Minxin Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minxin Ye has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Zheng Li
The Chinese University of Hong Kong
4 shared publications - Philip Wai Yan Chiu
Division of Upper GI and Metabolic Surgery Department of Surgery The Chinese University of Hong Kong Shatin Hong Kong
3 shared publications - Weibing Li
School of Computer Science and Engineering, Sun Yat-sen University, Guangzhou, China
2 shared publications - Calvin Sze Hang Ng
Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital
1 shared publication Danny Tat Ming Chan
1 shared publication- Danny Tat Ming Chan
Department of Neurosurgery, Prince of Wales Hospital, Hong Kong
1 shared publication
Latest Publications
- Open Access
- 18 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (29) , eadx7335
Parallel writing of 5D optical data via shaped voxels
Multidimensional optical data storage is a critically needed technology in the digital era. To overcome the low data writing rate in the conventional systems, we present a parallel five-dimensional optical data writing method by projecting arrays of depth-resolved voxels of different shapes via a digital micromirror device and temporally focusing a femtosecond laser amplifier. This is more efficient than the conventional approach that serially creates birefringent voxels in glass (e.g., nanogratings or oblate nanopores) via scanning an ultrafast laser while varying its polarizations. We demonstrated parallel writing of 16 by 16 birefringent voxels with eight different slow-axis azimuths by controlling the shapes of the projected light spots. Next, we demonstrated five-layer parallel data writing with 100% readout accuracy and a 1.5-terabyte storage capacity per disc. With a high repetition rate femtosecond laser amplifier (e.g., 100 kilohertz), our method may achieve a theoretical writing speed of 7.5 megabytes per second, paving the way for high-speed, high-capacity optical data storage.
- 18 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (29) , eadx7335
Open AccessParallel writing of 5D optical data via shaped voxels
Multidimensional optical data storage is a critically needed technology in the digital era. To overcome the low data writing rate in the conventional systems, we present a parallel five-dimensional optical data writing method by projecting arrays of depth-resolved voxels of different shapes via a digital micromirror device and temporally focusing a femtosecond laser amplifier. This is more efficient than the conventional approach that serially creates birefringent voxels in glass (e.g., nanogratings or oblate nanopores) via scanning an ultrafast laser while varying its polarizations. We demonstrated parallel writing of 16 by 16 birefringent voxels with eight different slow-axis azimuths by controlling the shapes of the projected light spots. Next, we demonstrated five-layer parallel data writing with 100% readout accuracy and a 1.5-terabyte storage capacity per disc. With a high repetition rate femtosecond laser amplifier (e.g., 100 kilohertz), our method may achieve a theoretical writing speed of 7.5 megabytes per second, paving the way for high-speed, high-capacity optical data storage.
- 2 July 2022
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 103, 9-13
Measurement of aspiration pressure in cannula brain tumour biopsy and its correlation with ultrasonographic elastography
- 2 July 2022
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 103, 9-13
Measurement of aspiration pressure in cannula brain tumour biopsy and its correlation with ultrasonographic elastography
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (3) , 1531-1542
Kinematic Modeling and Visual Servo Control of a Soft-Bodied Magnetic Anchored and Guided Endoscope
In minimally invasive surgery (MIS), a number of instruments are inserted into the surgical cavity via the trocar(s), which makes the surgical site crowded and instruments tend to fence with each other. In addition, the motion of the endoscope is restricted by the trocar, which limits the field of view of the endoscope. To alleviate these problems, magnetic anchored and guided systems (MAGS) have been proposed. Conventional MAGS are built from rigid materials with small actuators and sensors. As a result, these MAGS tend to be heavy, complex, difficult to make and costly. In this work, we first present a soft-bodied MAGS endoscope weighing 13 grams, which is made by printable silicon rubber with embedded magnets and a camera module. The usage of soft 3D printable material significantly reduces the complexity of the MAGS endoscope. The soft-bodied MAGS endoscope can be anchored and steered by an external magnet controlled by a serial-link robot arm. The kinematic modeling of the soft-bodied MAGS endoscope is developed. Visual servo based automatic instruments tracking of the soft-bodied MAGS endoscope is achieved for the first time. Experimental results validate that the soft-bodied MAGS endoscope can guide surgical instruments, showing its high potentials in MIS.
- 6 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (3) , 1531-1542
Kinematic Modeling and Visual Servo Control of a Soft-Bodied Magnetic Anchored and Guided Endoscope
In minimally invasive surgery (MIS), a number of instruments are inserted into the surgical cavity via the trocar(s), which makes the surgical site crowded and instruments tend to fence with each other. In addition, the motion of the endoscope is restricted by the trocar, which limits the field of view of the endoscope. To alleviate these problems, magnetic anchored and guided systems (MAGS) have been proposed. Conventional MAGS are built from rigid materials with small actuators and sensors. As a result, these MAGS tend to be heavy, complex, difficult to make and costly. In this work, we first present a soft-bodied MAGS endoscope weighing 13 grams, which is made by printable silicon rubber with embedded magnets and a camera module. The usage of soft 3D printable material significantly reduces the complexity of the MAGS endoscope. The soft-bodied MAGS endoscope can be anchored and steered by an external magnet controlled by a serial-link robot arm. The kinematic modeling of the soft-bodied MAGS endoscope is developed. Visual servo based automatic instruments tracking of the soft-bodied MAGS endoscope is achieved for the first time. Experimental results validate that the soft-bodied MAGS endoscope can guide surgical instruments, showing its high potentials in MIS.
- 21 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 1405-1412
A Semi-Autonomous Stereotactic Brain Biopsy Robot With Enhanced Safety
In stereotactic brain biopsy, operating the needle accurately and taking the biopsy specimen safely are two major challenges for ensuring the success of the surgical procedure. Considering this fact, surgical robots offering high accuracy and precision have been developed for neurosurgery including brain biopsy. Typical brain biopsy robots are only commanded to adjust the needle's pose before inserting the needle manually by a neurosurgeon. In the literature, there exists no robotic system that is competent to complete the needle insertion task autonomously. To move a step forward, a novel biopsy module for brain biopsy is first designed and fabricated in this paper. The biopsy module can be automated to complete a series of tasks such as inserting the needle, generating and controlling the aspiration pressure for specimen acquisition, and rotating the cannula for side-cutting. The biopsy module is further integrated with a cost-effective and lightweight UR5 robot and an optical tracking system to improve the autonomy, leading to a stereotactic neuronavigation system. Kinematic relationships of the involved elements are established via a calibration process. A quadratic programming based approach equipped with a virtual potential field method is implemented to safely control the robot with joint-limit avoidance and obstacle avoidance capabilities. The experimentation of the brain biopsy robot is performed, demonstrating that the developed robotic system has potential applicability in the brain biopsy surgery.
- 21 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 1405-1412
A Semi-Autonomous Stereotactic Brain Biopsy Robot With Enhanced Safety
In stereotactic brain biopsy, operating the needle accurately and taking the biopsy specimen safely are two major challenges for ensuring the success of the surgical procedure. Considering this fact, surgical robots offering high accuracy and precision have been developed for neurosurgery including brain biopsy. Typical brain biopsy robots are only commanded to adjust the needle's pose before inserting the needle manually by a neurosurgeon. In the literature, there exists no robotic system that is competent to complete the needle insertion task autonomously. To move a step forward, a novel biopsy module for brain biopsy is first designed and fabricated in this paper. The biopsy module can be automated to complete a series of tasks such as inserting the needle, generating and controlling the aspiration pressure for specimen acquisition, and rotating the cannula for side-cutting. The biopsy module is further integrated with a cost-effective and lightweight UR5 robot and an optical tracking system to improve the autonomy, leading to a stereotactic neuronavigation system. Kinematic relationships of the involved elements are established via a calibration process. A quadratic programming based approach equipped with a virtual potential field method is implemented to safely control the robot with joint-limit avoidance and obstacle avoidance capabilities. The experimentation of the brain biopsy robot is performed, demonstrating that the developed robotic system has potential applicability in the brain biopsy surgery.
- 25 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 4 (3) , 3106-3112
Shared Autonomy of a Flexible Manipulator in Constrained Endoluminal Surgical Tasks
Automation in surgery is becoming more and more active in recent years. From the editorial of Science Robotics in 2017, there are six levels of autonomy and the existing tele-operation lies in level 0 (no autonomy). Although full autonomy would be fictional in the current moment, task/shared autonomy would be highly achievable. In endoluminal surgeries, surgeons rely on manual operation of flexible instruments for tissue manipulation and dissection. The techniques are difficult to learn, which makes them a good candidate for automation. In this paper, we introduce our work on shared autonomy of a flexible manipulator in simulated constrained endoluminal tasks, e.g. tissue dissection task in transanal total mesorectal excision (TaTME) and endoscopic submucosal dissection (ESD) operations. During the procedure, the operator defines the dissection trajectory with a Novint Falcon device by marking via points. The dissection trajectory is dynamically planned based on the feedback from stereo endoscope system with consideration of the deformation of material. Furthermore, trajectory of the flexible manipulator is controlled by an adaptive controller with consideration of the possible collision between instruments and surrounding environment. This framework is validated by a mock up test with a 3 DOF flexible manipulator.
- 25 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 4 (3) , 3106-3112
Shared Autonomy of a Flexible Manipulator in Constrained Endoluminal Surgical Tasks
Automation in surgery is becoming more and more active in recent years. From the editorial of Science Robotics in 2017, there are six levels of autonomy and the existing tele-operation lies in level 0 (no autonomy). Although full autonomy would be fictional in the current moment, task/shared autonomy would be highly achievable. In endoluminal surgeries, surgeons rely on manual operation of flexible instruments for tissue manipulation and dissection. The techniques are difficult to learn, which makes them a good candidate for automation. In this paper, we introduce our work on shared autonomy of a flexible manipulator in simulated constrained endoluminal tasks, e.g. tissue dissection task in transanal total mesorectal excision (TaTME) and endoscopic submucosal dissection (ESD) operations. During the procedure, the operator defines the dissection trajectory with a Novint Falcon device by marking via points. The dissection trajectory is dynamically planned based on the feedback from stereo endoscope system with consideration of the deformation of material. Furthermore, trajectory of the flexible manipulator is controlled by an adaptive controller with consideration of the possible collision between instruments and surrounding environment. This framework is validated by a mock up test with a 3 DOF flexible manipulator.