Jiajun Yu
Jiajun Yu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Zhizhi He
4 shared publicationsZongjian Li
4 shared publicationsJun Wang
Hunan University,College of Electrical and Information EngineeringChangshaChina
3 shared publicationsXi Jiang
3 shared publicationsChao Zhang
1 shared publication- Jun Wang
Hunan University
1 shared publication
Latest Publications
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (1) , 42-53
Performance Comparison of Two Hybrid Si/SiC Device Concepts
- 14 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (1) , 42-53
Performance Comparison of Two Hybrid Si/SiC Device Concepts
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4558-4561
Multi-Objective Optimization Control Strategy for SiC/Si Hybrid Switches
This paper presents a multi-objective optimization control strategy for SiC/Si hybrid switch (HyS) based on its electro-thermal coupled loss model. The new control method aims to achieve the highest conversion efficiency under light to medium load condition and balanced junction temperatures under heavy load condition by dynamically adjusting the turn-off delay time between the MOSFET and IGBT. An analytical electro-thermal power loss model is developed for the hybrid switch. Experimental results on a 8kW, 20kHz DC/DC buck converter using SiC/Si hybrid switches demonstrate that the new control strategy achieves 18% higher maximum power handling capability and 30ºC lower maximum junction temperature (at 8kW output) than the fixed delay time control approach previously reported. In addition, the conversion efficiency increases by 0.3% under light load condition (at 4kW).
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4558-4561
Multi-Objective Optimization Control Strategy for SiC/Si Hybrid Switches
This paper presents a multi-objective optimization control strategy for SiC/Si hybrid switch (HyS) based on its electro-thermal coupled loss model. The new control method aims to achieve the highest conversion efficiency under light to medium load condition and balanced junction temperatures under heavy load condition by dynamically adjusting the turn-off delay time between the MOSFET and IGBT. An analytical electro-thermal power loss model is developed for the hybrid switch. Experimental results on a 8kW, 20kHz DC/DC buck converter using SiC/Si hybrid switches demonstrate that the new control strategy achieves 18% higher maximum power handling capability and 30ºC lower maximum junction temperature (at 8kW output) than the fixed delay time control approach previously reported. In addition, the conversion efficiency increases by 0.3% under light load condition (at 4kW).
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1988-1991
Performance Improvement of Dual Active Bridge DC-DC Converter Using Cost-Effectiveness Si/SiC Hybrid Switch
IGBT or SiC devices are used in the high voltage side bridge of the dual active bridge (DAB) converters to sustain high voltage of kV range. However, the large hard switching turn-off loss of the IGBT restricts the maximum switching frequency and efficiency improvement of the DAB converter, while the much higher SiC material and fabrication cost results in a high cost/ampere ($/A) of SiC MOSFETs and hinders their widespread adoption in the market. In this paper, a cost-effectiveness Si/SiC hybrid switch consisting of a high current Si IGBT and a low current SiC MOSFET is implemented in the bidirectional isolation dual active bridge (DAB) converter to achieve performance improvement without a significant cost penalty. Making use of the specific gate control pattern of the hybrid switch, the Si IGBT inside the hybrid switch could achieve the zero-voltage switching (ZVS) operation both at the turning-on and turning-off action, greatly reducing the total power loss of switching devices and increasing the switching frequency of the DAB converter. A hybrid modulation strategy of the hybrid switch is introduced into the DAB converter to eliminate the dual-side flow back currents and reduce the current stress of switching devices. The experimental results demonstrate that the Si/SiC hybrid switch based DAB converter can achieve 3% higher efficiency and 49 °C lower case temperature compared to the full IGBT solution at the same output power rating.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1988-1991
Performance Improvement of Dual Active Bridge DC-DC Converter Using Cost-Effectiveness Si/SiC Hybrid Switch
IGBT or SiC devices are used in the high voltage side bridge of the dual active bridge (DAB) converters to sustain high voltage of kV range. However, the large hard switching turn-off loss of the IGBT restricts the maximum switching frequency and efficiency improvement of the DAB converter, while the much higher SiC material and fabrication cost results in a high cost/ampere ($/A) of SiC MOSFETs and hinders their widespread adoption in the market. In this paper, a cost-effectiveness Si/SiC hybrid switch consisting of a high current Si IGBT and a low current SiC MOSFET is implemented in the bidirectional isolation dual active bridge (DAB) converter to achieve performance improvement without a significant cost penalty. Making use of the specific gate control pattern of the hybrid switch, the Si IGBT inside the hybrid switch could achieve the zero-voltage switching (ZVS) operation both at the turning-on and turning-off action, greatly reducing the total power loss of switching devices and increasing the switching frequency of the DAB converter. A hybrid modulation strategy of the hybrid switch is introduced into the DAB converter to eliminate the dual-side flow back currents and reduce the current stress of switching devices. The experimental results demonstrate that the Si/SiC hybrid switch based DAB converter can achieve 3% higher efficiency and 49 °C lower case temperature compared to the full IGBT solution at the same output power rating.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1918-1921
Performance Comparison of Traditional and JBS Integrated SiC MOSFETs in Si/SiC Hybrid Switch
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1918-1921
Performance Comparison of Traditional and JBS Integrated SiC MOSFETs in Si/SiC Hybrid Switch