Marius Ovidiu Mada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marius Ovidiu Mada has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Pedro Fragoso Costa
Department of Nuclear Medicine, University Hospital Essen, West German Cancer Center (WTZ), University of Duisburg-Essen, Essen, Germany
2 shared publications - Adel Helmy
Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK
1 shared publication - Agata Karolina Pietrzak
Electroradiology Department, Poznan University of Medical Sciences, Poznan, Poland; Nuclear Medicine Department, Greater Poland Cancer Centre, Poznan, Poland
1 shared publication Alexander Hammers
King’s College London, PET Centre, 1st Floor Lambeth Wing, St Thomas’ Hospital, London, UK
1 shared publication- Andrea Greve
Medical Research Council Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK
1 shared publication - Andrea Santos
Hospital CUF Descobertas
1 shared publication
Latest Publications
- 17 July 2024
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 41 (13-14) , 1550-1564
Characterizing Diffusion from Microdialysis Catheters in the Human Brain: A Magnetic Resonance Imaging Study With Gadobutrol
Cerebral microdialysis (CMD) catheters allow continuous monitoring of patients' cerebral metabolism in severe traumatic brain injury (TBI). The catheters consist of a terminal semi-permeable membrane that is inserted into the brain's interstitium to allow perfusion fluid to equalize with the surrounding cerebral extracellular environment before being recovered through a central non-porous channel. However, it is unclear how far recovered fluid and suspended metabolites have diffused from within the brain, and therefore what volume or region of brain tissue the analyses of metabolism represent. We assessed diffusion of the small magnetic resonance (MR)-detectible molecule gadobutrol from microdialysis catheters in six subjects (complete data five subjects, incomplete data one subject) who had sustained a severe TBI. Diffusion pattern and distance in cerebral white matter were assessed using T 1 (time for MR spin-lattice relaxation) maps at 1 mm isotropic resolution in a 3 Tesla MR scanner. Gadobutrol at 10 mmol/L diffused from cerebral microdialysis catheters in a uniform spheroidal (ellipsoid of revolution) pattern around the catheters' semipermeable membranes, and across gray matter-white matter boundaries. Evidence of gadobutrol diffusion was found up to a mean of 13.4 ± 0.5 mm (mean ± standard deviation [SD]) from catheters, but with a steep concentration drop off so that ≤50% of maximum concentration was achieved at ∼4 mm, and ≤10% of maximum was found beyond ∼7 mm from the catheters. There was little variation between subjects. The relaxivity of gadobutrol in human cerebral white matter was estimated to be 1.61 ± 0.38 L.mmol −1 sec −1 (mean ± SD); assuming gadobutrol remained extracellular thereby occupying 20% of total tissue volume (interstitium), and concentration equilibrium with perfusion fluid was achieved immediately adjacent to catheters after 24 h of perfusion. No statistically significant change was found in the concentration of the extracellular metabolites glucose, lactate, pyruvate, nor the lactate/pyruvate ratio during gadobutrol perfusion when compared with period of baseline microdialysis perfusion. Cerebral microdialysis allows continuous monitoring of regional cerebral metabolism—the volume of which is now clearer from this study. It also has the potential to deliver small molecule therapies to focal pathologies of the human brain. This study provides a platform for future development of new catheters optimally designed to treat such conditions.
- 17 July 2024
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 41 (13-14) , 1550-1564
Characterizing Diffusion from Microdialysis Catheters in the Human Brain: A Magnetic Resonance Imaging Study With Gadobutrol
Cerebral microdialysis (CMD) catheters allow continuous monitoring of patients' cerebral metabolism in severe traumatic brain injury (TBI). The catheters consist of a terminal semi-permeable membrane that is inserted into the brain's interstitium to allow perfusion fluid to equalize with the surrounding cerebral extracellular environment before being recovered through a central non-porous channel. However, it is unclear how far recovered fluid and suspended metabolites have diffused from within the brain, and therefore what volume or region of brain tissue the analyses of metabolism represent. We assessed diffusion of the small magnetic resonance (MR)-detectible molecule gadobutrol from microdialysis catheters in six subjects (complete data five subjects, incomplete data one subject) who had sustained a severe TBI. Diffusion pattern and distance in cerebral white matter were assessed using T 1 (time for MR spin-lattice relaxation) maps at 1 mm isotropic resolution in a 3 Tesla MR scanner. Gadobutrol at 10 mmol/L diffused from cerebral microdialysis catheters in a uniform spheroidal (ellipsoid of revolution) pattern around the catheters' semipermeable membranes, and across gray matter-white matter boundaries. Evidence of gadobutrol diffusion was found up to a mean of 13.4 ± 0.5 mm (mean ± standard deviation [SD]) from catheters, but with a steep concentration drop off so that ≤50% of maximum concentration was achieved at ∼4 mm, and ≤10% of maximum was found beyond ∼7 mm from the catheters. There was little variation between subjects. The relaxivity of gadobutrol in human cerebral white matter was estimated to be 1.61 ± 0.38 L.mmol −1 sec −1 (mean ± SD); assuming gadobutrol remained extracellular thereby occupying 20% of total tissue volume (interstitium), and concentration equilibrium with perfusion fluid was achieved immediately adjacent to catheters after 24 h of perfusion. No statistically significant change was found in the concentration of the extracellular metabolites glucose, lactate, pyruvate, nor the lactate/pyruvate ratio during gadobutrol perfusion when compared with period of baseline microdialysis perfusion. Cerebral microdialysis allows continuous monitoring of regional cerebral metabolism—the volume of which is now clearer from this study. It also has the potential to deliver small molecule therapies to focal pathologies of the human brain. This study provides a platform for future development of new catheters optimally designed to treat such conditions.
- Open Access
- 21 October 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (10) , 591
Modified MRI Anonymization (De-Facing) for Improved MEG Coregistration
Localising the sources of MEG/EEG signals often requires a structural MRI to create a head model, while ensuring reproducible scientific results requires sharing data and code. However, sharing structural MRI data often requires the face go be hidden to help protect the identity of the individuals concerned. While automated de-facing methods exist, they tend to remove the whole face, which can impair methods for coregistering the MRI data with the EEG/MEG data. We show that a new, automated de-facing method that retains the nose maintains good MRI-MEG/EEG coregistration. Importantly, behavioural data show that this “face-trimming” method does not increase levels of identification relative to a standard de-facing approach and has less effect on the automated segmentation and surface extraction sometimes used to create head models for MEG/EEG localisation. We suggest that this trimming approach could be employed for future sharing of structural MRI data, at least for those to be used in forward modelling (source reconstruction) of EEG/MEG data.
- 21 October 2022
- Published by MDPI AG in Bioengineering
- Vol. 9 (10) , 591
Open AccessModified MRI Anonymization (De-Facing) for Improved MEG Coregistration
Localising the sources of MEG/EEG signals often requires a structural MRI to create a head model, while ensuring reproducible scientific results requires sharing data and code. However, sharing structural MRI data often requires the face go be hidden to help protect the identity of the individuals concerned. While automated de-facing methods exist, they tend to remove the whole face, which can impair methods for coregistering the MRI data with the EEG/MEG data. We show that a new, automated de-facing method that retains the nose maintains good MRI-MEG/EEG coregistration. Importantly, behavioural data show that this “face-trimming” method does not increase levels of identification relative to a standard de-facing approach and has less effect on the automated segmentation and surface extraction sometimes used to create head models for MEG/EEG localisation. We suggest that this trimming approach could be employed for future sharing of structural MRI data, at least for those to be used in forward modelling (source reconstruction) of EEG/MEG data.
- Open Access
- 6 July 2020
- Published by Springer Nature in European Journal of Hybrid Imaging
- Vol. 4 (1) , 1-20
Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology
The use of hybrid systems is increasingly growing in Europe and this is progressively important for the final result of diagnostic tests. As an integral part of the hybrid imaging system, computed tomography (CT) plays a crucial role in myocardial perfusion imaging diagnostics. Throughout Europe, a variety of equipment is available and also different university curricula of the nuclear medicine technologist are observed. Hence, the Technologist Committee of the European Association of Nuclear Medicine proposes to identify, through a bibliographic review, the recommendations for best practice in computed tomography applied to attenuation correction and calcium score in myocardial perfusion imaging, which courses in the set of knowledge, skills, and competencies for nuclear medicine technologists. This document aims at providing recommendations for CT acquisition protocols and CT image optimization in nuclear cardiology.
- 6 July 2020
- Published by Springer Nature in European Journal of Hybrid Imaging
- Vol. 4 (1) , 1-20
Open AccessBest practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology
The use of hybrid systems is increasingly growing in Europe and this is progressively important for the final result of diagnostic tests. As an integral part of the hybrid imaging system, computed tomography (CT) plays a crucial role in myocardial perfusion imaging diagnostics. Throughout Europe, a variety of equipment is available and also different university curricula of the nuclear medicine technologist are observed. Hence, the Technologist Committee of the European Association of Nuclear Medicine proposes to identify, through a bibliographic review, the recommendations for best practice in computed tomography applied to attenuation correction and calcium score in myocardial perfusion imaging, which courses in the set of knowledge, skills, and competencies for nuclear medicine technologists. This document aims at providing recommendations for CT acquisition protocols and CT image optimization in nuclear cardiology.
- Open Access
- 23 January 2020
- Published by Springer Nature in European Journal of Hybrid Imaging
- Vol. 4 (1) , 1-12
Competencies and training of radiographers and technologists for PET/MR imaging - a study from the UK MR-PET network
Background: After the success of PET/CT as a clinical diagnostic tool, the introduction of PET/MRI is a natural development aimed at further improving combined diagnostic imaging and reduced ionising radiation dose for half-body imaging. As with PET and CT, the combination of PET and MRI presents a series of issues that need to be addressed regarding workforce training and education. At present, there is a lack of agreement over the competencies, training requirements and educational pathways needed for PET/MRI operation. In the UK, following the establishment of the MR-PET imaging network, a task force was created to investigate the status of the workforce training, identify gaps and make recommendations regarding staff training. To do this, we ran a national survey on the status of the workforce training and the local practices across the UK’s seven PET/MRI sites, reviewed the literature, and convened a panel of experts, to assess all the evidence and make recommendations regarding PET/MRI competencies and training of nuclear medicine technologists and radiographers. Results: There is limited literature available specifically on competencies and training for technologists and radiographers. The recommendations on the topic needed revisiting and adapting to the UK MR-PET network. The online survey confirmed the need for developing PET/MRI competencies and training pathways. Local organisational structures and practices were shared across the seven sites, based on models derived from experience outside the UK. The panel of experts agreed on the need for PET/MRI competencies and training strategies. Professional organisations started collaborative discussions with partners from both Nuclear Medicine and Radiography to set training priorities. Multidisciplinary collaboration and partnership were suggested as a key to a successful implementation of competencies and training. Conclusions: The report identified the need for establishing competencies for the PET/MRI workforce, particularly for technologists and radiographers. It also helped defining these competencies as well as identifying the demand for bespoke training and the development of local and national courses to be implemented to fulfil this new training need.
- 23 January 2020
- Published by Springer Nature in European Journal of Hybrid Imaging
- Vol. 4 (1) , 1-12
Open AccessCompetencies and training of radiographers and technologists for PET/MR imaging - a study from the UK MR-PET network
Background: After the success of PET/CT as a clinical diagnostic tool, the introduction of PET/MRI is a natural development aimed at further improving combined diagnostic imaging and reduced ionising radiation dose for half-body imaging. As with PET and CT, the combination of PET and MRI presents a series of issues that need to be addressed regarding workforce training and education. At present, there is a lack of agreement over the competencies, training requirements and educational pathways needed for PET/MRI operation. In the UK, following the establishment of the MR-PET imaging network, a task force was created to investigate the status of the workforce training, identify gaps and make recommendations regarding staff training. To do this, we ran a national survey on the status of the workforce training and the local practices across the UK’s seven PET/MRI sites, reviewed the literature, and convened a panel of experts, to assess all the evidence and make recommendations regarding PET/MRI competencies and training of nuclear medicine technologists and radiographers. Results: There is limited literature available specifically on competencies and training for technologists and radiographers. The recommendations on the topic needed revisiting and adapting to the UK MR-PET network. The online survey confirmed the need for developing PET/MRI competencies and training pathways. Local organisational structures and practices were shared across the seven sites, based on models derived from experience outside the UK. The panel of experts agreed on the need for PET/MRI competencies and training strategies. Professional organisations started collaborative discussions with partners from both Nuclear Medicine and Radiography to set training priorities. Multidisciplinary collaboration and partnership were suggested as a key to a successful implementation of competencies and training. Conclusions: The report identified the need for establishing competencies for the PET/MRI workforce, particularly for technologists and radiographers. It also helped defining these competencies as well as identifying the demand for bespoke training and the development of local and national courses to be implemented to fulfil this new training need.