Aldo Di Zenobio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aldo Di Zenobio has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Luigi Muzzi
NUC department, ENEA, Frascati, Italy
24 shared publications - Simonetta Turtu
Superconductivity Laboratory, ENEA, Frascati, Italy
20 shared publications - Antonio della Corte
ENEA, Frascati, Italy
19 shared publications - Gianluca De Marzi
NUC department, ENEA, Frascati, Italy
12 shared publications - Lorenzo Giannini
EUROfusion, Garching, Germany
10 shared publications - Gherardo Romanelli
Superconductivity Lab of ENEA, Frascati, Italy
8 shared publications
Latest Publications
- 17 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
Development Status of the HTS SECAS Conductor for a Full-Size Test Sample
The ENEA Superconductivity Laboratory, in collaboration with the industrial partner TRATOS Cavi, is continuing the development activity of the high-current / high-field SECAS Cable-in-Conduit conductor, based on stacked REBCO tapes and a segmented, sector-shaped Cu former. The test outcome of various prototypes, carried out at 77 K and self-field in the previous years, have clarified important aspects of the manufacturing process and cable performance, and identified the key aspects of the processing steps. The industrial manufacturing process is consequently being developed, and partly applied for the manufacture of full-size samples, to be tested in the SULTAN facility. The conductor is designed to operate at 4.5 K, with a current of 60 kA and at a field of 18 T (as required by the EUROFusion DEMO development plan). Different layouts have been probed, either based on 4 mm-wide, or on 12 mm-wide tapes, but maintaining the same total superconductor cross-section, to verify the impact on AC losses and on tape mechanics. Two of these layouts are being assembled into a single SULTAN sample, made of two legs connected by a bottom joint. The sample will also be equipped with fiber optic sensors, to demonstrate quench detection capabilities. The main results of the development activities, based so far on tests carried out at 77 K and self-field of short cable lengths, are presented and commented in this work.
- 17 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
Development Status of the HTS SECAS Conductor for a Full-Size Test Sample
The ENEA Superconductivity Laboratory, in collaboration with the industrial partner TRATOS Cavi, is continuing the development activity of the high-current / high-field SECAS Cable-in-Conduit conductor, based on stacked REBCO tapes and a segmented, sector-shaped Cu former. The test outcome of various prototypes, carried out at 77 K and self-field in the previous years, have clarified important aspects of the manufacturing process and cable performance, and identified the key aspects of the processing steps. The industrial manufacturing process is consequently being developed, and partly applied for the manufacture of full-size samples, to be tested in the SULTAN facility. The conductor is designed to operate at 4.5 K, with a current of 60 kA and at a field of 18 T (as required by the EUROFusion DEMO development plan). Different layouts have been probed, either based on 4 mm-wide, or on 12 mm-wide tapes, but maintaining the same total superconductor cross-section, to verify the impact on AC losses and on tape mechanics. Two of these layouts are being assembled into a single SULTAN sample, made of two legs connected by a bottom joint. The sample will also be equipped with fiber optic sensors, to demonstrate quench detection capabilities. The main results of the development activities, based so far on tests carried out at 77 K and self-field of short cable lengths, are presented and commented in this work.
- Open Access
- 18 March 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (4) , 045605
Test results of the DTT poloidal field conductor samples in SULTAN: DC and AC characterization
The poloidal field (PF) magnet system of the Divertor Tokamak Test (DTT) facility consists of 6 superconducting coils with full top-down symmetry, realized in Nb3Sn (PF1 and PF6) and NbTi (PF2, PF3, PF4 and PF5). To validate the NbTi PF coil design, short samples of the cable-in-conduit-conductor cables (CICCs) have been qualified by dedicated cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL). In this work, we present the results of the two test campaigns conducted in August and September 2022, for the PF2/5 and PF3/4, respectively. The extensive characterization of the NbTi PF samples included a set of AC loss measurements using bipolar sinusoidal pulsing, as well as a set of DC tests spanning the range of the coils operability to assess the critical current, I c, and the current sharing temperature, T cs . The performances have been checked after electro-magnetic (EM) cyclic loading (up to 1000 cycles) at different B/I loads. The minimum quench energy (MQE) has also been measured at different temperatures. All tests confirmed the effectiveness of the PF CICCs design, showing good performance above the minimum acceptance values even at currents 110% higher than the nominal value.
- 18 March 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (4) , 045605
Open AccessTest results of the DTT poloidal field conductor samples in SULTAN: DC and AC characterization
The poloidal field (PF) magnet system of the Divertor Tokamak Test (DTT) facility consists of 6 superconducting coils with full top-down symmetry, realized in Nb3Sn (PF1 and PF6) and NbTi (PF2, PF3, PF4 and PF5). To validate the NbTi PF coil design, short samples of the cable-in-conduit-conductor cables (CICCs) have been qualified by dedicated cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL). In this work, we present the results of the two test campaigns conducted in August and September 2022, for the PF2/5 and PF3/4, respectively. The extensive characterization of the NbTi PF samples included a set of AC loss measurements using bipolar sinusoidal pulsing, as well as a set of DC tests spanning the range of the coils operability to assess the critical current, I c, and the current sharing temperature, T cs . The performances have been checked after electro-magnetic (EM) cyclic loading (up to 1000 cycles) at different B/I loads. The minimum quench energy (MQE) has also been measured at different temperatures. All tests confirmed the effectiveness of the PF CICCs design, showing good performance above the minimum acceptance values even at currents 110% higher than the nominal value.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Characterization of the Full-Size Superconducting ASG Joint Designed for the DTT Toroidal Field Coils
The Divertor Tokamak Test (DTT) facility is a challenging high-field and compact tokamak, currently under construction at the Frascati ENEA Research Center. Its purpose is to significantly contribute to the exploration, design and assessment of systems intended for the management of heat exhaust. Its superconducting magnetic system consists of 18 Toroidal Field (TF) coils, 6 Poloidal Field (PF) coils and a Central Solenoid (CS). This work is focused on the superconducting praying-hands joint, manufactured by ASG-Superconductors for the DTT TF coils terminations and for the connection among the adjacent double-pancakes constituting the TF winding pack. The joint has been tested and fully characterized by dedicated 2-weeks cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL) in November 2023. The tests included 3000 EM cycles at the maximum foreseen operative load of 8.1 T–21 kA and two Warm-Up-Cool-Down (WUCD) cycles, while reference DC measurements were done in normal and reversed polarity up to 42.5 kA and to 4 T, before, during and after cyclic loading and WUCDs. Assessment of AC losses, performed through bipolar sinusoidal pulsing at frequencies up to 2 Hz, and pressure drop measurements as a function of He mass flow rate, were conducted on the virgin sample and after full cyclic loading. The Minimum Quench Energy (MQE) has also been measured at different temperatures under nominal current conditions. All the conducted tests confirmed the efficacy and goodness of the joint design, with its resistance at self-field consistently remaining below the nominal allowable value of 2 nΩ.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Characterization of the Full-Size Superconducting ASG Joint Designed for the DTT Toroidal Field Coils
The Divertor Tokamak Test (DTT) facility is a challenging high-field and compact tokamak, currently under construction at the Frascati ENEA Research Center. Its purpose is to significantly contribute to the exploration, design and assessment of systems intended for the management of heat exhaust. Its superconducting magnetic system consists of 18 Toroidal Field (TF) coils, 6 Poloidal Field (PF) coils and a Central Solenoid (CS). This work is focused on the superconducting praying-hands joint, manufactured by ASG-Superconductors for the DTT TF coils terminations and for the connection among the adjacent double-pancakes constituting the TF winding pack. The joint has been tested and fully characterized by dedicated 2-weeks cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL) in November 2023. The tests included 3000 EM cycles at the maximum foreseen operative load of 8.1 T–21 kA and two Warm-Up-Cool-Down (WUCD) cycles, while reference DC measurements were done in normal and reversed polarity up to 42.5 kA and to 4 T, before, during and after cyclic loading and WUCDs. Assessment of AC losses, performed through bipolar sinusoidal pulsing at frequencies up to 2 Hz, and pressure drop measurements as a function of He mass flow rate, were conducted on the virgin sample and after full cyclic loading. The Minimum Quench Energy (MQE) has also been measured at different temperatures under nominal current conditions. All the conducted tests confirmed the efficacy and goodness of the joint design, with its resistance at self-field consistently remaining below the nominal allowable value of 2 nΩ.
- 20 March 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 193
Estimation of the power dissipation on the casing of DTT toroidal field coil during a fast plasma disruption
- 20 March 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 193
Estimation of the power dissipation on the casing of DTT toroidal field coil during a fast plasma disruption
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Preliminary Electromagnetic and Structural Analyses of the Conductors and Clamps of the DTT Current Feeders
The Divertor Tokamak Test facility (DTT) is being constructed in the Research Centre of ENEA Frascati. This nuclear fusion device is devoted to tackle the power exhaust issue in the view of future fusion power plant. The conceptual design and the performances of the DTT superconducting magnet feeders, with NbTi cables, are evaluated based on coupled electromagnetic and structural analyses. We here present a preliminary structural assessment of the feeder clamps. We have considered the self-field condition and the higher force per unit length on feeder paths as evaluated from a 3D EM simulation. The stress state is evaluated by means of a 2D model with plane stress with thickness formulation. Further, the bolt dimension and class, together with the distance between two clamps, is provided in both self-field and maximum force per unit length conditions.
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-4
Preliminary Electromagnetic and Structural Analyses of the Conductors and Clamps of the DTT Current Feeders
The Divertor Tokamak Test facility (DTT) is being constructed in the Research Centre of ENEA Frascati. This nuclear fusion device is devoted to tackle the power exhaust issue in the view of future fusion power plant. The conceptual design and the performances of the DTT superconducting magnet feeders, with NbTi cables, are evaluated based on coupled electromagnetic and structural analyses. We here present a preliminary structural assessment of the feeder clamps. We have considered the self-field condition and the higher force per unit length on feeder paths as evaluated from a 3D EM simulation. The stress state is evaluated by means of a 2D model with plane stress with thickness formulation. Further, the bolt dimension and class, together with the distance between two clamps, is provided in both self-field and maximum force per unit length conditions.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
Design and Feasibility Assessment of an HTS Sector Shaped High-Current Conductor for Fusion Coils
Technologies based on High Temperature Superconductors (HTS) are evolving rapidly toward maturity. Within the magnetic confinement fusion environment, several projects are demonstrating the possibility to integrate HTS in the coil systems. With respect to Low Temperature Superconducting (LTS) technologies, HTS could allow extending the operating space of fusion coils, either at higher temperatures, or at higher magnetic field levels, and in any case with larger operating margins. Different perspectives and development strategies are proposed, depending on whether HTS is considered a technology to completely substitute LTS, or to integrate and extend its performance range. A fundamental common requirement is the assessment of the layout, the feasibility, and performance demonstration of high-current conductors. Starting from the results achieved with the Al-slotted core cable-in-conduit conductor, and with a view on existing concepts for standard copper and aluminum cables, we have designed a new HTS sector-cable concept, to allow a flexible conductor design and a robust industrial processing. Several trials have been carried out, to verify the manufacturing approach, using either Al- or Cu-based stabilizers. Prototype sub-cables have been characterized at 77 K and self-field, as a necessary step toward the final target of a CICC operating stably with 60 kA at 4.2 K and 18 T, that is presently of interest for the EU-DEMO Central Solenoid Coil.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-6
Design and Feasibility Assessment of an HTS Sector Shaped High-Current Conductor for Fusion Coils
Technologies based on High Temperature Superconductors (HTS) are evolving rapidly toward maturity. Within the magnetic confinement fusion environment, several projects are demonstrating the possibility to integrate HTS in the coil systems. With respect to Low Temperature Superconducting (LTS) technologies, HTS could allow extending the operating space of fusion coils, either at higher temperatures, or at higher magnetic field levels, and in any case with larger operating margins. Different perspectives and development strategies are proposed, depending on whether HTS is considered a technology to completely substitute LTS, or to integrate and extend its performance range. A fundamental common requirement is the assessment of the layout, the feasibility, and performance demonstration of high-current conductors. Starting from the results achieved with the Al-slotted core cable-in-conduit conductor, and with a view on existing concepts for standard copper and aluminum cables, we have designed a new HTS sector-cable concept, to allow a flexible conductor design and a robust industrial processing. Several trials have been carried out, to verify the manufacturing approach, using either Al- or Cu-based stabilizers. Prototype sub-cables have been characterized at 77 K and self-field, as a necessary step toward the final target of a CICC operating stably with 60 kA at 4.2 K and 18 T, that is presently of interest for the EU-DEMO Central Solenoid Coil.
- 5 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Electromechanical Characterization of Advanced Internal-Tin Nb3Sn Strands for the DTT Magnet System
This paper presents a practical parameterization of the critical surface of the 0.82-mm diameter Nb 3 Sn strands used for the Toroidal Field coils of the Italian Divertor Tokamak Test Facility. The critical current has been measured by means of a Walters Spring device as a function of uniaxial applied strain (±0.5% intrinsic strain) at different field (up to 14 T) and in the temperature range comprised between 4.5 K and 10 K. The experimental results have been analyzed in the framework of the ITER-2008 parameterization and the Extrapolative Scaling Expression, by using a multi-step approach for the data fitting. The accuracy of the scaling laws provides an accurate parameterization of the critical surface in terms of field, temperature and strain, to be used for the characterization and production follow-up of the DTT qualification samples and coils.
- 5 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Electromechanical Characterization of Advanced Internal-Tin Nb3Sn Strands for the DTT Magnet System
This paper presents a practical parameterization of the critical surface of the 0.82-mm diameter Nb 3 Sn strands used for the Toroidal Field coils of the Italian Divertor Tokamak Test Facility. The critical current has been measured by means of a Walters Spring device as a function of uniaxial applied strain (±0.5% intrinsic strain) at different field (up to 14 T) and in the temperature range comprised between 4.5 K and 10 K. The experimental results have been analyzed in the framework of the ITER-2008 parameterization and the Extrapolative Scaling Expression, by using a multi-step approach for the data fitting. The accuracy of the scaling laws provides an accurate parameterization of the critical surface in terms of field, temperature and strain, to be used for the characterization and production follow-up of the DTT qualification samples and coils.
- 3 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (7) , 1-10
Transient Electrical Behavior of the TF Superconducting Coils of Divertor Tokamak Test Facility During a Fast Discharge
The article is focused on the electromagnetic analysis of the toroidal field superconducting coils (TFCs) of the Divertor Tokamak Test facility (DTT) when electrical transients occur in the TFCs system: for example, during the operations of the fast discharge units (FDUs) and considering also, the simultaneous occurrence of a fault condition. During the FDU intervention, a transient voltage excitation lasting few milliseconds occurs at the TFC terminals and it electrically stresses the insulations of TFCs itself. To investigate the voltage distribution across, inside and between different double pancakes (DPs) of each TFC, a lumped parameters circuital model has been developed and implemented in Ansys Simplorer simulation environment. This model includes both the detailed submodel of each TFC and FDU. The transient analyses have been carried out for two different scenarios: a reference one and a failure scenario, considering three different fault resistance values and also two different values of the resistance connecting the TF case to ground. In order to verify the correct sizing of the coil insulation and the TF case-to-ground resistance value inserted in the circuit of each TFC, the voltages of each TFC (terminal-to-terminal, terminal-to-ground, across of adjacent DPs, and between other circuit points) were computed in the time domain (in the range of milliseconds) for both scenarios. An overview of calculations and simulation results is presented and discussed, pointing out a high sensitivity of fault conditions and of overvoltage values and addressing mitigation strategies.
- 3 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (7) , 1-10
Transient Electrical Behavior of the TF Superconducting Coils of Divertor Tokamak Test Facility During a Fast Discharge
The article is focused on the electromagnetic analysis of the toroidal field superconducting coils (TFCs) of the Divertor Tokamak Test facility (DTT) when electrical transients occur in the TFCs system: for example, during the operations of the fast discharge units (FDUs) and considering also, the simultaneous occurrence of a fault condition. During the FDU intervention, a transient voltage excitation lasting few milliseconds occurs at the TFC terminals and it electrically stresses the insulations of TFCs itself. To investigate the voltage distribution across, inside and between different double pancakes (DPs) of each TFC, a lumped parameters circuital model has been developed and implemented in Ansys Simplorer simulation environment. This model includes both the detailed submodel of each TFC and FDU. The transient analyses have been carried out for two different scenarios: a reference one and a failure scenario, considering three different fault resistance values and also two different values of the resistance connecting the TF case to ground. In order to verify the correct sizing of the coil insulation and the TF case-to-ground resistance value inserted in the circuit of each TFC, the voltages of each TFC (terminal-to-terminal, terminal-to-ground, across of adjacent DPs, and between other circuit points) were computed in the time domain (in the range of milliseconds) for both scenarios. An overview of calculations and simulation results is presented and discussed, pointing out a high sensitivity of fault conditions and of overvoltage values and addressing mitigation strategies.
- Open Access
- 12 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-7
Analysis of the Thermal-Hydraulic Effects of a Plasma Disruption on the DTT TF Magnets
The Divertor Tokamak Test (DTT) facility, a fully superconducting nuclear fusion reactor being built in Italy, will contribute to address the power exhaust problem in EU DEMO perspective. A lot of flexibility of operation will be demanded to the machine, which should be capable to tackle also severe transients such as plasma disruptions. In this work, the 4C thermal-hydraulic code is used to compute the temperature margin during a plasma disruption, using as input the heat generated into the Toroidal Field coil casing and transferred to the winding pack, and the possibility that this leads to a quench of the magnet is studied. The results of the analysis will give important feedbacks for the design of the quench protection system, e.g., avoiding to trigger a fast current discharge right after the disruption, as well as for the machine operation, e.g., assessing the required re-cooling time of the magnets after a disruption.
- 12 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-7
Open AccessAnalysis of the Thermal-Hydraulic Effects of a Plasma Disruption on the DTT TF Magnets
The Divertor Tokamak Test (DTT) facility, a fully superconducting nuclear fusion reactor being built in Italy, will contribute to address the power exhaust problem in EU DEMO perspective. A lot of flexibility of operation will be demanded to the machine, which should be capable to tackle also severe transients such as plasma disruptions. In this work, the 4C thermal-hydraulic code is used to compute the temperature margin during a plasma disruption, using as input the heat generated into the Toroidal Field coil casing and transferred to the winding pack, and the possibility that this leads to a quench of the magnet is studied. The results of the analysis will give important feedbacks for the design of the quench protection system, e.g., avoiding to trigger a fast current discharge right after the disruption, as well as for the machine operation, e.g., assessing the required re-cooling time of the magnets after a disruption.
- 6 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Electromagnetic Analysis of DTT Poloidal Field Coils During an Electrical Transient
The magnetic system of the Divertor Tokamak Test facility (DTT), comprising all the superconducting poloidal coils, is an important part of the machine. It is composed of several parts mutually coupled among them: six Central Solenoid (CS) coils, six Poloidal Field (PF) coils, the passive structures and the plas-ma. This implies that a current variation in any poloidal coil (CS or PF) can cause a significant current or voltage variation in the others, as well as a change of the plasma current. In particular, during a major plasma disruption, the magnetic flux in the to-kamak changes rapidly producing over-voltage and/or over-current in each poloidal coil, and can be at the origin of severe damage to the components. The assessment of the overvoltage oc-curring in each poloidal coil has been carried out by an electro-magnetic analysis in Ansys environment, step-by-step. Different initial conditions were considered for electromagnetic analysis and two possible electrical transients were simulated: a Break-down event and a major plasma disruption. The Finite Element Model (FEM), the concentrated parameters circuit and the simu-lation results are here described and presented.
- 6 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Electromagnetic Analysis of DTT Poloidal Field Coils During an Electrical Transient
The magnetic system of the Divertor Tokamak Test facility (DTT), comprising all the superconducting poloidal coils, is an important part of the machine. It is composed of several parts mutually coupled among them: six Central Solenoid (CS) coils, six Poloidal Field (PF) coils, the passive structures and the plas-ma. This implies that a current variation in any poloidal coil (CS or PF) can cause a significant current or voltage variation in the others, as well as a change of the plasma current. In particular, during a major plasma disruption, the magnetic flux in the to-kamak changes rapidly producing over-voltage and/or over-current in each poloidal coil, and can be at the origin of severe damage to the components. The assessment of the overvoltage oc-curring in each poloidal coil has been carried out by an electro-magnetic analysis in Ansys environment, step-by-step. Different initial conditions were considered for electromagnetic analysis and two possible electrical transients were simulated: a Break-down event and a major plasma disruption. The Finite Element Model (FEM), the concentrated parameters circuit and the simu-lation results are here described and presented.