Yuan Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuan Xing has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Shuxin Wang
Key Lab for Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin 300000, China
5 shared publicationsJinhua Li
Key Lab for Mechanism Theory and Equipment Design of Ministry of Education Tianjin University Tianjin China
4 shared publicationsHonglei Wang
Department of Gastrointestinal Surgery Tianjin Key Laboratory of Acute Abdomen Disease Associated Organ Injury and ITCWM Repair Tianjin Hospital of ITCWM Tianjin China
3 shared publicationsJianmin Li
School of Mechanical Engineering, Tianjin University, Tianjin, China
3 shared publicationsKe Liang
Key Lab for Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin 300000, China
3 shared publications- Aimin Li
Capital Med Univ, Beijing Luhe Hosp, Dept Surg, Beijing 100149, Peoples R China
2 shared publications
Latest Publications
- 27 August 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (10) , 3721-3737
GDLS-D: two-stage medical surface reconstruction via geometric diffusion least squares and iterative deformation optimization
- 27 August 2026
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (10) , 3721-3737
GDLS-D: two-stage medical surface reconstruction via geometric diffusion least squares and iterative deformation optimization
- 17 February 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (1) , e70042
Preoperative Planning and Experimental Validation for Robot‐Assisted Minimally Invasive Surgery Based on a Clinical Evaluation System
Background: Robot‐assisted minimally invasive surgery has effectively addressed the challenges faced by traditional minimally invasive surgery. Well‐designed preoperative planning is crucial for robot‐assisted minimally invasive surgery.Methods: This paper proposes a preoperative planning method based on a clinical evaluation system. The particle swarm optimisation algorithm and the evaluation indices including accessibility, visibility, operability, and hand‐eye coordination are adopted.Results: The simulation validation and the experimental verification were conducted to compare the pre‐operative planning scheme and the clinical scheme, taking the oesophageal hiatal hernia repair as an example. The preoperative planning scheme demonstrated superior accessibility and hand‐eye coordination, achieving shorter surgical time and reduced task load.Conclusion: The proposed preoperative planning method is feasible and effective through simulation and experimentation. This method has potential applications in various surgical robot systems and procedures, which can provide surgical guidance for surgeons in different departments.
- 17 February 2025
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 21 (1) , e70042
Preoperative Planning and Experimental Validation for Robot‐Assisted Minimally Invasive Surgery Based on a Clinical Evaluation System
Background: Robot‐assisted minimally invasive surgery has effectively addressed the challenges faced by traditional minimally invasive surgery. Well‐designed preoperative planning is crucial for robot‐assisted minimally invasive surgery.Methods: This paper proposes a preoperative planning method based on a clinical evaluation system. The particle swarm optimisation algorithm and the evaluation indices including accessibility, visibility, operability, and hand‐eye coordination are adopted.Results: The simulation validation and the experimental verification were conducted to compare the pre‐operative planning scheme and the clinical scheme, taking the oesophageal hiatal hernia repair as an example. The preoperative planning scheme demonstrated superior accessibility and hand‐eye coordination, achieving shorter surgical time and reduced task load.Conclusion: The proposed preoperative planning method is feasible and effective through simulation and experimentation. This method has potential applications in various surgical robot systems and procedures, which can provide surgical guidance for surgeons in different departments.
- 9 November 2023
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (1) , e2594
Validation of a training system for laparoscopic longitudinal suturing in lesion
Background: A training system that allows the trainee to perform laparoscopic suturing in a realistic environment and measures the force applied to the tissue would be invaluable. This study aims to establish the construct and content validity of the training system we developed for the objective assessment of surgeons' skills.Methods: Ten novices, 6 residents, and 6 experts performed the suturing and knot‐tying task using the training system. Ten force‐related parameters were used to analyse the system's construct validity. Experts were invited to evaluate the content validity with questionnaires.Results: Eight parameters showed significant differences between the three groups. The construct validity results demonstrated that the system could distinguish the tissue handling ability of operators. The experts agreed that the system had excellent content validity with an average score of 4.71/5.Conclusions: The training system is likely valid for surgical training. It can realistically simulate surgical scenarios and evaluate the tissue handling ability of trainees.
- 9 November 2023
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 20 (1) , e2594
Validation of a training system for laparoscopic longitudinal suturing in lesion
Background: A training system that allows the trainee to perform laparoscopic suturing in a realistic environment and measures the force applied to the tissue would be invaluable. This study aims to establish the construct and content validity of the training system we developed for the objective assessment of surgeons' skills.Methods: Ten novices, 6 residents, and 6 experts performed the suturing and knot‐tying task using the training system. Ten force‐related parameters were used to analyse the system's construct validity. Experts were invited to evaluate the content validity with questionnaires.Results: Eight parameters showed significant differences between the three groups. The construct validity results demonstrated that the system could distinguish the tissue handling ability of operators. The experts agreed that the system had excellent content validity with an average score of 4.71/5.Conclusions: The training system is likely valid for surgical training. It can realistically simulate surgical scenarios and evaluate the tissue handling ability of trainees.
- 17 August 2022
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (6) , e2441
Real‐time trajectory prediction of laparoscopic instrument tip based on long short‐term memory neural network in laparoscopic surgery training
Background: To provide appropriate surgical training guidance, some skill evaluation and safety detection methods have been developed. However, these methods are difficult to provide predictive information for trainees. This paper proposes a new approach for real‐time trajectory prediction of the laparoscopic instrument tip to improve surgical training and the patient safety.Methods: This paper proposes a real‐time trajectory prediction model of laparoscopic instrument tip based on long short‐term memory (LSTM) neural network. Meanwhile, motion state is introduced to capture more motion information of the instrument tip and improve the model performance.Results: The feasibility, effectiveness and generalisation ability of this proposed model are preliminarily verified. The model shows satisfactory prediction accuracy for the trajectory of the laparoscopic instrument tip.Conclusion: LSTM neural network can accurately predict the movement trajectory of the laparoscopic instrument tip. The prediction model can play a critical role in operational risk perception in advance, which can be used in laparoscopic surgery training.
- 17 August 2022
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (6) , e2441
Real‐time trajectory prediction of laparoscopic instrument tip based on long short‐term memory neural network in laparoscopic surgery training
Background: To provide appropriate surgical training guidance, some skill evaluation and safety detection methods have been developed. However, these methods are difficult to provide predictive information for trainees. This paper proposes a new approach for real‐time trajectory prediction of the laparoscopic instrument tip to improve surgical training and the patient safety.Methods: This paper proposes a real‐time trajectory prediction model of laparoscopic instrument tip based on long short‐term memory (LSTM) neural network. Meanwhile, motion state is introduced to capture more motion information of the instrument tip and improve the model performance.Results: The feasibility, effectiveness and generalisation ability of this proposed model are preliminarily verified. The model shows satisfactory prediction accuracy for the trajectory of the laparoscopic instrument tip.Conclusion: LSTM neural network can accurately predict the movement trajectory of the laparoscopic instrument tip. The prediction model can play a critical role in operational risk perception in advance, which can be used in laparoscopic surgery training.
- 10 May 2022
- Published by ASME International in Journal of Medical Devices
- Vol. 16 (3)
A Continuum Over Tube With Variable Stiffness for Transrectal NOTES
The continuum over tube applied to natural orifice transluminal endoscopic surgery (NOTES) should be flexible during insertion and provide sufficient stiffness upon arrival at the lesion. In order to satisfy these two properties, a variable stiffness continuum over tube was proposed. The over tube realizes stiffness variation through the heating and cooling of filling materials. Polyethylene glycol, cocoa butter, and gallium metal are selected as filling materials. Several experiments were designed to test its rigid and response characteristic, and suitable material was selected. The risk management test was carried out, and the frequency and risk level of the risk point were recorded. According to experimental data, the polyethylene glycol and gallium show better variable stiffness performance, with the 20 times stiffness variation range, and polyethylene glycol was selected as suitable materials for its low cost and nontoxic characteristic. The average heating time and cooling time of polyethylene glycol-filled over tube are 52.3 s and 36 s, respectively. Moreover, three kinds of high-frequency risk points including smoke, thread ejection, and uneven distribution of the material were found, and corresponding design improvement and use principle are proposed. The proposed continuum over tube can satisfy the requirement of colorectal NOTES for flexibility and stiffness of instruments, and the safety of the instrument can be improved by controlling high-frequency risk points with relevant methods.
- 10 May 2022
- Published by ASME International in Journal of Medical Devices
- Vol. 16 (3)
A Continuum Over Tube With Variable Stiffness for Transrectal NOTES
The continuum over tube applied to natural orifice transluminal endoscopic surgery (NOTES) should be flexible during insertion and provide sufficient stiffness upon arrival at the lesion. In order to satisfy these two properties, a variable stiffness continuum over tube was proposed. The over tube realizes stiffness variation through the heating and cooling of filling materials. Polyethylene glycol, cocoa butter, and gallium metal are selected as filling materials. Several experiments were designed to test its rigid and response characteristic, and suitable material was selected. The risk management test was carried out, and the frequency and risk level of the risk point were recorded. According to experimental data, the polyethylene glycol and gallium show better variable stiffness performance, with the 20 times stiffness variation range, and polyethylene glycol was selected as suitable materials for its low cost and nontoxic characteristic. The average heating time and cooling time of polyethylene glycol-filled over tube are 52.3 s and 36 s, respectively. Moreover, three kinds of high-frequency risk points including smoke, thread ejection, and uneven distribution of the material were found, and corresponding design improvement and use principle are proposed. The proposed continuum over tube can satisfy the requirement of colorectal NOTES for flexibility and stiffness of instruments, and the safety of the instrument can be improved by controlling high-frequency risk points with relevant methods.
- 23 February 2022
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 22 (2) , 724-737
An Analysis on the Engineering Failure of the Wire Rope Used in Surgical Instruments
- 23 February 2022
- Published by Springer Nature in Journal of Failure Analysis and Prevention
- Vol. 22 (2) , 724-737
An Analysis on the Engineering Failure of the Wire Rope Used in Surgical Instruments
- 17 October 2018
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 15 (1) , e1964
An automatic skill evaluation framework for robotic surgery training
Background: To provide feedback to surgeons in robotic surgery training, many surgical skill evaluation methods have been developed. However, they hardly focus on the performance of the surgical motion segments. This paper proposes a method of specifying a trainee's skill weakness in the surgical training.Methods: This paper proposed an automatic skill evaluation framework by comparing the trainees' operations with the template operation in each surgical motion segment, which is mainly based on dynamic time warping (DTW) and continuous hidden Markov model (CHMM).Results: The feasibility of this proposed framework has been preliminarily verified. For specifying the skill weakness in instrument handling and efficiency, the result of this proposed framework was significantly correlated with that of manual scoring.Conclusion: The automatic skill evaluation framework has shown its superiority in efficiency, objectivity, and being targeted, which can be used in robotic surgery training.
- 17 October 2018
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 15 (1) , e1964
An automatic skill evaluation framework for robotic surgery training
Background: To provide feedback to surgeons in robotic surgery training, many surgical skill evaluation methods have been developed. However, they hardly focus on the performance of the surgical motion segments. This paper proposes a method of specifying a trainee's skill weakness in the surgical training.Methods: This paper proposed an automatic skill evaluation framework by comparing the trainees' operations with the template operation in each surgical motion segment, which is mainly based on dynamic time warping (DTW) and continuous hidden Markov model (CHMM).Results: The feasibility of this proposed framework has been preliminarily verified. For specifying the skill weakness in instrument handling and efficiency, the result of this proposed framework was significantly correlated with that of manual scoring.Conclusion: The automatic skill evaluation framework has shown its superiority in efficiency, objectivity, and being targeted, which can be used in robotic surgery training.
- 1 December 2017
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 152, 71-83
Evaluation of robotic surgery skills using dynamic time warping
- 1 December 2017
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 152, 71-83
Evaluation of robotic surgery skills using dynamic time warping
- 29 June 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (1)
Motion control skill assessment based on kinematic analysis of robotic end‐effector movements
Background: The performance of robotic end‐effector movements can reflect the user's operation skill difference in robot‐assisted minimally invasive surgery. This study quantified the trade‐off of speed–accuracy–stability by kinematic analysis of robotic end‐effector movements to assess the motion control skill of users with different levels of experience.Methods: Using ‘MicroHand S’ system, 10 experts, 10 residents and 10 novices performed single‐hand test and bimanual coordination test. Eight metrics based on the movements of robotic end‐effectors were applied to evaluate the users' performance.Results: In the single‐hand test, experts outperformed other groups except for movement speed; in the bimanual coordination test, experts also performed better except for movement time and movement speed. No statistically significant difference in performance was found between residents and novices.Conclusions: The kinematic differences obtained from the movements of robotic end‐effectors can be applied to assess the motion control skill of users with different skill levels.
- 29 June 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (1)
Motion control skill assessment based on kinematic analysis of robotic end‐effector movements
Background: The performance of robotic end‐effector movements can reflect the user's operation skill difference in robot‐assisted minimally invasive surgery. This study quantified the trade‐off of speed–accuracy–stability by kinematic analysis of robotic end‐effector movements to assess the motion control skill of users with different levels of experience.Methods: Using ‘MicroHand S’ system, 10 experts, 10 residents and 10 novices performed single‐hand test and bimanual coordination test. Eight metrics based on the movements of robotic end‐effectors were applied to evaluate the users' performance.Results: In the single‐hand test, experts outperformed other groups except for movement speed; in the bimanual coordination test, experts also performed better except for movement time and movement speed. No statistically significant difference in performance was found between residents and novices.Conclusions: The kinematic differences obtained from the movements of robotic end‐effectors can be applied to assess the motion control skill of users with different skill levels.
- 4 May 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 13 (4) , e1829
Modeling and evaluation of hand–eye coordination of surgical robotic system on task performance
Background: Robotic‐assisted minimally invasive surgery changes the direct hand and eye coordination in traditional surgery to indirect instrument and camera coordination, which affects the ergonomics, operation performance, and safety.Methods: A camera, two instruments, and a target, as the descriptors, are used to construct the workspace correspondence and geometrical relationships in a surgical operation. A parametric model with a set of parameters is proposed to describe the hand–eye coordination of the surgical robot.Results: From the results, optimal values and acceptable ranges of these parameters are identified from two tasks. A 90° viewing angle had the longest completion time; 60° instrument elevation angle and 0° deflection angle had better performance; there is no significant difference among manipulation angles and observing distances on task performance.Conclusion: This hand–eye coordination model provides evidence for robotic design, surgeon training, and robotic initialization to achieve dexterous and safe manipulation in surgery.
- 4 May 2017
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 13 (4) , e1829
Modeling and evaluation of hand–eye coordination of surgical robotic system on task performance
Background: Robotic‐assisted minimally invasive surgery changes the direct hand and eye coordination in traditional surgery to indirect instrument and camera coordination, which affects the ergonomics, operation performance, and safety.Methods: A camera, two instruments, and a target, as the descriptors, are used to construct the workspace correspondence and geometrical relationships in a surgical operation. A parametric model with a set of parameters is proposed to describe the hand–eye coordination of the surgical robot.Results: From the results, optimal values and acceptable ranges of these parameters are identified from two tasks. A 90° viewing angle had the longest completion time; 60° instrument elevation angle and 0° deflection angle had better performance; there is no significant difference among manipulation angles and observing distances on task performance.Conclusion: This hand–eye coordination model provides evidence for robotic design, surgeon training, and robotic initialization to achieve dexterous and safe manipulation in surgery.