Takayuki Kanai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takayuki Kanai has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Hikaru Souda
Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
3 shared publications- Noriyuki Kadoya
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan
3 shared publications - Haruo Matsushita
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan
2 shared publications Hongbo Chai
Department of Heavy Particle Medical Science, Yamagata University Graduate School of Medical Science, Yamagata, Japan
2 shared publications- Kazuma Kishi
Department of Respiratory Medicine, Toho University Omori Medical Center, Tokyo, Japan
2 shared publications - Keiichi Jingu
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan
2 shared publications
Latest Publications
- Open Access
- 14 January 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (1) , 134-147
A national survey of the clinical practice of surface-guided radiation therapy in Japan
The purpose of this study was to evaluate the diffusion of surface-guided radiation therapy (SGRT), implementation of quality control and quality assurance strategies, established clinical workflows and user perceptions regarding the benefits and limitations of SGRT in routine practice. From October to December 2024, we surveyed 880 radiotherapy institutions in Japan regarding institutional characteristics, quality assurance/quality control, computed tomography simulation, treatment procedures and general questions regarding SGRT. The survey was distributed via mailing list and through vendors, and administered via Google Forms. A total of 292 institutions responded, corresponding to a response rate of 33%. Ninety-eight institutions reported introducing SGRT, and 50 institutions had introduced it after 2022. The highest usage rate of SGRT in breast treatment was 87%. Approximately half of the institutions performed daily checks of SGRT and radiation isocenter coincidence, as well as static accuracy, whereas 6% did not perform these checks at all. The primary functions of the SGRT system were patient positioning (94%), respiratory management (78%), patient monitoring (76%) and skin marker–less techniques (69%). Many institutions reduced or eliminated skin marking, citing simplified workflows and reduced setup time. Many respondents observed that SGRT implementation reduced both setup and treatment times for breast/chest, abdomen/pelvis and extremity procedures. SGRT has been widely embraced in Japan, offering notable clinical and workflow benefits. However, because participation in this survey was voluntary, the results may overrepresent institutions with greater awareness or adoption of SGRT. Greater standardization, broader insurance coverage and ongoing technological advancements are essential to fully realize its advantages.
- 14 January 2026
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (1) , 134-147
Open AccessA national survey of the clinical practice of surface-guided radiation therapy in Japan
The purpose of this study was to evaluate the diffusion of surface-guided radiation therapy (SGRT), implementation of quality control and quality assurance strategies, established clinical workflows and user perceptions regarding the benefits and limitations of SGRT in routine practice. From October to December 2024, we surveyed 880 radiotherapy institutions in Japan regarding institutional characteristics, quality assurance/quality control, computed tomography simulation, treatment procedures and general questions regarding SGRT. The survey was distributed via mailing list and through vendors, and administered via Google Forms. A total of 292 institutions responded, corresponding to a response rate of 33%. Ninety-eight institutions reported introducing SGRT, and 50 institutions had introduced it after 2022. The highest usage rate of SGRT in breast treatment was 87%. Approximately half of the institutions performed daily checks of SGRT and radiation isocenter coincidence, as well as static accuracy, whereas 6% did not perform these checks at all. The primary functions of the SGRT system were patient positioning (94%), respiratory management (78%), patient monitoring (76%) and skin marker–less techniques (69%). Many institutions reduced or eliminated skin marking, citing simplified workflows and reduced setup time. Many respondents observed that SGRT implementation reduced both setup and treatment times for breast/chest, abdomen/pelvis and extremity procedures. SGRT has been widely embraced in Japan, offering notable clinical and workflow benefits. However, because participation in this survey was voluntary, the results may overrepresent institutions with greater awareness or adoption of SGRT. Greater standardization, broader insurance coverage and ongoing technological advancements are essential to fully realize its advantages.
- Open Access
- 25 April 2024
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 11, 100011
Commissioning and Validation of CT Number to SPR Calibration in Carbon Ion Therapy Facility
- 25 April 2024
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 11, 100011
Open AccessCommissioning and Validation of CT Number to SPR Calibration in Carbon Ion Therapy Facility
- 30 August 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (4) , 367-378
Development of a quantitative analysis method for assessing patient body surface deformation using an optical surface tracking system
This study aimed to develop a new method to quantitatively analyze body shape changes in patients during radiotherapy without additional radiation exposure using an optical surface tracking system. This method’s accuracy was evaluated using a cubic phantom with a known shift. Surface images of three-dimensionally printed phantoms, which simulated the head and neck shapes of real patients before and after treatment, were used to create a deformation surface area histogram. The near-maximum deformation value covering an area of 2 cm2 in the surface image (Def-2cm2) was calculated. A volumetric modulated arc therapy (VMAT) plan was also created on the pre-treatment phantom, and the dose distribution was recalculated on the post-treatment phantom to compare the dose indices. Surface images of four patients were analyzed to evaluate Def-2cm2 and examine whether this method can be used in clinical cases. Experiments with the cubic phantom resulted in a mean deformation error of 0.08 mm. With head and neck phantoms, the Def-2cm2 value was 17.5 mm, and the dose that covered 95% of the planning target volume in the VMAT plan decreased by 11.7%, indicating that deformation of the body surface may affect the dose distribution. Although analysis of the clinical data showed no clinically relevant deformation in any of the cases, slight skin sagging and respiratory changes in the body surface were observed. The proposed method can quantitatively and accurately evaluate the deformation of a body surface. This method is expected to be used to make decisions regarding modifications to treatment plans.
- 30 August 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (4) , 367-378
Development of a quantitative analysis method for assessing patient body surface deformation using an optical surface tracking system
This study aimed to develop a new method to quantitatively analyze body shape changes in patients during radiotherapy without additional radiation exposure using an optical surface tracking system. This method’s accuracy was evaluated using a cubic phantom with a known shift. Surface images of three-dimensionally printed phantoms, which simulated the head and neck shapes of real patients before and after treatment, were used to create a deformation surface area histogram. The near-maximum deformation value covering an area of 2 cm2 in the surface image (Def-2cm2) was calculated. A volumetric modulated arc therapy (VMAT) plan was also created on the pre-treatment phantom, and the dose distribution was recalculated on the post-treatment phantom to compare the dose indices. Surface images of four patients were analyzed to evaluate Def-2cm2 and examine whether this method can be used in clinical cases. Experiments with the cubic phantom resulted in a mean deformation error of 0.08 mm. With head and neck phantoms, the Def-2cm2 value was 17.5 mm, and the dose that covered 95% of the planning target volume in the VMAT plan decreased by 11.7%, indicating that deformation of the body surface may affect the dose distribution. Although analysis of the clinical data showed no clinically relevant deformation in any of the cases, slight skin sagging and respiratory changes in the body surface were observed. The proposed method can quantitatively and accurately evaluate the deformation of a body surface. This method is expected to be used to make decisions regarding modifications to treatment plans.
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Design and Magnetic Field Measurement of the Superconducting Magnets for the Next-Generation Rotating Gantry
This paper describes the design and reports the test results of the world's most compact rotating gantry for a heavy-ion therapy system mounted with superconducting bending and focusing magnets. A rotating gantry is cylindrical irradiation equipment with magnets for beam transport and beam scanning that delivers energetic carbon ions at up to 430 MeV/u precisely to a tumor from any direction without changing the posture of the patient. However, because of the high magnetic rigidity of therapeutic carbon ions, the rotating gantry was too big to be installed at general hospitals. Therefore, the superconducting rotating gantry had been developed in collaboration with Yamagata University. In the project, to achieve further downsizing of the rotating gantry, the length of the scanning irradiation system is reduced and the magnetic field of the superconducting magnet is increased to 3.5 T from the 2.88 T of the first superconducting gantry installed in the National Institutes for Quantum and Radiological Science and Technology (QST). As a result, the gantry is downsized to 2/3 of the first superconducting rotating gantry. This next-generation small superconducting rotating gantry has already been installed and is undergoing preclinical commissioning at Yamagata University.
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Design and Magnetic Field Measurement of the Superconducting Magnets for the Next-Generation Rotating Gantry
This paper describes the design and reports the test results of the world's most compact rotating gantry for a heavy-ion therapy system mounted with superconducting bending and focusing magnets. A rotating gantry is cylindrical irradiation equipment with magnets for beam transport and beam scanning that delivers energetic carbon ions at up to 430 MeV/u precisely to a tumor from any direction without changing the posture of the patient. However, because of the high magnetic rigidity of therapeutic carbon ions, the rotating gantry was too big to be installed at general hospitals. Therefore, the superconducting rotating gantry had been developed in collaboration with Yamagata University. In the project, to achieve further downsizing of the rotating gantry, the length of the scanning irradiation system is reduced and the magnetic field of the superconducting magnet is increased to 3.5 T from the 2.88 T of the first superconducting gantry installed in the National Institutes for Quantum and Radiological Science and Technology (QST). As a result, the gantry is downsized to 2/3 of the first superconducting rotating gantry. This next-generation small superconducting rotating gantry has already been installed and is undergoing preclinical commissioning at Yamagata University.
- Open Access
- 23 June 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (4) , 743
Corrigendum to: Prediction of the minimum spacer thickness required for definitive radiotherapy with carbon ions and photons for pelvic tumors: an in silico planning study using virtual spacers
When this paper first published online, the author name Rei Mastueda was incorrect. It should have been Rei Matsueda. This has now been corrected online.
- 23 June 2021
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 62 (4) , 743
Open AccessCorrigendum to: Prediction of the minimum spacer thickness required for definitive radiotherapy with carbon ions and photons for pelvic tumors: an in silico planning study using virtual spacers
When this paper first published online, the author name Rei Mastueda was incorrect. It should have been Rei Matsueda. This has now been corrected online.
- 1 January 2020
- Published by Elsevier in Medical Dosimetry
- Vol. 45 (3) , 206-212
Evaluation of the effect of user-guided deformable image registration of thoracic images on registration accuracy among users
- 1 January 2020
- Published by Elsevier in Medical Dosimetry
- Vol. 45 (3) , 206-212
Evaluation of the effect of user-guided deformable image registration of thoracic images on registration accuracy among users
- Open Access
- 21 November 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
In silico comparison of the dosimetric impacts of a greater omentum spacer for abdominal and pelvic tumors in carbon-ion, proton and photon radiotherapy
Purpose: The purpose of this study was to compare carbon-ion (C-ion), proton and photon radiotherapy (RT) plans with regard to dose reduction of the gastrointestinal (GI) tract by using a greater omentum spacer (GO spacer).Methods: We retrospectively retrieved data for ten patients who received the GO spacer as surgical spacer placement for abdominal and pelvic tumors. Simulation plans were created on pre-spacer Computed Tomography (CT) and post-spacer CT for C-ion RT, proton RT and photon RT to compare the dose of the GI tract. The plans were normalized so that at least 95% of the planning target volume (PTV) received 70 Gy (relative biological effectiveness equivalent) delivered in 35 fractions. All plans were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints for the PTV and spinal cord (maximum dose < 45 Gy). The part of the GI tract to be evaluated was defined as that most adjacent to the PTV. C-ion RT plans and proton RT plans were calculated by a spot scanning technique, and photon RT plans were calculated employing by fixed-field intensity-modulated radiation therapy.Results: D2 cc and V10–70 of the GI tract were significantly lower on post-spacer plans than on pre-spacer plans for all three RT modalities. Regarding post-spacer plans, D2 cc of the GI tract was significantly lower on C-ion RT plans and proton RT plans than on photon RT plans (C-ion vs photonp = 0.001, proton vs photonp = 0.002). However, there was no significant difference between C-ion RT plans and proton RT plans for D2 cc of the GI tract (C-ion vs protonp = 0.992). In the photon RT plan for one patient, D2 cc of the GI tract did not meet < 50 Gy.Conclusions: The GO spacer shows a significant dose reduction effect on the GI tract.
- 21 November 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-10
Open AccessIn silico comparison of the dosimetric impacts of a greater omentum spacer for abdominal and pelvic tumors in carbon-ion, proton and photon radiotherapy
Purpose: The purpose of this study was to compare carbon-ion (C-ion), proton and photon radiotherapy (RT) plans with regard to dose reduction of the gastrointestinal (GI) tract by using a greater omentum spacer (GO spacer).Methods: We retrospectively retrieved data for ten patients who received the GO spacer as surgical spacer placement for abdominal and pelvic tumors. Simulation plans were created on pre-spacer Computed Tomography (CT) and post-spacer CT for C-ion RT, proton RT and photon RT to compare the dose of the GI tract. The plans were normalized so that at least 95% of the planning target volume (PTV) received 70 Gy (relative biological effectiveness equivalent) delivered in 35 fractions. All plans were created with the lowest possible dose to the GI tract under conditions that meet the dose constraints for the PTV and spinal cord (maximum dose < 45 Gy). The part of the GI tract to be evaluated was defined as that most adjacent to the PTV. C-ion RT plans and proton RT plans were calculated by a spot scanning technique, and photon RT plans were calculated employing by fixed-field intensity-modulated radiation therapy.Results: D2 cc and V10–70 of the GI tract were significantly lower on post-spacer plans than on pre-spacer plans for all three RT modalities. Regarding post-spacer plans, D2 cc of the GI tract was significantly lower on C-ion RT plans and proton RT plans than on photon RT plans (C-ion vs photonp = 0.001, proton vs photonp = 0.002). However, there was no significant difference between C-ion RT plans and proton RT plans for D2 cc of the GI tract (C-ion vs protonp = 0.992). In the photon RT plan for one patient, D2 cc of the GI tract did not meet < 50 Gy.Conclusions: The GO spacer shows a significant dose reduction effect on the GI tract.
- 1 June 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119 (3) , 444-448
Evaluation of four-dimensional computed tomography (4D-CT)-based pulmonary ventilation: The high correlation between 4D-CT ventilation and 81mKr-planar images was found
- 1 June 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119 (3) , 444-448
Evaluation of four-dimensional computed tomography (4D-CT)-based pulmonary ventilation: The high correlation between 4D-CT ventilation and 81mKr-planar images was found