Gabriele DaAmico
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gabriele DaAmico has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alfredo Portone
Fusion for Energy, Barcelona, Spain
3 shared publications - Alessandro Bonito-Oliva
Fusion for Energy, Barcelona, Spain
2 shared publications - Edoardo Pompa
Fusion for Energy, 229072 Barcelona, Catalunya Spain
2 shared publications - Marc Jimenez
Fusion for Energy, Barcelona, Spain
2 shared publications Alessandro Lo Bue
ITER Delivery Department at Fusion for Energy, Barcelona, Spain
1 shared publication- Alexander Vostner
ITER Organization, Saint-Paul-ls-Durance, France
1 shared publication
Latest Publications
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
TF Coil Displacement Distortion FE Analysis Simulating Non-Constant Assembly Gap Between Wedging Interfaces of TF Coils
The early plasma ramp-up on ITER will be performed under a limiter configuration. In this early plasma phase, the possible misalignments between the plasma configuration and the ITER first wall panels (FWP) in the inboard regions can lead to an increase of the power flux density acting on the FWPs. This situation is considered as a safety risk for the machine: a significant increase of the flux density may exceed the design limits of the FWPs and damage the inboard modules. Therefore, in order to avoid an excessive increase of the power flux density on the FWPs, one of the main goals of the tokamak assembly strategy is to achieve the most symmetric magnetic field structure and the best blanket alignment. The symmetric toroidal field (TF) coils structure is key for achieving the symmetric magnetic field. In the ideal case, the assembly gap dimensions in the wedging interfaces of every two adjacent TF coils are designed as an uniform value, i.e., 2 mm. However, in reality the assembly gap tolerances can be generated during the manufacturing and assembly process of the TF coils, which can lead to the asymmetric TF coils structure configuration after energization. The purpose of this paper is to investigate and discuss the consequent displacement distortions of the TF coils by simulating the non-constant assembly gap distributions in a 360° mechanical FE model of the ITER TF system.
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
TF Coil Displacement Distortion FE Analysis Simulating Non-Constant Assembly Gap Between Wedging Interfaces of TF Coils
The early plasma ramp-up on ITER will be performed under a limiter configuration. In this early plasma phase, the possible misalignments between the plasma configuration and the ITER first wall panels (FWP) in the inboard regions can lead to an increase of the power flux density acting on the FWPs. This situation is considered as a safety risk for the machine: a significant increase of the flux density may exceed the design limits of the FWPs and damage the inboard modules. Therefore, in order to avoid an excessive increase of the power flux density on the FWPs, one of the main goals of the tokamak assembly strategy is to achieve the most symmetric magnetic field structure and the best blanket alignment. The symmetric toroidal field (TF) coils structure is key for achieving the symmetric magnetic field. In the ideal case, the assembly gap dimensions in the wedging interfaces of every two adjacent TF coils are designed as an uniform value, i.e., 2 mm. However, in reality the assembly gap tolerances can be generated during the manufacturing and assembly process of the TF coils, which can lead to the asymmetric TF coils structure configuration after energization. The purpose of this paper is to investigate and discuss the consequent displacement distortions of the TF coils by simulating the non-constant assembly gap distributions in a 360° mechanical FE model of the ITER TF system.
- 4 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Metrology In-Process Control for the European Toroidal Field Coil Project
To guarantee the required performances stringent dimensional tolerances have been defined for the ITER Toroidal Field (TF) coils. The process has been divided in the following stages: reception of the parts, insertion of the Winding Pack (WP) into the Coil Cases (CC), closure welding, gap filling and final machining. At each of the production stages, metrological surveys are carried out in order to check the compliance with the defined requirements: fiducials positions, gap evaluation, virtual fit, welding distortion. In particular, one of the key elements of the magnets is the position of the Current Center Line (CCL). The CCL has to be kept under control during the production and linked to the external TF coil case interfaces. A rigid metrology process has been put in place, assuring reliable results in terms of repeatability and accuracy of the measurement. Laser tracking, sided when possible by photogrammetry technologies, have been chosen for the scope.
- 4 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Metrology In-Process Control for the European Toroidal Field Coil Project
To guarantee the required performances stringent dimensional tolerances have been defined for the ITER Toroidal Field (TF) coils. The process has been divided in the following stages: reception of the parts, insertion of the Winding Pack (WP) into the Coil Cases (CC), closure welding, gap filling and final machining. At each of the production stages, metrological surveys are carried out in order to check the compliance with the defined requirements: fiducials positions, gap evaluation, virtual fit, welding distortion. In particular, one of the key elements of the magnets is the position of the Current Center Line (CCL). The CCL has to be kept under control during the production and linked to the external TF coil case interfaces. A rigid metrology process has been put in place, assuring reliable results in terms of repeatability and accuracy of the measurement. Laser tracking, sided when possible by photogrammetry technologies, have been chosen for the scope.
- 2 February 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 166, 112282
Application of MCNP unstructured mesh in the design process of the ITER EC-UL M3 mirror
- 2 February 2021
- Published by Elsevier in Fusion Engineering and Design
- Vol. 166, 112282
Application of MCNP unstructured mesh in the design process of the ITER EC-UL M3 mirror
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Comparison of FEM Predicted and Measured Values of the ITER TF Coil Closure Welding Distortion
The ITER reactor relies in magnetic confinement of hot plasma. The main driver for the confinement is played by the Toroidal Field Coils. These magnets are composed by a Winding Pack, made of Nb3Sn superconductors, and a surrounding stainless steel structure or Coil Case which is closed by welding once the Winding Pack is inserted. The closure GTAW weld of the cases includes about 70m of weld ranging from 40 to 120mm.
- 10 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Comparison of FEM Predicted and Measured Values of the ITER TF Coil Closure Welding Distortion
The ITER reactor relies in magnetic confinement of hot plasma. The main driver for the confinement is played by the Toroidal Field Coils. These magnets are composed by a Winding Pack, made of Nb3Sn superconductors, and a surrounding stainless steel structure or Coil Case which is closed by welding once the Winding Pack is inserted. The closure GTAW weld of the cases includes about 70m of weld ranging from 40 to 120mm.
- 3 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
An Electromagnetic and Structural Finite Element Model of the ITER Toroidal Field Coils
The ITER magnet system consists of 18 toroidal field (TF) coils, a central solenoid (CS), six poloidal field (PF) coils, and a set of 18 correction coils. The TF coils provide the required toroidal magnetic field of ≈5.3 T at the plasma radius R = 6.2 m mainly needed to confine the plasma. Since the magnets are under manufacturing, nonconformity-reports (NCR) and/or deviation requests (DR) can be provided by the manufacturers. Fast checks on the impact of those design updates on the structural behavior of the system are needed before accepting their implementation. With this aim a detailed finite element model of the TF system has been developed representing two TF coils and is described in this paper. It is a three-dimensional cyclic symmetric finite element model giving a representation of the two types of coils characterizing the TF magnet: one TF coil type A (the one that supports the six PF coils) and one TF coil type B (the one that supports four out of six PF coils and the CS). The model allows computing the magnetic field during the different operating scenario of the magnet and the related Lorentz forces acting on the TF coil system. It also permits to simulate how the TF system will mechanically behave during operation. Updates of the FE mesh can be easily implemented since the model has been built in a modular way, small subcomponents of the system can be isolated and geometrically updated if needed. This is the key feature of the model, which has allowed to study in a very fast way possible NCR's and DR's produced during the manufacturing. An intensive usage of the ANSYS APDL language has been implemented in such a way that the entire analysis cascade can be executed in a completely automatic way. Due to its versatility, this tool has become the reference TF coils model in the ITER Magnet Division.
- 3 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
An Electromagnetic and Structural Finite Element Model of the ITER Toroidal Field Coils
The ITER magnet system consists of 18 toroidal field (TF) coils, a central solenoid (CS), six poloidal field (PF) coils, and a set of 18 correction coils. The TF coils provide the required toroidal magnetic field of ≈5.3 T at the plasma radius R = 6.2 m mainly needed to confine the plasma. Since the magnets are under manufacturing, nonconformity-reports (NCR) and/or deviation requests (DR) can be provided by the manufacturers. Fast checks on the impact of those design updates on the structural behavior of the system are needed before accepting their implementation. With this aim a detailed finite element model of the TF system has been developed representing two TF coils and is described in this paper. It is a three-dimensional cyclic symmetric finite element model giving a representation of the two types of coils characterizing the TF magnet: one TF coil type A (the one that supports the six PF coils) and one TF coil type B (the one that supports four out of six PF coils and the CS). The model allows computing the magnetic field during the different operating scenario of the magnet and the related Lorentz forces acting on the TF coil system. It also permits to simulate how the TF system will mechanically behave during operation. Updates of the FE mesh can be easily implemented since the model has been built in a modular way, small subcomponents of the system can be isolated and geometrically updated if needed. This is the key feature of the model, which has allowed to study in a very fast way possible NCR's and DR's produced during the manufacturing. An intensive usage of the ANSYS APDL language has been implemented in such a way that the entire analysis cascade can be executed in a completely automatic way. Due to its versatility, this tool has become the reference TF coils model in the ITER Magnet Division.
- 1 January 2002
- Published by IOS Press
- Vol. 88, 365-369
A 3-D Parametric Biomechanical Skeleton Model for Posture and Spine Shape Analysis
A project has been undertaken by our group to merge different segmental biomechanical models presented in literature into a full 3D parametric human skeleton representation, based on opto-electronic measurements. The obtained 3D skeleton model can then be fitted to each subject’s anthropometrical characteristics. The accuracy and precision of this model relies both on anatomical findings (cadaver dissections, in vivo measurements, and parametric regression equations) reported in literature and on the approach and signal processing procedures we largely described and discussed in previous papers. The aim of this work is to present and describe the above mentioned 3D parametric biomechanical skeleton model. This model and the related graphical software package have been developed as a clinical tool for diagnostic and therapeutic purposes, and they are currently used in different clinical centres.
- 1 January 2002
- Published by IOS Press
- Vol. 88, 365-369
A 3-D Parametric Biomechanical Skeleton Model for Posture and Spine Shape Analysis
A project has been undertaken by our group to merge different segmental biomechanical models presented in literature into a full 3D parametric human skeleton representation, based on opto-electronic measurements. The obtained 3D skeleton model can then be fitted to each subject’s anthropometrical characteristics. The accuracy and precision of this model relies both on anatomical findings (cadaver dissections, in vivo measurements, and parametric regression equations) reported in literature and on the approach and signal processing procedures we largely described and discussed in previous papers. The aim of this work is to present and describe the above mentioned 3D parametric biomechanical skeleton model. This model and the related graphical software package have been developed as a clinical tool for diagnostic and therapeutic purposes, and they are currently used in different clinical centres.