Kosuke Iwano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kosuke Iwano has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Tsuyoshi Hayashi
Center for Gastroenterology, Teine Keijinkai Hospital, Sapporo, Japan
14 shared publications - Tatsuya Ishii
Center for Gastroenterology, Teine Keijinkai Hospital, Sapporo, Japan
12 shared publications Akio Katanuma
Center for Gastroenterology Teine Keijinkai Hospital Sapporo Hokkaido Japan
11 shared publications- Haruka Toyonaga
Department of Gastroenterology and Hepatology Kansai Medical University Medical Center Osaka Japan
11 shared publications Kuniyuki Takahashi
Center for Gastroenterology Teine Keijinkai Hospital Sapporo Hokkaido Japan
8 shared publications- Akio Katanuma
Center for Gastroenterology, Teine Keijinkai Hospital, Sapporo, Japan
7 shared publications
Latest Publications
- 2 June 2024
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 31 (8) , 591-600
Visibility of the biliary orifice after precut papillotomy: Comparison between white light imaging and texture and color enhancement imaging
Background: Precut papillotomy is performed in cases of difficult biliary cannulation, but identification of the biliary orifice is difficult. Texture and color enhancement imaging (TXI) can enhance the structure, color, and brightness. This study compared TXI and white light imaging (WLI) in visibility of biliary orifices.Methods: We retrospectively examined 20 patients who underwent bile duct cannulation using both WLI and TXI after precut papillotomy at our center between 2021 and 2022. On WLI and TXI images displayed in random order, bile duct orifice on precut‐incision surface of each image was independently evaluated by eight evaluators. Single‐indication accuracy rate of biliary orifices, visibility score rated on a 4‐grade scale, and color difference between the biliary orifice and the surrounding tissue were examined.Results: The single‐indication accuracy rate was higher in TXI compared to WLI (50.6% vs. 35.6%, odds ratio 2.26 [95% CI: 1.32–3.89], p = .003). The time to indicate the biliary orifice was comparable between TXI and WLI (median, 9.7 s [range, 2.6–43] vs. 10.9 s [1.5–64], p = .086). Furthermore, the visibility score was higher in TXI than in WLI (median, 3 [interquartile range, 2–3] vs. 2 [2, 3], p < .001), and the color difference between the biliary orifice and surrounding tissue in TXI was more pronounced than in WLI (median, 22.9 [range, 9.39–55.2] vs. 18.0 [6.48–43.0]; p < .001).Conclusions: TXI enhanced the color difference and visibility of the biliary orifice after precut and improved single‐indication accuracy rate, suggesting that it could be useful for biliary cannulation after precut papillotomy.
- 2 June 2024
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 31 (8) , 591-600
Visibility of the biliary orifice after precut papillotomy: Comparison between white light imaging and texture and color enhancement imaging
Background: Precut papillotomy is performed in cases of difficult biliary cannulation, but identification of the biliary orifice is difficult. Texture and color enhancement imaging (TXI) can enhance the structure, color, and brightness. This study compared TXI and white light imaging (WLI) in visibility of biliary orifices.Methods: We retrospectively examined 20 patients who underwent bile duct cannulation using both WLI and TXI after precut papillotomy at our center between 2021 and 2022. On WLI and TXI images displayed in random order, bile duct orifice on precut‐incision surface of each image was independently evaluated by eight evaluators. Single‐indication accuracy rate of biliary orifices, visibility score rated on a 4‐grade scale, and color difference between the biliary orifice and the surrounding tissue were examined.Results: The single‐indication accuracy rate was higher in TXI compared to WLI (50.6% vs. 35.6%, odds ratio 2.26 [95% CI: 1.32–3.89], p = .003). The time to indicate the biliary orifice was comparable between TXI and WLI (median, 9.7 s [range, 2.6–43] vs. 10.9 s [1.5–64], p = .086). Furthermore, the visibility score was higher in TXI than in WLI (median, 3 [interquartile range, 2–3] vs. 2 [2, 3], p < .001), and the color difference between the biliary orifice and surrounding tissue in TXI was more pronounced than in WLI (median, 22.9 [range, 9.39–55.2] vs. 18.0 [6.48–43.0]; p < .001).Conclusions: TXI enhanced the color difference and visibility of the biliary orifice after precut and improved single‐indication accuracy rate, suggesting that it could be useful for biliary cannulation after precut papillotomy.
- Open Access
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E1016-E1017
Successful endoscopic ultrasound-guided drainage using contrast-enhanced harmonic imaging
Contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) has been reported to be useful in the diagnosis of pancreatobiliary disease. CH-EUS facilitates the differentiation of the cystic component from the parenchymal component by assessing the presence of blood flow [1] [2]. Herein, we report a case of successful EUS-guided transluminal drainage (EUS-TD) for infected pancreatic fluid collection using CH-EUS. A 56-year-old man who had undergone distal pancreatectomy for pancreatic cancer two months ago was admitted to our hospital because of fever. Contrast-enhanced computed tomography revealed a postoperative pancreatic fistula (POPF) with fluid collection around the pancreas ([Fig. 1]) and EUS-TD was attempted. Initially, we scanned the lesion with fundamental B-mode ultrasound, but the POPF was not well-recognized ([Fig. 2] a). Consequently, CH-EUS was performed to identify the spread of the POPF cavity and its margins. The initially targeted location was recognized as only minimal avascular areas ([Fig. 2] b). However, as a large avascular area was identified at another location ([Fig. 3]), EUS-TD was successfully performed ([Fig. 4], [Fig. 5]; [Video 1]). After the procedure, the patient’s symptoms resolved, and he was discharged five days later without any adverse events. A POPF is usually well recognized in fundamental B-mode because of its predominantly liquid component. However, when it is composed mostly of solid components, such as necrosis, and has only a small liquid component, the boundary with the surrounding tissue is difficult to identify. In the present case, using CH-EUS the POPF cavity exhibited no enhancement owing to the absence of vascularity, whereas the surrounding tissue was enhanced. The application of CH-EUS may be useful in demarcating the boundary between the POPF cavity and its surrounding tissue in EUS-TD. Endoscopy_UCTN_Code_TTT_1AS_2AJ Article published online: 22 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E1016-E1017
Open AccessSuccessful endoscopic ultrasound-guided drainage using contrast-enhanced harmonic imaging
Contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) has been reported to be useful in the diagnosis of pancreatobiliary disease. CH-EUS facilitates the differentiation of the cystic component from the parenchymal component by assessing the presence of blood flow [1] [2]. Herein, we report a case of successful EUS-guided transluminal drainage (EUS-TD) for infected pancreatic fluid collection using CH-EUS. A 56-year-old man who had undergone distal pancreatectomy for pancreatic cancer two months ago was admitted to our hospital because of fever. Contrast-enhanced computed tomography revealed a postoperative pancreatic fistula (POPF) with fluid collection around the pancreas ([Fig. 1]) and EUS-TD was attempted. Initially, we scanned the lesion with fundamental B-mode ultrasound, but the POPF was not well-recognized ([Fig. 2] a). Consequently, CH-EUS was performed to identify the spread of the POPF cavity and its margins. The initially targeted location was recognized as only minimal avascular areas ([Fig. 2] b). However, as a large avascular area was identified at another location ([Fig. 3]), EUS-TD was successfully performed ([Fig. 4], [Fig. 5]; [Video 1]). After the procedure, the patient’s symptoms resolved, and he was discharged five days later without any adverse events. A POPF is usually well recognized in fundamental B-mode because of its predominantly liquid component. However, when it is composed mostly of solid components, such as necrosis, and has only a small liquid component, the boundary with the surrounding tissue is difficult to identify. In the present case, using CH-EUS the POPF cavity exhibited no enhancement owing to the absence of vascularity, whereas the surrounding tissue was enhanced. The application of CH-EUS may be useful in demarcating the boundary between the POPF cavity and its surrounding tissue in EUS-TD. Endoscopy_UCTN_Code_TTT_1AS_2AJ Article published online: 22 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E1018-E1019
Biliary cannulation of a peridiverticular papilla using multiloop traction in a patient with Roux-en-Y anatomy
Post-surgical altered anatomy is a hurdle for biliary cannulation during endoscopic retrograde cholangiopancreatography (ERCP) [1]. The innovative multiloop traction method has been described for difficult biliary cannulation because of periampullary diverticula [2] [3]. We report successful biliary cannulation using the multiloop method with double-balloon ERCP for a peridiverticular papilla. A 76-year-old man with a history of distal gastrectomy with Roux-en-Y reconstruction was admitted to our hospital with epigastric pain and was diagnosed with a common bile duct stone. Double-balloon ERCP was attempted, but the bile duct opening was not identified because of the peridiverticular papilla. Therefore, the multiloop technique was applied ([Fig. 1], [Video 1]) to pull the papilla out of the diverticulum and reveal the bile duct opening. A SureClip (Micro-Tech, Nanjing, China) attached to a multiloop thread was used to grasp the duodenal mucosa near the papilla ([Fig. 2]). Additional clips were hooked to the free loop and attached to the oral side of the intestinal wall. This provided a traction force that pulled the papilla out of the diverticulum. The bile duct opening was visualized and biliary cannulation was achieved ([Fig. 3], [Fig. 4]). Finally, endoscopic large-balloon dilation was performed, and the bile duct stone was successfully removed. The patient was discharged 4 days after the procedure without complications. Biliary cannulation in a surgically altered anatomy is often challenging because of the instability of the endoscope and the limitations of the devices used in balloon-assisted endoscopy. Some case reports have described that the multiloop method provides a sufficient view of the papilla for biliary cannulation in normal anatomy. However, its use in patients with surgically altered anatomy has not been reported to date. This case suggests that the multiloop method is also useful for biliary cannulation in cases of periampullary diverticula with post-surgical altered anatomy. Endoscopy_UCTN_Code_TTT_1AR_2AB Article published online: 22 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E1018-E1019
Open AccessBiliary cannulation of a peridiverticular papilla using multiloop traction in a patient with Roux-en-Y anatomy
Post-surgical altered anatomy is a hurdle for biliary cannulation during endoscopic retrograde cholangiopancreatography (ERCP) [1]. The innovative multiloop traction method has been described for difficult biliary cannulation because of periampullary diverticula [2] [3]. We report successful biliary cannulation using the multiloop method with double-balloon ERCP for a peridiverticular papilla. A 76-year-old man with a history of distal gastrectomy with Roux-en-Y reconstruction was admitted to our hospital with epigastric pain and was diagnosed with a common bile duct stone. Double-balloon ERCP was attempted, but the bile duct opening was not identified because of the peridiverticular papilla. Therefore, the multiloop technique was applied ([Fig. 1], [Video 1]) to pull the papilla out of the diverticulum and reveal the bile duct opening. A SureClip (Micro-Tech, Nanjing, China) attached to a multiloop thread was used to grasp the duodenal mucosa near the papilla ([Fig. 2]). Additional clips were hooked to the free loop and attached to the oral side of the intestinal wall. This provided a traction force that pulled the papilla out of the diverticulum. The bile duct opening was visualized and biliary cannulation was achieved ([Fig. 3], [Fig. 4]). Finally, endoscopic large-balloon dilation was performed, and the bile duct stone was successfully removed. The patient was discharged 4 days after the procedure without complications. Biliary cannulation in a surgically altered anatomy is often challenging because of the instability of the endoscope and the limitations of the devices used in balloon-assisted endoscopy. Some case reports have described that the multiloop method provides a sufficient view of the papilla for biliary cannulation in normal anatomy. However, its use in patients with surgically altered anatomy has not been reported to date. This case suggests that the multiloop method is also useful for biliary cannulation in cases of periampullary diverticula with post-surgical altered anatomy. Endoscopy_UCTN_Code_TTT_1AR_2AB Article published online: 22 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 30 September 2023
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (11) , E75-E77
Tip‐in endoscopic papillectomy for ampullary adenoma near diverticulum to minimize complications
- 30 September 2023
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (11) , E75-E77
Tip‐in endoscopic papillectomy for ampullary adenoma near diverticulum to minimize complications
- 12 September 2023
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (10) , 1180-1187
Risk factors for early and late cholecystitis after covered metal stent placement for distal biliary obstruction
Background: Cholecystitis is a major adverse event after self‐expandable metallic stent placement for distal biliary obstruction (DBO). Covered self‐expandable metallic stent (CSEMS) is being increasingly used, but few studies have investigated risk factors for cholecystitis limited to CSEMS. The present study aimed to identify risk factors for cholecystitis after CSEMS.Methods: Patients who underwent initial CSEMS placement for DBO between November 2014 and September 2021 were enrolled and followed‐up until death, recurrent biliary obstruction, cholecystitis, or until March 2022. Cholecystitis within 30 days of CSEMS was defined as early cholecystitis and after 30 days as late cholecystitis.Results: Cholecystitis occurred in 51 of 339 patients (15%) after CSEMS. Forty‐one patients (80.4%) had early cholecystitis, and 10 (19.6%) had late cholecystitis. Multivariate logistic regression analysis revealed that the maximum diameter of the common bile duct (CBD) (per 1 mm increase) (odds ratio [OR]: 0.87; 95% confidence interval [CI]: 0.76–1.00; p = .044), gallbladder stones (OR: 3.63; 95% CI: 1.62–8.10; p = .002), and tumor involvement in the cystic duct (CD) (OR: 4.87; 95% CI: 2.16–11.00; p < .001) were significant independent risk factors associated with early cholecystitis. No significant risk factors were identified for late cholecystitis.Conclusions: A smaller CBD diameter, gallbladder stones, and tumor involvement in the CD were identified as risk factors for early cholecystitis development after CSEMS.
- 12 September 2023
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (10) , 1180-1187
Risk factors for early and late cholecystitis after covered metal stent placement for distal biliary obstruction
Background: Cholecystitis is a major adverse event after self‐expandable metallic stent placement for distal biliary obstruction (DBO). Covered self‐expandable metallic stent (CSEMS) is being increasingly used, but few studies have investigated risk factors for cholecystitis limited to CSEMS. The present study aimed to identify risk factors for cholecystitis after CSEMS.Methods: Patients who underwent initial CSEMS placement for DBO between November 2014 and September 2021 were enrolled and followed‐up until death, recurrent biliary obstruction, cholecystitis, or until March 2022. Cholecystitis within 30 days of CSEMS was defined as early cholecystitis and after 30 days as late cholecystitis.Results: Cholecystitis occurred in 51 of 339 patients (15%) after CSEMS. Forty‐one patients (80.4%) had early cholecystitis, and 10 (19.6%) had late cholecystitis. Multivariate logistic regression analysis revealed that the maximum diameter of the common bile duct (CBD) (per 1 mm increase) (odds ratio [OR]: 0.87; 95% confidence interval [CI]: 0.76–1.00; p = .044), gallbladder stones (OR: 3.63; 95% CI: 1.62–8.10; p = .002), and tumor involvement in the cystic duct (CD) (OR: 4.87; 95% CI: 2.16–11.00; p < .001) were significant independent risk factors associated with early cholecystitis. No significant risk factors were identified for late cholecystitis.Conclusions: A smaller CBD diameter, gallbladder stones, and tumor involvement in the CD were identified as risk factors for early cholecystitis development after CSEMS.
- 1 September 2023
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (10) , 1192-1195
The application of low echo reduction in endoscopic ultrasound‐guided tissue acquisition for pancreatic mass lesions
Toyonaga and colleagues demonstrate, with accompanying video, the use of low echo reduction, which is a novel endoscopic ultrasound function provided by a new endoscopic ultrasound processor that increases contrast without white-out. Low echo reduction might be useful in improving lesion boundaries and needle visibility during endoscopic ultrasound-guided tissue acquisition.
- 1 September 2023
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (10) , 1192-1195
The application of low echo reduction in endoscopic ultrasound‐guided tissue acquisition for pancreatic mass lesions
Toyonaga and colleagues demonstrate, with accompanying video, the use of low echo reduction, which is a novel endoscopic ultrasound function provided by a new endoscopic ultrasound processor that increases contrast without white-out. Low echo reduction might be useful in improving lesion boundaries and needle visibility during endoscopic ultrasound-guided tissue acquisition.
- 25 December 2022
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (7) , E49-E50
Successful “one‐step” endoscopic ultrasonography‐guided drainage using a fully‐covered self‐expandable metal stent for a large infected hepatic cyst
Hama et al. reported a case of successful "One-step" endoscopic ultrasonography-guided hepatic cyst drainage using a self-expandable metal stent (SEMS) for a large hepatic cyst. "One-step" placement of a fully covered SEMS without fistula dilation, as in this case, may be a useful method for the prevention of leakage of infected fluid into the abdominal cavity.
- 25 December 2022
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (7) , E49-E50
Successful “one‐step” endoscopic ultrasonography‐guided drainage using a fully‐covered self‐expandable metal stent for a large infected hepatic cyst
Hama et al. reported a case of successful "One-step" endoscopic ultrasonography-guided hepatic cyst drainage using a self-expandable metal stent (SEMS) for a large hepatic cyst. "One-step" placement of a fully covered SEMS without fistula dilation, as in this case, may be a useful method for the prevention of leakage of infected fluid into the abdominal cavity.
- 15 November 2022
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (6) , E43-E45
Gel immersion endoscopic ultrasonography for ampullary tumors
Toyonaga and colleagues present gel immersion endoscopic ultrasonography for ampullary tumors. They propose that gel immersion endoscopic ultrasonography is usefulness in evaluating of ampurally tumors because it allows clear and stable observation for an extended period with a low filling gel volume without papilla compression of the duodenal papilla.
- 15 November 2022
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 30 (6) , E43-E45
Gel immersion endoscopic ultrasonography for ampullary tumors
Toyonaga and colleagues present gel immersion endoscopic ultrasonography for ampullary tumors. They propose that gel immersion endoscopic ultrasonography is usefulness in evaluating of ampurally tumors because it allows clear and stable observation for an extended period with a low filling gel volume without papilla compression of the duodenal papilla.
- 22 October 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 35 (3) , 369-376
Efficacy of pancreatic duct stenting to prevent postendoscopic retrograde cholangiopancreatography pancreatitis after covered self‐expandable metal stent deployment
Objectives: Although covered self‐expandable metal stents (CSEMSs) are associated with the risk of postendoscopic retrograde cholangiopancreatography (ERCP) pancreatitis due to pancreatic duct (PD) orifice obstruction, they are often used for biliary drainage treatment in malignant biliary obstruction (MBO). This study aimed to investigate the efficacy of PD stenting in preventing post‐ERCP pancreatitis after CSEMS implantation.Methods: This retrospective cohort study analyzed 554 patients with transpapillary CSEMS for MBO. Patients with noninitial deployment, benign disease, CSEMS deployment above the papilla, surgically altered anatomy, uncovered self‐expandable metal stents, multiple thin self‐expandable metal stents, and unavailable procedure videos were excluded. Logistic regression analysis estimated the association between PD stenting and post‐ERCP pancreatitis incidence. We adjusted for age, sex, pancreatitis history, prophylactic rectal nonsteroidal anti‐inflammatory drug use, naïve papilla, MBO etiology, and prolonged biliary cannulation time.Results: Among 554 patients, 67 (12.1%) experienced post‐ERCP pancreatitis. Post‐ERCP pancreatitis was recorded in 13.7% of patients in the non‐PD stenting and 4.3% in the PD stenting groups. Pancreatic duct stenting was associated with lower risks of post‐ERCP pancreatitis (odds ratio [OR] 0.28; 95% confidence interval [CI] 0.099–0.79; P = 0.028). In multivariable analysis, the association between PD stenting and lower post‐ERCP pancreatitis incidence was consistent (OR 0.19; 95% CI 0.062–0.58; P = 0.0034).Conclusions: Pancreatic duct stenting could reduce the risk of post‐ERCP pancreatitis after CSEMSs.
- 22 October 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 35 (3) , 369-376
Efficacy of pancreatic duct stenting to prevent postendoscopic retrograde cholangiopancreatography pancreatitis after covered self‐expandable metal stent deployment
Objectives: Although covered self‐expandable metal stents (CSEMSs) are associated with the risk of postendoscopic retrograde cholangiopancreatography (ERCP) pancreatitis due to pancreatic duct (PD) orifice obstruction, they are often used for biliary drainage treatment in malignant biliary obstruction (MBO). This study aimed to investigate the efficacy of PD stenting in preventing post‐ERCP pancreatitis after CSEMS implantation.Methods: This retrospective cohort study analyzed 554 patients with transpapillary CSEMS for MBO. Patients with noninitial deployment, benign disease, CSEMS deployment above the papilla, surgically altered anatomy, uncovered self‐expandable metal stents, multiple thin self‐expandable metal stents, and unavailable procedure videos were excluded. Logistic regression analysis estimated the association between PD stenting and post‐ERCP pancreatitis incidence. We adjusted for age, sex, pancreatitis history, prophylactic rectal nonsteroidal anti‐inflammatory drug use, naïve papilla, MBO etiology, and prolonged biliary cannulation time.Results: Among 554 patients, 67 (12.1%) experienced post‐ERCP pancreatitis. Post‐ERCP pancreatitis was recorded in 13.7% of patients in the non‐PD stenting and 4.3% in the PD stenting groups. Pancreatic duct stenting was associated with lower risks of post‐ERCP pancreatitis (odds ratio [OR] 0.28; 95% confidence interval [CI] 0.099–0.79; P = 0.028). In multivariable analysis, the association between PD stenting and lower post‐ERCP pancreatitis incidence was consistent (OR 0.19; 95% CI 0.062–0.58; P = 0.0034).Conclusions: Pancreatic duct stenting could reduce the risk of post‐ERCP pancreatitis after CSEMSs.
- Open Access
- 1 September 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 02) , E1074-E1075
Traction method using slim biopsy forceps for prevention of stent migration during multiple biliary stent placement
Stent migration is a possible complication encountered during placement of multiple biliary stents [1]. The SpyBite Max Biopsy Forceps (Boston Scientific Endoscopy, Natick, Massachusetts, United States), which are very slim biopsy forceps, have been developed for biopsy during peroral cholangioscopy. The forceps are introduced simultaneously from the same working channel of the duodenoscope during placement of the 7-Fr or 8.5-Fr biliary stent. Herein, we present a novel traction technique using SpyBite to prevent stent migration during placement of multiple stents. Case 1: In an 85-year-old man with obstructive jaundice owing to lymph metastasis of lung cancer, computed tomography revealed a biliary stricture extending beyond the bifurcation of the common hepatic duct, requiring multiple biliary drainages. After stent placement into B6, we attempted to add a plastic stent to B8; however, the first stent almost migrated into the bile duct. By grasping the flap of the first stent using the SpyBite, we successfully placed the second stent without migration of the first ([Fig. 1], [Fig. 2]; [Video 1]). Video 1 Successful prevention of stent migration during placement of multiple stents in two cases. Case 2: An 84-year-old woman was admitted to the hospital for obstructive jaundice owing to a serous cystic neoplasm and underwent endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS). One month thereafter, reintervention was required because of obstructive cholangitis. We attempted to place three plastic stents. During the placement of the third stent, the first stent almost migrated into the abdominal cavity. The third stent was successfully placed when the flap of the first stent was grasped using SpyBite ([Fig. 3], [Fig. 4], [Fig. 5]; [Video 1]). Despite reports of troubleshooting for retrieval of a migrated stent [2] [3] [4], retrieval of the stent can be challenging once migration occurs; therefore, prevention is important. Endoscopists should be aware of the characteristics of the scopes and devices used routinely, such as the diameter of the working channel and devices, which may be helpful in troubleshooting. Endoscopy_UCTN_Code_TTT_1AR_2AZ Article published online: 01 September 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 1 September 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 02) , E1074-E1075
Open AccessTraction method using slim biopsy forceps for prevention of stent migration during multiple biliary stent placement
Stent migration is a possible complication encountered during placement of multiple biliary stents [1]. The SpyBite Max Biopsy Forceps (Boston Scientific Endoscopy, Natick, Massachusetts, United States), which are very slim biopsy forceps, have been developed for biopsy during peroral cholangioscopy. The forceps are introduced simultaneously from the same working channel of the duodenoscope during placement of the 7-Fr or 8.5-Fr biliary stent. Herein, we present a novel traction technique using SpyBite to prevent stent migration during placement of multiple stents. Case 1: In an 85-year-old man with obstructive jaundice owing to lymph metastasis of lung cancer, computed tomography revealed a biliary stricture extending beyond the bifurcation of the common hepatic duct, requiring multiple biliary drainages. After stent placement into B6, we attempted to add a plastic stent to B8; however, the first stent almost migrated into the bile duct. By grasping the flap of the first stent using the SpyBite, we successfully placed the second stent without migration of the first ([Fig. 1], [Fig. 2]; [Video 1]). Video 1 Successful prevention of stent migration during placement of multiple stents in two cases. Case 2: An 84-year-old woman was admitted to the hospital for obstructive jaundice owing to a serous cystic neoplasm and underwent endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS). One month thereafter, reintervention was required because of obstructive cholangitis. We attempted to place three plastic stents. During the placement of the third stent, the first stent almost migrated into the abdominal cavity. The third stent was successfully placed when the flap of the first stent was grasped using SpyBite ([Fig. 3], [Fig. 4], [Fig. 5]; [Video 1]). Despite reports of troubleshooting for retrieval of a migrated stent [2] [3] [4], retrieval of the stent can be challenging once migration occurs; therefore, prevention is important. Endoscopists should be aware of the characteristics of the scopes and devices used routinely, such as the diameter of the working channel and devices, which may be helpful in troubleshooting. Endoscopy_UCTN_Code_TTT_1AR_2AZ Article published online: 01 September 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany