Alexander Gerbershagen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander Gerbershagen has a total of 292 co-authors. Here are the top co-authors by number of shared publications:
- Manjit Dosanjh
University of Oxford
3 shared publications - Andrea Latina
European Organization for Nuclear Research
2 shared publications - C. Robertson
Oxford University, OX1 4BH Oxford, U.K.
2 shared publications - Claudia Ahdida
19 European Organization for Nuclear Research (CERN), Geneva, Switzerland
2 shared publications J. Bernhard
2 shared publications- Pablo Fernandez Martinez
Centro Nacional de Microelectrónica
2 shared publications
Latest Publications
- Open Access
- 20 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
In silico feasibility and robustness evaluation of a single-spot proton Bragg peak FLASH platform for small-animal irradiation using a generalized 3D-printed bolus
Objective FLASH radiotherapy has shown potential to reduce normal tissue toxicity while maintaining tumour control, motivating the development of clinical delivery strategies. However, most preclinical proton FLASH studies rely on transmission beams or spread out Bragg peaks, which do not reflect conformal clinical dose distributions. This work aims to develop and evaluate an irradiation setup for ultra-high dose-rate Bragg peak proton delivery to orthotopic mammary tumours in mice, employable in image-guided research rooms powered by clinical cyclotrons. Approach We built a simulation framework (Python+TOPAS) to assess a single spot, ablative configuration comprising a copper degrader, collimator, and generalised (3D-printed) bolus. Performance was investigated on a Phantom Mice Cohort (N=6) using personalised boluses and a Real Mice Cohort (N=10; µCT/PET) using a cohort-derived generalised bolus. Planning goals were D99%,GTV=19.0Gy and HIGTV≤1.30. Physical dose-rate feasibility was evaluated against a nominal 40Gy/s DRmin,skin threshold under an assumed 500nA beam current cap; this metric does not establish a biological FLASH effect. Robustness evaluation included 0.35 and 0.5mm setup errors and ±3% range uncertainties. Main results Simulated plans met target and heterogeneity goals across cohorts, with the 40Gy/s DRmin,skin criterion met under the assumed beam current conditions (Dmean,skin≈18.5–19.3Gy). The modelled dose-rate criterion was met below the 500nA beam current limit in both cohorts. Under the evaluated 0.35mm setup and ±3% range uncertainties, reduction in D99%,GTV remained within 3% for 9/10 real mouse cases. The generalised bolus achieved the simulated dosimetric performance across ten anatomically distinct mice; applicability to independent cohorts remains unestablished. Significance This in silico evaluation supports the simulated dosimetric and physical dose-rate feasibility of conformal Bragg peak proton delivery in small animals using a generalised bolus. The presented framework enables further development in image-guided proton research facilities, forming a strong basis for experimental validation and commissioning toward in situ small animal studies.
- 20 November 2026
- Published by IOP Publishing in Physics in Medicine & Biology
Open AccessIn silico feasibility and robustness evaluation of a single-spot proton Bragg peak FLASH platform for small-animal irradiation using a generalized 3D-printed bolus
Objective FLASH radiotherapy has shown potential to reduce normal tissue toxicity while maintaining tumour control, motivating the development of clinical delivery strategies. However, most preclinical proton FLASH studies rely on transmission beams or spread out Bragg peaks, which do not reflect conformal clinical dose distributions. This work aims to develop and evaluate an irradiation setup for ultra-high dose-rate Bragg peak proton delivery to orthotopic mammary tumours in mice, employable in image-guided research rooms powered by clinical cyclotrons. Approach We built a simulation framework (Python+TOPAS) to assess a single spot, ablative configuration comprising a copper degrader, collimator, and generalised (3D-printed) bolus. Performance was investigated on a Phantom Mice Cohort (N=6) using personalised boluses and a Real Mice Cohort (N=10; µCT/PET) using a cohort-derived generalised bolus. Planning goals were D99%,GTV=19.0Gy and HIGTV≤1.30. Physical dose-rate feasibility was evaluated against a nominal 40Gy/s DRmin,skin threshold under an assumed 500nA beam current cap; this metric does not establish a biological FLASH effect. Robustness evaluation included 0.35 and 0.5mm setup errors and ±3% range uncertainties. Main results Simulated plans met target and heterogeneity goals across cohorts, with the 40Gy/s DRmin,skin criterion met under the assumed beam current conditions (Dmean,skin≈18.5–19.3Gy). The modelled dose-rate criterion was met below the 500nA beam current limit in both cohorts. Under the evaluated 0.35mm setup and ±3% range uncertainties, reduction in D99%,GTV remained within 3% for 9/10 real mouse cases. The generalised bolus achieved the simulated dosimetric performance across ten anatomically distinct mice; applicability to independent cohorts remains unestablished. Significance This in silico evaluation supports the simulated dosimetric and physical dose-rate feasibility of conformal Bragg peak proton delivery in small animals using a generalised bolus. The presented framework enables further development in image-guided proton research facilities, forming a strong basis for experimental validation and commissioning toward in situ small animal studies.
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 4082-4095
Demonstration of Hollow Core Optical Fiber-Based Radiation Sensing Technique With a 200 MeV Bunched Electron Beam
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 4082-4095
Open AccessDemonstration of Hollow Core Optical Fiber-Based Radiation Sensing Technique With a 200 MeV Bunched Electron Beam
- 23 June 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105031
Integration of microdosimetry into treatment planning systems using look-up tables (LUT): A proof-of-concept
- 23 June 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105031
Integration of microdosimetry into treatment planning systems using look-up tables (LUT): A proof-of-concept
- Top Cited PapersOpen Access
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05067
SND@LHC: the scattering and neutrino detector at the LHC
SND@LHC is a compact and stand-alone experiment designed to perform measurements with neutrinos produced at the LHC in the pseudo-rapidity region of 7.2 < η < 8.4. The experiment is located 480 m downstream of the ATLAS interaction point, in the TI18 tunnel. The detector is composed of a hybrid system based on an 830 kg target made of tungsten plates, interleaved with emulsion and electronic trackers, also acting as an electromagnetic calorimeter, and followed by a hadronic calorimeter and a muon identification system. The detector is able to distinguish interactions of all three neutrino flavours, which allows probing the physics of heavy flavour production at the LHC in the very forward region. This region is of particular interest for future circular colliders and for very high energy astrophysical neutrino experiments. The detector is also able to search for the scattering of Feebly Interacting Particles. In its first phase, the detector is ready to operate throughout LHC Run 3 and collect a total of 250 fb-1.
- 1 May 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (05) , P05067
Top Cited PapersOpen AccessSND@LHC: the scattering and neutrino detector at the LHC
SND@LHC is a compact and stand-alone experiment designed to perform measurements with neutrinos produced at the LHC in the pseudo-rapidity region of 7.2 < η < 8.4. The experiment is located 480 m downstream of the ATLAS interaction point, in the TI18 tunnel. The detector is composed of a hybrid system based on an 830 kg target made of tungsten plates, interleaved with emulsion and electronic trackers, also acting as an electromagnetic calorimeter, and followed by a hadronic calorimeter and a muon identification system. The detector is able to distinguish interactions of all three neutrino flavours, which allows probing the physics of heavy flavour production at the LHC in the very forward region. This region is of particular interest for future circular colliders and for very high energy astrophysical neutrino experiments. The detector is also able to search for the scattering of Feebly Interacting Particles. In its first phase, the detector is ready to operate throughout LHC Run 3 and collect a total of 250 fb-1.
- Open Access
- 21 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Magnetic Design of a Compact GaToroid for Very High Energy Electron and Pre-Clinical Hadron Beams
GaToroid is a novel configuration of a beam delivery system for charged particles therapy based on a steady-state, axis-symmetric field configuration. The basic idea is to use fixed toroidal magnets, producing an axis-symmetric (or periodical axis-symmetric) field configuration that can bend beams from several directions onto the patient location. In principle, neither magnets nor patient need to be moved. In addition, the field of the magnets of this toroidal gantry is static. Such system is perfectly adapted to FLASH therapy, a novel method of beam dose delivery that has shown benefits for electrons and potential for hadrons. In this paper we describe the magnetic design of a “compact GaToroid”, which could be built with iron-dominated magnets, suitable for 200 MeV electron beams, as well as protons at 70 MeV. The gantry profits from the use of toroidal quadrupoles, which greatly simplify the beam transmission. An additional novelty is the use of a resonant kicker as the vector magnet. Starting from the requirements for beam transmission, we derive first the magnet main characteristics (strength, aperture, size and mass) and report the detailed magnetic field calculations in support of the design.
- 21 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Open AccessMagnetic Design of a Compact GaToroid for Very High Energy Electron and Pre-Clinical Hadron Beams
GaToroid is a novel configuration of a beam delivery system for charged particles therapy based on a steady-state, axis-symmetric field configuration. The basic idea is to use fixed toroidal magnets, producing an axis-symmetric (or periodical axis-symmetric) field configuration that can bend beams from several directions onto the patient location. In principle, neither magnets nor patient need to be moved. In addition, the field of the magnets of this toroidal gantry is static. Such system is perfectly adapted to FLASH therapy, a novel method of beam dose delivery that has shown benefits for electrons and potential for hadrons. In this paper we describe the magnetic design of a “compact GaToroid”, which could be built with iron-dominated magnets, suitable for 200 MeV electron beams, as well as protons at 70 MeV. The gantry profits from the use of toroidal quadrupoles, which greatly simplify the beam transmission. An additional novelty is the use of a resonant kicker as the vector magnet. Starting from the requirements for beam transmission, we derive first the magnet main characteristics (strength, aperture, size and mass) and report the detailed magnetic field calculations in support of the design.
- Open Access
- 1 January 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 987
On-line beam monitoring and dose profile measurements of a Pb beam of 150 GeV/n with a liquid-filled ionization chamber array- 1 January 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 987
Open AccessOn-line beam monitoring and dose profile measurements of a Pb beam of 150 GeV/n with a liquid-filled ionization chamber array