ISIlyas Saytashev

Ilyas Saytashev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ilyas Saytashev has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Label-free full-thickness imaging of porcine vagus nerve fascicular anatomy by polarization-sensitive optical coherence tomography

    by Yong-Chul Yoon, Ilyas Saytashev, Rex Chin-Hao Chen, Megan Settell, Fernando Guastaldi, Daniel X Hammer, Kip A Ludwig, Benjamin J Vakoc

    Objective. Improving the efficacy of vagus nerve (VN) stimulation therapy requires a detailed understanding of the anatomical and functional organization of nerve fiber bundles and their fascicles. Various ex-vivo imaging platforms have been optimized for this purpose. However, all existing tools with micrometer resolution require labeling to enhance the fascicle contrast, and this labeling is resource-intensive and time-consuming. Polarization-sensitive optical coherence tomography (PS-OCT) was previously used to perform high-speed, label-free small animal (rat) sciatic nerve imaging but has not been applied for imaging the full-thickness large animal VNs (>1 mm diameter thick) due to tissue-limited imaging depth. We developed a PS-OCT platform that circumvents this problem and demonstrate high-speed label-free imaging of full-depth, multiple centimeters-long mammalian VNs for the first time. Approach. We employed a custom-built PS-OCT system with a dual-surface scanning microscope to capture opposite sides of the sample in a single frame. A tailored post-processing algorithm maximized fascicle contrast and merged the two surfaces together. Multi-centimeter-long porcine VNs were imaged. Main Results. Our approach reconstructed fascicle information throughout the full-thickness of the VN when compressed to a 650 μm thickness. Moreover, we cross-validated PS-OCT measurements of fascicular organization and retardance to assess myelination against pair histology from the same specimens, showing Spearman’s rank correlation coefficient value of 0.69 (p-value < 0.001). Significance. We demonstrated a label-free optical imaging method for large-volume VN imaging. The time to image a 6.8 cm nerve was 680 s with 0.1 mm s−1 longitudinal sample translation speed, which is more than two orders of magnitude faster than existing modalities that require labeling. With this gain in speed and the possibility of label-free quantification of a fascicle’s myelination level, important studies on inter-sample variability in fascicle organization become feasible.


  • Open Access

    Low frequency ultrasound elicits broad cortical responses inhibited by ketamine in mice

    by Linli Shi, Christina Mastracchio, Ilyas Saytashev, Meijun Ye

    The neuromodulatory effects of >250 kHz ultrasound have been well-demonstrated, but the impact of lower-frequency ultrasound, which can transmit better through air and the skull, on the brain is unclear. This study investigates the biological impact of 40 kHz pulsed ultrasound on the brain using calcium imaging and electrophysiology in mice. Our findings reveal burst duration-dependent neural responses in somatosensory and auditory cortices, resembling responses to 12 kHz audible tone, in vivo. In vitro brain slice experiments show no neural responses to 300 kPa 40 kHz ultrasound, implying indirect network effects. Ketamine fully blocks neural responses to ultrasound in both cortices but only partially affects 12 kHz audible tone responses in the somatosensory cortex and has no impact on auditory cortex 12 kHz responses. This suggests that low-frequency ultrasound’s cortical effects rely heavily on NMDA receptors and may involve mechanisms beyond indirect auditory cortex activation. This research uncovers potential low-frequency ultrasound effects and mechanisms in the brain, offering a path for future neuromodulation.


  • Open Access

    Development of polarization-sensitive optical coherence tomography imaging platform and metrics to quantify electrostimulation-induced peripheral nerve injury in vivo in a small animal model

    by Guillermo L. Monroy, Mohsen Erfanzadeh, Michael A. Tao, Damon T. DePaoli, Ilyas Saytashev, Stephanie A. Nam, Harmain Rafi, Kasey C. Kwong, Katherine Shea, Benjamin J. Vakoc, et al.

    SignificanceNeuromodulation devices are rapidly evolving for the treatment of neurological diseases and conditions. Injury from implantation or long-term use without obvious functional losses is often only detectable through terminal histology. New technologies are needed that assess the peripheral nervous system (PNS) under normal and diseased or injured conditions.AimWe aim to demonstrate an imaging and stimulation platform that can elucidate the biological mechanisms and impacts of neurostimulation in the PNS and apply it to the sciatic nerve to extract imaging metrics indicating electrical overstimulation.ApproachA sciatic nerve injury model in a 15-rat cohort was observed using a newly developed imaging and stimulation platform that can detect electrical overstimulation effects with polarization-sensitive optical coherence tomography. The sciatic nerve was electrically stimulated using a custom-developed nerve holder with embedded electrodes for 1 h, followed by a 1-h recovery period, delivered at above-threshold Shannon model k-values in experimental groups: sham control (SC, n = 5, 0.0 mA / 0 Hz), stimulation level 1 (SL1, n = 5, 3.4 mA / 50 Hz, and k = 2.57), and stimulation level 2 (SL2, n = 5, 6.8 mA / 100 Hz, and k = 3.17).ResultsThe stimulation and imaging system successfully captured study data across the cohort. When compared to a SC after a 1-week recovery, the fascicle closest to the stimulation lead showed an average change of +4 % / − 309 % (SL1/SL2) in phase retardation and −79 % / − 148 % in optical attenuation relative to SC. Analysis of immunohistochemistry (IHC) shows a +1 % / − 36 % difference in myelin pixel counts and −13 % / + 29 % difference in axon pixel counts, and an overall increase in cell nuclei pixel count of +20 % / + 35 % . These metrics were consistent with IHC and hematoxylin/eosin tissue section analysis.ConclusionsThe poststimulation changes observed in our study are manifestations of nerve injury and repair, specifically degeneration and angiogenesis. Optical imaging metrics quantify these processes and may help evaluate the safety and efficacy of neuromodulation devices.


  • Automated peripheral nerve tissue classification based on PS-OCT derived multimodal volumes (Conference Presentation)

    by Ilyas Saytashev, Shivam Amin, Yong-Chul Yoon, Stephanie Nam, Benjamin J. Vakoc, Daniel X. Hammer

    Peripheral nerve fascicle tracing and longitudinal analysis of the damaging effects of electrical overstimulation using novel polarization sensitive optical coherence tomography (PS-OCT) based biomarkers currently require manual image segmentation to determine the boundaries of the nerve tissue within the acquired OCT volume. We developed an algorithm for automated peripheral nerve tissue classification based on image segmentation of the multimodal swept-source PS-OCT volumes. We compare the performance of density-based and neural network-based classifiers, and demonstrate results on fixed nerve tissues as well as on in vivo acquired data from a rat sciatic nerve and mini-pig vagus nerve.

  • Multi-centimeter fascicle tracing in ex-vivo porcine vagus nerve using PS-OCT (Conference Presentation)

    by Yong-Chul Yoon, Ilyas Saytashev, Rex Chin-Hao Chen, Fernando P. S. Guastaldi, Abigail L. Gregg, Kip A. Luwdig, Daniel X. Hammer, Benjamin J. Vakoc

    Vagus nerve stimulation (VNS) yields promising therapeutic benefits but is often limited by off-target effects. Imaging tools that reveal the fascicular organization within the nerve can be used to better direct stimulation energy to the intended target. Here, we demonstrate polarization-sensitive (PS)-OCT imaging of an intact 7.5 cm ex-vivo porcine vagus nerve. The limited OCT penetration depth was overcome by using a dual-scanning microscope configured to simultaneously acquire B-scans from the upper and lower segments of a nerve sample. Three-dimensional maps of the complex fascicular organization in these nerves were generated.

  • Open Access

    Improved in vivo optical coherence tomography imaging of animal peripheral nerves using a prism nerve holder

    by Ilyas Saytashev, Yong-Chul Yoon, Benjamin J. Vakoc, Srikanth Vasudevan, Daniel X. Hammer

    SignificanceModern optical volumetric imaging modalities, such as optical coherence tomography (OCT), provide enormous information about the structure, function, and physiology of living tissue. Although optical imaging achieves lateral resolution on the order of the wavelength of light used, and OCT achieves axial resolution on a similar micron scale, tissue optical properties, particularly high scattering and absorption, limit light penetration to only a few millimeters. In addition, in vivo imaging modalities are susceptible to significant motion artifacts due to cardiac and respiratory function. These effects limit access to artifact-free optical measurements during peripheral neurosurgery to only a portion of the exposed nerve without further modification to the procedure.AimWe aim to improve in vivo OCT imaging during peripheral neurosurgery in small and large animals by increasing the amount of visualized nerve volume as well as suppressing motion of the imaged area.ApproachWe designed a nerve holder with embedded mirror prisms for peripheral nerve volumetric imaging as well as a specific beam steering strategy to acquire prism and direct view volumes in one session with minimal motion artifacts.ResultsThe axially imaged volumes from mirror prisms increased the OCT signal intensity by >22 dB over a 1.25-mm imaging depth in tissue-mimicking phantoms. We then demonstrated the new imaging capabilities in visualizing peripheral nerves from direct and side views in living rats and minipigs using a polarization-sensitive OCT system. Prism views have shown nerve fascicles and vasculature from the bottom half of the imaged nerve which was not visible in direct view.ConclusionsWe demonstrated improved OCT imaging during neurosurgery in small and large animals by combining the use of a prism nerve holder with a specifically designed beam scanning protocol. Our strategy can be applied to existing OCT imaging systems with minimal hardware modification, increasing the nerve tissue volume visualized. Enhanced imaging depth techniques may lead to a greater adoption of structural and functional optical biomarkers in preclinical and clinical medicine.


  • Prism nerve holder for enhanced OCT volumetric imaging of peripheral nerves

    by Ilyas Saytashev, Anthony Parra, Yong-Chul Yoon, Benjamin J. Vakoc, Srikanth Vasudevan, Daniel X. Hammer

    We have developed a novel nerve holder, imaging protocol and post-processing routine which enhance OCT imaging by accessing peripheral nerve from 3 sides. Two mirror prisms provide imaging access from sides of a peripheral nerve in addition to conventional volume acquisition from the top. Prism glass compensates for changed focusing and optical pathlength during nerve imaging from its sides Acquired prism sub-volumes and top-bottom imaged nerve sub-volume are merged in two-stage semi-automated postprocessing routine. We demonstrate successful application of this approach on tissue-mimicking phantoms, as well as in vivo rat sciatic nerve imaging.

  • Open Access

    Auto-detection of cervical collagen and elastin in Mueller matrix polarimetry microscopic images using K-NN and semantic segmentation classification

    by Camilo Roa, V. N. Du Le, Mala Mahendroo, Ilyas Saytashev, Jessica C. Ramella-Roman

    We propose an approach for discriminating fibrillar collagen fibers from elastic fibers in the mouse cervix in Mueller matrix microscopy using convolutional neural networks (CNN) and K-nearest neighbor (K-NN) for classification. Second harmonic generation (SHG), two-photon excitation fluorescence (TPEF), and Mueller matrix polarimetry images of the mice cervix were collected with a self-validating Mueller matrix micro-mesoscope (SAMMM) system. The components and decompositions of each Mueller matrix were arranged as individual channels of information, forming one 3-D voxel per cervical slice. The classification algorithms analyzed each voxel and determined the amount of collagen and elastin, pixel by pixel, on each slice. SHG and TPEF were used as ground truths. To assess the accuracy of the results, mean-square error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) were used. Although the training and testing is limited to 11 and 5 cervical slices, respectively, MSE accuracy was above 85%, SNR was greater than 40 dB, and SSIM was larger than 90%.


  • Depth-resolved Mueller matrix polarimetry microscopy of the rat cornea

    by V. N. Du Le, Ilyas Saytashev, Sudipta Saha, Pedro F. Lopez, Megan Laughrey, Jessica C. Ramella-Roman

    Mueller matrix polarimetry (MMP) is a promising linear imaging modality that can enable visualization and measurement of the polarization properties of the cornea. Although the distribution of corneal birefringence has been reported, depth resolved MMP imaging of the cornea has not been archived and remains challenging. In this work, we perform depth-resolved imaging of the cornea using an improved system that combines Mueller matrix reflectance and transmission microscopy together with nonlinear microscopy utilizing second harmonic generation (SHG) and two photon excitation fluorescence (TPEF). We show that TPEF can reveal corneal epithelial cellular network while SHG can highlight the presence of corneal stromal lamellae. We then demonstrate that, in confocal reflectance measurement, as depth increases from 0 to 80 μm both corneal depolarization and retardation increase. Furthermore, it is shown that the spatial distribution of corneal depolarization and retardation displays similar complexity in both reflectance (confocal and non-confocal) and transmission measurement, likely due to the strong degree of heterogeneity in the stromal lamellae.


  • Self validating Mueller matrix Micro–Mesoscope (SAMMM) for the characterization of biological media

    by Ilyas Saytashev, Sudipta Saha, Joseph Chue-Sang, Pedro Lopez, Megan Laughrey, Jessica C. Ramella-Roman

    Reflectance Mueller matrix (MM) polarimetry is being used to characterize biological media in multiple clinical applications. The origin of the reflectance polarimetric data is often unclear due to the impact of multiple scattering and tissue heterogeneity. We have developed a new, to the best of our knowledge, multimodal imaging technique combining MM reflectance, MM digital confocal imaging, and co-registered nonlinear microscopy techniques. The instrument unveils the origin of reflectance polarimetric signature in terms of confocal reflectance data. The reconstructed reflected MM demonstrates the capability of our method to provide depth-resolved 3D polarization response from complex biological media in terms of depolarization, retardance, and orientation parameters.