SESimone Eder

Simone Eder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simone Eder has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An alternative filament fabrication method as the basis for 3D-printing personalized implants from elastic ethylene vinyl acetate copolymer

    by Bianca Brandl, Simone Eder, Andreas Hirtler, Gloria Khinast, Jeffrey Haley, Christian Schneider, Samuel Theissl, Andreas Bramboeck, Daniel Treffer, Sarah Heupl, et al.

    In this work, a novel tool for small-scale filament production is presented. Unlike traditional methods such as hot melt extrusion (HME), the device (i) allows filament manufacturing from small material amounts as low as three grams, (ii) ensures high diameter stability almost independent of the viscoelastic behavior of the polymer melt, and (iii) enables processing of materials with rheological profiles specifically tailored toward fused filament fabrication (FFF). Hence, novel materials, previously difficult to process due to HME limitations, become easily accessible for FFF for the first time. Here, we showcase the production of highly flexible drug-free, and drug-loaded filaments based on ethylene-vinyl acetate polymers with a vinyl acetate content of 28 w% (EVA28) and unprecedented high melt flow rates of up to 400 g/10 min. Owing to their low viscosity, FFF with low print nozzle sizes of 250 μm was achieved for the first time for EVA28. These small nozzle diameters facilitate 3D-printing of high-resolution structures in small-dimensional dosage forms such as subcutaneous implantable drug delivery systems, which can later be used for personalization. Consequently, the material portfolio for FFF is tremendously broadened, allowing material and formulation optimization toward FFF, independent of a preliminary extrusion process.


  • Toward high-resolution 3D-printing of pharmaceutical implants – A holistic analysis of relevant material properties and process parameters

    by Bianca Brandl, Simone Eder, Anbu Palanisamy, Sarah Heupl, Ivan Terzic, Matthias Katschnig, Thanh Nguyen, Sascha Senck, Eva Roblegg, Martin Spoerk


  • Open Access

    Small-Angle X-ray Scattering (SAXS) Used for the Identification of Nicomorphine Polymorphic Changes at the Early Stage to Avoid Varied Stability and Possible Side Effects

    by Nermina Malanovic, Giovanni Birarda, Simone Eder, Heidrun Gruber-Woelfler, Franz Reiter, Krunoslav Juraic, Aden Hodzic

    In this paper, we present the identification of polymorphisms at an early stage, identified by applying non-standard methods such as SAXS. We provide an analytical approach to polymorphism in the quality/purity of an active pharmaceutical ingredient (API), supplied to a generic company by two different suppliers (i.e., manufacturers). Changes in thermodynamic polymorphism firstly become visible in traces in the larger crystal lattices, which are visible on the SAXS spectrum only using the logarithmic scale, as shown in the result figures. Hence, we are here on the trail of the beginning of a new polymorph in nicomorphine, whose crystal waviness at the early stage is visible only in the additional symmetrical peaks identified and calculated using SAXS, while the chemical analyses excluded all kinds of chemical impurities. The chemical and structural properties were studied using the following techniques: SAXS, WAXS, DSC, dissolution, Raman spectroscopy, and FTIR. Only the SAXS technique could identify crucial differences and calculate the additional signals related to giant crystals, whilst a standard method such as WAXS showed none, and nor did the chemical analyses, such as Raman spectroscopy and FT-IR. This means that due to water in crystallization (known in nicomorphine) or thermodynamic waviness, the formation of the new polymorph starts first in traces, which become visible at larger distances from the crystal lattice, detectible only in the SAXS range. This is a very important premise and hypothesis for further research, and we believe that this work lays a new stone in understanding the origin of new unknown polymorphs and their mixtures. Therefore, the aim of this work is to show that the use of non-standard methods (i.e., SAXS) can be of great benefit to API analysis and the identification of polymorphic changes in the early phase, which can cause varied stability, solubility and bioavailability and thus different therapeutic effects or side effects.


  • Toward a new generation of vaginal pessaries via 3D-printing: Concomitant mechanical support and drug delivery

    by Simone Eder, Laura Wiltschko, Ioannis Koutsamanis, Jesús Alberto Afonso Urich, Florian Arbeiter, Eva Roblegg, Martin Spoerk


  • Open Access

    Development of Porous Polyurethane Implants Manufactured via Hot-Melt Extrusion

    by Ioannis Koutsamanis, Martin Spoerk, Florian Arbeiter, Simone Eder, Eva Roblegg

    Implantable drug delivery systems (IDDSs) offer good patient compliance and allow the controlled delivery of drugs over prolonged times. However, their application is limited due to the scarce material selection and the limited technological possibilities to achieve extended drug release. Porous structures are an alternative strategy that can overcome these shortcomings. The present work focuses on the development of porous IDDS based on hydrophilic (HPL) and hydrophobic (HPB) polyurethanes and chemical pore formers (PFs) manufactured by hot-melt extrusion. Different PF types and concentrations were investigated to gain a sound understanding in terms of extrudate density, porosity, compressive behavior, pore morphology and liquid uptake. Based on the rheological analyses, a stable extrusion process guaranteed porosities of up to 40% using NaHCO3 as PF. The average pore diameter was between 140 and 600 µm and was indirectly proportional to the concentration of PF. The liquid uptake of HPB was determined by the open pores, while for HPL both open and closed pores influenced the uptake. In summary, through the rational selection of the polymer type, the PF type and concentration, porous carrier systems can be produced continuously via extrusion, whose properties can be adapted to the respective application site.


  • Open Access

    Novel Cleaning-in-Place Strategies for Pharmaceutical Hot Melt Extrusion

    by Martin Spoerk, Ioannis Koutsamanis, Josip Matić, Simone Eder, Carolina Patricia Alva Zúñiga, Johannes Poms, Jesús Alberto Afonso Urich, Raymar Andreína Lara García, Klaus Nickisch, Karin Eggenreich, et al.

    To avoid any type of cross-contamination, residue-free production equipment is of utmost importance in the pharmaceutical industry. The equipment cleaning for continuous processes such as hot melt extrusion (HME), which has recently gained popularity in pharmaceutical applications, necessitates extensive manual labour and costs. The present work tackles the HME cleaning issue by investigating two cleaning strategies following the extrusion of polymeric formulations of a hormonal drug and for a sustained release formulation of a poorly soluble drug. First, an in-line quantification by means of UV–Vis spectroscopy was successfully implemented to assess very low active pharmaceutical ingredient (API) concentrations in the extrudates during a cleaning procedure for the first time. Secondly, a novel in-situ solvent-based cleaning approach was developed and its usability was evaluated and compared to a polymer-based cleaning sequence. Comparing the in-line data to typical swab and rinse tests of the process equipment indicated that inaccessible parts of the equipment were still contaminated after the polymer-based cleaning procedure, although no API was detected in the extrudate. Nevertheless, the novel solvent-based cleaning approach proved to be suitable for removing API residue from the majority of problematic equipment parts and can potentially enable a full API cleaning-in-place of a pharmaceutical extruder for the first time.