ZFZhihe Fu

Zhihe Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhihe Fu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low-profile, Broadband, and High-gain Circularly Polarized Metasurface Antenna using Characteristic Mode Analysis

    by Yibiao Fan, Zhan Jin, Zhihe Fu, Xiaowei Cai, Qi Lin

    In this paper, a low-profile broadband and high-gain circularly polarized (CP) metasurface antenna (MSA) is proposed. The characteristic mode analysis is employed to select the valuable modes for the 4×4 square metasurface elements printed on the top of the single-layer dielectric slab. The coplanar waveguide feeding structure combines a horizontal aperture and two slots rotated in a counter-clockwise direction is utilized to excite the CP radiation of the MSA. The proposed CP MSA is fabricated and measured, which achieves a -10 dB impedance bandwidth ranging from 4.83 GHz to 6.35 GHz, with a fractional bandwidth of 27.2%, the overlapped 3 dB axial ratio (AR) bandwidth is 20.1% (covers from 4.83 GHz to 5.91 GHz). Furthermore, the peak boresight gain measured at 5.2 GHz reaches 9.88 dBic. The average gain consistently maintains 8.94 dBic throughout the overlapped AR bandwidth, while the 3 dB gain bandwidth fully encompasses the entirety of the 3 dB overlapped AR bandwidth showing good performance for 5G Wi-Fi band utilization.

  • Open Access

    Research on Circulating Current Suppression Control of Parallel Inverters

    by Yibiao Fan, Lixia Tong, Xiaoping Wang, Xiaowei Cai, Zhihe Fu, Junhui Zhou, Shuangmao Huang, Xingkui Mao

    Circulating current suppression can effectively improve the reliability and redundancy of parallel inverter systems. The mechanism and influencing factors of the low- and high-frequency zero-sequence circulating current (ZSCC) are analyzed in this study. Based on a mechanism analysis and the built mathematical model, the composite control strategy of zero-sequence voltage difference (ZSVD) compensation and virtual inductance is proposed to suppress the low- and high-frequency ZSCC. In the composite control strategy, the low-frequency ZCSS (LF-ZCSS) is suppressed by the ZSVD compensation method, and the HF-ZCSS is suppressed by the virtual inductance method. The ZSVD compensation is incorporated into the SVPWM as an input to regulate the modulation and suppress the LF-ZCSS, and virtual inductance is introduced into the current control loop to suppress the HF-ZCSS. A parallel system prototype composed of two 6 kW inverters is constructed. The experiments show that the ZSCC of the parallel system is reduced by 45%, which verifies the effectiveness of the proposed composite control strategy.


  • Open Access

    High-Switching-Frequency SiC Power Conversion Systems with Improved Finite Control Set Method Prediction Control

    by Yibiao Fan, Lixia Tong, Yingjie Lu, Xiaowei Cai, Zhihe Fu, Xingkui Mao

    With the development of power conversion systems or bidirectional grid-connected inverters characterized by high DC voltage, high efficiency, and high-power density, high-switching-frequency SiC power switches are being widely used, and these require a short computational time of control algorithm. Based on the sector judgment of a space voltage vector and the midpoint potential control balancing of a DC bus, an improved finite control set method prediction control (FCS-MPC) method was proposed for a T-type three-level PCS. This improved FCS-MPC first judges the sector of the space voltage vector and locates the position of the corresponding large sector according to phase lock information; then, it analyzes the sampled voltage of the upper and lower bus capacitors to obtain the midpoint potential situation and selects appropriate small vectors based on the midpoint potential situation. This simple improved strategy can reduce the computational complexity of traditional MPC for rolling optimization, resulting in a reduction in the vectors from 27 to 8. A SiC-based 10 kW bidirectional PCS prototype verified the improved FCS-MPC, and the computational time was reduced about by 56% in comparison to traditional FCS-MPC.


  • Open Access

    Energy-Feedback Load Simulation Algorithm Based on Fuzzy Control

    by Xiaowei Cai, Zhihe Fu, Huangsheng Xie, Jiaxiang Xue, Haisong Luo, Ning Ou, Gang Zhou

    In order to solve the problem that the traditional Proportional Integral (PI) controller cannot take into account both response speed and input current overshoot and cannot adapt to complex working conditions, an energy-feedback DC load simulation control algorithm based on fuzzy control was proposed. By adding a fuzzy adaptive PI setting to the traditional load simulation control algorithm, the dynamic response performance of the system and the accuracy of load simulation were improved. A small-signal model of a load analog boost circuit was established based on the state average method. Based on the phase margin, the PI parameter setting of series correction was completed, and the corresponding fuzzy control rules were formulated to identify the response state. Simulation results show that the regulation time of constant current load simulation based on a fuzzy control strategy is shortened by 75.2%, the steady-state error is reduced by 60%, and the overshoot is reduced from 28.3% to 7.47%. The prototype test results show that the maximum relative error of input current load simulation is only 4.50%, and the system response speed can meet the requirements of variable load simulation. The results show that the load simulation control algorithm based on fuzzy control has the characteristics of high precision and excellent dynamic characteristics.


  • Open Access

    Resonant Power Supply for Plasma Cleaning Based on Fuzzy Logic Power Tracking

    by Xiaowei Cai, Zhihe Fu, Huangsheng Xie, Jiaxiang Xue, Duhan Ding, Ning Ou, Gang Zhou

    The coaxial cylindrical reactor with a rotary nozzle is proposed to be used as the plasma torch of the plasma cleaning machine. The phase-shifted full bridge series resonance circuit is used as the power circuit topology. Because the voltage source load resonance circuit technology is mature, the cycle and difficulty of research and development on this basis are relatively small, and the corresponding control strategy and algorithm are relatively easy to achieve. At the same time, the voltage source circuit is smaller than the current source circuit, in line with the development trend of plasma cleaning equipment. In this paper, based on the phase shift full bridge series resonant circuit, the control strategy is compared and analyzed. Considering the response speed, control precision and efficiency, a PSPWM-PFM (Phase Shift Pulse Width Modulation- Pulse Frequency Modulation) hybrid modulation control strategy is proposed, which makes the system not only have a fast response speed but can also construct a soft switch and has a high efficiency. A maximum power tracking algorithm based on a fuzzy PFM was proposed to solve the problem that the plasma power supply deviated from the resonant frequency point easily due to environmental perturbation, and thus deviated from the maximum power point.


  • Open Access

    Research on Improved Deadbeat Control Strategy Based on Interpolation Prediction and Online Inductance Identification

    by Zhihe Fu, Huangsheng Xie, Jiaxiang Xue, Haisong Luo, Zhuangbin Lin

    Aiming at the problem of control delay and inductance deviation, which exist in the traditional deadbeat control of the full-bridge circuit, an improved deadbeat control strategy was proposed. An improved Newton interpolation prediction algorithm was proposed to compensate the delay problem of deadbeat control, and an on-line inductance identification algorithm based on double frequency sampling was proposed to correct the inductance deviation. A mathematical model of deadbeat control for full-bridge inverter was established; besides, the performance of different interpolation prediction algorithms was analyzed. An online inductor identification model is established, on the basis of which the online inductance identification compensation formula is derived. It is indicated that an output constant current of 10 A is available with the deadbeat control relative error of only 0.2%, the grid-connected power factor up to 0.999, and the output current’s total harmonic distortion of only 2.37%. The prototype experiment shows that the output current’s total harmonic distortion is as low as 2.403% and the power factor is as high as 0.998. The results show that the improved deadbeat control strategy can effectively improve the control accuracy and the quality of grid-connected power.


  • Open Access

    Lithium Titanate Battery Management System Based on MPPT and Four-Stage Charging Control for Photovoltaic Energy Storage

    by Zhihe Fu, Yibiao Fan, Xiaowei Cai, Zhaohong Zheng, Jiaxiang Xue, Kun Zhang

    To overcome the unstable photovoltaic input and high randomness in the conventional three-stage battery charging method, this paper proposes a charging control strategy based on a combination of maximum power point tracking (MPPT), and an enhanced four-stage charging algorithm for a photovoltaic power generation energy storage system. This control algorithm ensures that the charging process is not affected by fluctuations in the photovoltaic power. The discharge bus waveform, push–pull discharge load switching waveform, push–pull circuit efficiency, and voltage and current regulation accuracies of the system were investigated. The experimental results show that the charging process is consistent with the designed four-stage charging control algorithm, the voltage and current regulation accuracies satisfy the charging requirements, the busbar remained stable during the battery charging and discharging switch, and the battery balancing effect was good.