Elena Golub
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Elena Golub has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ivan Dmitriev
Technische Universität Graz
2 shared publications Marina Gravit
Peter the Great St. Petersburg Polytechnic University, St. Petersburg, Russian Federation
2 shared publications- Marina Gravit
Peter the Great St. Petersburg Polytechnic University
2 shared publications - Boris Klementev
Department of Expertise, LLC “Arctic LNG 2”, 117393 Moscow, Russia
1 shared publication - Sergey Zimin
Peter the Great St. Petersburg Polytechnic University
1 shared publication - Yuriy Lazarev
Peter the Great St. Petersburg Polytechnic University
1 shared publication
Latest Publications
- Open Access
Fire Protective Glass Fiber Reinforced Concrete Plates for Steel Structures under Different Types of Fire Exposure
In a situation where a fire occurs either in a tunnel with a burning vehicle carrying petroleum products, at an offshore platform, or at an oil and gas asset to be protected, such a case is commonly described using a hydrocarbon fire curve. Therefore, it is extremely important to design construction, which can maintain stability and bearing capacity both under the standard and hydrocarbon fire modes. The purpose in this work is to hold a behavior simulation of a steel structure with fireproofing ensured through lightweight concrete slabs reinforced with fiber glass as well as a validation of the outcomes by assessing the experimental findings obtained from the relevant fire tests. A fire resistance study was carried out here for steel structures with a profile ratio of 156 mm−1 for the cases of a standard fire and of a hydrocarbon fire. A constant static load of 687 kN (70 tf) was taken for standard fire and 294 kN (30 tf) for hydrocarbon fire; the column was under vertical compression with one end resting on a hinged support and the other end rigidly fixed. The specimen design incorporated single-layer box-section cladding made of Pyro-Safe Aestuver T slabs, 40 mm thick and of a 650 kg/m3 density, pre-cut to fit the column size. The column strength loss (R) ultimately occurred after 240 min in the standard fire case and after 180 min in the hydrocarbon fire case. As the breach in the fireproofing structural integrity (E) or the installation accuracy cannot be considered, the limit state indicators may show certain discrepancies. According to the simulation performed using SOFiSTiK software, the design fire resistance rating of the structure in a hydrocarbon fire case was 58% higher than the figure obtained by holding fire tests due to the slabs cracking during the experiment session; the discrepancy between the outcomes of the session and the simulation in a standard fire case was as much as 15%.
Open AccessFire Protective Glass Fiber Reinforced Concrete Plates for Steel Structures under Different Types of Fire Exposure
In a situation where a fire occurs either in a tunnel with a burning vehicle carrying petroleum products, at an offshore platform, or at an oil and gas asset to be protected, such a case is commonly described using a hydrocarbon fire curve. Therefore, it is extremely important to design construction, which can maintain stability and bearing capacity both under the standard and hydrocarbon fire modes. The purpose in this work is to hold a behavior simulation of a steel structure with fireproofing ensured through lightweight concrete slabs reinforced with fiber glass as well as a validation of the outcomes by assessing the experimental findings obtained from the relevant fire tests. A fire resistance study was carried out here for steel structures with a profile ratio of 156 mm−1 for the cases of a standard fire and of a hydrocarbon fire. A constant static load of 687 kN (70 tf) was taken for standard fire and 294 kN (30 tf) for hydrocarbon fire; the column was under vertical compression with one end resting on a hinged support and the other end rigidly fixed. The specimen design incorporated single-layer box-section cladding made of Pyro-Safe Aestuver T slabs, 40 mm thick and of a 650 kg/m3 density, pre-cut to fit the column size. The column strength loss (R) ultimately occurred after 240 min in the standard fire case and after 180 min in the hydrocarbon fire case. As the breach in the fireproofing structural integrity (E) or the installation accuracy cannot be considered, the limit state indicators may show certain discrepancies. According to the simulation performed using SOFiSTiK software, the design fire resistance rating of the structure in a hydrocarbon fire case was 58% higher than the figure obtained by holding fire tests due to the slabs cracking during the experiment session; the discrepancy between the outcomes of the session and the simulation in a standard fire case was as much as 15%.
- 31 January 2020
- Published by Springer Nature
- p. 365-376
Fire Simulation of Bearing Structures for Natural Gas Module Plant
- 31 January 2020
- Published by Springer Nature
- p. 365-376
Fire Simulation of Bearing Structures for Natural Gas Module Plant
- Open Access
- 5 December 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 245, 03004
The fire resistant ceiling construction in a hydrocarbon fire
Fire protection of building structures under the hydrocarbon fire is becoming more relevant, especially in the design and construction of oil and gas and chemical complex facilities, including offshore fixed platforms, liquefied natural gas production and storage facilities and other objects of the fuel and energy complex. The development dynamics of such a fire requires a different approach to testing the structures in order to determine the fire resistance limit. The fire resistance tests of a steel horizontal structure with a fire resistance suspended ceiling of PROMATECT-T plates were carried out under the condition of creating a hydrocarbon temperature combustion regime. A detailed description of the tested ceiling design is given. It is shown that at the time of the end of the fire action, the limit state due to the loss of load capacity (R) and loss of integrity (E) was not recorded when the test reached 120 minutes.
- 5 December 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 245, 03004
Open AccessThe fire resistant ceiling construction in a hydrocarbon fire
Fire protection of building structures under the hydrocarbon fire is becoming more relevant, especially in the design and construction of oil and gas and chemical complex facilities, including offshore fixed platforms, liquefied natural gas production and storage facilities and other objects of the fuel and energy complex. The development dynamics of such a fire requires a different approach to testing the structures in order to determine the fire resistance limit. The fire resistance tests of a steel horizontal structure with a fire resistance suspended ceiling of PROMATECT-T plates were carried out under the condition of creating a hydrocarbon temperature combustion regime. A detailed description of the tested ceiling design is given. It is shown that at the time of the end of the fire action, the limit state due to the loss of load capacity (R) and loss of integrity (E) was not recorded when the test reached 120 minutes.
- Open Access
- 5 December 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 245, 03005
Increase of fire resistance of reinforced concrete structures with polypropylene microfiber
The increase in the construction of high-rise, technically complex buildings and structures is a prerequisite for the widespread use of structures of heavy concrete. In this work, a special type of destruction of this type of concrete is considered in the fire action explosive spalling. One method of protection is polypropylene microfiber, the objective of which is to increase the fire resistance of concrete and reinforced concrete structures. The fire resistance tests of the reinforced concrete structure with the use of microfiber and without it have been carried out. It is shown that polypropylene microfiber can completely prevent explosive spelling of concrete. In addition, the introduction of additives in the form of fibrous materials into the concrete mix is the most optimal from the point of view of labor intensity and material costs.
- 5 December 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 245, 03005
Open AccessIncrease of fire resistance of reinforced concrete structures with polypropylene microfiber
The increase in the construction of high-rise, technically complex buildings and structures is a prerequisite for the widespread use of structures of heavy concrete. In this work, a special type of destruction of this type of concrete is considered in the fire action explosive spalling. One method of protection is polypropylene microfiber, the objective of which is to increase the fire resistance of concrete and reinforced concrete structures. The fire resistance tests of the reinforced concrete structure with the use of microfiber and without it have been carried out. It is shown that polypropylene microfiber can completely prevent explosive spelling of concrete. In addition, the introduction of additives in the form of fibrous materials into the concrete mix is the most optimal from the point of view of labor intensity and material costs.