Ning Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ning Ma has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Lihong Duan
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, People’s Republic of China
6 shared publications - Bozheng Xing
Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China
4 shared publications Bangcheng Han
Hefei National Laboratory
3 shared publicationsCe Yang
Beijing Univ. of Technology (China)
3 shared publicationsDanyue Ma
3 shared publicationsGang Liu
School of Instrumentation and Optoelectronic Engineering, Beihang Universityhttps://ror.org/00wk2mp56, Beijing 100191, China
3 shared publications
Latest Publications
- 9 June 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (12) , 3958-3961
Stabilization of a whispering gallery mode self-injection locked laser based on phase difference control
We investigate the application of feedback control of phase difference between the whispering gallery mode microresonator and the laser cavity, for the stabilization of self-injection locking. By analyzing the relationship between phase difference and microresonator transmitted light intensity, as well as the characteristics of selected phase shift devices and controller, the phase difference is successfully maintained at the set point. Through this phase difference control mechanism, the semiconductor laser with a high-quality microresonator coupled and connected by optical fibers exhibits a stable self-injection locking. Key performance metrics include a narrow linewidth of around 200 Hz and a minimum normalized output wavelength Allan deviation of 1×10−10. This approach presents a promising and reliable solution for the self-injection locked laser stabilization.
- 9 June 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (12) , 3958-3961
Stabilization of a whispering gallery mode self-injection locked laser based on phase difference control
We investigate the application of feedback control of phase difference between the whispering gallery mode microresonator and the laser cavity, for the stabilization of self-injection locking. By analyzing the relationship between phase difference and microresonator transmitted light intensity, as well as the characteristics of selected phase shift devices and controller, the phase difference is successfully maintained at the set point. Through this phase difference control mechanism, the semiconductor laser with a high-quality microresonator coupled and connected by optical fibers exhibits a stable self-injection locking. Key performance metrics include a narrow linewidth of around 200 Hz and a minimum normalized output wavelength Allan deviation of 1×10−10. This approach presents a promising and reliable solution for the self-injection locked laser stabilization.
- 7 May 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (5) , 055207
Stable whispering gallery mode microresonator self-injection locking laser for atomic comagnetometer based on thermal dynamics
The whispering-gallery mode microresonator self-injection locking lasers for atomic comagnetometers have excellent characteristics, and their stability needs to be improved. In this study, through the analysis and simulations of optical injection rate equations with thermal dynamics of the microresonator, a frequency adjustment strategy is presented that ensures the stability of the self-injection locking laser output wavelength over time. The normalized Allan deviation of the output wavelength is 1.7 × 10−10, and both the 20.6 Hz / Hz laser frequency noise and the 375 Hz linewidth are maintained within one hour. These results demonstrate exceptional self-injection locking stability with the 109 quality factor microresonator.
- 7 May 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (5) , 055207
Stable whispering gallery mode microresonator self-injection locking laser for atomic comagnetometer based on thermal dynamics
The whispering-gallery mode microresonator self-injection locking lasers for atomic comagnetometers have excellent characteristics, and their stability needs to be improved. In this study, through the analysis and simulations of optical injection rate equations with thermal dynamics of the microresonator, a frequency adjustment strategy is presented that ensures the stability of the self-injection locking laser output wavelength over time. The normalized Allan deviation of the output wavelength is 1.7 × 10−10, and both the 20.6 Hz / Hz laser frequency noise and the 375 Hz linewidth are maintained within one hour. These results demonstrate exceptional self-injection locking stability with the 109 quality factor microresonator.
- Top Cited PapersOpen Access
- 17 January 2025
- Published by Elsevier in Measurement
- Vol. 246
Two-channel whispering gallery mode self-injection locking lasers for hybrid optically pumped atomic comagnetometers
- 17 January 2025
- Published by Elsevier in Measurement
- Vol. 246
Top Cited PapersOpen AccessTwo-channel whispering gallery mode self-injection locking lasers for hybrid optically pumped atomic comagnetometers
- 24 October 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 017003
Frequency noise suppression of the high-power pumping laser in the SERF atomic magnetometer
A high-sensitivity spin exchange relaxation free (SERF) atomic magnetometer based on a noise-suppressed master oscillator power amplifier (MOPA) system is demonstrated. The spectrum and frequency noise of the laser are measured and it is proved that the frequency noise in the MOPA system is affected by the amplified spontaneous emission (ASE) stimulated from the power amplifier. The frequency noise of the MOPA system is decreased by filtering out the ASE background in the spectrum through a bandpass filter. The sensitivity of the SERF atomic magnetometer is improved by using the frequency noise-suppressed MOPA system as a pumping laser. This method can also be applied to other precision measurement fields based on MOPA systems that have high requirements for frequency noise of lasers.
- 24 October 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 017003
Frequency noise suppression of the high-power pumping laser in the SERF atomic magnetometer
A high-sensitivity spin exchange relaxation free (SERF) atomic magnetometer based on a noise-suppressed master oscillator power amplifier (MOPA) system is demonstrated. The spectrum and frequency noise of the laser are measured and it is proved that the frequency noise in the MOPA system is affected by the amplified spontaneous emission (ASE) stimulated from the power amplifier. The frequency noise of the MOPA system is decreased by filtering out the ASE background in the spectrum through a bandpass filter. The sensitivity of the SERF atomic magnetometer is improved by using the frequency noise-suppressed MOPA system as a pumping laser. This method can also be applied to other precision measurement fields based on MOPA systems that have high requirements for frequency noise of lasers.
- 3 September 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (19) , 33378-33390
Enhancing the sensitivity of spin-exchange relaxation-free magnetometers using phase-modulated pump light with external Gaussian noise
An optical pumping scheme is proposed for reducing the gradient of electron spin polarization and suppressing light source noise in a spin-exchange relaxation-free magnetometer. This is achieved by modulating only the phase of a narrow-linewidth pump light field with external Gaussian noise. Compared to the absence of phase modulation, the uniformity of electron spin polarization was improved by over 40%, and the light-frequency noise suppression ratio of the magnetometer was enhanced by 4.3 times. Additionally, the response of the magnetometer was increased by 54%, resulting in a sensitivity of 0.34 fT/Hz1/2 at 30 Hz. The applicability of this scheme can extend to other optical pumping experiments involving large atom ensembles requiring uniform electron spin polarization distribution, which is beneficial for developing ultra-high sensitivity and high stability magnetometers essential for magneto-cardiography and magneto-encephalography research applications.
- 3 September 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (19) , 33378-33390
Enhancing the sensitivity of spin-exchange relaxation-free magnetometers using phase-modulated pump light with external Gaussian noise
An optical pumping scheme is proposed for reducing the gradient of electron spin polarization and suppressing light source noise in a spin-exchange relaxation-free magnetometer. This is achieved by modulating only the phase of a narrow-linewidth pump light field with external Gaussian noise. Compared to the absence of phase modulation, the uniformity of electron spin polarization was improved by over 40%, and the light-frequency noise suppression ratio of the magnetometer was enhanced by 4.3 times. Additionally, the response of the magnetometer was increased by 54%, resulting in a sensitivity of 0.34 fT/Hz1/2 at 30 Hz. The applicability of this scheme can extend to other optical pumping experiments involving large atom ensembles requiring uniform electron spin polarization distribution, which is beneficial for developing ultra-high sensitivity and high stability magnetometers essential for magneto-cardiography and magneto-encephalography research applications.
- 25 July 2024
- Published by Wiley in Advanced Quantum Technologies
- Vol. 7 (10)
Nonlinear Effect Analysis and Sensitivity Improvement in Spin Exchange Relaxation Free Atomic Magnetometers
In this study, the influence of the nonlinear magneto–optical rotation effect on a spin‐exchange relaxation‐free (SERF) atomic magnetometer is analyzed. The nonlinear effect is described by saturation parameters obtained from the density matrix model considering the Rabi oscillation of the probe light. For better sensitivity, the nonlinear effect is suppressed, and larger output signals are achieved. Based on the nonlinear effect analysis, the relationship between the probe sensitivity and light power density is obtained, and the optimal probe light power density is measured with best probe sensitivity. The best probe sensitivity improves by ≈6 times at the optimal probe light power density compared with that in the conventional linear optical rotation detection. The proposed method can be applied to SERF magnetometers, co‐magnetometers, and atomic spin gyroscopes.
- 25 July 2024
- Published by Wiley in Advanced Quantum Technologies
- Vol. 7 (10)
Nonlinear Effect Analysis and Sensitivity Improvement in Spin Exchange Relaxation Free Atomic Magnetometers
In this study, the influence of the nonlinear magneto–optical rotation effect on a spin‐exchange relaxation‐free (SERF) atomic magnetometer is analyzed. The nonlinear effect is described by saturation parameters obtained from the density matrix model considering the Rabi oscillation of the probe light. For better sensitivity, the nonlinear effect is suppressed, and larger output signals are achieved. Based on the nonlinear effect analysis, the relationship between the probe sensitivity and light power density is obtained, and the optimal probe light power density is measured with best probe sensitivity. The best probe sensitivity improves by ≈6 times at the optimal probe light power density compared with that in the conventional linear optical rotation detection. The proposed method can be applied to SERF magnetometers, co‐magnetometers, and atomic spin gyroscopes.
- Open Access
- 14 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (7)
Optically pumped magnetometers based on pseudo-random-bit-sequence phase modulation
A high-sensitivity atomic magnetometer based on broad linewidth laser pumping is demonstrated. The broad linewidth laser was obtained by broadening a narrow linewidth laser utilizing an external phase modulator driven by a pseudo-random-bit-sequence (PRBS) waveform. This ingenious optical pumping scheme can significantly enhance the signal response and suppress light shift noise, as well as can reduce the gradient of electron spin polarization and improve the stability of magnetometers. Compared with a narrow linewidth laser pumping scheme, the response of the magnetometer is increased by 56%, experimentally. The relative polarization gradient is reduced from 9.8%/cm to better than 4%/cm by setting PRBS with a bit rate of 16 GHz. This scheme can also be applied to many other fields such as noninvasive bio-magnetic imaging and atomic spin gyroscopes.
- 14 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (7)
Open AccessOptically pumped magnetometers based on pseudo-random-bit-sequence phase modulation
A high-sensitivity atomic magnetometer based on broad linewidth laser pumping is demonstrated. The broad linewidth laser was obtained by broadening a narrow linewidth laser utilizing an external phase modulator driven by a pseudo-random-bit-sequence (PRBS) waveform. This ingenious optical pumping scheme can significantly enhance the signal response and suppress light shift noise, as well as can reduce the gradient of electron spin polarization and improve the stability of magnetometers. Compared with a narrow linewidth laser pumping scheme, the response of the magnetometer is increased by 56%, experimentally. The relative polarization gradient is reduced from 9.8%/cm to better than 4%/cm by setting PRBS with a bit rate of 16 GHz. This scheme can also be applied to many other fields such as noninvasive bio-magnetic imaging and atomic spin gyroscopes.
- 2 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 45930-45941
Demonstration of a high-density alkali-metal atomic magnetometer based on the frequency-symmetrical detuning effect of two pumping lights
The existence of an approximately uniform and unsaturated electron spin polarization distribution within a high-density alkali-metal vapor is considered of great importance for significantly improving the response amplitude and sensitivity properties of an atomic magnetometer. However, when a high-density alkali-metal vapor is formed, the optical depth is much larger than the value of one, resulting in the electron spin polarization gradient. In this work, it was demonstrated from both numerical simulations and experimental points of view, that by replacing the resonant pumping light with two off-resonant pumping light sources, the signal amplitude of the magnetometer can be doubled. By using this approach, the electron spin polarization gradient can be significantly suppressed and the sensitivity can be improved by more than 10%. The proposed scheme is generally applicable to various optical pumping high-density alkali-metal vapor systems, where a uniform electron spin polarization distribution is required, such as optical pumping co-magnetometers and atomic gyroscopes.
- 2 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (25) , 45930-45941
Demonstration of a high-density alkali-metal atomic magnetometer based on the frequency-symmetrical detuning effect of two pumping lights
The existence of an approximately uniform and unsaturated electron spin polarization distribution within a high-density alkali-metal vapor is considered of great importance for significantly improving the response amplitude and sensitivity properties of an atomic magnetometer. However, when a high-density alkali-metal vapor is formed, the optical depth is much larger than the value of one, resulting in the electron spin polarization gradient. In this work, it was demonstrated from both numerical simulations and experimental points of view, that by replacing the resonant pumping light with two off-resonant pumping light sources, the signal amplitude of the magnetometer can be doubled. By using this approach, the electron spin polarization gradient can be significantly suppressed and the sensitivity can be improved by more than 10%. The proposed scheme is generally applicable to various optical pumping high-density alkali-metal vapor systems, where a uniform electron spin polarization distribution is required, such as optical pumping co-magnetometers and atomic gyroscopes.
- 23 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11410, 114100N
High-energy, high-average-power 1-kHz burst-mode picosecond laser system
We report a high-energy, high-average power burst-mode picosecond laser system, which is designed for space debris laser ranging. Pulses from a Nd : YVO4 mode-locked oscillator are first stretched by a piece of volume Bragg gratings (VBG) and then pass through an improved Michelson interferometer splitting system to obtain burst-mode pulses, which the relative amplitude and time-delay interval of each 4-pulse in bursts can be adjusted and controlled. A regenerative amplifier (RA), as a pre-amplifier, is adopted to decrease the repetition frequency of the seed beam from 80MHz to 1 KHz and raises the energy to millijoule-level. In order to reduce the performance requirement of the damage threshold of subsequent optical components and maximize the extraction of pulse energy, the Gaussian output beam of the RA is converted into a ring shaped pattern beam using an aspheric lenses reshaping system with the conversion efficiency of 93%. After a two-stage master oscillator power amplifier with 4f imaging systems, the pulse envelope energy is up to 100 mJ with the pulse duration of ~100 ps. To obtain high power green light, we compared the conversion efficiency of three crystals. When the fundamental frequency power is 80W, the second harmonic conversion efficiency of the first crystal (LBO, 6×6×10, Θ=90°, Φ=11.4°) is only about 50%, as well as the second (GTR-KTP, 7×7×7, θ=90°, Φ=23.5‡). But the conversion efficiency of the last crystal (LBO, 6×6×15, θ=90°, Φ=0°), reaches 68% and the output power of 532 nm as high as 50 W is obtained.
- 23 April 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11410, 114100N
High-energy, high-average-power 1-kHz burst-mode picosecond laser system
We report a high-energy, high-average power burst-mode picosecond laser system, which is designed for space debris laser ranging. Pulses from a Nd : YVO4 mode-locked oscillator are first stretched by a piece of volume Bragg gratings (VBG) and then pass through an improved Michelson interferometer splitting system to obtain burst-mode pulses, which the relative amplitude and time-delay interval of each 4-pulse in bursts can be adjusted and controlled. A regenerative amplifier (RA), as a pre-amplifier, is adopted to decrease the repetition frequency of the seed beam from 80MHz to 1 KHz and raises the energy to millijoule-level. In order to reduce the performance requirement of the damage threshold of subsequent optical components and maximize the extraction of pulse energy, the Gaussian output beam of the RA is converted into a ring shaped pattern beam using an aspheric lenses reshaping system with the conversion efficiency of 93%. After a two-stage master oscillator power amplifier with 4f imaging systems, the pulse envelope energy is up to 100 mJ with the pulse duration of ~100 ps. To obtain high power green light, we compared the conversion efficiency of three crystals. When the fundamental frequency power is 80W, the second harmonic conversion efficiency of the first crystal (LBO, 6×6×10, Θ=90°, Φ=11.4°) is only about 50%, as well as the second (GTR-KTP, 7×7×7, θ=90°, Φ=23.5‡). But the conversion efficiency of the last crystal (LBO, 6×6×15, θ=90°, Φ=0°), reaches 68% and the output power of 532 nm as high as 50 W is obtained.
- Open Access
- 31 January 2020
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 8
High-efficiency 50 W burst-mode hundred picosecond green laser
We report high-energy, high-efficiency second harmonic generation in a near-infrared all-solid-state burst-mode picosecond laser at a repetition rate of 1 kHz with four pulses per burst using a type-I noncritical phase-matching lithium triborate crystal. The pulses in each burst have the same time delay ( ${\sim}1~\text{ns}$ ), the same pulse duration ( ${\sim}100~\text{ps}$ ) and different relative amplitudes that can be adjusted separately. A mode-locked beam from a semiconductor saturable absorber mirror is pulse-stretched, split into seed pulses and injected into a Nd:YAG regenerative amplifier. After the beam is reshaped by aspheric lenses, a two-stage master oscillator power amplifier and 4f imaging systems are applied to obtain a high power of ${\sim}100~\text{W}$ . The 532 nm green laser has a maximum conversion efficiency of 68%, an average power of up to 50 W and a beam quality factor $M^{2}$ of 3.5.- 31 January 2020
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 8
Open AccessHigh-efficiency 50 W burst-mode hundred picosecond green laser
We report high-energy, high-efficiency second harmonic generation in a near-infrared all-solid-state burst-mode picosecond laser at a repetition rate of 1 kHz with four pulses per burst using a type-I noncritical phase-matching lithium triborate crystal. The pulses in each burst have the same time delay ( ${\sim}1~\text{ns}$ ), the same pulse duration ( ${\sim}100~\text{ps}$ ) and different relative amplitudes that can be adjusted separately. A mode-locked beam from a semiconductor saturable absorber mirror is pulse-stretched, split into seed pulses and injected into a Nd:YAG regenerative amplifier. After the beam is reshaped by aspheric lenses, a two-stage master oscillator power amplifier and 4f imaging systems are applied to obtain a high power of ${\sim}100~\text{W}$ . The 532 nm green laser has a maximum conversion efficiency of 68%, an average power of up to 50 W and a beam quality factor $M^{2}$ of 3.5.