Makoto Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Makoto Suzuki has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Hidemichi Kawata
Department of Radiology, Kurume University Hospital, Kurume, Japan
1 shared publication- Hitoshi Tadenuma
Department of Radiological Services, Tokyo Women's Medical University, Tokyo, Japan
1 shared publication - Isao Tanaka
Department of Radiological Service, Tokyo Women's Medical University Hospital , Shinjuku , Japan
1 shared publication Kazutaka Nashiki
Department of Radiology, Kurume University Hospital, Kurume, Japan
1 shared publication- Masami Yoneyama
Philips Japan, Tokyo, Japan
1 shared publication - Satoru Morita
Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University Hospital , Shinjuku , Japan
1 shared publication
Latest Publications
- 10 May 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (3) , 637-644
Influence of Gd-EOB-DTPA on proton-density fat fraction in the liver using chemical shift-encoded magnetic resonance imaging at 3-T
Non-alcoholic fatty liver disease (NAFLD) and its advanced stage, non-alcoholic steatohepatitis (NASH), have become increasingly prevalent owing to the rise in metabolic syndromes. Accurate assessment of hepatic fat deposition and inflammation is crucial for diagnosing and managing NAFLD/NASH. We investigated the influence of Gd-EOB-DTPA, (EOB) on proton-density fat fraction (PDFF) measurements using chemical shift-encoded magnetic resonance imaging (CSE-MRI) at 3-T. In total, 431 patients who underwent EOB contrast-enhanced MRI were included. PDFF measurements were obtained from pre- and post-contrast CSE-MRI. Linear regression and Bland–Altman analyses were performed to assess the correlation and agreement between pre- and post-EOB PDFF measurements. Relative enhancement (RE) of the liver was calculated as an EOB uptake index. There was a significant decrease in PDFF following EOB administration compared with the pre-contrast values (P < 0.0001), which was observed across all PDFF ranges (< 10% and ≥ 10%). Linear regression analysis revealed high correlation between pre- and post-EOB PDFF measurements. Bland–Altman analysis indicated a small bias between pre- and post-EOB PDFF values. Subgroup analysis based on RE showed a significant difference in ΔPDFF between patients with high RE (> 120%) and those with lower RE levels. EOB administration resulted in a slight decrease in PDFF measurements obtained using CSE-MRI at 3-T. We were able to generalize and clarify that the PDFF of the liver on 3D CSE-MRI at 3-T was slightly decreased after EOB administration as we used a larger group of patients compared to previous studies.
- 10 May 2024
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 17 (3) , 637-644
Influence of Gd-EOB-DTPA on proton-density fat fraction in the liver using chemical shift-encoded magnetic resonance imaging at 3-T
Non-alcoholic fatty liver disease (NAFLD) and its advanced stage, non-alcoholic steatohepatitis (NASH), have become increasingly prevalent owing to the rise in metabolic syndromes. Accurate assessment of hepatic fat deposition and inflammation is crucial for diagnosing and managing NAFLD/NASH. We investigated the influence of Gd-EOB-DTPA, (EOB) on proton-density fat fraction (PDFF) measurements using chemical shift-encoded magnetic resonance imaging (CSE-MRI) at 3-T. In total, 431 patients who underwent EOB contrast-enhanced MRI were included. PDFF measurements were obtained from pre- and post-contrast CSE-MRI. Linear regression and Bland–Altman analyses were performed to assess the correlation and agreement between pre- and post-EOB PDFF measurements. Relative enhancement (RE) of the liver was calculated as an EOB uptake index. There was a significant decrease in PDFF following EOB administration compared with the pre-contrast values (P < 0.0001), which was observed across all PDFF ranges (< 10% and ≥ 10%). Linear regression analysis revealed high correlation between pre- and post-EOB PDFF measurements. Bland–Altman analysis indicated a small bias between pre- and post-EOB PDFF values. Subgroup analysis based on RE showed a significant difference in ΔPDFF between patients with high RE (> 120%) and those with lower RE levels. EOB administration resulted in a slight decrease in PDFF measurements obtained using CSE-MRI at 3-T. We were able to generalize and clarify that the PDFF of the liver on 3D CSE-MRI at 3-T was slightly decreased after EOB administration as we used a larger group of patients compared to previous studies.
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180489
Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging
To compare single-shot turbo spin-echo (TSE) diffusion-weighted whole-body imaging with background suppression (DWIBS) and echo-planar imaging (EPI) DWIBS to determine the feasibility of direct-coronal TSE-DWIBS. All measurements were performed using a 3.0 T MRI scanner. In the phantom study, we compared the contrast ratios (CRs) of tumor-mimicking phantom (tumor) to muscle-mimicking phantom (muscle) and water to muscle and the signal-to-noise ratio (SNR) between TSE-DWIBS and EPI-DWIBS. In the volunteer study, 10 healthy volunteers were whole-body scanned with direct-coronal TSE-DWIBS, direct-coronal EPI-DWIBS (corEPI-DWIBS), and transverse EPI-DWIBS (traEPI-DWIBS). Two radiologists assessed the image distortion, uniformity of fat suppression, overall artifacts, and overall image quality in maximum intensity projection (MIP) images from each DWIBS image using a 5-point scale. In the phantom study, the CR of tumor to muscle was found to be lower for TSE-DWIBS (10.57 ± 0.45) than for EPI-DWIBS (15.38 ± 0.27), and the CR of water to muscle was higher for TSE-DWIBS (9.61 ± 0.66) than for EPI-DWIBS (2.52 ± 0.60). The volunteer study revealed good inter observer agreement between TSE-DWIBS and EPI-DWIBS with respect to image distortion, uniformity of fat suppression, overall artifacts, and overall image quality, with weighted Cohen’s κ coefficients of 0.91, 0.74, 0.87, and 0.72, respectively. Qualitative analysis scores for image distortion, uniformity of fat suppression, overall artifacts, and overall image quality were significantly higher for TSE-DWIBS than for corEPI-DWIBS or traEPI-DWIBS (p < 0.05). Direct-coronal TSE-DWIBS is robust against magnetic field inhomogeneity. High-quality images without distortion or fat suppression inhomogeneity were obtained. Many studies on DWIBS have been previously reported; however, these studies used EPI read-out. To the best of our knowledge, no studies using TSE read-out have been reported. In this study, we examined the feasibility of TSE-DWIBS with lesser artifacts than EPI-DWIBS.
- 1 February 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1094) , 20180489
Artifact-robust diffusion-weighted whole-body imaging with background suppression at 3 T using improved turbo spin-echo diffusion-weighted imaging
To compare single-shot turbo spin-echo (TSE) diffusion-weighted whole-body imaging with background suppression (DWIBS) and echo-planar imaging (EPI) DWIBS to determine the feasibility of direct-coronal TSE-DWIBS. All measurements were performed using a 3.0 T MRI scanner. In the phantom study, we compared the contrast ratios (CRs) of tumor-mimicking phantom (tumor) to muscle-mimicking phantom (muscle) and water to muscle and the signal-to-noise ratio (SNR) between TSE-DWIBS and EPI-DWIBS. In the volunteer study, 10 healthy volunteers were whole-body scanned with direct-coronal TSE-DWIBS, direct-coronal EPI-DWIBS (corEPI-DWIBS), and transverse EPI-DWIBS (traEPI-DWIBS). Two radiologists assessed the image distortion, uniformity of fat suppression, overall artifacts, and overall image quality in maximum intensity projection (MIP) images from each DWIBS image using a 5-point scale. In the phantom study, the CR of tumor to muscle was found to be lower for TSE-DWIBS (10.57 ± 0.45) than for EPI-DWIBS (15.38 ± 0.27), and the CR of water to muscle was higher for TSE-DWIBS (9.61 ± 0.66) than for EPI-DWIBS (2.52 ± 0.60). The volunteer study revealed good inter observer agreement between TSE-DWIBS and EPI-DWIBS with respect to image distortion, uniformity of fat suppression, overall artifacts, and overall image quality, with weighted Cohen’s κ coefficients of 0.91, 0.74, 0.87, and 0.72, respectively. Qualitative analysis scores for image distortion, uniformity of fat suppression, overall artifacts, and overall image quality were significantly higher for TSE-DWIBS than for corEPI-DWIBS or traEPI-DWIBS (p < 0.05). Direct-coronal TSE-DWIBS is robust against magnetic field inhomogeneity. High-quality images without distortion or fat suppression inhomogeneity were obtained. Many studies on DWIBS have been previously reported; however, these studies used EPI read-out. To the best of our knowledge, no studies using TSE read-out have been reported. In this study, we examined the feasibility of TSE-DWIBS with lesser artifacts than EPI-DWIBS.