Surjit Singh Katoch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Surjit Singh Katoch has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Deepak Kumar
6 shared publications- Naveen Kumar Chaturvedi
Department of Civil Engineering, Anurag University, Hyderabad, India
4 shared publications - Mukul Bajpai
Indian Institute of Technology Bombay
3 shared publications - Vineet Kumar
Indian Institute of Technology Roorkee
2 shared publications - Deepak Kumar
School of Ecology and Environment Studies, Nalanda University
1 shared publication - Manjari Singh
Structural Engineering Department, Veermata Jijabai Technological Institute, Mumbai, India
1 shared publication
Latest Publications
- 1 December 2020
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 92, 101-108
Evaluation and comparison of Fenton-like oxidation with Fenton’s oxidation for hazardous methoxyanilines in aqueous solution
- 1 December 2020
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 92, 101-108
Evaluation and comparison of Fenton-like oxidation with Fenton’s oxidation for hazardous methoxyanilines in aqueous solution
- 23 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 42040-42050
Optimization and economical study of electro-coagulation unit using CCD to treat real graywater and its reuse potential
The reclamation of graywater for non-potable purposes has attained utmost importance, particularly in developing nations. The present research aimed to evaluate the optimal condition of electro-coagulation system in treatment of graywater and its reuse. Moreover, the study also evaluates the impact of major operating parameters on pollutant removal and anode dissolution. To achieve this, two-factor (voltage potential and time) and 5-level (− 1, − 0.5, 0, + 0.5, and + 1) full factorial design, based on response surface methodology (RSM) has been executed for the actual design. The data were acquired after conducting 20 experiments, as suggested by RSM (response surface methodology). Design Expert 12.0.8.0 software has been used to design mathematical model to obtain optimum condition (14 V and 47 min) at pH of 7.35, which provides experimental removal efficiency (75.6% chemical oxygen demand, 78.7% total dissolved solids, 93.4% turbidity, and 63.2% chloride) with minimal electrode consumption of 1.38 mg L−1. Adequacy of the model developed has been verified by ANOVA. The operating cost of treating graywater at the optimized condition obtained as 0.7 US$/kg COD.
- 23 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 42040-42050
Optimization and economical study of electro-coagulation unit using CCD to treat real graywater and its reuse potential
The reclamation of graywater for non-potable purposes has attained utmost importance, particularly in developing nations. The present research aimed to evaluate the optimal condition of electro-coagulation system in treatment of graywater and its reuse. Moreover, the study also evaluates the impact of major operating parameters on pollutant removal and anode dissolution. To achieve this, two-factor (voltage potential and time) and 5-level (− 1, − 0.5, 0, + 0.5, and + 1) full factorial design, based on response surface methodology (RSM) has been executed for the actual design. The data were acquired after conducting 20 experiments, as suggested by RSM (response surface methodology). Design Expert 12.0.8.0 software has been used to design mathematical model to obtain optimum condition (14 V and 47 min) at pH of 7.35, which provides experimental removal efficiency (75.6% chemical oxygen demand, 78.7% total dissolved solids, 93.4% turbidity, and 63.2% chloride) with minimal electrode consumption of 1.38 mg L−1. Adequacy of the model developed has been verified by ANOVA. The operating cost of treating graywater at the optimized condition obtained as 0.7 US$/kg COD.
- 4 July 2020
- Published by Wiley in Water Environment Research
- Vol. 92 (12) , 2140-2154
Techno‐economical optimization using Box–Behnken (BB) design for chemical oxygen demand and chloride reduction from hospital wastewater by electro‐coagulation
The study examines the optimum condition of an electro‐coagulation (EC) unit for treatment of hospital wastewater (HWW) using iron (Fe) electrodes. The impact of factors such as pH, current, and electrolysis time on COD, chloride, and anode dissolution was investigated. For this purpose, Box–Behnken (BB) design based on the response surface methodology (RSM) was used to design and analyze the results. The predicted value of chemical oxygen demand (COD) and chloride removal at optimum conditions (pH: 7.41, current: 2.64 A and electrolysis time: 41.31 min) were 92.81% and 71.23%, respectively. At same optimum conditions, the value of energy and electrode consumption per kg of COD was 0.06376 kWh/kg COD and 1.362 kg/kg COD, respectively. High value of R2 (i.e., R2 > 99%) for all three responses (Y1, Y2, and Y3) obtained from ANOVA confirms that the proposed model is valid, accurate, and acceptable. The kinetic study shows linear relationship and follows pseudo‐first‐order kinetics. Pareto graph shows that the percentage impact of current factor on COD and chloride removal was maximum, that is, 54.984% and 66.79%, respectively. Lastly, the total cost of EC treatment was calculated in terms of COD removal and was found to be 55.47 ₹/kg COD.Practitioner points: Using Fe electrode results in 92.81% COD and 71.23% Chloride removal, respectively. High value of R2 > 99% for all three responses from ANOVA confirms the proposed model is valid. Pareto analysis shows current factor has maximum percentage impact on pollutant removal. Kinetic study shows linear relationship and follows pseudo‐first‐order kinetics.
- 4 July 2020
- Published by Wiley in Water Environment Research
- Vol. 92 (12) , 2140-2154
Techno‐economical optimization using Box–Behnken (BB) design for chemical oxygen demand and chloride reduction from hospital wastewater by electro‐coagulation
The study examines the optimum condition of an electro‐coagulation (EC) unit for treatment of hospital wastewater (HWW) using iron (Fe) electrodes. The impact of factors such as pH, current, and electrolysis time on COD, chloride, and anode dissolution was investigated. For this purpose, Box–Behnken (BB) design based on the response surface methodology (RSM) was used to design and analyze the results. The predicted value of chemical oxygen demand (COD) and chloride removal at optimum conditions (pH: 7.41, current: 2.64 A and electrolysis time: 41.31 min) were 92.81% and 71.23%, respectively. At same optimum conditions, the value of energy and electrode consumption per kg of COD was 0.06376 kWh/kg COD and 1.362 kg/kg COD, respectively. High value of R2 (i.e., R2 > 99%) for all three responses (Y1, Y2, and Y3) obtained from ANOVA confirms that the proposed model is valid, accurate, and acceptable. The kinetic study shows linear relationship and follows pseudo‐first‐order kinetics. Pareto graph shows that the percentage impact of current factor on COD and chloride removal was maximum, that is, 54.984% and 66.79%, respectively. Lastly, the total cost of EC treatment was calculated in terms of COD removal and was found to be 55.47 ₹/kg COD.Practitioner points: Using Fe electrode results in 92.81% COD and 71.23% Chloride removal, respectively. High value of R2 > 99% for all three responses from ANOVA confirms the proposed model is valid. Pareto analysis shows current factor has maximum percentage impact on pollutant removal. Kinetic study shows linear relationship and follows pseudo‐first‐order kinetics.
- Open Access
- 1 March 2020
- Published by Environmental Health Perspectives in Journal of Health and Pollution
- Vol. 10 (25) , 200302
Remedial Technologies for Aniline and Aniline Derivatives Elimination from Wastewater
Background. Aniline and its derivatives are widely used as intermediate chemicals in the pharmaceutical and dye industries and are present in their wastewaters. These chemicals are of concern due t...
- 1 March 2020
- Published by Environmental Health Perspectives in Journal of Health and Pollution
- Vol. 10 (25) , 200302
Open AccessRemedial Technologies for Aniline and Aniline Derivatives Elimination from Wastewater
Background. Aniline and its derivatives are widely used as intermediate chemicals in the pharmaceutical and dye industries and are present in their wastewaters. These chemicals are of concern due t...
- 1 December 2019
- Published by IWA Publishing in Water Science & Technology
- Vol. 80 (11) , 2091-2106
Comparative study on decentralized treatment technologies for sewage and graywater reuse – a review
In present scenario, the demand of fresh water from reservoirs like lakes, rivers, etc., are overloaded due to rapid industrialization and population explosion and also the effluents from industries and domestic wastewater are continuously polluting these resources. To address this issue, several decentralized wastewater treatment system (DWTS) were installed all over the globe to reuse and recycle wastewater/greywater for non-potable motives such as fire protection, toilet-flushing, landscape irrigation, etc. In this review, the comparison between different DWTS was carried out to evaluate their performance, merits and limitations. Hybrid technologies like Electrically-Enhanced Biomass Concentrator Reactor (E2BCR) and integration of physical/ biological methods with bio-electrochemical system (BES) such as Microbial Fuel Cells (MFCs) were found to be most promising way for near complete removal of pollutants from wastewater and also the issue of membrane fouling was reduced to a good extent.
- 1 December 2019
- Published by IWA Publishing in Water Science & Technology
- Vol. 80 (11) , 2091-2106
Comparative study on decentralized treatment technologies for sewage and graywater reuse – a review
In present scenario, the demand of fresh water from reservoirs like lakes, rivers, etc., are overloaded due to rapid industrialization and population explosion and also the effluents from industries and domestic wastewater are continuously polluting these resources. To address this issue, several decentralized wastewater treatment system (DWTS) were installed all over the globe to reuse and recycle wastewater/greywater for non-potable motives such as fire protection, toilet-flushing, landscape irrigation, etc. In this review, the comparison between different DWTS was carried out to evaluate their performance, merits and limitations. Hybrid technologies like Electrically-Enhanced Biomass Concentrator Reactor (E2BCR) and integration of physical/ biological methods with bio-electrochemical system (BES) such as Microbial Fuel Cells (MFCs) were found to be most promising way for near complete removal of pollutants from wastewater and also the issue of membrane fouling was reduced to a good extent.
- Open Access
- 30 November 2019
- Published by Springer Nature in Applied Water Science
- Vol. 10 (1) , 18
Effect of various parameters during degradation of toxic p-anisidine by Fenton’s oxidation
p-Anisidine being a component of wastewater generated through dye and pharmaceutical industries is highly toxic and carcinogenic in nature. Therefore, its presence in wastewater requires prior treatment before its disposal from the point of safety of human and aquatic life. Fenton’s oxidation is a type of advanced oxidation processes which is efficient, ecofriendly and reliable, and this was not studied for the removal of p-anisidine from wastewater. In this study, the effect of influent pH, hydrogen peroxide (H2O2) concentration and ferrous ion (Fe2+) concentration on the removal of p-anisidine by Fenton’s reagent was carried out on a laboratory scale. All samples were examined for initial and final concentrations of p-anisidine using UV–Vis spectrophotometry, and also initial and final COD was analyzed. p-Anisidine shows maximum absorbance at 296 nm. At pH 2.5 and [H2O2]/[Fe2+] of 70:1 for the initial p-anisidine concentration of 0.5 mM and for 24 h reaction time, the maximum removal of p-anisidine was found to be 88.95% and maximum COD removal was 76.43%.
- 30 November 2019
- Published by Springer Nature in Applied Water Science
- Vol. 10 (1) , 18
Open AccessEffect of various parameters during degradation of toxic p-anisidine by Fenton’s oxidation
p-Anisidine being a component of wastewater generated through dye and pharmaceutical industries is highly toxic and carcinogenic in nature. Therefore, its presence in wastewater requires prior treatment before its disposal from the point of safety of human and aquatic life. Fenton’s oxidation is a type of advanced oxidation processes which is efficient, ecofriendly and reliable, and this was not studied for the removal of p-anisidine from wastewater. In this study, the effect of influent pH, hydrogen peroxide (H2O2) concentration and ferrous ion (Fe2+) concentration on the removal of p-anisidine by Fenton’s reagent was carried out on a laboratory scale. All samples were examined for initial and final concentrations of p-anisidine using UV–Vis spectrophotometry, and also initial and final COD was analyzed. p-Anisidine shows maximum absorbance at 296 nm. At pH 2.5 and [H2O2]/[Fe2+] of 70:1 for the initial p-anisidine concentration of 0.5 mM and for 24 h reaction time, the maximum removal of p-anisidine was found to be 88.95% and maximum COD removal was 76.43%.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Environment and Waste Management
- Vol. 19 (1) , 42
Policies and practices of biomedical waste management in different healthcare facilities in a developing country
Improperly managed biomedical wastes is harmful to both, the personnel dealing with it and the environmental health. In the present study five randomly selected healthcare facilities located in Himachal Pradesh, India were studied for cradle to grave evaluation of biomedical waste. The 872 bedded state medical college and hospital located at the capital city did not appropriately separate the waste especially at the point of generation. While in the regional hospital (210 beds), the colour-coding practices for waste segregation were not observed as per extant rules and guidelines. In the government run TB sanatorium (100 beds) the staff was not very well acquainted with the special categories of waste and its treatment henceforth. In the community and primary health centre, the waste received minimum attention by the producers and its handlers as either they were not aware of the practices or they did not have the resources to manage it.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Environment and Waste Management
- Vol. 19 (1) , 42
Policies and practices of biomedical waste management in different healthcare facilities in a developing country
Improperly managed biomedical wastes is harmful to both, the personnel dealing with it and the environmental health. In the present study five randomly selected healthcare facilities located in Himachal Pradesh, India were studied for cradle to grave evaluation of biomedical waste. The 872 bedded state medical college and hospital located at the capital city did not appropriately separate the waste especially at the point of generation. While in the regional hospital (210 beds), the colour-coding practices for waste segregation were not observed as per extant rules and guidelines. In the government run TB sanatorium (100 beds) the staff was not very well acquainted with the special categories of waste and its treatment henceforth. In the community and primary health centre, the waste received minimum attention by the producers and its handlers as either they were not aware of the practices or they did not have the resources to manage it.
- 1 January 2017
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 67, 173-183
Dams turning devils: An insight into the public safety aspects in operational run of the river hydropower projects in western Himalayas
- 1 January 2017
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 67, 173-183
Dams turning devils: An insight into the public safety aspects in operational run of the river hydropower projects in western Himalayas
- 1 August 2016
- Published by Elsevier in Renewable Energy
- Vol. 93, 599-607
Environmental sustainability of run of the river hydropower projects: A study from western Himalayan region of India
- 1 August 2016
- Published by Elsevier in Renewable Energy
- Vol. 93, 599-607
Environmental sustainability of run of the river hydropower projects: A study from western Himalayan region of India
- 29 September 2015
- Published by Springer Nature in Journal of Mountain Science
- Vol. 12 (5) , 1315-1333
Sustainability assessment and ranking of run of the river (RoR) hydropower projects using analytical hierarchy process (AHP): A study from Western Himalayan region of India
- 29 September 2015
- Published by Springer Nature in Journal of Mountain Science
- Vol. 12 (5) , 1315-1333
Sustainability assessment and ranking of run of the river (RoR) hydropower projects using analytical hierarchy process (AHP): A study from Western Himalayan region of India