Somkid Pencharee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Somkid Pencharee has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Jaroon Jakmunee
Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
6 shared publications C. Bootjomchai
4 shared publications- Chanida Puangpila
Research Laboratory for Analytical Instrument and Electrochemistry Innovation, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
4 shared publications Jaroon Jakmunee
Research Laboratory for Analytical Instrument and Electrochemistry Innovation Department of Chemistry Faculty of Science Chiang Mai University Chiang Mai Thailand
4 shared publicationsR. Laopaiboon
4 shared publicationsJ. Laopaiboon
3 shared publications
Latest Publications
- 14 February 2026
- Published by Wiley in Chemnanomat
- Vol. 12 (2)
Portable Electrochemical Nitrite Detection in Processed Meat Using Functionalized Multiwalled Carbon Nanotubes‐Modified Screen‐Printed Carbon Electrodes
Nitrite, an active compound in sodium nitrite (NaNO 2 ) commonly used as a meat preservative, has been associated with various health risks upon overconsumption, highlighting the need for accurate detection techniques. This work presents the development of a portable and low‐cost electrochemical analytical device for nitrite detection, integrating a custom Arduino‐based potentiostat and a screen‐printed carbon electrode (SPCE) modified with functionalized multiwalled carbon nanotubes (f‐MWCNTs). The developed system is designed to be compact (~100 × 90 × 70 mm 3 ), cost‐effective (−1 , effectively covering the maximum residue limit of nitrite in processed meat. Additionally, the system exhibited a low limit of detection (LOD) and limit of quantification (LOQ) of 0.635 and 2.117 mg L −1 , respectively. Experimental examination of real processed meat samples confirmed the accuracy and reliability of the device, showing satisfactory agreement with the standard ion chromatography (IC) method. The results highlight the potential of this electrochemical approach as a superior alternative to conventional laboratory‐based methods, offering rapid, sensitive, and cost‐efficient nitrite monitoring in food safety applications.
- 14 February 2026
- Published by Wiley in Chemnanomat
- Vol. 12 (2)
Portable Electrochemical Nitrite Detection in Processed Meat Using Functionalized Multiwalled Carbon Nanotubes‐Modified Screen‐Printed Carbon Electrodes
Nitrite, an active compound in sodium nitrite (NaNO 2 ) commonly used as a meat preservative, has been associated with various health risks upon overconsumption, highlighting the need for accurate detection techniques. This work presents the development of a portable and low‐cost electrochemical analytical device for nitrite detection, integrating a custom Arduino‐based potentiostat and a screen‐printed carbon electrode (SPCE) modified with functionalized multiwalled carbon nanotubes (f‐MWCNTs). The developed system is designed to be compact (~100 × 90 × 70 mm 3 ), cost‐effective (−1 , effectively covering the maximum residue limit of nitrite in processed meat. Additionally, the system exhibited a low limit of detection (LOD) and limit of quantification (LOQ) of 0.635 and 2.117 mg L −1 , respectively. Experimental examination of real processed meat samples confirmed the accuracy and reliability of the device, showing satisfactory agreement with the standard ion chromatography (IC) method. The results highlight the potential of this electrochemical approach as a superior alternative to conventional laboratory‐based methods, offering rapid, sensitive, and cost‐efficient nitrite monitoring in food safety applications.
- 4 September 2023
- Published by Wiley in Journal of Cellular Biochemistry
- Vol. 124 (10) , 1546-1556
Development of lectin‐based lateral flow assay for fucosylated alpha‐fetoprotein
Fucosylated alpha‐fetoprotein (AFP‐L3) is a more specific and sensitive biomarker for early diagnosis of hepatocellular carcinoma (HCC) than only the alpha‐fetoprotein (AFP) level. Rapid and simple detection of AFP‐L3 level greatly facilitates the early detection as well as the treatment of HCC, resulting in the reduction of mortality. Here, we developed a rapid and sensitive lateral flow assay (LFA) using lectin Lens culinaris agglutinin (LCA), which has a specific affinity to AFP‐L3 fraction of AFP, as a biorecognition element for determination of the fucosylation of AFP. The assay is based on a sandwich format performed on a lateral flow test strip. LCA was immobilized on the membrane as a test line (T). Quantitative detection of AFP‐L3 was achieved by measuring the green color intensity of captured gold nanoparticle conjugates on the T and control line (C) utilizing an in‐house test strip reader. The calculated absorbance obtained by the green color intensity signals proportionally increased with AFP concentrations. The developed lectin‐based LFA provided a detection limit of 0.8 ng/mL for AFP with a linear range between 1.5 and 160.0 ng/mL within an assay time of 10 min. Recoveries between 74.5% and 113.2% with relative standard deviations of 5.2%–8.7% for measuring spiked human serum were also achieved. The results reveal that the proposed assay offers a rapid, sensitive, and specific method, which is useful for development in point‐of‐care testing for early detection and treatment of HCC.
- 4 September 2023
- Published by Wiley in Journal of Cellular Biochemistry
- Vol. 124 (10) , 1546-1556
Development of lectin‐based lateral flow assay for fucosylated alpha‐fetoprotein
Fucosylated alpha‐fetoprotein (AFP‐L3) is a more specific and sensitive biomarker for early diagnosis of hepatocellular carcinoma (HCC) than only the alpha‐fetoprotein (AFP) level. Rapid and simple detection of AFP‐L3 level greatly facilitates the early detection as well as the treatment of HCC, resulting in the reduction of mortality. Here, we developed a rapid and sensitive lateral flow assay (LFA) using lectin Lens culinaris agglutinin (LCA), which has a specific affinity to AFP‐L3 fraction of AFP, as a biorecognition element for determination of the fucosylation of AFP. The assay is based on a sandwich format performed on a lateral flow test strip. LCA was immobilized on the membrane as a test line (T). Quantitative detection of AFP‐L3 was achieved by measuring the green color intensity of captured gold nanoparticle conjugates on the T and control line (C) utilizing an in‐house test strip reader. The calculated absorbance obtained by the green color intensity signals proportionally increased with AFP concentrations. The developed lectin‐based LFA provided a detection limit of 0.8 ng/mL for AFP with a linear range between 1.5 and 160.0 ng/mL within an assay time of 10 min. Recoveries between 74.5% and 113.2% with relative standard deviations of 5.2%–8.7% for measuring spiked human serum were also achieved. The results reveal that the proposed assay offers a rapid, sensitive, and specific method, which is useful for development in point‐of‐care testing for early detection and treatment of HCC.
- 1 February 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (2) , 200-207
A Simple Colorimetric Procedure using a Smartphone Camera for Determination of Copper in Copper Supported Silica Catalysts
A simple and low cost colorimetric procedure using an Android smartphone was developed for determination of copper(II) in copper supported silica catalysts. The developed software was installed in a smartphone for measuring the intensity of the blue color produced by the reaction between copper(II) and 2-carboxy-2'-hydroxy-5'-sulfoformazyl-benzene in an acidic solution. More than one sample can be measured by taking only one photo shot. Under the selected conditions, the linear range from 0 to 5 mg/L was obtained with the detection and quantitation limits of 0.04 and 0.13 mg/L, respectively. The method provided a good precision with the percent relative standard deviation values less than 5%. The percent recoveries were in the range of 97–104%. The results corresponded well with those obtained by atomic absorption spectrophotometry. This developed method is convenient, rapid and simple with an uncomplicated device.
- 1 February 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (2) , 200-207
A Simple Colorimetric Procedure using a Smartphone Camera for Determination of Copper in Copper Supported Silica Catalysts
A simple and low cost colorimetric procedure using an Android smartphone was developed for determination of copper(II) in copper supported silica catalysts. The developed software was installed in a smartphone for measuring the intensity of the blue color produced by the reaction between copper(II) and 2-carboxy-2'-hydroxy-5'-sulfoformazyl-benzene in an acidic solution. More than one sample can be measured by taking only one photo shot. Under the selected conditions, the linear range from 0 to 5 mg/L was obtained with the detection and quantitation limits of 0.04 and 0.13 mg/L, respectively. The method provided a good precision with the percent relative standard deviation values less than 5%. The percent recoveries were in the range of 97–104%. The results corresponded well with those obtained by atomic absorption spectrophotometry. This developed method is convenient, rapid and simple with an uncomplicated device.
- 22 January 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (6) , 855-864
A compact multi-parameter detection system based on hydrodynamic sequential injection for sensitive determination of phosphate, nitrite, and nitrate in water samples
A miniaturized microfluidic hydrodynamic sequential injection system for multi-parameter analysis with a sensitive colorimetric detection was developed to improve the analytical performance for the measurement of phosphate, nitrite, and nitrate based on molybdenum blue and Griess methods. A homemade colorimetric detection with a light emitting diode as a light source and phototransistor light sensor was integrated into the microfluidic platform to achieve a low cost compact system with low reagent consumption and high sensitivity. Under the optimized working conditions, a linear calibration graph of phosphate (two working range), nitrite and nitrate (as nitrogen, N) in the range of 0.01–0.1 and 0.3–1.0 mg of PO4 3− P L−1, 0.005–0.05 mg of NO2 − N L−1 and 0.01–0.12 mg of NO3 − N L−1, respectively were achieved with a sample-throughput of 10 h−1. The limit of detections were 0.005 mg of PO4 3− P L−1, 0.0026 mg of NO2 − N L−1 and 0.005 mg of NO3 − N L−1. The percentage of recovery for phosphate, nitrite, and nitrate were 90.3–115.0, 90.0–117.0 and 91.3–117.0, respectively, with relative standard deviations in the range of 1.07–4.90%. Capabilities of the developed device for consecutive analysis of multiple analytes were demonstrated to be an excellent choice for water quality monitoring.
- 22 January 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (6) , 855-864
A compact multi-parameter detection system based on hydrodynamic sequential injection for sensitive determination of phosphate, nitrite, and nitrate in water samples
A miniaturized microfluidic hydrodynamic sequential injection system for multi-parameter analysis with a sensitive colorimetric detection was developed to improve the analytical performance for the measurement of phosphate, nitrite, and nitrate based on molybdenum blue and Griess methods. A homemade colorimetric detection with a light emitting diode as a light source and phototransistor light sensor was integrated into the microfluidic platform to achieve a low cost compact system with low reagent consumption and high sensitivity. Under the optimized working conditions, a linear calibration graph of phosphate (two working range), nitrite and nitrate (as nitrogen, N) in the range of 0.01–0.1 and 0.3–1.0 mg of PO4 3− P L−1, 0.005–0.05 mg of NO2 − N L−1 and 0.01–0.12 mg of NO3 − N L−1, respectively were achieved with a sample-throughput of 10 h−1. The limit of detections were 0.005 mg of PO4 3− P L−1, 0.0026 mg of NO2 − N L−1 and 0.005 mg of NO3 − N L−1. The percentage of recovery for phosphate, nitrite, and nitrate were 90.3–115.0, 90.0–117.0 and 91.3–117.0, respectively, with relative standard deviations in the range of 1.07–4.90%. Capabilities of the developed device for consecutive analysis of multiple analytes were demonstrated to be an excellent choice for water quality monitoring.
- 1 June 2019
- Published by Elsevier in Microchemical Journal
- Vol. 147, 403-410
A compact hydrodynamic sequential injection system for consecutive on-line determination of phosphate and ammonium
- 1 June 2019
- Published by Elsevier in Microchemical Journal
- Vol. 147, 403-410
A compact hydrodynamic sequential injection system for consecutive on-line determination of phosphate and ammonium
- 26 January 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 99 (2) , 139-156
Use of unmodified silver nanoparticles (AgNPs) as colorimetric Hg(II) sensor: A new approach to sensitive and high sample throughput determination of Hg(II) under high influence of ionic suppression
Facile unmodified silver nanoparticles (AgNPs) as colorimetric sensor for determination of Hg(II) ions in aqueous samples were developed using UV-Vis spectrophotometry. Abrupt change in absorbance of the AgNPs was observed, which progressively decreased and slightly shifted to the blue wavelength as the concentration of Hg(II) increased. It appears that the AgNPs were oxidized by Hg(II), resulting in disintegration of the AgNPs and Hg(0). Deposition of Hg(0) on the surface of AgNPs also occurred, resulting in amalgam particles of mercury (Hg-Ag). Interestingly, the developed approach showed a significant enhancement in the Hg(II) analytical sensitivity when formic acid was doped onto the AgNPs, with the linearity range of 0.01–10 mg L−1 (r2 = 0.999) providing the quantitative detection limit of 0.007 mg L−1 (3SD blank/slope of the calibration curve). Greater selectivity toward Hg(II) over other ions and colour dyes was also observed, likely a result of stabilization by polyvinylpyrrolidone (PVP), which kept the AgNPs well-stabilized and dispersed in the bulk aqueous environment making them resistant to ionic suppression. Under using a 96-well microplate and a smartphone equipped with homemade application as a colorimetric analyzer under controlled lighting, high sample throughput (128 sample h−1, n = 4) was achieved, establishing its potential for practical analysis. The percentage recoveries of spiked aqueous samples obtained from the microplate-based system were in acceptable range, in agreement with the values obtained from the UV-Vis spectrophotometry-based system. The proposed colorimetric sensor has been shown to provide a rapid, simple, sensitive and selective detection of Hg(II) ions in various aqueous samples.
- 26 January 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 99 (2) , 139-156
Use of unmodified silver nanoparticles (AgNPs) as colorimetric Hg(II) sensor: A new approach to sensitive and high sample throughput determination of Hg(II) under high influence of ionic suppression
Facile unmodified silver nanoparticles (AgNPs) as colorimetric sensor for determination of Hg(II) ions in aqueous samples were developed using UV-Vis spectrophotometry. Abrupt change in absorbance of the AgNPs was observed, which progressively decreased and slightly shifted to the blue wavelength as the concentration of Hg(II) increased. It appears that the AgNPs were oxidized by Hg(II), resulting in disintegration of the AgNPs and Hg(0). Deposition of Hg(0) on the surface of AgNPs also occurred, resulting in amalgam particles of mercury (Hg-Ag). Interestingly, the developed approach showed a significant enhancement in the Hg(II) analytical sensitivity when formic acid was doped onto the AgNPs, with the linearity range of 0.01–10 mg L−1 (r2 = 0.999) providing the quantitative detection limit of 0.007 mg L−1 (3SD blank/slope of the calibration curve). Greater selectivity toward Hg(II) over other ions and colour dyes was also observed, likely a result of stabilization by polyvinylpyrrolidone (PVP), which kept the AgNPs well-stabilized and dispersed in the bulk aqueous environment making them resistant to ionic suppression. Under using a 96-well microplate and a smartphone equipped with homemade application as a colorimetric analyzer under controlled lighting, high sample throughput (128 sample h−1, n = 4) was achieved, establishing its potential for practical analysis. The percentage recoveries of spiked aqueous samples obtained from the microplate-based system were in acceptable range, in agreement with the values obtained from the UV-Vis spectrophotometry-based system. The proposed colorimetric sensor has been shown to provide a rapid, simple, sensitive and selective detection of Hg(II) ions in various aqueous samples.
- 24 September 2018
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 15 (7) , 403-410
Mobile-phone-based colourimetric analysis for determining nitrite content in water
Environmental context: A widespread pollutant in groundwater, rivers and lakes is nitrite, which is commonly determined batchwise by using colourimetry. The batchwise method, however, requires relatively large and expensive instrumentation, and hence is unsuitable for in-field measurements. This work introduces a simple and portable colourimetric analyser based on a mobile-phone camera for monitoring nitrite concentrations in environmental water samples. A cost-effective and portable colourimetric analyser installed on a mobile phone was used to measure nitrite in water samples in Chiang Mai City, Thailand. The colourimetric detection was based on the Griess reaction, in which nitrite ion reacts with sulfanilic acid under acidic conditions to produce a diazonium salt that further reacts with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a red–violet azo dye. Under controlled conditions using a light-tight box with LED flash lights, images of the red–violet solution were captured using a built-in camera and further analysed by a program, Panalysis, on the mobile phone. The calibration graph was created by measuring the red colour intensity of a series of standard nitrite solutions from 0.09–1.8 mg N L-1. The calibration equation was then automatically stored for nitrite analysis. The results demonstrated good performance of the mobile phone analyser as an analytical instrument. The accuracy (RE <4%) and precision (RSD = 1%, intra- and inter-day) were also obtained with a detection limit of 0.03 mg N L-1 and a sample throughput of 40 samples per hour. Our results establish this simple, inexpensive and portable device as a reliable in-field monitor of nitrite in environmental waters.
- 24 September 2018
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 15 (7) , 403-410
Mobile-phone-based colourimetric analysis for determining nitrite content in water
Environmental context: A widespread pollutant in groundwater, rivers and lakes is nitrite, which is commonly determined batchwise by using colourimetry. The batchwise method, however, requires relatively large and expensive instrumentation, and hence is unsuitable for in-field measurements. This work introduces a simple and portable colourimetric analyser based on a mobile-phone camera for monitoring nitrite concentrations in environmental water samples. A cost-effective and portable colourimetric analyser installed on a mobile phone was used to measure nitrite in water samples in Chiang Mai City, Thailand. The colourimetric detection was based on the Griess reaction, in which nitrite ion reacts with sulfanilic acid under acidic conditions to produce a diazonium salt that further reacts with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a red–violet azo dye. Under controlled conditions using a light-tight box with LED flash lights, images of the red–violet solution were captured using a built-in camera and further analysed by a program, Panalysis, on the mobile phone. The calibration graph was created by measuring the red colour intensity of a series of standard nitrite solutions from 0.09–1.8 mg N L-1. The calibration equation was then automatically stored for nitrite analysis. The results demonstrated good performance of the mobile phone analyser as an analytical instrument. The accuracy (RE <4%) and precision (RSD = 1%, intra- and inter-day) were also obtained with a detection limit of 0.03 mg N L-1 and a sample throughput of 40 samples per hour. Our results establish this simple, inexpensive and portable device as a reliable in-field monitor of nitrite in environmental waters.
- Open Access
- 10 January 2018
- Published by Springer Nature in Analytical Sciences
- Vol. 34 (1) , 75-81
Use of a Smartphone as a Colorimetric Analyzer in Paper-based Devices for Sensitive and Selective Determination of Mercury in Water Samples
A smartphone application, called CAnal, was developed as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury(II) in water samples. Measurement on the double layer of a microfluidic paper-based analytical device (μPAD) fabricated by alkyl ketene dimer (AKD)-inkjet printing technique with special design doped with unmodified silver nanoparticles (AgNPs) onto the detection zones was performed by monitoring the gray intensity in the blue channel of AgNPs, which disintegrated when exposed to mercury(II) on μPAD. Under the optimized conditions, the developed approach showed high sensitivity, low limit of detection (0.003 mg L−1, 3SD blank/slope of the calibration curve), small sample volume uptake (two times of 2 μL), and short analysis time. The linearity range of this technique ranged from 0.01 to 10 mg L−1 (r2 = 0.993). Furthermore, practical analysis of various water samples was also demonstrated to have acceptable performance that was in agreement with the data from cold vapor atomic absorption spectrophotometry (CV-AAS), a conventional method. The proposed technique allows for a rapid, simple (instant report of the final mercury(II) concentration in water samples via smartphone display), sensitive, selective, and on-site analysis with high sample throughput (48 samples h−1, n = 3) of trace mercury(II) in water samples, which is suitable for end users who are unskilled in analyzing mercury(II) in water samples.
- 10 January 2018
- Published by Springer Nature in Analytical Sciences
- Vol. 34 (1) , 75-81
Open AccessUse of a Smartphone as a Colorimetric Analyzer in Paper-based Devices for Sensitive and Selective Determination of Mercury in Water Samples
A smartphone application, called CAnal, was developed as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury(II) in water samples. Measurement on the double layer of a microfluidic paper-based analytical device (μPAD) fabricated by alkyl ketene dimer (AKD)-inkjet printing technique with special design doped with unmodified silver nanoparticles (AgNPs) onto the detection zones was performed by monitoring the gray intensity in the blue channel of AgNPs, which disintegrated when exposed to mercury(II) on μPAD. Under the optimized conditions, the developed approach showed high sensitivity, low limit of detection (0.003 mg L−1, 3SD blank/slope of the calibration curve), small sample volume uptake (two times of 2 μL), and short analysis time. The linearity range of this technique ranged from 0.01 to 10 mg L−1 (r2 = 0.993). Furthermore, practical analysis of various water samples was also demonstrated to have acceptable performance that was in agreement with the data from cold vapor atomic absorption spectrophotometry (CV-AAS), a conventional method. The proposed technique allows for a rapid, simple (instant report of the final mercury(II) concentration in water samples via smartphone display), sensitive, selective, and on-site analysis with high sample throughput (48 samples h−1, n = 3) of trace mercury(II) in water samples, which is suitable for end users who are unskilled in analyzing mercury(II) in water samples.
- 22 October 2017
- Published by Society of Glass Technology in Physics and Chemistry Of Glasses-European Journal Of Glass Science and Technology Part B
- Vol. 58 (5) , 207-216
Influence of ionic radius modifying oxides on the elastic properties of glasses using ultrasonic techniques and FTIR spectroscopy
We prepared a new series of glasses by melting a mixture of recycled window glass and different metal oxides. We investigated the effects of the modifying ionic radius on elastic moduli, Poisson's ratio and fractal bond connectivity. The Debye temperature, softening temperature and latent heat of melting were measured. The bond compression model was compared with the experimental values. The structural properties were determined using FTIR spectroscopy. The results show that ionic radius has significant effects on the structural properties. The results of Poisson's ratio and fractal bond connectivity reveal that the ionic radius of modifiers could be used for the prediction of the structural properties of glass samples.
- 22 October 2017
- Published by Society of Glass Technology in Physics and Chemistry Of Glasses-European Journal Of Glass Science and Technology Part B
- Vol. 58 (5) , 207-216
Influence of ionic radius modifying oxides on the elastic properties of glasses using ultrasonic techniques and FTIR spectroscopy
We prepared a new series of glasses by melting a mixture of recycled window glass and different metal oxides. We investigated the effects of the modifying ionic radius on elastic moduli, Poisson's ratio and fractal bond connectivity. The Debye temperature, softening temperature and latent heat of melting were measured. The bond compression model was compared with the experimental values. The structural properties were determined using FTIR spectroscopy. The results show that ionic radius has significant effects on the structural properties. The results of Poisson's ratio and fractal bond connectivity reveal that the ionic radius of modifiers could be used for the prediction of the structural properties of glass samples.