A Case of Transthyretin Cardiac Amyloidosis
Amyloidosis is a rare disease with an incidence of only 16.6 per 100,000 patients per year. A high grade of clinical suspicion is required to suspect an atypical cause of left ventricular hypertrophy or new-onset heart failure. A transthoracic echocardiogram (TTE) is the initial evaluation that may yield clues pointing towards an etiology of cardiac amyloidosis. Due to the subjective nature of TTE interpretations, suspicion for cardiac amyloidosis may be missed. Once suspicion arises, additional tests, such as serum and urine electrophoresis and technetium-99m pyrophosphate myocardial perfusion imaging, can further aid in establishing a diagnosis. The pathophysiology in transthyretin amyloidosis (ATTR) involves the misfolding of the transthyretin/prealbumin protein, which leads to an inherent propensity to aggregate. These proteins can accumulate in the extracellular space between cardiac myocytes, which may thicken sections of the heart, leading to ventricular restriction. Here, we explore the case of an 83-year-old man with chronic, treatment-resistant heart failure with preserved ejection fraction, New York Heart Association class III, who presented with multiple ruptured bullae in the bilateral lower extremity, leading to a new diagnosis of ATTR cardiac amyloidosis.
- Open Access
- 22 January 2020
- Published by Hindawi Limited in International Journal of Pediatrics
- Vol. 2020, 1-5
Prevalence of Bacterial Contamination of Casting Material in a Pediatric Population
Surgical site infection is a relatively common and devastating complication following pediatric orthopedic surgery. Many infections have been determined to be the result of settled airborne particles on surgical equipment and the sterile field. Fiberglass casts are commonly used orthopedic fixation devices before and after surgery; however, fiberglass casting material is expelled during the removal process and represents an uninvestigated area for the possibility of cast saw dust as a source of airborne bacterial contamination in an operating room setting. This study evaluates the prevalence and distribution of microbiota on 90 pediatric casts by collecting and culturing fiberglass cast material from 90 pediatric casts. Bacterial identification was performed using a Bruker Biotyper Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry device. 81 out of 90 casts (90%) showed evidence of microbial contamination. Isolated species were very diverse and ranged from normal skin flora to opportunistic pathogens. The 5 most commonly isolated organisms were Acinetobacter pittii, Enterobacter cloacae, Micrococcus luteus, Staphylococcus epidermidis, and Staphylococcus hominis. Further investigation is required to determine if casting material is truly a cause of surgical site infection.
- 22 January 2020
- Published by Hindawi Limited in International Journal of Pediatrics
- Vol. 2020, 1-5
Open AccessPrevalence of Bacterial Contamination of Casting Material in a Pediatric Population
Surgical site infection is a relatively common and devastating complication following pediatric orthopedic surgery. Many infections have been determined to be the result of settled airborne particles on surgical equipment and the sterile field. Fiberglass casts are commonly used orthopedic fixation devices before and after surgery; however, fiberglass casting material is expelled during the removal process and represents an uninvestigated area for the possibility of cast saw dust as a source of airborne bacterial contamination in an operating room setting. This study evaluates the prevalence and distribution of microbiota on 90 pediatric casts by collecting and culturing fiberglass cast material from 90 pediatric casts. Bacterial identification was performed using a Bruker Biotyper Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry device. 81 out of 90 casts (90%) showed evidence of microbial contamination. Isolated species were very diverse and ranged from normal skin flora to opportunistic pathogens. The 5 most commonly isolated organisms were Acinetobacter pittii, Enterobacter cloacae, Micrococcus luteus, Staphylococcus epidermidis, and Staphylococcus hominis. Further investigation is required to determine if casting material is truly a cause of surgical site infection.
- 4 December 2009
- Published by Elsevier
- p. 95-101
Radiography of the Elbow