Frans Vos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frans Vos has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
- Lucas J. van Vliet
Quantitative Imaging Group, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
16 shared publications Cristina Lavini
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
3 shared publicationsJaap Stoker
Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
3 shared publications- Jaap Stoker
Department of Radiology and Nuclear Medicine Amsterdam UMC, University of Amsterdam Amsterdam The Netherlands
3 shared publications - Matthan W. A. Caan
Biomedical Engineering and Physics, UMC Location University of Amsterdam, Amsterdam, The Netherlands
3 shared publications - Anushka A. Kore
TU Delft
2 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (10) , e70380
Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla
Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular characterization at 3 T. Higher field strength MRI offers increased contrast, resolution and signal‐to‐noise ratio, providing potential to improve microvascular characterization. This feasibility study aimed to implement a protocol for SAGE‐DSC at 7 T and study its potential for microvascular characterization. SAGE‐DSC was acquired in eight patients undergoing treatment for glioma (four females, median age 57 years) at 3 and 7 T. Data were analyzed using the temporal signal‐to‐noise ratio (tSNR) and contrast‐to‐noise ratio (CNR) and by comparing perfusion maps, VSI and vascular architectural imaging (VAI). Simulations were performed to study the relationship between vessel size and for SAGE‐DSC at 3 and 7 T. Contrast agent dosage could be reduced while maintaining higher CNR at 7 T (but lower tSNR). Assessment by an experienced neuroradiologist showed similar rCBV map quality at 3 and 7 T. VSI maps showed the same normal‐appearing gray‐to‐white matter ratios while in‐plane resolution improved at least 52% at 7 T. VAI hysteresis loops at both field strengths traversed the same counter‐clockwise direction, with increased loop areas reflecting increased susceptibility effects at 7 T. Simulations confirmed the higher sensitivity of gradient‐echo and the higher specificity of spin‐echo to the microvasculature, with peak spin‐echo specificity moving from 3 μm at 3 T towards 1.5 μm at 7 T. This study confirmed the feasibility of using SAGE‐DSC at 7 T for microvascular characterization. rCBV and VSI maps show similar behavior while allowing for reduced contrast agent dosage and improved resolution. The spin‐echo specificity shifted towards smaller vessel radii for increasing field strengths. These findings form the basis for exploration and validation in larger patient populations.
- 2 September 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (10) , e70380
Open AccessFeasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla
Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular characterization at 3 T. Higher field strength MRI offers increased contrast, resolution and signal‐to‐noise ratio, providing potential to improve microvascular characterization. This feasibility study aimed to implement a protocol for SAGE‐DSC at 7 T and study its potential for microvascular characterization. SAGE‐DSC was acquired in eight patients undergoing treatment for glioma (four females, median age 57 years) at 3 and 7 T. Data were analyzed using the temporal signal‐to‐noise ratio (tSNR) and contrast‐to‐noise ratio (CNR) and by comparing perfusion maps, VSI and vascular architectural imaging (VAI). Simulations were performed to study the relationship between vessel size and for SAGE‐DSC at 3 and 7 T. Contrast agent dosage could be reduced while maintaining higher CNR at 7 T (but lower tSNR). Assessment by an experienced neuroradiologist showed similar rCBV map quality at 3 and 7 T. VSI maps showed the same normal‐appearing gray‐to‐white matter ratios while in‐plane resolution improved at least 52% at 7 T. VAI hysteresis loops at both field strengths traversed the same counter‐clockwise direction, with increased loop areas reflecting increased susceptibility effects at 7 T. Simulations confirmed the higher sensitivity of gradient‐echo and the higher specificity of spin‐echo to the microvasculature, with peak spin‐echo specificity moving from 3 μm at 3 T towards 1.5 μm at 7 T. This study confirmed the feasibility of using SAGE‐DSC at 7 T for microvascular characterization. rCBV and VSI maps show similar behavior while allowing for reduced contrast agent dosage and improved resolution. The spin‐echo specificity shifted towards smaller vessel radii for increasing field strengths. These findings form the basis for exploration and validation in larger patient populations.
- 10 October 2025
- Published by Springer Nature
- p. 22-31
OccluNet: Spatio-Temporal Deep Learning for Occlusion Detection on DSA
- 10 October 2025
- Published by Springer Nature
- p. 22-31
OccluNet: Spatio-Temporal Deep Learning for Occlusion Detection on DSA
- Open Access
OccluNet: Spatio-Temporal Deep Learning for Occlusion Detection on DSA
Accurate detection of vascular occlusions during endovascular thrombectomy (EVT) is critical in acute ischemic stroke (AIS). Interpretation of digital subtraction angiography (DSA) sequences poses challenges due to anatomical complexity and time constraints. This work proposes OccluNet, a spatio-temporal deep learning model that integrates YOLOX, a single-stage object detector, with transformer-based temporal attention mechanisms to automate occlusion detection in DSA sequences. We compared OccluNet with a YOLOv11 baseline trained on either individual DSA frames or minimum intensity projections. Two spatio-temporal variants were explored for OccluNet: pure temporal attention and divided space-time attention. Evaluation on DSA images from the MR CLEAN Registry revealed the model's capability to capture temporally consistent features, achieving precision and recall of 89.02% and 74.87%, respectively. OccluNet significantly outperformed the baseline models, and both attention variants attained similar performance. Source code is available at https://github.com/anushka-kore/OccluNet.git
Open AccessOccluNet: Spatio-Temporal Deep Learning for Occlusion Detection on DSA
Accurate detection of vascular occlusions during endovascular thrombectomy (EVT) is critical in acute ischemic stroke (AIS). Interpretation of digital subtraction angiography (DSA) sequences poses challenges due to anatomical complexity and time constraints. This work proposes OccluNet, a spatio-temporal deep learning model that integrates YOLOX, a single-stage object detector, with transformer-based temporal attention mechanisms to automate occlusion detection in DSA sequences. We compared OccluNet with a YOLOv11 baseline trained on either individual DSA frames or minimum intensity projections. Two spatio-temporal variants were explored for OccluNet: pure temporal attention and divided space-time attention. Evaluation on DSA images from the MR CLEAN Registry revealed the model's capability to capture temporally consistent features, achieving precision and recall of 89.02% and 74.87%, respectively. OccluNet significantly outperformed the baseline models, and both attention variants attained similar performance. Source code is available at https://github.com/anushka-kore/OccluNet.git
- Open Access
- 2 December 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (5) , 2076-2087
Mitigating undersampling errors in MR fingerprinting by sequence optimization
Purpose: To develop a method for MR Fingerprinting (MRF) sequence optimization that takes both the applied undersampling pattern and a realistic reference map into account.Methods: A predictive model for the undersampling error leveraging on perturbation theory was exploited to optimize the MRF flip angle sequence for improved robustness against undersampling artifacts. In this framework parameter maps from a previously acquired MRF scan were used as reference. Sequences were optimized for different sequence lengths, smoothness constraints and undersampling factors. Numerical simulations and in vivo measurements in eight healthy subjects were performed to assess the effect of the performed optimization. The optimized MRF sequences were compared to a conventionally shaped flip angle pattern and an optimized pattern based on the Cramér–Rao lower bound (CRB).Results: Numerical simulations and in vivo results demonstrate that the undersampling errors can be suppressed by flip angle optimization. Analysis of the in vivo results show that a sequence optimized for improved robustness against undersampling with a flip angle train of length 400 yielded significantly lower median absolute errors in : and : compared to the conventional (: , : ) and CRB‐based (: , : ) sequences.Conclusion: The proposed method is able to optimize the MRF flip angle pattern such that significant mitigation of the artifacts from strong k‐space undersampling in MRF is achieved.
- 2 December 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (5) , 2076-2087
Open AccessMitigating undersampling errors in MR fingerprinting by sequence optimization
Purpose: To develop a method for MR Fingerprinting (MRF) sequence optimization that takes both the applied undersampling pattern and a realistic reference map into account.Methods: A predictive model for the undersampling error leveraging on perturbation theory was exploited to optimize the MRF flip angle sequence for improved robustness against undersampling artifacts. In this framework parameter maps from a previously acquired MRF scan were used as reference. Sequences were optimized for different sequence lengths, smoothness constraints and undersampling factors. Numerical simulations and in vivo measurements in eight healthy subjects were performed to assess the effect of the performed optimization. The optimized MRF sequences were compared to a conventionally shaped flip angle pattern and an optimized pattern based on the Cramér–Rao lower bound (CRB).Results: Numerical simulations and in vivo results demonstrate that the undersampling errors can be suppressed by flip angle optimization. Analysis of the in vivo results show that a sequence optimized for improved robustness against undersampling with a flip angle train of length 400 yielded significantly lower median absolute errors in : and : compared to the conventional (: , : ) and CRB‐based (: , : ) sequences.Conclusion: The proposed method is able to optimize the MRF flip angle pattern such that significant mitigation of the artifacts from strong k‐space undersampling in MRF is achieved.
- Open Access
- 1 November 2020
- Published by Elsevier in NeuroImage
- Vol. 222, 117227
Sharpness in motion corrected quantitative imaging at 7T
- 1 November 2020
- Published by Elsevier in NeuroImage
- Vol. 222, 117227
Open AccessSharpness in motion corrected quantitative imaging at 7T
- Open Access
- 1 October 2020
- Published by Elsevier in NeuroImage
- Vol. 219, 117014
Myelin water imaging from multi-echo MR relaxometry data using a joint sparsity constraint- 1 October 2020
- Published by Elsevier in NeuroImage
- Vol. 219, 117014
Open AccessMyelin water imaging from multi-echo MR relaxometry data using a joint sparsity constraint - 21 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (5) , 1681-1689
An Efficient Method for Multi-Parameter Mapping in Quantitative MRI Using B-Spline Interpolation
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching the measured signal with a precomputed signal dictionary on a discrete parameter grid (i.e. lookup table) as used in MR Fingerprinting. However, accurate estimation requires discretizing each parameter with a high resolution and consequently high computational and memory costs for dictionary generation, storage, and matching. Here, we reduce the required parameter resolution by approximating the signal between grid points through B-spline interpolation. The interpolant and its gradient are evaluated efficiently which enables a least-squares fitting method for parameter mapping. The resolution of each parameter was minimized while obtaining a user-specified interpolation accuracy. The method was evaluated by phantom and in-vivo experiments using fully-sampled and undersampled unbalanced (FISP) MR fingerprinting acquisitions. Bloch simulations incorporated relaxation effects (T1,T2), proton density (PD), receiver phase (φ0), transmit field inhomogeneity (B1+), and slice profile. Parameter maps were compared with those obtained from dictionary matching, where the parameter resolution was.
- 21 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (5) , 1681-1689
An Efficient Method for Multi-Parameter Mapping in Quantitative MRI Using B-Spline Interpolation
Quantitative MRI methods that estimate multiple physical parameters simultaneously often require the fitting of a computational complex signal model defined through the Bloch equations. Repeated Bloch simulations can be avoided by matching the measured signal with a precomputed signal dictionary on a discrete parameter grid (i.e. lookup table) as used in MR Fingerprinting. However, accurate estimation requires discretizing each parameter with a high resolution and consequently high computational and memory costs for dictionary generation, storage, and matching. Here, we reduce the required parameter resolution by approximating the signal between grid points through B-spline interpolation. The interpolant and its gradient are evaluated efficiently which enables a least-squares fitting method for parameter mapping. The resolution of each parameter was minimized while obtaining a user-specified interpolation accuracy. The method was evaluated by phantom and in-vivo experiments using fully-sampled and undersampled unbalanced (FISP) MR fingerprinting acquisitions. Bloch simulations incorporated relaxation effects (T1,T2), proton density (PD), receiver phase (φ0), transmit field inhomogeneity (B1+), and slice profile. Parameter maps were compared with those obtained from dictionary matching, where the parameter resolution was.
- Open Access
- 15 August 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0220835
A pharmacokinetic model including arrival time for two inputs and compensating for varying applied flip-angle in dynamic gadoxetic acid-enhanced MR imaging
Pharmacokinetic models facilitate assessment of properties of the micro-vascularization based on DCE-MRI data. However, accurate pharmacokinetic modeling in the liver is challenging since it has two vascular inputs and it is subject to large deformation and displacement due to respiration. We propose an improved pharmacokinetic model for the liver that (1) analytically models the arrival-time of the contrast agent for both inputs separately; (2) implicitly compensates for signal fluctuations that can be modeled by varying applied flip-angle e.g. due to B1-inhomogeneity. Orton’s AIF model is used to analytically represent the vascular input functions. The inputs are independently embedded into the Sourbron model. B1-inhomogeneity-driven variations of flip-angles are accounted for to justify the voxel’s displacement with respect to a pre-contrast image. The new model was shown to yield lower root mean square error (RMSE) after fitting the model to all but a minority of voxels compared to Sourbron’s approach. Furthermore, it outperformed this existing model in the majority of voxels according to three model-selection criteria. Our work primarily targeted to improve pharmacokinetic modeling for DCE-MRI of the liver. However, other types of pharmacokinetic models may also benefit from our approaches, since the techniques are generally applicable.
- 15 August 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (8) , e0220835
Open AccessA pharmacokinetic model including arrival time for two inputs and compensating for varying applied flip-angle in dynamic gadoxetic acid-enhanced MR imaging
Pharmacokinetic models facilitate assessment of properties of the micro-vascularization based on DCE-MRI data. However, accurate pharmacokinetic modeling in the liver is challenging since it has two vascular inputs and it is subject to large deformation and displacement due to respiration. We propose an improved pharmacokinetic model for the liver that (1) analytically models the arrival-time of the contrast agent for both inputs separately; (2) implicitly compensates for signal fluctuations that can be modeled by varying applied flip-angle e.g. due to B1-inhomogeneity. Orton’s AIF model is used to analytically represent the vascular input functions. The inputs are independently embedded into the Sourbron model. B1-inhomogeneity-driven variations of flip-angles are accounted for to justify the voxel’s displacement with respect to a pre-contrast image. The new model was shown to yield lower root mean square error (RMSE) after fitting the model to all but a minority of voxels compared to Sourbron’s approach. Furthermore, it outperformed this existing model in the majority of voxels according to three model-selection criteria. Our work primarily targeted to improve pharmacokinetic modeling for DCE-MRI of the liver. However, other types of pharmacokinetic models may also benefit from our approaches, since the techniques are generally applicable.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (2) , 308-319
Orientation Prior and Consistent Model Selection Increase Sensitivity of Tract-Based Spatial Statistics in Crossing-Fiber Regions
The goal of this paper is to increase the statistical power of crossing-fiber statistics in voxelwise analyses of diffusion-weighted magnetic resonance imaging (DW-MRI) data. In the proposed framework a fiber orientation atlas and a model complexity atlas were used to fit the ball-and-sticks model to diffusion-weighted images of subjects in a prospective population-based cohort study. Reproducibility and sensitivity of the partial volume fractions in the ball-and-sticks model were analyzed using TBSS (tract-based spatial statistics), and were compared to a reference framework. The reproducibility was investigated on two scans of 30 subjects acquired with an interval of approximately three weeks by studying the intraclass correlation coefficient (ICC). The sensitivity to true biological effects was evaluated by studying the regression with age on 500 subjects between 65 and 90 years old. Compared to the reference framework, the ICC improved significantly when using the proposed framework. Higher t-statistics indicated that regression coefficients with age could be determined more precisely with the proposed framework, and more voxels correlated significantly with age. The application of a fiber orientation atlas and a model complexity atlas can significantly improve the reproducibility and sensitivity of crossing-fiber statistics in TBSS.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 39 (2) , 308-319
Orientation Prior and Consistent Model Selection Increase Sensitivity of Tract-Based Spatial Statistics in Crossing-Fiber Regions
The goal of this paper is to increase the statistical power of crossing-fiber statistics in voxelwise analyses of diffusion-weighted magnetic resonance imaging (DW-MRI) data. In the proposed framework a fiber orientation atlas and a model complexity atlas were used to fit the ball-and-sticks model to diffusion-weighted images of subjects in a prospective population-based cohort study. Reproducibility and sensitivity of the partial volume fractions in the ball-and-sticks model were analyzed using TBSS (tract-based spatial statistics), and were compared to a reference framework. The reproducibility was investigated on two scans of 30 subjects acquired with an interval of approximately three weeks by studying the intraclass correlation coefficient (ICC). The sensitivity to true biological effects was evaluated by studying the regression with age on 500 subjects between 65 and 90 years old. Compared to the reference framework, the ICC improved significantly when using the proposed framework. Higher t-statistics indicated that regression coefficients with age could be determined more precisely with the proposed framework, and more voxels correlated significantly with age. The application of a fiber orientation atlas and a model complexity atlas can significantly improve the reproducibility and sensitivity of crossing-fiber statistics in TBSS.
- Open Access
Three-Dimensional Registration of Freehand-Tracked Ultrasound to CT Images of the Talocrural Joint
A rigid surface–volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD’ arthroscopic accessibility, given the fact that 51% of the talar surface could be visualized.
Open AccessThree-Dimensional Registration of Freehand-Tracked Ultrasound to CT Images of the Talocrural Joint
A rigid surface–volume registration scheme is presented in this study to register computed tomography (CT) and free-hand tracked ultrasound (US) images of the talocrural joint. Prior to registration, bone surfaces expected to be visible in US are extracted from the CT volume and bone contours in 2D US data are enhanced based on monogenic signal representation of 2D US images. A 3D monogenic signal data is reconstructed from the 2D data using the position of the US probe recorded with an optical tracking system. When registering the surface extracted from the CT scan to the monogenic signal feature volume, six transformation parameters are estimated so as to optimize the sum of monogenic signal features over the transformed surface. The robustness of the registration algorithm was tested on a dataset collected from 12 cadaveric ankles. The proposed method was used in a clinical case study to investigate the potential of US imaging for pre-operative planning of arthroscopic access to talar (osteo)chondral defects (OCDs). The results suggest that registrations with a registration error of 2 mm and less is achievable, and US has the potential to be used in assessment of an OCD’ arthroscopic accessibility, given the fact that 51% of the talar surface could be visualized.