YXYuan Xing

Yuan Xing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuan Xing has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Shuxin Wang

    Key Lab for Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin 300000, China

    5 shared publications
  • Jinhua Li

    Key Lab for Mechanism Theory and Equipment Design of Ministry of Education Tianjin University Tianjin China

    4 shared publications
  • Honglei Wang

    Department of Gastrointestinal Surgery Tianjin Key Laboratory of Acute Abdomen Disease Associated Organ Injury and ITCWM Repair Tianjin Hospital of ITCWM Tianjin China

    3 shared publications
  • Jianmin Li

    School of Mechanical Engineering, Tianjin University, Tianjin, China

    3 shared publications
  • Ke Liang

    Key Lab for Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin 300000, China

    3 shared publications
  • Aimin Li

    Capital Med Univ, Beijing Luhe Hosp, Dept Surg, Beijing 100149, Peoples R China

    2 shared publications

Latest Publications

  • Preoperative Planning and Experimental Validation for Robot‐Assisted Minimally Invasive Surgery Based on a Clinical Evaluation System

    by Lei Gao, Yuan Xing, Yuan Bian, Jianchang Zhao, Xingchi Liu, Honglei Wang

    Background: Robot‐assisted minimally invasive surgery has effectively addressed the challenges faced by traditional minimally invasive surgery. Well‐designed preoperative planning is crucial for robot‐assisted minimally invasive surgery.Methods: This paper proposes a preoperative planning method based on a clinical evaluation system. The particle swarm optimisation algorithm and the evaluation indices including accessibility, visibility, operability, and hand‐eye coordination are adopted.Results: The simulation validation and the experimental verification were conducted to compare the pre‐operative planning scheme and the clinical scheme, taking the oesophageal hiatal hernia repair as an example. The preoperative planning scheme demonstrated superior accessibility and hand‐eye coordination, achieving shorter surgical time and reduced task load.Conclusion: The proposed preoperative planning method is feasible and effective through simulation and experimentation. This method has potential applications in various surgical robot systems and procedures, which can provide surgical guidance for surgeons in different departments.


  • Validation of a training system for laparoscopic longitudinal suturing in lesion

    by Yibo Tang, Min Chen, Yuan Xing, Yu Wang, Honglei Wang, Yunpeng Ji

    Background: A training system that allows the trainee to perform laparoscopic suturing in a realistic environment and measures the force applied to the tissue would be invaluable. This study aims to establish the construct and content validity of the training system we developed for the objective assessment of surgeons' skills.Methods: Ten novices, 6 residents, and 6 experts performed the suturing and knot‐tying task using the training system. Ten force‐related parameters were used to analyse the system's construct validity. Experts were invited to evaluate the content validity with questionnaires.Results: Eight parameters showed significant differences between the three groups. The construct validity results demonstrated that the system could distinguish the tissue handling ability of operators. The experts agreed that the system had excellent content validity with an average score of 4.71/5.Conclusions: The training system is likely valid for surgical training. It can realistically simulate surgical scenarios and evaluate the tissue handling ability of trainees.


  • Real‐time trajectory prediction of laparoscopic instrument tip based on long short‐term memory neural network in laparoscopic surgery training

    by Ziheng Wang, Zhengxiang Yan, Yuan Xing, Honglei Wang

    Background: To provide appropriate surgical training guidance, some skill evaluation and safety detection methods have been developed. However, these methods are difficult to provide predictive information for trainees. This paper proposes a new approach for real‐time trajectory prediction of the laparoscopic instrument tip to improve surgical training and the patient safety.Methods: This paper proposes a real‐time trajectory prediction model of laparoscopic instrument tip based on long short‐term memory (LSTM) neural network. Meanwhile, motion state is introduced to capture more motion information of the instrument tip and improve the model performance.Results: The feasibility, effectiveness and generalisation ability of this proposed model are preliminarily verified. The model shows satisfactory prediction accuracy for the trajectory of the laparoscopic instrument tip.Conclusion: LSTM neural network can accurately predict the movement trajectory of the laparoscopic instrument tip. The prediction model can play a critical role in operational risk perception in advance, which can be used in laparoscopic surgery training.


  • A Continuum Over Tube With Variable Stiffness for Transrectal NOTES

    by Jinhua Li, Lan Zhang, Yuan Xing, Rui Liu

    The continuum over tube applied to natural orifice transluminal endoscopic surgery (NOTES) should be flexible during insertion and provide sufficient stiffness upon arrival at the lesion. In order to satisfy these two properties, a variable stiffness continuum over tube was proposed. The over tube realizes stiffness variation through the heating and cooling of filling materials. Polyethylene glycol, cocoa butter, and gallium metal are selected as filling materials. Several experiments were designed to test its rigid and response characteristic, and suitable material was selected. The risk management test was carried out, and the frequency and risk level of the risk point were recorded. According to experimental data, the polyethylene glycol and gallium show better variable stiffness performance, with the 20 times stiffness variation range, and polyethylene glycol was selected as suitable materials for its low cost and nontoxic characteristic. The average heating time and cooling time of polyethylene glycol-filled over tube are 52.3 s and 36 s, respectively. Moreover, three kinds of high-frequency risk points including smoke, thread ejection, and uneven distribution of the material were found, and corresponding design improvement and use principle are proposed. The proposed continuum over tube can satisfy the requirement of colorectal NOTES for flexibility and stiffness of instruments, and the safety of the instrument can be improved by controlling high-frequency risk points with relevant methods.


  • An automatic skill evaluation framework for robotic surgery training

    by Wenjia Peng, Yuan Xing, Ruida Liu, Jinhua Li, Zemin Zhang

    Background: To provide feedback to surgeons in robotic surgery training, many surgical skill evaluation methods have been developed. However, they hardly focus on the performance of the surgical motion segments. This paper proposes a method of specifying a trainee's skill weakness in the surgical training.Methods: This paper proposed an automatic skill evaluation framework by comparing the trainees' operations with the template operation in each surgical motion segment, which is mainly based on dynamic time warping (DTW) and continuous hidden Markov model (CHMM).Results: The feasibility of this proposed framework has been preliminarily verified. For specifying the skill weakness in instrument handling and efficiency, the result of this proposed framework was significantly correlated with that of manual scoring.Conclusion: The automatic skill evaluation framework has shown its superiority in efficiency, objectivity, and being targeted, which can be used in robotic surgery training.


  • Motion control skill assessment based on kinematic analysis of robotic end‐effector movements

    by Ke Liang, Yuan Xing, Jianmin Li, Shuxin Wang, Aimin Li, Jinhua Li

    Background: The performance of robotic end‐effector movements can reflect the user's operation skill difference in robot‐assisted minimally invasive surgery. This study quantified the trade‐off of speed–accuracy–stability by kinematic analysis of robotic end‐effector movements to assess the motion control skill of users with different levels of experience.Methods: Using ‘MicroHand S’ system, 10 experts, 10 residents and 10 novices performed single‐hand test and bimanual coordination test. Eight metrics based on the movements of robotic end‐effectors were applied to evaluate the users' performance.Results: In the single‐hand test, experts outperformed other groups except for movement speed; in the bimanual coordination test, experts also performed better except for movement time and movement speed. No statistically significant difference in performance was found between residents and novices.Conclusions: The kinematic differences obtained from the movements of robotic end‐effectors can be applied to assess the motion control skill of users with different skill levels.


  • Modeling and evaluation of hand–eye coordination of surgical robotic system on task performance

    by Yuanqian Gao, Shuxin Wang, Jianmin Li, Aimin Li, Hongbin Liu, Yuan Xing

    Background: Robotic‐assisted minimally invasive surgery changes the direct hand and eye coordination in traditional surgery to indirect instrument and camera coordination, which affects the ergonomics, operation performance, and safety.Methods: A camera, two instruments, and a target, as the descriptors, are used to construct the workspace correspondence and geometrical relationships in a surgical operation. A parametric model with a set of parameters is proposed to describe the hand–eye coordination of the surgical robot.Results: From the results, optimal values and acceptable ranges of these parameters are identified from two tasks. A 90° viewing angle had the longest completion time; 60° instrument elevation angle and 0° deflection angle had better performance; there is no significant difference among manipulation angles and observing distances on task performance.Conclusion: This hand–eye coordination model provides evidence for robotic design, surgeon training, and robotic initialization to achieve dexterous and safe manipulation in surgery.