ZZZhongshuai Zhang

Zhongshuai Zhang

*This is an algorithmically generated author record based on publicly available information.

Zhongshuai Zhang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Caixia Fu

    MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd, Shenzhen, China

    1 shared publication
  • Furu Wang

    Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, China

    1 shared publication
  • Hong Wang

    Department of Radiology, the Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, China

    1 shared publication
  • Hongchang Yu

    Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, China

    1 shared publication
  • Jiangtao Zhu

    Department of Radiology, The Second Affiliated Hospital of Soochow University, Suzhou, China

    1 shared publication
  • Jianming Xu

    Department of Radiology, The Affiliated Suzhou Hospital of Nanjing University Medical School, Suzhou, China

    1 shared publication

Latest Publications

  • Open Access

    Performance of TGSE BLADE DWI compared with RESOLVE DWI in the diagnosis of cholesteatoma

    by Yaru Sheng, Rujian Hong, Yan Sha, Zhongshuai Zhang, Kun Zhou, Caixia Fu

    Background: Based on its high resolution in soft tissue, MRI, especially diffusion-weighted imaging (DWI), is increasingly important in the evaluation of cholesteatoma. The purpose of this study was to evaluate the role of the 2D turbo gradient- and spin-echo (TGSE) diffusion-weighted (DW) pulse sequence with the BLADE trajectory technique in the diagnosis of cholesteatoma at 3 T and to qualitatively and quantitatively compare image quality between the TGSE BLADE and RESOLVE methods. Method: A total of 42 patients (23 males, 19 females; age range, 7–65 years; mean, 40.1 years) with surgically confirmed cholesteatoma in the middle ear were enrolled in this study. All patients underwent DWI (both a prototype TGSE BLADE DWI sequence and the RESOLVE DWI sequence) using a 3-T scanner with a 64-channel brain coil. Qualitative imaging parameters (imaging sharpness, geometric distortion, ghosting artifacts, and overall imaging quality) and quantitative imaging parameters (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR], contrast, and contrast-to-noise ratio [CNR]) were assessed for the two diffusion acquisition techniques by two independent radiologists. Result: A comparison of qualitative scores indicated that TGSE BLADE DWI produced less geometric distortion, fewer ghosting artifacts (P < 0.001) and higher image quality (P < 0.001) than were observed for RESOLVE DWI. A comparison of the evaluated quantitative image parameters between TGSE and RESOLVE showed that TGSE BLADE DWI produced a significantly lower SNR (P < 0.001) and higher parameter values (both contrast and CNR (P < 0.001)) than were found for RESOLVE DWI. The ADC (P < 0.001) was significantly lower for TGSE BLADE DWI (0.763 × 10− 3 mm2/s) than RESOLVE DWI (0.928 × 10− 3 mm2/s). Conclusion: Compared with RESOLVE DWI, TGSE BLADE DWI significantly improved the image quality of cholesteatoma by reducing magnetic sensitive artifacts, distortion, and blurring. TGSE BLADE DWI is more valuable than RESOLVE DWI for the diagnosis of small-sized (2 mm) cholesteatoma lesions. However, TGSE BLADE DWI also has some disadvantages: the whole image intensity is slightly low, so that the anatomical details of the air-bone interface are not shown well, and this shortcoming should be improved in the future.


  • Comparison between readout-segmented and single-shot echo-planar imaging in the evaluation of cervical cancer staging

    by Weiliang Qian, Qian Chen, Zhongshuai Zhang, Hong Wang, Jibin Zhang, Jianming Xu

    Objective:To compare the performance of diffusion-weighted imaging (DWI) based on readout-segmented echo-planar imaging (RESOLVE) and single-shot EPI (SS-EPI) sequence in evaluating cervical cancer...