ELEunseok Lee

Eunseok Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eunseok Lee has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A 60-GHz Low-Noise mmWave Divider-Less Fractional- N Cascaded PLL Achieving −250.2-dB FoM J in 28-nm CMOS

    by Jaehong Jung, Eunseok Lee, Donghyeon Han, Jinchen Wang, Anantha P. Chandrakasan, Ruonan Han

    This article presents a fractional- ${ {N}}$ cascaded phase-locked loop (PLL) operating in the mmWave band from 55.8 to 64.2 GHz. The cascaded architecture consists of a first-stage fractional- ${ {N}}$ reference-sampling (RS) PLL and a second-stage sub-sampling (SS) PLL, incorporating two key innovations. The first-stage RS-PLL leverages a fully differential voltage-domain quantization-noise cancellation (FDVD-QNC) scheme to suppress the quantization noise of the delta–sigma modulator. The proposed FDVD-QNC, implemented through two sequential steps—bottom-plate voltage switching of the sampling capacitor and intentional offset voltage control of the transconductance cell—achieves a resolution of 0.08 mV with an integral nonlinearity (INL) within 1 LSB, while consuming only 0.64 mW. Moreover, its differential topology minimizes susceptibility to external noise sources and doubles the gain of the sampling phase detector (PD). As a result, the first-stage RS-PLL achieves $48.4~\text {fs}_{\text {rms}}$ jitter and a fractional spur of −62.8 dBc with only 14.2 mW of power. Next, to enable reliable frequency acquisition in the second-stage SS-PLL, a frequency-locked loop (FLL) based on a switched-capacitor (SC) frequency-to-voltage converter (FVC) is proposed. The SC-FVC realizes a mmWave divider-less FLL by converting frequency into voltage, thereby eliminating the need for a bulky and power-hungry mmWave divider. The SC-FVC-based FLL consumes 0.84 mW and achieves frequency acquisition within 448 ns without harmonic lock in the SS-PLL. The cascaded PLL is fabricated in a 28-nm CMOS process and occupies an active area of 0.33 mm2. It achieves $58.4~\text {fs}_{\text {rms}}$ jitter with 28.4 mW, corresponding to a $\text {FoM}\!_{\text {J}}$ of −250.2 dB.


  • A Fully-Integrated Wireless Ingestible CMOS Drug-Delivery Chip With Electrochemical Energy Harvesting and pH-Adaptive MPPT for Personalized Therapeutics

    by So-Yoon Yang, Deniz Umut Yildirim, Saransh Sharma, Donghyeon Han, Rishabh Mittal, Husna T. Ellis, Jaehong Jung, Eunseok Lee, Yubin Cai, Giovanni Traverso, et al.

    The rapid growth of personalized medicine has driven increased demand for battery-free, energy-efficient ingestible electronics for on-demand gastrointestinal (GI) drug delivery. This article presents the first fully-integrated, battery-free ingestible CMOS platform that harvests energy from a galvanic cell (GC) through a reconfigurable switched-capacitor converter, with pH-adaptive maximum power point tracking (MPPT) guided by on-chip gastric pH measurement. The system offers three clinically relevant drug-delivery modes, selectable via 13.56 MHz wireless RF commands: burst, low-energy dissolve, and balanced modes. Upon receiving a drug-delivery command, the system applies an optimal voltage bias according to the measured pH and selected delivery mode, to electrochemically dissolve a metal membrane and release the payload. Fabricated in a 65-nm CMOS, the 6-mm2 chip integrates with a drug-delivery chamber, GC, and off-chip antenna to form a capsule that fits within the dimensions of commercial ingestible electronics. Ex vivo and in vitro tests demonstrate reliable system operation, with a 6-cm RF detection range from the tissue surface, 0.32-pH sensor resolution, and 72% end-to-end energy-harvesting efficiency with a wide range of input powers from 30 to $200~\mu $ W. By integrating pH-adaptive MPPT with RF-controlled multimode drug release on a single platform, this work advances adaptable, responsive, and patient-specific therapies for GI drug delivery.


  • A 1.54-mm2, 264-GHz Wake-Up Receiver With Integrated Cryptographic Authentication for Ultra-Miniaturized Platforms

    by Eunseok Lee, Muhammad Ibrahim Wasiq Khan, Xibi Chen, Utsav Banerjee, Nathan Monroe, Rabia Tugce Yazicigil, Ruonan Han, Anantha P. Chandrakasan

    This article presents the first sub-terahertz (sub-THz) wake-up receiver (WuRx) for ultra-miniaturized, massively deployable platforms. A detector-first architecture, utilizing a pseudo-differential cold-FET-based CMOS THz detector, is employed to reduce power consumption. The THz front end employs a dual-antenna-feed detector topology, independently driving the gate and drain of a transistor, thus achieving the optimal conditions of the device for low noise-equivalent power (NEP). In addition, the WuRx incorporates a low-power cryptographic authentication engine to enhance security, preventing the denial-of-sleep (DoSL) attacks through token randomization in a lightweight cryptographic algorithm. Implemented in a 65-nm CMOS process, the 264-GHz system, including four on-chip patch antennas, occupies an area of 1.54 mm2. It achieves a sensitivity of −48 dBm while consuming 2.9- $\mu \text{W}$ dc power in the continuous mode. Wireless tests with multi-meter range and electrical beam-steering operation of sub-THz transponder are provided to demonstrate the feasibility of THz connectivity for the next-generation Internet of Things (IoT).


  • Open Access

    Design of Reconfigurable Time-to-Digital Converter Based on Cascaded Time Interpolators for Electrical Impedance Spectroscopy

    by Sounghun Shin, Yoontae Jung, Soon-Jae Kweon, Eunseok Lee, Jeong-Ho Park, Jinuk Kim, Hyung-Joun Yoo, Minkyu Je

    This paper presents a reconfigurable time-to-digital converter (TDC) used to quantize the phase of the impedance in electrical impedance spectroscopy (EIS). The TDC in the EIS system must handle a wide input-time range for analysis in the low-frequency range and have a high resolution for analysis in the high-frequency range. The proposed TDC adopts a coarse counter to support a wide input-time range and cascaded time interpolators to improve the time resolution in the high-frequency analysis without increasing the counting clock speed. When the same large interpolation factor is adopted, the cascaded time interpolators have shorter measurement time and smaller chip area than a single-stage time interpolator. A reconfigurable time interpolation factor is adopted to maintain the phase resolution with reasonable measurement time. The fabricated TDC has a peak-to-peak phase error of less than 0.72° over the input frequency range from 1 kHz to 512 kHz and the phase error of less than 2.70° when the range is extended to 2.048 MHz, which demonstrates a competitive performance when compared with previously reported designs.


  • A Level Shifter for CMRR-Enhanced Biopotential Acquisition Systems with Human-Body-Coupled Floating Supply Domain

    by Eunseok Lee, Doojin Jang, Minkyu Je

    A new level shifter (LS) is presented for logic voltage translation from human-body-coupled floating supply domain (HBCF-SD) to normal fixed supply domain (NF-SD). The LS utilizes diode-connected loads in the latch to deal with the HBCF supply and employs a preamplification stage to increase tolerable input common-mode voltage (ICMV) range significantly with high energy efficiency. The LS is designed in 0.18-µm process to convert the signal with a swing of 0.45 to 1 V in the HBCF-SD to the signal with a swing of 1.8 V in the NF-SD. The post-layout simulation results show that the LS operates properly even with a 1-V pp variation of the ICMV and maintains consistent performance.

  • A Sleep Apnea Monitoring IC for Respiration, Heart-Rate, SpO2 and Pulse-Transit Time Measurement Using Thermistor, PPG and Body-Channel Communication

    by Dong-Hee Kim, Eunseok Lee, Jihwan Kim, Pangi Park, Seong Hwan Cho

    This paper presents a low power bio-signal acquisition system for sleep apnea, which can measure respiration, heart rate, SpO2, and pulse transit time (PTT). For respiration, a nasal airflow sensor with a thermistor is used. For PTT that can serve as a surrogate for blood pressure during sleep, two photoplethysmogram (PPG) sensors are employed at the upper arm and the finger. For improved comfort during sleep, body channel communication (BCC) is used to remove long wires. To reduce power consumption and circuit complexity, sensor’s analog front-end is implemented by using a current-controlled oscillator which is also shared by BCC transmitter that employs analog frequency modulation. Implemented in 0.18 μm CMOS, the proposed IC consumes less than 3.6 mW from a 1.8 V supply, while occupying 0.145 mm2 of active area.