Xiaodong Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaodong Hu has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Jing Liu
College of Computer Science, South-Central Minzu University, Wuhan 430074, China
5 shared publications - Jing Zou
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
5 shared publications - Sen Wu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
5 shared publications - Enxiu Wu
State Key Laboratory of Precision Measurement Technology and Instruments, School of Precision Instruments and Opto-electronics Engineering, Tianjin University, Tianjin, China
4 shared publications Xiaotang Hu
State Key Laboratory of Precision Measurement Technology & Instruments, Tianjin University, Tianjin 300072, China
4 shared publicationsYanan Zeng
4 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by Elsevier in SSRN Electronic Journal
Trace Solute Quantification via Optimal Quality Phase Difference Method with Refractive Index Mixing Rule Validation
Precisely quantifying a trace solute in a binary liquid mixture is challenging because its signal is masked by a dominant background component. Refractive index (RI) is sensitive to solution composition, and mixing rules can convert RI into solute concentration. Previous studies established mixing rules using RI data with 10⁻⁴ refractive index unit (RIU) resolution. Here we revisit them using a higher-resolution method. By introducing an optimal quality region search strategy, we developed the optimal quality phase difference method (OQPDM) based on digital holography, which achieves a resolution on the order of 10⁻⁶ RIU. Using this method, we systematically evaluated mixing rules for binary solutions. The mole-fraction-weighted Lorentz–Lorenz model showed the best agreement with experimental data. By combining this model with OQPDM, we quantified trace solutes from phase measurements. The method was tested on MgCl₂ and CaCl₂ in concentrated NaCl solutions. The detection limit of OQPDM is 50 mg/L, which is a twofold improvement over the 100 mg/L limit of a standard Abbe refractometer. OQPDM is label-free, non-invasive, and operates in real time. It offers a promising tool for in-situ composition monitoring in process applications.
- 13 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTrace Solute Quantification via Optimal Quality Phase Difference Method with Refractive Index Mixing Rule Validation
Precisely quantifying a trace solute in a binary liquid mixture is challenging because its signal is masked by a dominant background component. Refractive index (RI) is sensitive to solution composition, and mixing rules can convert RI into solute concentration. Previous studies established mixing rules using RI data with 10⁻⁴ refractive index unit (RIU) resolution. Here we revisit them using a higher-resolution method. By introducing an optimal quality region search strategy, we developed the optimal quality phase difference method (OQPDM) based on digital holography, which achieves a resolution on the order of 10⁻⁶ RIU. Using this method, we systematically evaluated mixing rules for binary solutions. The mole-fraction-weighted Lorentz–Lorenz model showed the best agreement with experimental data. By combining this model with OQPDM, we quantified trace solutes from phase measurements. The method was tested on MgCl₂ and CaCl₂ in concentrated NaCl solutions. The detection limit of OQPDM is 50 mg/L, which is a twofold improvement over the 100 mg/L limit of a standard Abbe refractometer. OQPDM is label-free, non-invasive, and operates in real time. It offers a promising tool for in-situ composition monitoring in process applications.
- Open Access
- 26 September 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Simultaneous measurements of microplastic 3D morphology and naphthalene adsorption based on digital holographic microscopy
The accumulation of microplastics (MPs) in the body through biological cycles leads to persistent health risks owing to their degradation resistance. Enhanced toxicity arises from co-occurrence with polycyclic aromatic hydrocarbons (PAHs) that adsorb onto MPs in aquatic environments. Elucidation of MP-PAH adsorption mechanisms requires precise, simultaneous, in situ measurements of two critical parameters, i.e., the dynamic morphologies of MP particles and PAH concentrations. However, there is no comprehensive technology available that can simultaneously measure changes in both of these physical and chemical parameters. This report describes a digital holographic microscopy-based method for simultaneously measuring the 3D MP morphologies and PAH concentration changes in real time. A simple digital off-axis holographic microscopic system is used in combination with a phase difference method to measure the refractive index of the solution to determine the PAH concentration. The measurement results of the phase difference method are consistent with those obtained using a fluorescence spectrophotometer, and the signal-to-noise ratio is 38% higher. The developed technique enables real-time measurements of the PAH concentration changes to derive their adsorption kinetics, thermodynamics, and isothermal models, as verified by adsorption experiments involving various MPs in naphthalene solutions. This work presents a simple and purely optical method for simultaneous physical-chemical characterization in aqueous solutions, thus advancing measurement capabilities for analyzing environmental interfacial processes. The proposed methodology demonstrates broad applicability for co-monitoring morphological and chemical parameters in liquid-phase systems, which expands the scope of optical measurement techniques in biological and environmental sciences.
- 26 September 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessSimultaneous measurements of microplastic 3D morphology and naphthalene adsorption based on digital holographic microscopy
The accumulation of microplastics (MPs) in the body through biological cycles leads to persistent health risks owing to their degradation resistance. Enhanced toxicity arises from co-occurrence with polycyclic aromatic hydrocarbons (PAHs) that adsorb onto MPs in aquatic environments. Elucidation of MP-PAH adsorption mechanisms requires precise, simultaneous, in situ measurements of two critical parameters, i.e., the dynamic morphologies of MP particles and PAH concentrations. However, there is no comprehensive technology available that can simultaneously measure changes in both of these physical and chemical parameters. This report describes a digital holographic microscopy-based method for simultaneously measuring the 3D MP morphologies and PAH concentration changes in real time. A simple digital off-axis holographic microscopic system is used in combination with a phase difference method to measure the refractive index of the solution to determine the PAH concentration. The measurement results of the phase difference method are consistent with those obtained using a fluorescence spectrophotometer, and the signal-to-noise ratio is 38% higher. The developed technique enables real-time measurements of the PAH concentration changes to derive their adsorption kinetics, thermodynamics, and isothermal models, as verified by adsorption experiments involving various MPs in naphthalene solutions. This work presents a simple and purely optical method for simultaneous physical-chemical characterization in aqueous solutions, thus advancing measurement capabilities for analyzing environmental interfacial processes. The proposed methodology demonstrates broad applicability for co-monitoring morphological and chemical parameters in liquid-phase systems, which expands the scope of optical measurement techniques in biological and environmental sciences.
- Open Access
- 1 September 2025
- Published by Tsinghua University Press in Nano Research
- Vol. 18 (9)
Bias voltage-switchable metal-insulator transition in 2D van der Waals TMDs FETs: Role of tunneling barriers
Two-dimensional transition metal dichalcogenides (2D TMDs) with metal-insulator transition (MIT) has garnered significant attention for their potential in elucidating electronic state regulation mechanisms and advancing novel electronic devices, ultra-low power switches, and memory technologies. Generally, MIT behavior is often obscured by Schottky barrier (SB). Previous approaches, such as using four-probe methods or barrier-free van der Waals (vdW) semimetal electrodes, have aimed to eliminate the influence of SB on MIT. However, these methods are either complicated by intricate fabrication and testing processes or limited by the availability of suitable semimetal electrodes. Here, we demonstrate a bias voltage (Vds)-switchable MIT in pure vdW TMDs FETs for the first time, driven by Vds-tunable effective SB and charge injection mechanisms. We identify a convert voltage (Vconvert), which can be reduced by eliminating extra tunneling barriers introduced by vdW gaps before the inherent SB. This work offers comprehensive perspective on how tunneling barriers influences MIT and introduces a straightforward approach to fabricate MIT-based electronic devices.
- 1 September 2025
- Published by Tsinghua University Press in Nano Research
- Vol. 18 (9)
Open AccessBias voltage-switchable metal-insulator transition in 2D van der Waals TMDs FETs: Role of tunneling barriers
Two-dimensional transition metal dichalcogenides (2D TMDs) with metal-insulator transition (MIT) has garnered significant attention for their potential in elucidating electronic state regulation mechanisms and advancing novel electronic devices, ultra-low power switches, and memory technologies. Generally, MIT behavior is often obscured by Schottky barrier (SB). Previous approaches, such as using four-probe methods or barrier-free van der Waals (vdW) semimetal electrodes, have aimed to eliminate the influence of SB on MIT. However, these methods are either complicated by intricate fabrication and testing processes or limited by the availability of suitable semimetal electrodes. Here, we demonstrate a bias voltage (Vds)-switchable MIT in pure vdW TMDs FETs for the first time, driven by Vds-tunable effective SB and charge injection mechanisms. We identify a convert voltage (Vconvert), which can be reduced by eliminating extra tunneling barriers introduced by vdW gaps before the inherent SB. This work offers comprehensive perspective on how tunneling barriers influences MIT and introduces a straightforward approach to fabricate MIT-based electronic devices.
- Open Access
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 42733-42743
Study on the Fourier Defects of Cone-Beam Computed Laminography
Cone-beam computed laminography (CBCL) is widely used in non-destructive testing of plate-like samples due to flexible scanning geometry and fine image details. However, the Fourier domain defects lead to superimposed artifacts, which significantly degrade the image quality. This paper aims to assess the data distribution of CBCL projections in the Fourier domain, and to precisely delineate the Fourier defective volume. We derive the mapping scheme from CBCL projections to the Fourier domain using the Generalized Fourier Slice Theorem. Then, practical defect delineation methods are proposed for the cases of CBCL global scanning (i.e., non-truncated projections) and local scanning (i.e., truncated projections). Simulation experiments have been conducted to validate the proposed methods, indicating that the data incompleteness of CBCL is related not only to the scanning parameters but also to the shape and orientation of the object. Moreover, a de-artifacting algorithm based on Fourier priori information has been preliminarily implemented, which shows huge potential in efficiency and image quality over conventional SART-based algorithms.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 42733-42743
Open AccessStudy on the Fourier Defects of Cone-Beam Computed Laminography
Cone-beam computed laminography (CBCL) is widely used in non-destructive testing of plate-like samples due to flexible scanning geometry and fine image details. However, the Fourier domain defects lead to superimposed artifacts, which significantly degrade the image quality. This paper aims to assess the data distribution of CBCL projections in the Fourier domain, and to precisely delineate the Fourier defective volume. We derive the mapping scheme from CBCL projections to the Fourier domain using the Generalized Fourier Slice Theorem. Then, practical defect delineation methods are proposed for the cases of CBCL global scanning (i.e., non-truncated projections) and local scanning (i.e., truncated projections). Simulation experiments have been conducted to validate the proposed methods, indicating that the data incompleteness of CBCL is related not only to the scanning parameters but also to the shape and orientation of the object. Moreover, a de-artifacting algorithm based on Fourier priori information has been preliminarily implemented, which shows huge potential in efficiency and image quality over conventional SART-based algorithms.
- Open Access
Improving the Signal-to-Noise Ratio of Axial Displacement Measurements of Microspheres Based on Compound Digital Holography Microscopy Combined with the Reconstruction Centering Method
In 3D microsphere tracking, unlike in-plane motion that can be measured directly by a microscope, axial displacements are resolved by optical interference or a diffraction model. As a result, the axial results are affected by the environmental noise. The immunity to environmental noise increases with measurement accuracy and the signal-to-noise ratio (SNR). In compound digital holography microscopy (CDHM)-based measurements, precise identification of the tracking marker is critical to ensuring measurement precision. The reconstruction centering method (RCM) was proposed to suppress the drawbacks caused by installation errors and, at the same time, improve the correct identification of the tracking marker. The reconstructed center is considered to be the center of the microsphere, rather than the center of imaging in conventional digital holographic microscopy. This method was verified by simulation of rays tracing through microspheres and axial moving experiments. The axial displacements of silica microspheres with diameters of 5 μm and 10 μm were tested by CDHM in combination with the RCM. As a result, the SNR of the proposed method was improved by around 30%. In addition, the method was successfully applied to axial displacement measurements of overlapped microspheres with a resolution of 2 nm.
Open AccessImproving the Signal-to-Noise Ratio of Axial Displacement Measurements of Microspheres Based on Compound Digital Holography Microscopy Combined with the Reconstruction Centering Method
In 3D microsphere tracking, unlike in-plane motion that can be measured directly by a microscope, axial displacements are resolved by optical interference or a diffraction model. As a result, the axial results are affected by the environmental noise. The immunity to environmental noise increases with measurement accuracy and the signal-to-noise ratio (SNR). In compound digital holography microscopy (CDHM)-based measurements, precise identification of the tracking marker is critical to ensuring measurement precision. The reconstruction centering method (RCM) was proposed to suppress the drawbacks caused by installation errors and, at the same time, improve the correct identification of the tracking marker. The reconstructed center is considered to be the center of the microsphere, rather than the center of imaging in conventional digital holographic microscopy. This method was verified by simulation of rays tracing through microspheres and axial moving experiments. The axial displacements of silica microspheres with diameters of 5 μm and 10 μm were tested by CDHM in combination with the RCM. As a result, the SNR of the proposed method was improved by around 30%. In addition, the method was successfully applied to axial displacement measurements of overlapped microspheres with a resolution of 2 nm.
- Open Access
- 13 February 2022
- Published by MDPI AG in Mathematics
- Vol. 10 (4) , 579
A Generalized Construction Model for CT Projection-Wise Filters on the SDBP Technique
Nowadays, with the rapid development of computed tomography (CT), the theoretical expansion of CT reconstruction has become the crucial ingredient to break through technical bottlenecks. This article supplements relevant knowledge of the method for constructing CT projection-wise filters. From the perspective of the mathematical principle of CT reconstruction, the second-order divided-difference back projection (SDBP) technique is firstly proposed, which is an implementation of accurate and efficient inverse Radon transform. On the basis of the SDBP technique, a brand new computational model for filter expressions is derived. The model reveals the correlation between the convolution kernel for data restoration and the filter expression and also specifies the principle of filter construction. On the proposed filter construction model, the decomposition form of filters is discovered for the first time. A series of basic filters are acquired, which can be used to compose filters in actual need. According to the superposition principle, the properties of a filter depend on the decomposed basic filters. The selection of the kernel function on the properties of basic filters clarifies the general rule of filter construction. These theories proposed in this article are of reference value for the filter optimization research in the CT reconstruction field.
- 13 February 2022
- Published by MDPI AG in Mathematics
- Vol. 10 (4) , 579
Open AccessA Generalized Construction Model for CT Projection-Wise Filters on the SDBP Technique
Nowadays, with the rapid development of computed tomography (CT), the theoretical expansion of CT reconstruction has become the crucial ingredient to break through technical bottlenecks. This article supplements relevant knowledge of the method for constructing CT projection-wise filters. From the perspective of the mathematical principle of CT reconstruction, the second-order divided-difference back projection (SDBP) technique is firstly proposed, which is an implementation of accurate and efficient inverse Radon transform. On the basis of the SDBP technique, a brand new computational model for filter expressions is derived. The model reveals the correlation between the convolution kernel for data restoration and the filter expression and also specifies the principle of filter construction. On the proposed filter construction model, the decomposition form of filters is discovered for the first time. A series of basic filters are acquired, which can be used to compose filters in actual need. According to the superposition principle, the properties of a filter depend on the decomposed basic filters. The selection of the kernel function on the properties of basic filters clarifies the general rule of filter construction. These theories proposed in this article are of reference value for the filter optimization research in the CT reconstruction field.
- 1 February 2022
- Published by IOP Publishing in Nanotechnology
- Vol. 33 (17) , 175704
Dielectric engineering enable to lateral anti-ambipolar MoTe 2 heterojunction
Atomically two-dimensional (2D) materials have generated widespread interest for novel electronics and optoelectronics. Specially, owing to atomically thin 2D structure, the electronic bandgap of 2D semiconductors can be engineered by manipulating the surrounding dielectric environment. In this work, we develop an effective and controllable approach to manipulate dielectric properties of h-BN through gallium ions (Ga + ) implantation for the first time. And the maximum surface potential difference between the intrinsic h-BN (h-BN) and the Ga + implanted h-BN (Ga + -h-BN) is up to 1.3 V, which is characterized by Kelvin probe force microscopy. More importantly, the MoTe 2 transistor stacked on Ga + -h-BN exhibits p-type dominated transfer characteristic, while the MoTe 2 transistor stacked on the intrinsic h-BN behaves as n-type, which enable to construct MoTe 2 heterojunction through dielectric engineering of h-BN. The dielectric engineering also provides good spatial selectivity and allows to build MoTe 2 heterojunction based on a single MoTe 2 flake. The developed MoTe 2 heterojunction shows stable anti-ambipolar behaviour. Furthermore, we preliminarily implemented a ternary inverter based on anti-ambipolar MoTe 2 heterojunction. Ga + implantation assisted dielectric engineering provides an effective and generic approach to modulate electric bandgap for a wide variety of 2D materials. And the implementation of ternary inverter based on anti-ambipolar transistor could lead to new energy-efficient logical circuit and system designs in semiconductors.
- 1 February 2022
- Published by IOP Publishing in Nanotechnology
- Vol. 33 (17) , 175704
Dielectric engineering enable to lateral anti-ambipolar MoTe 2 heterojunction
Atomically two-dimensional (2D) materials have generated widespread interest for novel electronics and optoelectronics. Specially, owing to atomically thin 2D structure, the electronic bandgap of 2D semiconductors can be engineered by manipulating the surrounding dielectric environment. In this work, we develop an effective and controllable approach to manipulate dielectric properties of h-BN through gallium ions (Ga + ) implantation for the first time. And the maximum surface potential difference between the intrinsic h-BN (h-BN) and the Ga + implanted h-BN (Ga + -h-BN) is up to 1.3 V, which is characterized by Kelvin probe force microscopy. More importantly, the MoTe 2 transistor stacked on Ga + -h-BN exhibits p-type dominated transfer characteristic, while the MoTe 2 transistor stacked on the intrinsic h-BN behaves as n-type, which enable to construct MoTe 2 heterojunction through dielectric engineering of h-BN. The dielectric engineering also provides good spatial selectivity and allows to build MoTe 2 heterojunction based on a single MoTe 2 flake. The developed MoTe 2 heterojunction shows stable anti-ambipolar behaviour. Furthermore, we preliminarily implemented a ternary inverter based on anti-ambipolar MoTe 2 heterojunction. Ga + implantation assisted dielectric engineering provides an effective and generic approach to modulate electric bandgap for a wide variety of 2D materials. And the implementation of ternary inverter based on anti-ambipolar transistor could lead to new energy-efficient logical circuit and system designs in semiconductors.
- 24 February 2021
- Published by IOP Publishing in Applied Physics Express
- Vol. 14 (3) , 035004
Quantitative phase imaging of cells through turbid media based on infrared digital holographic microscopy
Most biological cells live in turbid media that poses an obstacle to real-time measurement of morphology, which is significant in the biomedical field. Imaging through turbid environments is experimentally challenging using visible-light illumination for multiple scattering. Therefore, an infrared digital holographic method is reported herein to test biological samples through turbid media that can achieve real-time three-dimensional morphology measurement. Pure milk is employed as turbid media with 500 μm maximum thickness. The correctness of phase reconstructed from the infrared system is proved compared to that of a visible-light system with less than a 10% deviation of phase difference.
- 24 February 2021
- Published by IOP Publishing in Applied Physics Express
- Vol. 14 (3) , 035004
Quantitative phase imaging of cells through turbid media based on infrared digital holographic microscopy
Most biological cells live in turbid media that poses an obstacle to real-time measurement of morphology, which is significant in the biomedical field. Imaging through turbid environments is experimentally challenging using visible-light illumination for multiple scattering. Therefore, an infrared digital holographic method is reported herein to test biological samples through turbid media that can achieve real-time three-dimensional morphology measurement. Pure milk is employed as turbid media with 500 μm maximum thickness. The correctness of phase reconstructed from the infrared system is proved compared to that of a visible-light system with less than a 10% deviation of phase difference.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (2) , 236-244
Dual-Energy Micro-CT Using GAGG:Ce and LYSO:Ce Scintillators
Dual-energy computed tomography has a better material determination capability than traditional CT. In this paper, we develop a dual-layer dual-energy micrometer computed tomography (DEMCT) imaging system with micrometer spatial resolution. The detector of the DEMCT system uses GAGG: Ce and LYSO: Ce scintillators to absorb x-rays of different energies, which is a new application of GAGG: Ce scintillator. As GAGG: Ce and LYSO: Ce have high light yields and their emission wavelengths match well to the quantum efficiency of common CCD, thicknesses of the scintillators are allowed to be thin, which is of great significance for high resolution imaging due to the limitation of the depth of field of objectives. We propose a mechanical adjustment method for registering high-energy and low-energy images, which saves the post-processing time and avoids oscillating or non-convergent iteration results of mathematical registration methods. Meanwhile, in order to increase the dual-energy spectra separation of materials detection in the DEMCT, a fast optimal kVp selection method is proposed. Results show that the DEMCT has the spatial resolution of 2 micrometers in low-energy imaging and 4 micrometers in high-energy imaging. In addition, materials of a silica mixture sample are clearly separated by the pixel selection of the energy map based on the DEMCT data. The proposed DEMCT system has the potential to separate materials that cannot be correctly determined on traditional CT.
- 31 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (2) , 236-244
Dual-Energy Micro-CT Using GAGG:Ce and LYSO:Ce Scintillators
Dual-energy computed tomography has a better material determination capability than traditional CT. In this paper, we develop a dual-layer dual-energy micrometer computed tomography (DEMCT) imaging system with micrometer spatial resolution. The detector of the DEMCT system uses GAGG: Ce and LYSO: Ce scintillators to absorb x-rays of different energies, which is a new application of GAGG: Ce scintillator. As GAGG: Ce and LYSO: Ce have high light yields and their emission wavelengths match well to the quantum efficiency of common CCD, thicknesses of the scintillators are allowed to be thin, which is of great significance for high resolution imaging due to the limitation of the depth of field of objectives. We propose a mechanical adjustment method for registering high-energy and low-energy images, which saves the post-processing time and avoids oscillating or non-convergent iteration results of mathematical registration methods. Meanwhile, in order to increase the dual-energy spectra separation of materials detection in the DEMCT, a fast optimal kVp selection method is proposed. Results show that the DEMCT has the spatial resolution of 2 micrometers in low-energy imaging and 4 micrometers in high-energy imaging. In addition, materials of a silica mixture sample are clearly separated by the pixel selection of the energy map based on the DEMCT data. The proposed DEMCT system has the potential to separate materials that cannot be correctly determined on traditional CT.
- 15 August 2020
- Published by Tsinghua University Press in Nano Research
- Vol. 13 (12) , 3445-3451
Non-volatile programmable homogeneous lateral MoTe2 junction for multi-bit flash memory and high-performance optoelectronics
Flash memories and semiconductor p-n junctions are two elementary but incompatible building blocks of most electronic and optoelectronic devices. The pressing demand to efficiently transfer massive data between memories and logic circuits, as well as for high data storage capability and device integration density, has fueled the rapid growth of technique and material innovations. Two-dimensional (2D) materials are considered as one of the most promising candidates to solve this challenge. However, a key aspect for 2D materials to build functional devices requires effective and accurate control of the carrier polarity, concentration and spatial distribution in the atomically thin structures. Here, a non-volatile opto-electrical doping approach is demonstrated, which enables reversibly writing spatially resolved doping patterns in the MoTe2 conductance channel through a MoTe2/hexagonal boron nitride (h-BN) heterostructure. Based on the doping effect induced by the combination of electrostatic modulation and ultraviolet light illumination, a 3-bit flash memory and various homojunctions on the same MoTe2/BN heterostructure are successfully developed. The flash memory achieved 8 well distinguished memory states with a maximum on/off ratio over 104. Each state showed negligible decay during the retention time of 2,400 s. The heterostructure also allowed the formation of p-p, n-n, p-n, and n-p homojunctions and the free transition among these states. The MoTe2 p-n homojunction with a rectification ratio of 103 exhibited excellent photodetection and photovoltaic performance. Having the memory device and p-n junction built on the same structure makes it possible to bring memory and computational circuit on the same chip, one step further to realize near-memory computing.
- 15 August 2020
- Published by Tsinghua University Press in Nano Research
- Vol. 13 (12) , 3445-3451
Non-volatile programmable homogeneous lateral MoTe2 junction for multi-bit flash memory and high-performance optoelectronics
Flash memories and semiconductor p-n junctions are two elementary but incompatible building blocks of most electronic and optoelectronic devices. The pressing demand to efficiently transfer massive data between memories and logic circuits, as well as for high data storage capability and device integration density, has fueled the rapid growth of technique and material innovations. Two-dimensional (2D) materials are considered as one of the most promising candidates to solve this challenge. However, a key aspect for 2D materials to build functional devices requires effective and accurate control of the carrier polarity, concentration and spatial distribution in the atomically thin structures. Here, a non-volatile opto-electrical doping approach is demonstrated, which enables reversibly writing spatially resolved doping patterns in the MoTe2 conductance channel through a MoTe2/hexagonal boron nitride (h-BN) heterostructure. Based on the doping effect induced by the combination of electrostatic modulation and ultraviolet light illumination, a 3-bit flash memory and various homojunctions on the same MoTe2/BN heterostructure are successfully developed. The flash memory achieved 8 well distinguished memory states with a maximum on/off ratio over 104. Each state showed negligible decay during the retention time of 2,400 s. The heterostructure also allowed the formation of p-p, n-n, p-n, and n-p homojunctions and the free transition among these states. The MoTe2 p-n homojunction with a rectification ratio of 103 exhibited excellent photodetection and photovoltaic performance. Having the memory device and p-n junction built on the same structure makes it possible to bring memory and computational circuit on the same chip, one step further to realize near-memory computing.