Gilbert Blaise
Research Subjects
Gilbert Blaise has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bernard Vinet
1 shared publicationEric Troncy
1 shared publicationFan Yang
Department of Anesthesia, Hôpital Notre-Dame, Université de Montréal, QC, Canada
1 shared publicationGuy Czaika
1 shared publicationMartin Francœur
1 shared publicationPatrick Vinay
1 shared publication
Latest Publications
- Open Access
- 1 April 1997
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (4) , 657-662
Effects of reducing reagents and temperature on conversion of nitrite and nitrate to nitric oxide and detection of NO by chemiluminescence
To measure the concentration of nitrites and nitrates by chemiluminescence, we examined the efficiency of five reducing agents [V(III), Mo(VI) + Fe(II), NaI, Ti(III), and Cr(III)] to reduce nitrite (NO2−) and (or) nitrate (NO3−) to nitric oxide (NO). The effect of each reducing agent on the conversion of different amounts of NO2− and (or) NO3−(100–500 pmol, representing concentrations of 0.4 to 2 μmolar) to NO was determined at 20 °C for NO2− and at 80 °C for NO3−. The effect of temperature from 20 to 90 °C on the conversion of a fixed amount of NO2− or NO3− (400 pmol or 1.6 μmolar) to NO was also determined. These five reducing agents are similarly efficient for the conversion of NO2− to NO at 20 °C. V(III) and Mo(VI) + Fe(II) can completely reduce NO3− to NO at 80 °C. NaI and Cr(III) were unable to convert NO3− to NO. Increased temperature facilitated the conversion of NO3− to NO, rather than that of NO2− to NO. We evaluated the recovery of NO2− and NO3− from plasmas of pig and of dog. Recovery from plasma of both animals was reproducible and near quantitative.
- 1 April 1997
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 43 (4) , 657-662
Open AccessEffects of reducing reagents and temperature on conversion of nitrite and nitrate to nitric oxide and detection of NO by chemiluminescence
To measure the concentration of nitrites and nitrates by chemiluminescence, we examined the efficiency of five reducing agents [V(III), Mo(VI) + Fe(II), NaI, Ti(III), and Cr(III)] to reduce nitrite (NO2−) and (or) nitrate (NO3−) to nitric oxide (NO). The effect of each reducing agent on the conversion of different amounts of NO2− and (or) NO3−(100–500 pmol, representing concentrations of 0.4 to 2 μmolar) to NO was determined at 20 °C for NO2− and at 80 °C for NO3−. The effect of temperature from 20 to 90 °C on the conversion of a fixed amount of NO2− or NO3− (400 pmol or 1.6 μmolar) to NO was also determined. These five reducing agents are similarly efficient for the conversion of NO2− to NO at 20 °C. V(III) and Mo(VI) + Fe(II) can completely reduce NO3− to NO at 80 °C. NaI and Cr(III) were unable to convert NO3− to NO. Increased temperature facilitated the conversion of NO3− to NO, rather than that of NO2− to NO. We evaluated the recovery of NO2− and NO3− from plasmas of pig and of dog. Recovery from plasma of both animals was reproducible and near quantitative.