Daniela Muenzel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniela Muenzel has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Peter Benjamin Noël
Department of Radiology Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
6 shared publications Ernst J. Rummeny
Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Ismaningerstrasse 22, 81675, München, Germany
4 shared publicationsAlexander A. Fingerle
Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Ismaningerstrasse 22, 81675, München, Germany
3 shared publications- Ernst J. Rummeny
Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
2 shared publications Martin Dobritz
Department of Radiology, Technische Universität München, Ismaningerstr. 22, 81675 Munich, Germany
2 shared publicationsTina Zahel
Department of Radiology, Technische Universität München, Ismaningerstr. 22, 81675 Munich, Germany
2 shared publications
Latest Publications
- Open Access
- 22 December 2017
- Published by Springer Nature in European Radiology Experimental
- Vol. 1 (1) , 1-9
Simultaneous dual-contrast multi-phase liver imaging using spectral photon-counting computed tomography: a proof-of-concept study
To assess the feasibility of dual-contrast spectral photon-counting computed tomography (SPCCT) for liver imaging. We present an SPCCT in-silico study for simultaneous mapping of the complementary distribution in the liver of two contrast agents (CAs) subsequently intravenously injected: a gadolinium-based contrast agent and an iodine-based contrast agent. Four types of simulated liver lesions with a characteristic arterial and portal venous pattern (haemangioma, hepatocellular carcinoma, cyst, and metastasis) are presented. A material decomposition was performed to reconstruct quantitative iodine and gadolinium maps. Finally, a multi-dimensional classification algorithm for automatic lesion detection is presented. Our simulations showed that with a single-scan SPCCT and an adapted contrast injection protocol, it was possible to reconstruct contrast-enhanced images of the liver with arterial distribution of the iodine-based CA and portal venous phase of the gadolinium-based CA. The characteristic patterns of contrast enhancement were visible in all liver lesions. The approach allowed for an automatic detection and classification of liver lesions using a multi-dimensional analysis. Dual-contrast SPCCT should be able to visualise the characteristic arterial and portal venous enhancement with a single scan, allowing for an automatic lesion detection and characterisation, with a reduced radiation exposure.
- 22 December 2017
- Published by Springer Nature in European Radiology Experimental
- Vol. 1 (1) , 1-9
Open AccessSimultaneous dual-contrast multi-phase liver imaging using spectral photon-counting computed tomography: a proof-of-concept study
To assess the feasibility of dual-contrast spectral photon-counting computed tomography (SPCCT) for liver imaging. We present an SPCCT in-silico study for simultaneous mapping of the complementary distribution in the liver of two contrast agents (CAs) subsequently intravenously injected: a gadolinium-based contrast agent and an iodine-based contrast agent. Four types of simulated liver lesions with a characteristic arterial and portal venous pattern (haemangioma, hepatocellular carcinoma, cyst, and metastasis) are presented. A material decomposition was performed to reconstruct quantitative iodine and gadolinium maps. Finally, a multi-dimensional classification algorithm for automatic lesion detection is presented. Our simulations showed that with a single-scan SPCCT and an adapted contrast injection protocol, it was possible to reconstruct contrast-enhanced images of the liver with arterial distribution of the iodine-based CA and portal venous phase of the gadolinium-based CA. The characteristic patterns of contrast enhancement were visible in all liver lesions. The approach allowed for an automatic detection and classification of liver lesions using a multi-dimensional analysis. Dual-contrast SPCCT should be able to visualise the characteristic arterial and portal venous enhancement with a single scan, allowing for an automatic lesion detection and characterisation, with a reduced radiation exposure.
- 1 October 2017
- Published by Elsevier in European Journal of Radiology
- Vol. 95, 300-306
Material density iodine images in dual-energy CT: Detection and characterization of hypervascular liver lesions compared to magnetic resonance imaging
- 1 October 2017
- Published by Elsevier in European Journal of Radiology
- Vol. 95, 300-306
Material density iodine images in dual-energy CT: Detection and characterization of hypervascular liver lesions compared to magnetic resonance imaging
- Open Access
- 23 September 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (9) , e107843
Validation of a Low Dose Simulation Technique for Computed Tomography Images
Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10–80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was −1.2% (range −9% to 3.2%) and −0.2% (range −8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9–10.2 HU (noise) and 1.9–13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.
- 23 September 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (9) , e107843
Open AccessValidation of a Low Dose Simulation Technique for Computed Tomography Images
Evaluation of a new software tool for generation of simulated low-dose computed tomography (CT) images from an original higher dose scan. Original CT scan data (100 mAs, 80 mAs, 60 mAs, 40 mAs, 20 mAs, 10 mAs; 100 kV) of a swine were acquired (approved by the regional governmental commission for animal protection). Simulations of CT acquisition with a lower dose (simulated 10–80 mAs) were calculated using a low-dose simulation algorithm. The simulations were compared to the originals of the same dose level with regard to density values and image noise. Four radiologists assessed the realistic visual appearance of the simulated images. Image characteristics of simulated low dose scans were similar to the originals. Mean overall discrepancy of image noise and CT values was −1.2% (range −9% to 3.2%) and −0.2% (range −8.2% to 3.2%), respectively, p>0.05. Confidence intervals of discrepancies ranged between 0.9–10.2 HU (noise) and 1.9–13.4 HU (CT values), without significant differences (p>0.05). Subjective observer evaluation of image appearance showed no visually detectable difference. Simulated low dose images showed excellent agreement with the originals concerning image noise, CT density values, and subjective assessment of the visual appearance of the simulated images. An authentic low-dose simulation opens up opportunity with regard to staff education, protocol optimization and introduction of new techniques.
- Open Access
- 9 October 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (10) , e75263
Dynamic CT Perfusion Imaging of the Myocardium: A Technical Note on Improvement of Image Quality
To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI) by using motion compensation and a spatio-temporal filter. Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT). Data from two different patients–with and without myocardial perfusion defects–were evaluated to illustrate potential improvements for MPI (institutional review board approved). Three datasets for each patient were generated: (i) original data (ii) motion compensated data and (iii) motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR) were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI) placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.
- 9 October 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (10) , e75263
Open AccessDynamic CT Perfusion Imaging of the Myocardium: A Technical Note on Improvement of Image Quality
To improve image and diagnostic quality in dynamic CT myocardial perfusion imaging (MPI) by using motion compensation and a spatio-temporal filter. Dynamic CT MPI was performed using a 256-slice multidetector computed tomography scanner (MDCT). Data from two different patients–with and without myocardial perfusion defects–were evaluated to illustrate potential improvements for MPI (institutional review board approved). Three datasets for each patient were generated: (i) original data (ii) motion compensated data and (iii) motion compensated data with spatio-temporal filtering performed. In addition to the visual assessment of the tomographic slices, noise and contrast-to-noise-ratio (CNR) were measured for all data. Perfusion analysis was performed using time-density curves with regions-of-interest (ROI) placed in normal and hypoperfused myocardium. Precision in definition of normal and hypoperfused areas was determined in corresponding coloured perfusion maps. The use of motion compensation followed by spatio-temporal filtering resulted in better alignment of the cardiac volumes over time leading to a more consistent perfusion quantification and improved detection of the extend of perfusion defects. Additionally image noise was reduced by 78.5%, with CNR improvements by a factor of 4.7. The average effective radiation dose estimate was 7.1±1.1 mSv. The use of motion compensation and spatio-temporal smoothing will result in improved quantification of dynamic CT MPI using a latest generation CT scanner.
- 31 July 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (7) , 1562-1568
Coronary CT angiography in step-and-shoot technique with 256-slice CT: Impact of the field of view on image quality, craniocaudal coverage, and radiation exposure
- 31 July 2012
- Published by Elsevier in European Journal of Radiology
- Vol. 81 (7) , 1562-1568
Coronary CT angiography in step-and-shoot technique with 256-slice CT: Impact of the field of view on image quality, craniocaudal coverage, and radiation exposure
- Open Access
- 1 January 2012
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 46 (1) , 8-18
Intra- and inter-observer variability in measurement of target lesions: implication on response evaluation according to RECIST 1.1
The assessment of cancer treatment in oncological clinical trials is usually based on serial measurements of tumours' size according to the Response Evaluation Criteria in Solid Tumours (RECIST) guidelines. The aim of our study was to evaluate the variability of measurements of target lesions by readers as well as the impact on response evaluation, workflow and reporting. Twenty oncologic patients were included to the study with CT examinations from thorax to pelvis performed at a 64 slices CT scanner. Four readers defined and measured the size of target lesions independently at baseline and follow-up with PACS (Picture Archiving and Communication System) and LMS (Lesion Management Solutions, Median technologies, Valbonne Sophia Antipolis, France), according to the RECIST 1.1 criteria. Variability in measurements using PACS or LMS software was established with the Bland and Altman approach. The inter- and intra-observer variabilities were calculated for identical lesions and the overall response per case was determined. In addition, time required for evaluation and reporting in each case was recorded. For single lesions, the median intra-observer variability ranged from 4.9-9.6% (mean 5.9%) and the median inter-observer variability from 4.3-11.4% (mean 7.1%), respecting different evaluation time points, image systems and observers. Nevertheless, the variability in change of Δ sum longest diameter (LD), mandatory for classification of the overall response, was 24%. The overall response evaluation assessed by a single respectively different observer was discrepant in 6.3% respectively 12% of the cases compared with the mean results of multiple observers. The mean case evaluation time was 286s vs. 228s at baseline and 267s vs. 196s at follow-up for PACS and LMS, respectively. Uni-dimensional measurements of target lesions show low intra- and inter-observer variabilities, but the high variability in change of Δ sum LD shows the potential for misclassification of the overall response according to the RECIST 1.1 guidelines. Nevertheless, the reproducibility of RECIST reporting can be improved for the case assessment by a single observer and by mean results of multiple observers. Case-based evaluation time was shortened up to 27% using custom software.
- 1 January 2012
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 46 (1) , 8-18
Open AccessIntra- and inter-observer variability in measurement of target lesions: implication on response evaluation according to RECIST 1.1
The assessment of cancer treatment in oncological clinical trials is usually based on serial measurements of tumours' size according to the Response Evaluation Criteria in Solid Tumours (RECIST) guidelines. The aim of our study was to evaluate the variability of measurements of target lesions by readers as well as the impact on response evaluation, workflow and reporting. Twenty oncologic patients were included to the study with CT examinations from thorax to pelvis performed at a 64 slices CT scanner. Four readers defined and measured the size of target lesions independently at baseline and follow-up with PACS (Picture Archiving and Communication System) and LMS (Lesion Management Solutions, Median technologies, Valbonne Sophia Antipolis, France), according to the RECIST 1.1 criteria. Variability in measurements using PACS or LMS software was established with the Bland and Altman approach. The inter- and intra-observer variabilities were calculated for identical lesions and the overall response per case was determined. In addition, time required for evaluation and reporting in each case was recorded. For single lesions, the median intra-observer variability ranged from 4.9-9.6% (mean 5.9%) and the median inter-observer variability from 4.3-11.4% (mean 7.1%), respecting different evaluation time points, image systems and observers. Nevertheless, the variability in change of Δ sum longest diameter (LD), mandatory for classification of the overall response, was 24%. The overall response evaluation assessed by a single respectively different observer was discrepant in 6.3% respectively 12% of the cases compared with the mean results of multiple observers. The mean case evaluation time was 286s vs. 228s at baseline and 267s vs. 196s at follow-up for PACS and LMS, respectively. Uni-dimensional measurements of target lesions show low intra- and inter-observer variabilities, but the high variability in change of Δ sum LD shows the potential for misclassification of the overall response according to the RECIST 1.1 guidelines. Nevertheless, the reproducibility of RECIST reporting can be improved for the case assessment by a single observer and by mean results of multiple observers. Case-based evaluation time was shortened up to 27% using custom software.
- 28 June 2011
- Published by Springer Nature in European Radiology
- Vol. 21 (11) , 2277-2284
Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality
To evaluate the effect of heart rate variability (HRV) and heart rate (HR) on intra-image “motion” and inter-image “stairstep” artefacts in step-and-shoot coronary CT angiography (CCTA) using a wide detector CT scanner.
- 28 June 2011
- Published by Springer Nature in European Radiology
- Vol. 21 (11) , 2277-2284
Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality
To evaluate the effect of heart rate variability (HRV) and heart rate (HR) on intra-image “motion” and inter-image “stairstep” artefacts in step-and-shoot coronary CT angiography (CCTA) using a wide detector CT scanner.
- 29 April 2011
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 183 (S 01) , WI_PO18
„Chest pain“ CT Untersuchungen mit prospektiver EKG-Triggerung: erste Erfahrungen mit einem 256 Zeilen CT Scanner
Ziele: Ziel war die Evaluation eines prospektiv EKG-getriggerten sogenannten „Chest-pain“ CT Protokolls für eine kombinierte Untersuchungstechnik zum Nachweis bzw. Ausschluss einer Lungenarterienembolie, einer koronaren Herzerkrankung (KHK) und einer Aortendissektion. Methode: 40 Patienten mit akuten Thoraxschmerzen wurden mit einem prospektiv EKG-getriggerten CT-Thorax-Protokoll an einem 256-Zeilen CT Scanner (Brilliance iCT, Philips) untersucht. Die Kontrastierung sowie das Signal-zu-Rausch-Verhältnis in der Aorta ascendens, der Koronargefäße und des Pulmonalarterienhauptstammes wurden bestimmt. Alle Untersuchungen wurden hinsichtlich der diagnostischen Ergebnisse evaluiert und der klinische Verlauf bis zu einem Monat wurde dokumentiert. Die effektive Strahlendosis wurde anhand des Dosislängenproduktes abgeschätzt. Ergebnis: Diagnostische Bildqualität der thorakalen Aorta und der (sub-)segmentalen Äste der Pulmonalarterien wurde in allen Untersuchungen sowie in 91% der Koronararteriensegmente erreicht. Das Signal-zu-Rausch-Verhältnis betrug 34,5 (Aorta ascendens), 30,8 (Pulmonalarterienhauptstamm), 32,7 (RCA), 33,0 (Hauptstamm), 36,3 (RIVA) and 27,9 (RCX). Die häufigsten Diagnosen waren: KHK (11 Patienten, davon 4 mit Verdacht auf hämodynamische Relevanz der koronararteriellen Stenosierung), Lungenarterienembolie (5 Patienten) und Erkrankungen der Aorta (6 Patienten: 3 Aneurymata, 1 akute Aortendissektion, 1 ausgeprägte Atherosklerose der Aorta mit ulzerierenden Plaques, 1 Coactatio aortae). Spinale Ischemie (1), Pneumonie (3) und Bronchialkarzinom (2) wurden in einzelnen Patienten als vermutliche Ursache der thorakalen Beschwerden gefunden. Bei 12 Patienten war kein eindeutiger Befund zu diagnostizieren. Die mittlere effektive Strahlendosis der CT Untersuchungen war 11,2 mSv (SD 2,2). Schlussfolgerung: Ein prospektiv EKG-getriggertes “chest pain“ Protokoll an einem 256 Zeilen CT Scanner ist eine sehr gute Untersuchungstechnik zur Evaluation der häufigsten Ursachen des akuten Thoraxschmerzes. Keywords: CT Angiographie, chest pain, Signal-zu-Rausch-Verhältnis, Strahlendosis Korrespondierender Autor: Muenzel D Klinikum rechts der Isar der Technischen Universität München, Radiologie, Ismaninger Str. 22, 81675 München E-Mail: muenzel@tum.de
- 29 April 2011
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 183 (S 01) , WI_PO18
„Chest pain“ CT Untersuchungen mit prospektiver EKG-Triggerung: erste Erfahrungen mit einem 256 Zeilen CT Scanner
Ziele: Ziel war die Evaluation eines prospektiv EKG-getriggerten sogenannten „Chest-pain“ CT Protokolls für eine kombinierte Untersuchungstechnik zum Nachweis bzw. Ausschluss einer Lungenarterienembolie, einer koronaren Herzerkrankung (KHK) und einer Aortendissektion. Methode: 40 Patienten mit akuten Thoraxschmerzen wurden mit einem prospektiv EKG-getriggerten CT-Thorax-Protokoll an einem 256-Zeilen CT Scanner (Brilliance iCT, Philips) untersucht. Die Kontrastierung sowie das Signal-zu-Rausch-Verhältnis in der Aorta ascendens, der Koronargefäße und des Pulmonalarterienhauptstammes wurden bestimmt. Alle Untersuchungen wurden hinsichtlich der diagnostischen Ergebnisse evaluiert und der klinische Verlauf bis zu einem Monat wurde dokumentiert. Die effektive Strahlendosis wurde anhand des Dosislängenproduktes abgeschätzt. Ergebnis: Diagnostische Bildqualität der thorakalen Aorta und der (sub-)segmentalen Äste der Pulmonalarterien wurde in allen Untersuchungen sowie in 91% der Koronararteriensegmente erreicht. Das Signal-zu-Rausch-Verhältnis betrug 34,5 (Aorta ascendens), 30,8 (Pulmonalarterienhauptstamm), 32,7 (RCA), 33,0 (Hauptstamm), 36,3 (RIVA) and 27,9 (RCX). Die häufigsten Diagnosen waren: KHK (11 Patienten, davon 4 mit Verdacht auf hämodynamische Relevanz der koronararteriellen Stenosierung), Lungenarterienembolie (5 Patienten) und Erkrankungen der Aorta (6 Patienten: 3 Aneurymata, 1 akute Aortendissektion, 1 ausgeprägte Atherosklerose der Aorta mit ulzerierenden Plaques, 1 Coactatio aortae). Spinale Ischemie (1), Pneumonie (3) und Bronchialkarzinom (2) wurden in einzelnen Patienten als vermutliche Ursache der thorakalen Beschwerden gefunden. Bei 12 Patienten war kein eindeutiger Befund zu diagnostizieren. Die mittlere effektive Strahlendosis der CT Untersuchungen war 11,2 mSv (SD 2,2). Schlussfolgerung: Ein prospektiv EKG-getriggertes “chest pain“ Protokoll an einem 256 Zeilen CT Scanner ist eine sehr gute Untersuchungstechnik zur Evaluation der häufigsten Ursachen des akuten Thoraxschmerzes. Keywords: CT Angiographie, chest pain, Signal-zu-Rausch-Verhältnis, Strahlendosis Korrespondierender Autor: Muenzel D Klinikum rechts der Isar der Technischen Universität München, Radiologie, Ismaninger Str. 22, 81675 München E-Mail: muenzel@tum.de