Hee-Moon Kyung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hee-Moon Kyung has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Seong-Min Bae
Private practice, Daegu, Korea
5 shared publications- Hyo-Sang Park
Department of Orthodontics, School of Dentistry, Kyungpook National University, Daegu, Korea
4 shared publications Jae-Hyun Sung
4 shared publicationsWonjae Yu
Department of Orthodontics, School of Dentistry, Kyungpook National University, Daegu, Korea
4 shared publicationsIl-Bong Kim
2 shared publicationsJoachim Ngiam
Department of Orthodontics, School of Dentistry, Kyungpook National University, Daegu, Korea
2 shared publications
Latest Publications
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 26 (1) , e2119155
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 26 (1) , e2119155
Open AccessStability of immediately loaded 3 mm long miniscrew implants: a feasibility study
Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.
- Open Access
- 1 January 2020
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 50 (1) , 26-32
Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics
Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.
- 1 January 2020
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 50 (1) , 26-32
Open AccessComparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics
Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.
- 1 January 2018
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 153 (1) , 108-117
Long-term changes of the anterior palatal alveolar bone after treatment with bialveolar protrusion, evaluated with computed tomography
- 1 January 2018
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 153 (1) , 108-117
Long-term changes of the anterior palatal alveolar bone after treatment with bialveolar protrusion, evaluated with computed tomography
- 1 March 2017
- Vol. 51 (3) , 173-178
Treatment of an Impacted and Inverted Upper Premolar.
- Open Access
- 1 January 2017
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 47 (3) , 158-166
Effects of bracket slot size duringen-masseretraction of the six maxillary anterior teeth using an induction-heating typodont simulation system
Kim JY, et al. Korean J Orthod. 2017 May;47(3):158-166. https://doi.org/10.4041/kjod.2017.47.3.158
- 1 January 2017
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 47 (3) , 158-166
Open AccessEffects of bracket slot size duringen-masseretraction of the six maxillary anterior teeth using an induction-heating typodont simulation system
Kim JY, et al. Korean J Orthod. 2017 May;47(3):158-166. https://doi.org/10.4041/kjod.2017.47.3.158
- Open Access
- 1 January 2017
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 47 (1) , 3-10
Incorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties
Microbial aggregation around dental implants can lead to loss/loosening of the implants. This study was aimed at surface treating titanium microimplants with silver nanoparticles (AgNPs) to achieve antibacterial properties. AgNP-modified titanium microimplants (Ti-nAg) were prepared using two methods. The first method involved coating the microimplants with regular AgNPs (Ti-AgNP) and the second involved coating them with a AgNP-coated biopolymer (Ti-BP-AgNP). The topologies, microstructures, and chemical compositions of the surfaces of the Ti-nAg were characterized by scanning electron microscopy (SEM) equipped with energy-dispersive spectrometer (EDS) and X-ray photoelectron spectroscopy (XPS). Disk diffusion tests using Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans were performed to test the antibacterial activity of the Ti-nAg microimplants. SEM revealed that only a meager amount of AgNPs was sparsely deposited on the Ti-AgNP surface with the first method, while a layer of AgNP-coated biopolymer extended along the Ti-BP-AgNP surface in the second method. The diameters of the coated nanoparticles were in the range of 10 to 30 nm. EDS revealed 1.05 atomic % of Ag on the surface of the Ti-AgNP and an astounding 21.2 atomic % on the surface of the Ti-BP-AgNP. XPS confirmed the metallic state of silver on the Ti-BP-AgNP surface. After 24 hours of incubation, clear zones of inhibition were seen around the Ti-BP-AgNP microimplants in all three test bacterial culture plates, whereas no antibacterial effect was observed with the Ti-AgNP microimplants. Titanium microimplants modified with Ti-BP-AgNP exhibit excellent antibacterial properties, making them a promising implantable biomaterial.
- 1 January 2017
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 47 (1) , 3-10
Open AccessIncorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties
Microbial aggregation around dental implants can lead to loss/loosening of the implants. This study was aimed at surface treating titanium microimplants with silver nanoparticles (AgNPs) to achieve antibacterial properties. AgNP-modified titanium microimplants (Ti-nAg) were prepared using two methods. The first method involved coating the microimplants with regular AgNPs (Ti-AgNP) and the second involved coating them with a AgNP-coated biopolymer (Ti-BP-AgNP). The topologies, microstructures, and chemical compositions of the surfaces of the Ti-nAg were characterized by scanning electron microscopy (SEM) equipped with energy-dispersive spectrometer (EDS) and X-ray photoelectron spectroscopy (XPS). Disk diffusion tests using Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans were performed to test the antibacterial activity of the Ti-nAg microimplants. SEM revealed that only a meager amount of AgNPs was sparsely deposited on the Ti-AgNP surface with the first method, while a layer of AgNP-coated biopolymer extended along the Ti-BP-AgNP surface in the second method. The diameters of the coated nanoparticles were in the range of 10 to 30 nm. EDS revealed 1.05 atomic % of Ag on the surface of the Ti-AgNP and an astounding 21.2 atomic % on the surface of the Ti-BP-AgNP. XPS confirmed the metallic state of silver on the Ti-BP-AgNP surface. After 24 hours of incubation, clear zones of inhibition were seen around the Ti-BP-AgNP microimplants in all three test bacterial culture plates, whereas no antibacterial effect was observed with the Ti-AgNP microimplants. Titanium microimplants modified with Ti-BP-AgNP exhibit excellent antibacterial properties, making them a promising implantable biomaterial.
- 1 July 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (7) , 496-504
Genetic polymorphisms in pattern recognition receptors and risk of periodontitis: Evidence based on 12,793 subjects
- 1 July 2015
- Published by Elsevier in Human Immunology
- Vol. 76 (7) , 496-504
Genetic polymorphisms in pattern recognition receptors and risk of periodontitis: Evidence based on 12,793 subjects
- Open Access
- 1 January 2013
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 43 (5) , 235-241
Debonding forces of three different customized bases of a lingual bracket system
Sung JW, et al. Korean J Orthod. 2013 Oct;43(5):235-241. http://dx.doi.org/10.4041/kjod.2013.43.5.235
- 1 January 2013
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 43 (5) , 235-241
Open AccessDebonding forces of three different customized bases of a lingual bracket system
Sung JW, et al. Korean J Orthod. 2013 Oct;43(5):235-241. http://dx.doi.org/10.4041/kjod.2013.43.5.235
- 1 November 2012
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (6) , 978-984
Microimplant-based mandibular advancement therapy for the treatment of snoring and obstructive sleep apnea: a prospective study
Objective: To investigate the efficacy of orthodontic microimplant–based mandibular advancement therapies for the treatment of snoring and obstructive sleep apnea (OSA) in adult patients. Materials and Methods: Ten adult OSA patients (seven men, three women; mean age 60.00 ± 9.25 years) were each treated with two mandibular orthodontic microimplants attached to a customized reverse face mask for mandibular advancement. Pretreatment and posttreatment outcome measures of microimplant mobility, apnea-hypopnea index, snoring, respiratory movement, and Epworth sleepiness scores were evaluated after 6 months. Results: Highly significant reductions in the apnea-hypopnea index, snoring, and sleep variables were observed. Sixteen of the 20 (80%) microimplants were stable and showed no mobility, and four (20%) demonstrated grade 1 or 2 mobility and required removal and reinsertion of a new microimplant. Conclusions: Favorable reductions in sleep variables highlight the potential of microimplant-based mandibular advancement therapy as an alternative treatment modality for OSA patients who cannot tolerate continuous positive airway pressure and oral appliance therapy.
- 1 November 2012
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (6) , 978-984
Microimplant-based mandibular advancement therapy for the treatment of snoring and obstructive sleep apnea: a prospective study
Objective: To investigate the efficacy of orthodontic microimplant–based mandibular advancement therapies for the treatment of snoring and obstructive sleep apnea (OSA) in adult patients. Materials and Methods: Ten adult OSA patients (seven men, three women; mean age 60.00 ± 9.25 years) were each treated with two mandibular orthodontic microimplants attached to a customized reverse face mask for mandibular advancement. Pretreatment and posttreatment outcome measures of microimplant mobility, apnea-hypopnea index, snoring, respiratory movement, and Epworth sleepiness scores were evaluated after 6 months. Results: Highly significant reductions in the apnea-hypopnea index, snoring, and sleep variables were observed. Sixteen of the 20 (80%) microimplants were stable and showed no mobility, and four (20%) demonstrated grade 1 or 2 mobility and required removal and reinsertion of a new microimplant. Conclusions: Favorable reductions in sleep variables highlight the potential of microimplant-based mandibular advancement therapy as an alternative treatment modality for OSA patients who cannot tolerate continuous positive airway pressure and oral appliance therapy.
- Open Access
- 1 January 2012
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 42 (1) , 4-10
Effect of surface anodization on stability of orthodontic microimplant
Karmarker S, et al. Korean J Orthod. 2012 Feb;42(1):4-10. http://dx.doi.org/10.4041/kjod.2012.42.1.4
- 1 January 2012
- Published by Korean Association of Orthodontists in The Korean Journal of Orthodontics
- Vol. 42 (1) , 4-10
Open AccessEffect of surface anodization on stability of orthodontic microimplant
Karmarker S, et al. Korean J Orthod. 2012 Feb;42(1):4-10. http://dx.doi.org/10.4041/kjod.2012.42.1.4